Chlorhexidine plus alcohol versus povidone iodine plus alcohol, combined or not with innovative devices, for prevention of short-term peripheral venous catheter infection and failure (CLEAN 3 study): an investigator-initiated, open-label, single centre, randomised-controlled, two-by-two factorial trial
2021
Two billion peripheral venous catheters are sold globally each year, but the optimal skin disinfection and types of devices are not well established. We aimed to show the superiority of disinfection with 2% chlorhexidine plus alcohol over 5% povidone iodine plus alcohol in preventing infectious complications, and of closed integrated catheters, positive displacement needleless-connectors, disinfecting caps, and single-use prefilled flush syringes used in combination (innovation group) over open catheters and three-way stopcocks for treatment administration (standard group) in preventing catheter failure.
We did an open-label, randomised-controlled trial with a two-by-two factorial design, for which we enrolled adults (age ≥18 years) visiting the emergency department at the Poitiers University Hospital, France, and requiring one peripheral venous catheter before admission to the medical wards. Before catheter insertion, patients were randomly assigned (1:1:1:1) using a secure web-based random-number generator to one of four treatment groups based on skin preparation and type of devices (innovative devices or standard devices; 2% chlorhexidine plus alcohol or 5% povidone iodine plus alcohol). Primary outcomes were the incidence of infectious complications (local infection, catheter colonisation, or bloodstream infections) and time between catheter insertion and catheter failure (occlusion, dislodgment, infiltration, phlebitis, or infection). This study is registered with ClinicalTrials.gov, NCT03757143.
1000 patients were recruited between Jan 7, and Sept 6, 2019, of whom 500 were assigned to the chlorhexidine plus alcohol group and 500 to the povidone iodine plus alcohol group (250 with innovative solutions and 250 with standard devices in each antiseptic group). No significant interaction was found between the two study interventions. Local infections occurred less frequently with chlorhexidine plus alcohol than with povidone iodine plus alcohol (0 [0%] of 496 patients vs six [1%] of 493 patients) and the same was observed for catheter colonisation (4/431 [1%] vs 70/415 [17%] catheters among the catheters cultured; adjusted subdistribution hazard ratio 0·08 [95% CI 0·02–0·18]). Median time between catheter insertion and catheter failure was longer in the innovation group compared with the standard group (50·4 [IQR 29·6–69·4] h vs 30·0 [16·6–52·6] h; p=0·0017). Minor skin reactions occurred in nine (2%) patients in the chlorhexidine plus alcohol group and seven (1%) patients in the povidone iodine plus alcohol group.
For skin antisepsis, chlorhexidine plus alcohol provides greater protection of peripheral venous catheter-related infectious complications than does povidone iodine plus alcohol. Use of innovative devices extends the catheter complication-free dwell time.
Becton Dickinson.
Journal Article
Equivalent performance of single-use and reusable duodenoscopes in a randomised trial
2021
ObjectiveSingle-use duodenoscopes have been recently developed to eliminate risk of infection transmission from contaminated reusable duodenoscopes. We compared performances of single-use and reusable duodenoscopes in patients undergoing endoscopic retrograde cholangiopancreatography (ERCP).DesignPatients with native papilla requiring ERCP were randomised to single-use or reusable duodenoscope. Primary outcome was comparing number of attempts to achieve successful cannulation of desired duct. Secondary outcomes were technical performance that measured duodenoscope manoeuvrability, mechanical-imaging characteristics and ability to perform therapeutic interventions, need for advanced cannulation techniques or cross-over to alternate duodenoscope group to achieve ductal access and adverse events.Results98 patients were treated using single-use (n=48) or reusable (n=50) duodenoscopes with >80% graded as low-complexity procedures. While median number of attempts to achieve successful cannulation was significantly lower for single-use cohort (2 vs 5, p=0.013), ease of passage into stomach (p=0.047), image quality (p<0.001), image stability (p<0.001) and air–water button functionality (p<0.001) were significantly worse. There was no significant difference in rate of cannulation, adverse events including mortality (one patient in each group), need to cross-over or need for advanced cannulation techniques to achieve ductal access, between cohorts. On multivariate logistic regression analysis, only duodenoscope type (single-use) was associated with less than six attempts to achieve selective cannulation (p=0.012), when adjusted for patient demographics, procedural complexity and type of intervention.ConclusionGiven the overall safety profile and similar technical performance, single-use duodenoscopes represent an alternative to reusable duodenoscopes for performing low-complexity ERCP procedures in experienced hands.Trial registration numberClinicaltrials.gov number: NCT04143698
Journal Article
Listeria monocytogenes Persistence in Food-Associated Environments: Epidemiology, Strain Characteristics, and Implications for Public Health
2014
Over the last 10 to 15 years, increasing evidence suggests that persistence of Listeria monocytogenes in food processing plants for years or even decades is an important factor in the transmission of this foodborne pathogen and the root cause of a number of human listeriosis outbreaks. L. monocytogenes persistence in other food-associated environments (e.g., farms and retail establishments) may also contribute to food contamination and transmission of the pathogen to humans. Although L. monocytogenes persistence is typically identified through isolation of a specific molecular subtype from samples collected in a given environment over time, formal (statistical) criteria for identification of persistence are undefined. Environmental factors (e.g., facilities and equipment that are difficult to clean) have been identified as key contributors to persistence; however, the mechanisms are less well understood. Although some researchers have reported that persistent strains possess specific characteristics that may facilitate persistence (e.g., biofilm formation and better adaptation to stress conditions), other researchers have not found significant differences between persistent and nonpersistent strains in the phenotypic characteristics that might facilitate persistence. This review includes a discussion of our current knowledge concerning some key issues associated with the persistence of L. monocytogenes, with special focus on (i) persistence in food processing plants and other food-associated environments, (ii) persistence in the general environment, (iii) phenotypic and genetic characteristics of persistent strains, (iv) niches, and (v) public health and economic implications of persistence. Although the available data clearly indicate that L. monocytogenes persistence at various stages of the food chain contributes to contamination of finished products, continued efforts to quantitatively integrate data on L. monocytogenes persistence (e.g., meta-analysis or quantitative microbial risk assessment) will be needed to advance our understanding of persistence of this pathogen and its economic and public health impacts.
Journal Article
Effect of infusion set replacement intervals on catheter-related bloodstream infections (RSVP): a randomised, controlled, equivalence (central venous access device)–non-inferiority (peripheral arterial catheter) trial
by
Gill, Fenella J
,
Murgo, Marghie
,
Playford, E Geoffrey
in
Access control
,
Adults
,
Adverse events
2021
The optimal duration of infusion set use to prevent life-threatening catheter-related bloodstream infection (CRBSI) is unclear. We aimed to compare the effectiveness and costs of 7-day (intervention) versus 4-day (control) infusion set replacement to prevent CRBSI in patients with central venous access devices (tunnelled cuffed, non-tunnelled, peripherally inserted, and totally implanted) and peripheral arterial catheters.
We did a randomised, controlled, assessor-masked trial at ten Australian hospitals. Our hypothesis was CRBSI equivalence for central venous access devices and non-inferiority for peripheral arterial catheters (both 2% margin). Adults and children with expected greater than 24 h central venous access device–peripheral arterial catheter use were randomly assigned (1:1; stratified by hospital, catheter type, and intensive care unit or ward) by a centralised, web-based service (concealed before allocation) to infusion set replacement every 7 days, or 4 days. This included crystalloids, non-lipid parenteral nutrition, and medication infusions. Patients and clinicians were not masked, but the primary outcome (CRBSI) was adjudicated by masked infectious diseases physicians. The analysis was modified intention to treat (mITT). This study is registered with the Australian New Zealand Clinical Trials Registry ACTRN12610000505000 and is complete.
Between May 30, 2011, and Dec, 9, 2016, from 6007 patients assessed, we assigned 2944 patients to 7-day (n=1463) or 4-day (n=1481) infusion set replacement, with 2941 in the mITT analysis. For central venous access devices, 20 (1·78%) of 1124 patients (7-day group) and 16 (1·46%) of 1097 patients (4-day group) had CRBSI (absolute risk difference [ARD] 0·32%, 95% CI −0·73 to 1·37). For peripheral arterial catheters, one (0·28%) of 357 patients in the 7-day group and none of 363 patients in the 4-day group had CRBSI (ARD 0·28%, −0·27% to 0·83%). There were no treatment-related adverse events.
Infusion set use can be safely extended to 7 days with resultant cost and workload reductions.
Australian National Health and Medical Research Council.
Journal Article
Contamination and washing of cloth masks and risk of infection among hospital health workers in Vietnam: a post hoc analysis of a randomised controlled trial
by
Dung, Tham Chi
,
Seale, Holly
,
Rahman, Bayzidur
in
Adult
,
Betacoronavirus
,
Coronavirus Infections - epidemiology
2020
BackgroundIn a previous randomised controlled trial (RCT) in hospital healthcare workers (HCWs), cloth masks resulted in a higher risk of respiratory infections compared with medical masks. This was the only published RCT of cloth masks at the time of the COVID-19 pandemic.ObjectiveTo do a post hoc analysis of unpublished data on mask washing and mask contamination from the original RCT to further understand poor performance of the two-layered cotton cloth mask used by HCWs in that RCT.Setting14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam.ParticipantsA subgroup of 607 HCWs aged ≥18 years working full time in selected high-risk wards, who used a two-layered cloth mask and were part of a randomised controlled clinical trial comparing medical masks and cloth masks.InterventionWashing method for cloth masks (self-washing or hospital laundry). A substudy of contamination of a sample of 15 cloth and medical masks was also conducted.Outcome measureInfection rate over 4 weeks of follow up and viral contamination of masks tested by multiplex PCR.ResultsViral contamination with rhinovirus was identified on both used medical and cloth masks. Most HCW (77% of daily washing) self-washed their masks by hand. The risk of infection was more than double among HCW self-washing their masks compared with the hospital laundry (HR 2.04 (95% CI 1.03 to 4.00); p=0.04). There was no significant difference in infection between HCW who wore cloth masks washed in the hospital laundry compared with medical masks (p=0.5).ConclusionsUsing self-reported method of washing, we showed double the risk of infection with seasonal respiratory viruses if masks were self-washed by hand by HCWs. The majority of HCWs in the study reported hand-washing their mask themselves. This could explain the poor performance of two layered cloth masks, if the self-washing was inadequate. Cloth masks washed in the hospital laundry were as protective as medical masks. Both cloth and medical masks were contaminated, but only cloth masks were reused in the study, reiterating the importance of daily washing of reusable cloth masks using proper method. A well-washed cloth mask can be as protective as a medical mask.Trial resgistration numberACTRN12610000887077.
Journal Article
A New Drying Method of Thermolabile Flexible Endoscope Channels by Laminar and Turbulent Airflow: A Prospective, Randomized-Controlled, Single-Center, Proof-of-Concept Trial
by
Friedrich-Rust, Mireen
,
Walter, Dirk
,
Puhlmann, Danuta
in
Air flow
,
Bacteria
,
Clinical outcomes
2025
INTRODUCTION:International guidelines suggest different possibilities for drying of endoscopes during reprocessing. Clinical results of these available drying methods are not satisfactory. The aim of this study was to compare the drying cycle of a standard endoscope washer-disinfector (EWD) (standard drying method [SD]) with a shortened mandatory drying by the EWD followed by a special drying device using laminar and turbulent air flow (novel drying method [ND]).METHODS:Sixty endoscopes (duodenoscopes, colonoscocopes, and gastroscopes) from 3 different manufacturers underwent high-level disinfection and drying depending on the randomization group. Operational time of drying was measured for both groups. Residual fluid in the channels was measured using a laboratory scale. After a 14-day storage period, a sample of the endoscope channels was obtained to determine bacterial contamination.RESULTS:ND had significantly fewer residual water in endoscope channels (SD: 90% vs ND: 0%; P < 0.001) after high-level disinfection and drying and less bacterial contamination after storage for 14 days (SD: 47% vs ND: 20%; P = 0.028). Time consumed for drying in ND was also significantly shorter (SD: 16 minutes 4 seconds vs ND: 5 minutes 59 seconds; P < 0.001).DISCUSSION:Drying with a special automatic drying device was superior compared with an EWD's drying program as evidenced by no measurable residual water, reduced microbiological contamination, and a more than 2-fold decrease in operational time. Thus, drying by laminar and turbulent airflow may represent an attractive alternative to the currently used standard approach in the reprocessing process of flexible endoscopes.
Journal Article
Routine versus clinically indicated replacement of peripheral intravenous catheters: a randomised controlled equivalence trial
2012
Summary Background The millions of peripheral intravenous catheters used each year are recommended for 72–96 h replacement in adults. This routine replacement increases health-care costs and staff workload and requires patients to undergo repeated invasive procedures. The effectiveness of the practice is not well established. Our hypothesis was that clinically indicated catheter replacement is of equal benefit to routine replacement. Methods This multicentre, randomised, non-blinded equivalence trial recruited adults (≥18 years) with an intravenous catheter of expected use longer than 4 days from three hospitals in Queensland, Australia, between May 20, 2008, and Sept 9, 2009. Computer-generated random assignment (1:1 ratio, no blocking, stratified by hospital, concealed before allocation) was to clinically indicated replacement, or third daily routine replacement. Patients, clinical staff, and research nurses could not be masked after treatment allocation because of the nature of the intervention. The primary outcome was phlebitis during catheterisation or within 48 h after removal. The equivalence margin was set at 3%. Primary analysis was by intention to treat. Secondary endpoints were catheter-related bloodstream and local infections, all bloodstream infections, catheter tip colonisation, infusion failure, catheter numbers used, therapy duration, mortality, and costs. This trial is registered with the Australian New Zealand Clinical Trials Registry, number ACTRN12608000445370. Findings All 3283 patients randomised (5907 catheters) were included in our analysis (1593 clinically indicated; 1690 routine replacement). Mean dwell time for catheters in situ on day 3 was 99 h (SD 54) when replaced as clinically indicated and 70 h (13) when routinely replaced. Phlebitis occurred in 114 of 1593 (7%) patients in the clinically indicated group and in 114 of 1690 (7%) patients in the routine replacement group, an absolute risk difference of 0·41% (95% CI −1·33 to 2·15%), which was within the prespecified 3% equivalence margin. No serious adverse events related to study interventions occurred. Interpretation Peripheral intravenous catheters can be removed as clinically indicated; this policy will avoid millions of catheter insertions, associated discomfort, and substantial costs in both equipment and staff workload. Ongoing close monitoring should continue with timely treatment cessation and prompt removal for complications. Funding Australian National Health and Medical Research Council.
Journal Article
Impact of doffing errors on healthcare worker self-contamination when caring for patients on contact precautions
2019
We assessed the impact of personal protective equipment (PPE) doffing errors on healthcare worker (HCW) contamination with multidrug-resistant organisms (MDROs).
Prospective, observational study.
The study was conducted at 4 adult ICUs at 1 tertiary-care teaching hospital.
HCWs who cared for patients on contact precautions for methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococci, or multidrug-resistant gram-negative bacilli were enrolled. Samples were collected from standardized areas of patient body, garb sites, and high-touch environmental surfaces in patient rooms. HCW hands, gloves, PPE, and equipment were sampled before and after patient interaction. Research personnel observed PPE doffing and coded errors based on CDC guidelines.
We enrolled 125 HCWs; most were nurses (66.4%) or physicians (19.2%). During the study, 95 patients were on contact precautions for MRSA. Among 5,093 cultured sites (HCW, patient, environment), 652 (14.7%) yielded the target MDRO. Moreover, 45 HCWs (36%) were contaminated with the target MDRO after patient interactions, including 4 (3.2%) on hands and 38 (30.4%) on PPE. Overall, 49 HCWs (39.2%) made multiple doffing errors and were more likely to have contaminated clothes following a patient interaction (risk ratio [RR], 4.69; P = .04). All 4 HCWs with hand contamination made doffing errors. The risk of hand contamination was higher when gloves were removed before gowns during PPE doffing (RR, 11.76; P = .025).
When caring for patients on CP for MDROs, HCWs appear to have differential risk for hand contamination based on their method of doffing PPE. An intervention as simple as reinforcing the preferred order of doffing may reduce HCW contamination with MDROs.
Journal Article
Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device
by
Lyden, Elizabeth
,
Rupp, Mark E.
,
Marolf, Cole
in
ARTICLES AND COMMENTARIES
,
Bacteremia
,
Bacteremia - microbiology
2017
Background. Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. Methods. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5–2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. Results. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Conclusions. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. Clinical Trials Registration. NCT02102087.
Journal Article