Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
13,252 result(s) for "Fundamental Radiation Science"
Sort by:
Effect of backscatter radiation on the occupational eye-lens dose
We quantified the level of backscatter radiation generated from physicians’ heads using a phantom. We also evaluated the shielding rate of the protective eyewear and optimal placement of the eye-dedicated dosimeter (skin surface or behind the Pb-eyewear). We performed diagnostic X-rays of two head phantoms: Styrofoam (negligible backscatter radiation) and anthropomorphic (included backscatter radiation). Radiophotoluminescence glass dosimeters were used to measure the eye-lens dose, with or without 0.07-mm Pb-equivalent protective eyewear. We used tube voltages of 50, 65 and 80 kV because the scattered radiation has a lower mean energy than the primary X-ray beam. The backscatter radiation accounted for 17.3–22.3% of the eye-lens dose, with the percentage increasing with increasing tube voltage. Furthermore, the shielding rate of the protective eyewear was overestimated, and the eye-lens dose was underestimated when the eye-dedicated dosimeter was placed behind the protective eyewear. We quantified the backscatter radiation generated from physicians’ heads. To account for the effect of backscatter radiation, an anthropomorphic, rather than Styrofoam, phantom should be used. Close contact of the dosimeter with the skin surface is essential for accurate evaluation of backscatter radiation from physician’s own heads. To assess the eye-lens dose accurately, the dosimeter should be placed near the eye. If the dosimeter is placed behind the lens of the protective eyewear, we recommend using a backscatter radiation calibration factor of 1.2–1.3.
Resveratrol protects intestinal epithelial cells against radiation-induced damage by promoting autophagy and inhibiting apoptosis through SIRT1 activation
Intrinsic autophagy is important for the maintenance of intestinal homeostasis and intestinal regeneration. Ionizing radiation suppresses intrinsic autophagy and reduces damage-induced regeneration in the intestine, resulting in intestinal injury. Resveratrol, a sirtuin 1 (SIRT1) agonist, promotes autophagy and exerts radioprotective effect. In this study, the protective effect of resveratrol against radiation-induced intestinal injury and its potential mechanism were investigated. Intestinal epithelial cells (IEC-6) were exposed to 10 Gy ionizing radiation and resveratrol (0.1–40.0 μM). Cell viability was investigated using Cell Counting Kit 8 (CCK8), apoptosis was observed by Annexin V-fluorescein isothiocyanate/propidium iodide (PI) staining and flow cytometry, and the expression of apoptotic and autophagic proteins was determined by western blotting. Resveratrol exerted a high toxicity against IEC-6 cells, but at low concentrations, it inhibited ionizing radiation-induced apoptosis. Resveratrol increased SIRT1 expression after irradiation and inhibited ionizing radiation-induced p53 acetylation and pro-apoptotic protein, Bax, expression. Furthermore, resveratrol promoted autophagy via the phosphoinositide 3-kinase (PI3K)/AKT/mammalian target of rapamycin (mTOR) pathway, thereby protecting IEC-6 cells against radiation-induced damage. These results suggest that resveratrol reduces radiation-induced IEC-6 cell damage by inhibiting apoptosis and promoting autophagy via the activation of SIRT1, and that the PI3K/AKT/mTOR signaling pathway is involved in the induction of autophagy.
DNA strand break induction of aqueous plasmid DNA exposed to 30 MeV protons at ultra-high dose rate
Abstract Radiation cancer therapy with ultra-high dose rate exposure, so called FLASH radiotherapy, appears to reduce normal tissue damage without compromising tumor response. The aim of this study was to clarify whether FLASH exposure of proton beam would be effective in reducing the DNA strand break induction. We applied a simple model system, pBR322 plasmid DNA in aqueous 1 × TE solution, where DNA single strand breaks (SSBs) and double strand breaks (DSBs) can be precisely quantified by gel electrophoresis. Plasmid DNA were exposed to 27.5 MeV protons in the conventional dose rate of 0.05 Gy/s (CONV) and ultra-high dose rate of 40 Gy/s (FLASH). With both dose rate, the kinetics of the SSB and DSB induction were proportional to absorbed dose. The SSB induction of FLASH was significantly less than CONV, which were 8.79 ± 0.14 (10−3 SSB per Gy per molecule) and 10.8 ± 0.68 (10−3 SSB per Gy per molecule), respectively. The DSB induction of FLASH was also slightly less than CONV, but difference was not significant. Altogether, 27.5 MeV proton beam at 40 Gy/s reduced SSB and not DSB, thus its effect may not be significant in reducing lethal DNA damage that become apparent in acute radiation effect.
Update of the particle irradiation data ensemble (PIDE) for cell survival
The particle irradiation data ensemble (PIDE) is the largest database of cell survival data measured after exposure to ion beams and photon reference radiation. We report here on the updated version of the PIDE database and demonstrate how to investigate generic properties of radiation dose response using these sets of raw data. The database now contains information of over 1100 pairs of photon and ion dose response curves. It provides the originally published raw data of cell survival in addition to given linear quadratic (LQ) model parameters. If available, the raw data were used to derive LQ model parameters in the same way for all experiments. To demonstrate the extent of the database and the variability among experiments we focus on the dose response curves after ion and photon radiation separately in a first step. Furthermore, we discuss the capability and the limitations of the database for analyzing properties of low and high linear energy transfer (LET) radiation response based on multiple experiments. PIDE is freely available to the research community under www.gsi.de/bio-pide.
DNA damage response in vascular endothelial senescence: Implication for radiation-induced cardiovascular diseases
A post-exposure cohort study in Hiroshima and Nagasaki reported that low-dose exposure to radiation heightened the risk of cardiovascular diseases (CVD), such as stroke and myocardial infarction, by 14–18% per Gy. Moreover, the risk of atherosclerosis in the coronary arteries reportedly increases with radiation therapy of the chest, including breast and lung cancer treatment. Cellular senescence of vascular endothelial cells (ECs) is believed to play an important role in radiation-induced CVDs. The molecular mechanism of age-related cellular senescence is believed to involve genomic instability and DNA damage response (DDR); the chronic inflammation associated with senescence causes cardiovascular damage. Therefore, vascular endothelial cell senescence is believed to induce the pathogenesis of CVDs after radiation exposure. The findings of several prior studies have revealed that ionizing radiation (IR) induces cellular senescence as well as cell death in ECs. We have previously reported that DDR activates endothelial nitric oxide (NO) synthase, and NO production promotes endothelial senescence. Endothelial NO synthase (eNOS) is a major isoform expressed in ECs that maintains cardiovascular homeostasis. Therefore, radiation-induced NO production, a component of the DDR in ECs, may be involved in CVDs after radiation exposure. In this article, we describe the pathology of radiation-induced CVD and the unique radio-response to radiation exposure in ECs.
Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians
Abstract The new recommendation of the International Commission on Radiological Protection for occupational eye dose is an equivalent dose limit to the eye of 20 mSv year–1, averaged over a 5-year period. This recommendation is a drastic reduction from the previous limit of 150 mSv year–1. Hence, it is important to protect physicians’ eyes from X-ray radiation. Particularly in interventional radiology (IVR) procedures, many physicians use protective lead (Pb) glasses to reduce their occupational exposure. This study assessed the shielding effects of novel 0.07 mm Pb glasses. The novel glasses (XR-700) have Pb–acrylic lens molded in three dimensions. We studied the novel type of 0.07 mm Pb glasses over a period of seven consecutive months. The eye dose occupational radiation exposure of seven IVR physicians was evaluated during various procedures. All IVR physicians wore eye dosimeters (DOSIRIS™) close to the left side of the left eye. To calculate the shielding effects of the glasses, this same type of eye dosimeter was worn both inside and outside of the Pb lenses. The average shielding effect of the novel glasses across the seven physicians was 61.4%. Our results suggest an improved shielding effect for IVR physicians that use these glasses. No physician complained that the new glasses were uncomfortable; therefore comfort is not a problem. The lightweight glasses were acceptable to IVR physicians, who often must perform long procedures. Thus, the novel glasses are comfortable and reasonably protective. Based on the results of this study, we recommend that IVR physicians use these novel 0.07 mm Pb glasses to reduce their exposure.
Development of a headgear-based eye protection device for physicians performing fluoroscopy-guided bronchoscopy
Fluoroscopy-guided bronchoscopy is an essential tool for diagnosing and treating lung diseases, particularly lung cancer. However, prolonged fluoroscopic exposure raises concerns regarding radiation-induced lens injuries in physicians, such as radiation cataracts. In response to the International Commission on Radiological Protection lowering the occupational lens dose limit to an average of 20 mSv/year over 5 years, there is an increasing need for effective lens protection during such procedures. This study has aimed to develop a novel lens protection device specifically designed for bronchoscopy physicians and evaluate its protective performance through a phantom study. The device consisted of a 0.175 mm lead (Pb) sheet positioned on the left side of the physician’s head, secured with headgear to improve stability and comfort during prolonged use. A phantom study was conducted using a trunk phantom to simulate a patient and a head phantom to simulate a physician. The scattered radiation doses were measured at 15 locations on the phantom head using a radiophotoluminescence glass dosimeter, both with and without a protective device. The device demonstrated a protective effect of more than 80% for the left eye across all tested angles, whereas the right eye showed protection ranging from approximately 40% to 75% depending on the angle. This novel lens protection device has the potential to significantly reduce scattered radiation to the left eye while minimizing vision obstruction and discomfort. This offers a practical solution for radiation protection during bronchoscopy and may be applicable to other interventional procedures requiring fluoroscopic guidance.
Occupational radiation exposure of therapists in clinical use of spot scanning proton-carbon ion synchrotron systems
This study addresses the escalating radiation safety concerns among medical professionals due to the rising application of proton and carbon ion radiotherapy. It evaluates the occupational radiation exposure faced by therapists when utilizing the Siemens IONTRIS Proton-Carbon Ion System. Through random sampling of 80 patients treated between January and June 2024, we recorded particle types and counts and measured dose rates using a photon/neutron radiation dose meter. Notably, 1 min post-treatment, the dose rate peaked at 16.00 μSv/h near the tumor's skin surface, showing a significant correlation with particle count. The therapist's standing position and the surfaces of the range shifter and ripple filter registered average dose rates of 1.25 μSv/h and 3.63 μSv/h, 0.33 μSv/h, respectively. Other points averaged 0.08 μSv/h, with no neutron detection. The study concludes that the annual average occupational exposure for therapists, at ~300 μSv, is significantly below the International Commission on Radiological Protection's recommended dose equivalent limit, confirming the safety of the Siemens IONTRIS device in clinical settings.