Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
180
result(s) for
"Extraction, Obstetrical - adverse effects"
Sort by:
Lateral episiotomy or no episiotomy in vacuum assisted delivery in nulliparous women (EVA): multicentre, open label, randomised controlled trial
by
Hesselman, Susanne
,
Kopp Kallner, Helena
,
Wallström, Tove
in
Adult
,
Anal Canal - injuries
,
Births
2024
AbstractObjectiveTo assess the effect of lateral episiotomy, compared with no episiotomy, on obstetric anal sphincter injury in nulliparous women requiring vacuum extraction.DesignA multicentre, open label, randomised controlled trial.SettingEight hospitals in Sweden, 2017-23.Participants717 nulliparous women with a single live fetus of 34 gestational weeks or more, requiring vacuum extraction were randomly assigned (1:1) to lateral episiotomy or no episiotomy using sealed opaque envelopes. Randomisation was stratified by study site.InterventionA standardised lateral episiotomy was performed during the vacuum extraction, at crowning of the fetal head, starting 1-3 cm from the posterior fourchette, at a 60° (45-80°) angle from the midline, and 4 cm (3-5 cm) long. The comparison was no episiotomy unless considered indispensable.Main outcome measuresThe primary outcome of the episiotomy in vacuum assisted delivery (EVA) trial was obstetric anal sphincter injury, clinically diagnosed by combined visual inspection and digital rectal and vaginal examination. The primary analysis used a modified intention-to-treat population that included all consenting women with attempted or successful vacuum extraction. As a result of an interim analysis at significance level P<0.01, the primary endpoint was tested at 4% significance level with accompanying 96% confidence interval (CI).ResultsFrom 1 July 2017 to 15 February 2023, 717 women were randomly assigned: 354 (49%) to lateral episiotomy and 363 (51%) to no episiotomy. Before vacuum extraction attempt, one woman withdrew consent and 14 had a spontaneous birth, leaving 702 for the primary analysis. In the intervention group, 21 (6%) of 344 women sustained obstetric anal sphincter injury, compared with 47 (13%) of 358 women in the comparison group (P=0.002). The risk difference was −7.0% (96% CI −11.7% to −2.5%). The risk ratio adjusted for site was 0.47 (96% CI 0.23 to 0.97) and unadjusted risk ratio was 0.46 (0.28 to 0.78). No significant differences were noted between groups in postpartum pain, blood loss, neonatal outcomes, or total adverse events, but the intervention group had more wound infections and dehiscence.ConclusionsLateral episiotomy can be recommended for nulliparous women requiring vacuum extraction to significantly reduce the risk of obstetric anal sphincter injury.Trial registrationClinicalTrials.gov NCT02643108.
Journal Article
Episiotomy in vacuum extraction, do we cut the levator ani muscle? A prospective cohort study
2022
Introduction and hypothesisVaginal delivery may lead to levator ani muscle (LAM) injury or avulsion. Episiotomy may reduce obstetric anal sphincter injury in operative vaginal delivery, but may increase the risk of LAM injury. Our aim was to assess whether lateral episiotomy in vacuum extraction (VE) in primiparous women causes LAM injury.MethodsA prospective cohort study of 58 primiparous women with episiotomy nested within an ongoing multicenter randomized controlled trial of lateral episiotomy versus no episiotomy in VE (EVA trial) was carried out in Sweden. LAM injury was evaluated using 3D endovaginal ultrasound 6–12 months after delivery and Levator Ani Deficiency (LAD) score. Episiotomy scar properties were measured. Characteristics were described and compared using Chi-squared tests. We stipulated that if a lateral episiotomy cuts the LAM, ≥50% would have a LAM injury. Among those, ≥50% would be side specific. We compared the observed prevalence with a test of one proportion.ResultsTwelve (20.7%, 95% CI 10.9–32.9) of 58 women had a LAD (p < 0.001, compared with the stipulated 50%). Six (50.0%, 95% CI 21.1% to 78.9%) of 12 women had a LAD on the episiotomy side, including those with bilateral LAD (p = 1.00). Two (16.7%, 95% CI 2.1% to 48.4%) of 12 women had a LAD exclusively on the episiotomy side (p = 0.02).ConclusionsThere was no excessive risk of cutting the LAM while performing a lateral episiotomy. LAD was not seen in women with episiotomies shorter than 18 mm.
Journal Article
Safety and efficacy of manual vacuum suction compared with conventional dilatation and sharp curettage and electric vacuum aspiration in surgical treatment of miscarriage: a randomized controlled trial
by
Kakinuma, Kaoru
,
Matsuda, Yoshio
,
Ihara, Motomasa
in
Abortion, Spontaneous - surgery
,
Adult
,
Asherman’s syndrome
2020
Background
The World Health Organization does not recommend dilatation and sharp curettage (D&C) for the surgical treatment of miscarriage during the first trimester because this may cause Asherman’s syndrome due to endometrial damage; therefore, suction remains the primary treatment option. While manual vacuum aspiration (MVA) has been widely used since the 1990s outside Japan, the use of an MVA device (Women’s MVA system) was approved in Japan in October 2015. Here, we examined the efficacy of the MVA kit in women surgically treated for miscarriage.
Methods
This retrospective cohort study was conducted between 2014 and 2018 at the International University of Health and Welfare Hospital in Japan. Women who underwent surgical treatment for miscarriage within 12 weeks of pregnancy were identified and enrolled in the study. A total of 404 women were included who underwent the following procedures: 121 D&C, 123 electric vacuum aspiration (EVA), and 160 MVA. For each participant, the duration of surgery, amount of bleeding, amount of anesthetic used, incomplete abortion requiring repeat procedures, and intraoperative/postoperative complications were evaluated.
Results
The duration of surgery was 13.7 ± 7.2, 11.2 ± 4.2, and 6.9 ± 4.3 min in the D&C, EVA, and MVA groups, respectively (
p
= 1.00). The amount of anesthetic used was not significantly different among all groups. Bleeding of ≥ 100 mL was confirmed in three (2.4%), one (0.8%), and one (0.6%) patient(s) in the D&C, EVA, and MVA groups, respectively (
p
= 0.50). Incomplete abortion was identified in three (2.4%), two (1.6%), and one (0.6%) patient(s) in the D&C, EVA, and MVA groups, respectively (
p
= 0.61). However, severe intraoperative/postoperative complications were not observed in any group.
Conclusions
Surgical treatment for miscarriage performed using the MVA kit has safety and efficacy similar to those of conventional methods, such as D&C and EVA.
Journal Article
Perinatal outcome after vacuum assisted delivery with digital feedback on traction force; a randomised controlled study
by
Yousaf, Khurram
,
Pettersson, Kristina
,
Romero, Stefhanie
in
Adult
,
Algorithms
,
Birth Injuries - epidemiology
2021
Background
Low and mid station vacuum assisted deliveries (VAD) are delicate manual procedures that entail a high degree of subjectivity from the operator and are associated with adverse neonatal outcome. Little has been done to improve the procedure, including the technical development, traction force and the possibility of objective documentation. We aimed to explore if a digital handle with instant haptic feedback on traction force would reduce the neonatal risk during low or mid station VAD.
Methods
A two centre, randomised superiority trial at Karolinska University Hospital, Sweden, 2016–2018. Cases were randomised bedside to either a conventional or a digital handle attached to a Bird metal cup (50 mm, 80 kPa). The digital handle measured applied force including an instant notification by vibration when high levels of traction force were predicted according to a predefined algorithm. Primary outcome was a composite of hypoxic ischaemic encephalopathy, intracranial haemorrhage, seizures, death and/or subgaleal hematoma. Three hundred eighty low and mid VAD in each group were estimated to decrease primary outcome from six to 2 %.
Results
After 2 years, an interim analyse was undertaken. Meeting the inclusion criteria, 567 vacuum extractions were randomized to the use of a digital handle (
n
= 296) or a conventional handle (
n
= 271). Primary outcome did not differ between the two groups: (2.7% digital handle vs 2.6% conventional handle). The incidence of primary outcome differed significantly between the two delivery wards (4% vs 0.9%,
p
< 0.05). A recalculation of power revealed that 800 cases would be needed in each group to show a decrease in primary outcome from three to 1 %. This was not feasible, and the study therefore closed.
Conclusions
The incidence of primary outcome was lower than estimated and the study was underpowered. However, the difference between the two delivery wards might reflect varying degree of experience of the technical equipment. An objective documentation of the extraction procedure is an attractive alternative in respect to safety and clinical training. To demonstrate improved safety, a multicentre study is required to reach an adequate cohort. This was beyond the scope of the study.
Trial registration
ClinicalTrials.gov
NCT03071783
, March 1, 2017, retrospectively registered.
Journal Article
Effect of Mode of Delivery in Nulliparous Women on Neonatal Intracranial Injury
by
Eby-Wilkens, Elaine
,
Towner, Dena
,
Gilbert, William M
in
Biological and medical sciences
,
Birth Injuries - epidemiology
,
Birth Injuries - etiology
1999
Five to 25 percent of nulliparous pregnant women have operative vaginal delivery.
1
Although forceps have been used in obstetrics since the early 19th century, vacuum extraction was not widely used until the 1950s. The popularity of vacuum extraction has steadily increased with the development of newer vacuum cups; from 1985 to 1992, there was a 37 percent increase in the use of vacuum extraction and a 22 percent decline in the use of forceps in the United States.
2
The risk of serious neonatal injury associated with vacuum extraction has been controversial. Multiple studies have demonstrated the safety of soft vacuum . . .
Journal Article
Severe perineal laceration during operative vaginal delivery: the impact of occiput posterior position
2014
Objective:
To identify risk factors for severe (third/fourth degree) perineal laceration with operative vaginal delivery (OVD, forceps or vacuum).
Study Design:
Case-control study comparing singleton OVDs with or without severe laceration (
n
=138).
Result:
In multivariable analyses, severe perineal laceration was associated with occiput posterior (OP) position at delivery, vaginal nulliparity, use of forceps, longer period pushing in the second stage and lower gestational age, but not birth weight, labor induction or episiotomy. Among 29 OP patients at full dilation, 9/13 (69%) attempted rotations to occiput anterior (OA) were successful, and 14/16 (88%) patients in whom rotation was not attempted remained OP at delivery. Successful rotation from OP to OA was associated with fewer severe lacerations than no attempt or unsuccessful rotation (22 vs 75%,
P
=0.01).
Conclusion:
Severe perineal laceration during OVD is associated with OP position at delivery and is reduced threefold in patients successfully rotated from OP to OA.
Journal Article
Decreased neonatal pain response after vaginal-operative delivery with Kiwi OmniCup versus metal ventouse
2017
Background
Vaginal delivery, especially operative assisted vaginal delivery, seems to be a major stressor for the neonate. The objective of this study was to evaluate the stress response after metal cup versus Kiwi Omnicup® ventouse delivery.
Methods
The study was a secondary observational analysis of data from a former prospective randomised placebo controlled multicentre study on the analgesic effect of acetaminophen in neonates after operative vaginal delivery and took place at three Swiss tertiary hospitals. Healthy pregnant women ≥35 weeks of gestation with an estimated fetal birth weight above 2000 g were recruited after admission to the labour ward. Pain reaction was analysed by pain expression score EDIN scale (Échelle Douleur Inconfort Nouveau-Né, neonatal pain and discomfort scale) directly after delivery. For measurement of the biochemical stress response, salivary cortisol as well as the Bernese Pain Scale of Newborns (BPSN) were evaluated before and after an acute pain stimulus (the standard heel prick for metabolic testing (Guthrie test)) at 48–72 h.
Results
Infants born by vaginal operative delivery displayed a lower pain response after plastic cup than metal cup ventouse delivery (
p <
0.001), but the pain response was generally lower than expected and they recovered fully within 72 h.
Conclusions
Neonatal pain response is slightly reduced after use of Kiwi OmniCup® versus metal cup ventouse.
Trial registration
Trial was registered under under
NCT00488540
on 19th June 2007.
Journal Article
Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial
by
Margier, Jennifer
,
Langer, Bruno
,
Dreyfus, Michel
in
Adult
,
Birth injuries
,
Birth Injuries - epidemiology
2015
Background
Assisted vaginal delivery by vacuum extraction is frequent. Metallic resterilizible metallic vacuum cups have been routinely used in France. In the last few years a new disposable semi-soft vacuum extraction cup, the iCup, has been introduced. Our objective was to compare maternal and new-born outcomes between this disposable cup and the commonly used Drapier-Faure metallic cup.
Methods
This was a multicenter prospective randomized controlled open clinical trial performed in the maternity units of five university hospitals and one community hospital in France from October 2009 to February 2013. We included consecutive eligible women with a singleton gestation of at least 37 weeks who required vacuum assisted delivery. Women were randomized to
v
acuum extraction using the iCup or usual Drapier-Faure metallic cup. The primary outcome was a composite criterion including both the risk of cup dysfunction and the most frequent maternal and neonatal harms: the use of other instruments after attempted vacuum extraction, caesarean section after attempted vacuum extraction, three detachments of the cup, caput succedaneum, cephalohaematoma, episiotomy and perineal tears.
Results
335 women were randomized to the disposable cup and 333 to extraction using the metallic cup. There was no significant difference between the two groups for the primary outcome. However, failed instrumental delivery was more frequent in the disposable cup group, mainly due to detachment: 35.6 % vs 7.1 %,
p <
0.0001. Conversely, perineal tears were more frequent in the metallic cup group, especially third or fourth grade perineal tears: 1.7 % versus 5.0 %,
p =
0.003. There were no significant differences between the two groups concerning post-partum haemorrhage, transfer to a neonatal intensive care unit (NICU) or serious adverse events.
Conclusions
While the disposable cup had more detachments and extraction failures than the standard metallic cup, this innovative disposable device had the advantage of fewer perineal injuries.
Trial registration
www.clinicaltrials.gov
:
NCT01058200
on Jan. 27 2010.
Journal Article
No reduction in instrumental vaginal births and no increased risk for adverse perineal outcome in nulliparous women giving birth on a birth seat: results of a Swedish randomized controlled trial
2011
Background
The WHO advises against recumbent or supine position for longer periods during labour and birth and states that caregivers should encourage and support the woman to take the position in which she feels most comfortable. It has been suggested that upright positions may improve childbirth outcomes and reduce the risk for instrumental delivery; however RCTs of interventions to encourage upright positions are scarce. The aim of this study was to test, by means of a randomized controlled trial, the hypothesis that the use of a birthing seat during the second stage of labor, for healthy nulliparous women, decreases the number of instrumentally assisted births and may thus counterbalance any increase in perineal trauma and blood loss.
Methods
A randomized controlled trial in Sweden where 1002 women were randomized to birth on a birth seat (experimental group) or birth in any other position (control group). Data were collected between November 2006 and July 2009. The primary outcome measurement was the number of instrumental deliveries. Secondary outcome measurements included perineal lacerations, perineal edema, maternal blood loss and hemoglobin. Analysis was by intention to treat.
Results
The main findings of this study were that birth on the birth seat did not reduce the number of instrumental vaginal births, there was an increase in blood loss between 500 ml and 1000 ml in women who gave birth on the seat but no increase in bleeding over 1000 ml and no increase in perineal lacerations or perineal edema.
Conclusions
The birth seat did not reduce the number of instrumental vaginal births. The study confirmed an increased blood loss 500 ml - 1000 ml but not over 1000 ml for women giving birth on the seat. Giving birth on a birth seat caused no adverse consequences for perineal outcomes and may even be protective against episiotomies.
Trial registration number
ClinicalTrials.gov.ID:
NCT01182038
Journal Article