Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
13,229
result(s) for
"Gait analysis"
Sort by:
A Review of Gait Analysis Using Gyroscopes and Inertial Measurement Units
2025
Wearable sensors are used in gait analysis to obtain spatiotemporal parameters, with gait events serving as critical markers for foot and lower limb movement. Summarizing detection methods is essential, as accurately identifying gait events and phases are key to deriving precise spatiotemporal parameters through wearable technology. However, a clear understanding of how these sensors, particularly angular velocity and acceleration signals within inertial measurement units, individually or collectively, contribute to the detection of gait events and gait phases is lacking. This review aims to summarize the current state of knowledge on the application for both gyroscopes, with particular emphasis on the role of angular velocity signals, and inertial measurement units with both angular velocity and acceleration signals in identifying gait events, gait phases, and calculating gait spatiotemporal parameters. Gyroscopes remain the primary tool for gait events detection, while inertia measurement units enhance reliability and enable spatiotemporal parameter estimation. Rule-based methods are suitable for controlled environments, whereas machine learning offers flexibility to analyze complex gait conditions. In addition, there is a lack of consensus on optimal sensor configurations for clinical applications. Future research should focus on standardizing sensor configurations and developing robust, adaptable detection methodologies suitable for different gait conditions.
Journal Article
Automatic gait EVENT detection in older adults during perturbed walking
by
Wang, Shuaijie
,
Omar, Kazi Shahrukh
,
Bhatt, Tanvi
in
Accidental Falls - prevention & control
,
Adults
,
Aged
2025
Accurate detection of gait events in older adults, particularly during perturbed walking, is essential for evaluating balance control and fall risk. Traditional force plate-based methods often face limitations in perturbed walking scenarios due to the difficulty in landing cleanly on the force plates. Subsequently, previous studies have not addressed gait event automatic detection methods for perturbed walking. This study introduces an automated gait event detection method using a bidirectional gated recurrent unit (Bi-GRU) model, leveraging ground reaction force, joint angles, and marker data, for both regular and perturbed walking scenarios from 307 healthy older adults. Our marker-based model achieved over 97% accuracy with a mean error of less than 14 ms in detecting touchdown (TD) and liftoff (LO) events for both walking scenarios. The results highlight the efficacy of kinematic approaches, demonstrating their potential in gait event detection for clinical settings. When integrated with wearable sensors or computer vision techniques, these methods enable real-time, precise monitoring of gait patterns, which is helpful for applying personalized programs for fall prevention. This work takes a significant step forward in automated gait analysis for perturbed walking, offering a reliable method for evaluating gait patterns, balance control, and fall risk in clinical settings.
Journal Article
Automatic gait events detection with inertial measurement units: healthy subjects and moderate to severe impaired patients
by
Voisard, Cyril
,
Oudre, Laurent
,
Ricard, Damien
in
Accelerometry - instrumentation
,
Accelerometry - methods
,
Adult
2024
Background
Recently, the use of inertial measurement units (IMUs) in quantitative gait analysis has been widely developed in clinical practice. Numerous methods have been developed for the automatic detection of gait events (GEs). While many of them have achieved high levels of efficiency in healthy subjects, detecting GEs in highly degraded gait from moderate to severely impaired patients remains a challenge. In this paper, we aim to present a method for improving GE detection from IMU recordings in such cases.
Methods
We recorded 10-meter gait IMU signals from 13 healthy subjects, 29 patients with multiple sclerosis, and 21 patients with post-stroke equino varus foot. An instrumented mat was used as the gold standard. Our method detects GEs from filtered acceleration free from gravity and gyration signals. Firstly, we use autocorrelation and pattern detection techniques to identify a reference stride pattern. Next, we apply multiparametric Dynamic Time Warping to annotate this pattern from a model stride, in order to detect all GEs in the signal.
Results
We analyzed 16,819 GEs recorded from healthy subjects and achieved an F1-score of 100%, with a median absolute error of 8 ms (IQR [3–13] ms). In multiple sclerosis and equino varus foot cohorts, we analyzed 6067 and 8951 GEs, respectively, with F1-scores of 99.4% and 96.3%, and median absolute errors of 18 ms (IQR [8–39] ms) and 26 ms (IQR [12–50] ms).
Conclusions
Our results are consistent with the state of the art for healthy subjects and demonstrate a good accuracy in GEs detection for pathological patients. Therefore, our proposed method provides an efficient way to detect GEs from IMU signals, even in degraded gaits. However, it should be evaluated in each cohort before being used to ensure its reliability.
Journal Article
Using New Camera-Based Technologies for Gait Analysis in Older Adults in Comparison to the Established GAITRite System
by
Röhling, Hanna
,
Sattler, Igor
,
Mansow-Model, Sebastian
in
Aged
,
Aged, 80 and over
,
Algorithms
2019
Various gait parameters can be used to assess the risk of falling in older adults. However, the state-of-the-art systems used to quantify gait parameters often come with high costs as well as training and space requirements. Gait analysis systems, which use mobile and commercially available cameras, can be an easily available, marker-free alternative. In a study with 44 participants (age ≥ 65 years), gait patterns were analyzed with three different systems: a pressure sensitive walkway system (GAITRite-System, GS) as gold standard, Motognosis Labs Software using a Microsoft Kinect Sensor (MKS), and a smartphone camera-based application (SCA). Intertrial repeatability showed moderate to excellent results for MKS (ICC(1,1) 0.574 to 0.962) for almost all measured gait parameters and moderate reliability in SCA measures for gait speed (ICC(1,1) 0.526 to 0.535). All gait parameters of MKS showed a high level of agreement with GS (ICC(2,k) 0.811 to 0.981). Gait parameters extracted with SCA showed poor reliability. The tested gait analysis systems based on different camera systems are currently only partially able to capture valid gait parameters. If the underlying algorithms are adapted and camera technology is advancing, it is conceivable that these comparatively simple methods could be used for gait analysis.
Journal Article
Accuracy, Validity, and Reliability of Markerless Camera-Based 3D Motion Capture Systems versus Marker-Based 3D Motion Capture Systems in Gait Analysis: A Systematic Review and Meta-Analysis
by
Van den Bussche, Maxime
,
Scataglini, Sofia
,
Truijen, Steven
in
3D marker-based motion capture
,
3D markerless camera-based motion capture
,
Accuracy
2024
(1) Background: Marker-based 3D motion capture systems (MBS) are considered the gold standard in gait analysis. However, they have limitations for which markerless camera-based 3D motion capture systems (MCBS) could provide a solution. The aim of this systematic review and meta-analysis is to compare the accuracy, validity, and reliability of MCBS and MBS. (2) Methods: A total of 2047 papers were systematically searched according to PRISMA guidelines on 7 February 2024, in two different databases: Pubmed (1339) and WoS (708). The COSMIN-tool and EBRO guidelines were used to assess risk of bias and level of evidence. (3) Results: After full text screening, 22 papers were included. Spatiotemporal parameters showed overall good to excellent accuracy, validity, and reliability. For kinematic variables, hip and knee showed moderate to excellent agreement between the systems, while for the ankle joint, poor concurrent validity and reliability were measured. The accuracy and concurrent validity of walking speed were considered excellent in all cases, with only a small bias. The meta-analysis of the inter-rater reliability and concurrent validity of walking speed, step time, and step length resulted in a good-to-excellent intraclass correlation coefficient (ICC) (0.81; 0.98). (4) Discussion and conclusions: MCBS are comparable in terms of accuracy, concurrent validity, and reliability to MBS in spatiotemporal parameters. Additionally, kinematic parameters for hip and knee in the sagittal plane are considered most valid and reliable but lack valid and accurate measurement outcomes in transverse and frontal planes. Customization and standardization of methodological procedures are necessary for future research to adequately compare protocols in clinical settings, with more attention to patient populations.
Journal Article
Clinical gait analysis 1973–2023: Evaluating progress to guide the future
by
Stewart, Caroline
,
Stebbins, Julie
,
Harrington, Marian
in
Algorithms
,
Automation
,
Biomechanical engineering
2023
Clinical gait analysis has been used to inform treatment for over 50 years. Over that period there have been significant advances in motion capture technology and software development, driven in part by innovations in biomechanics. The aim of this paper is to review the current state of the art in gait analysis, mapping progress over the last five decades using the collective experience of the community of researchers and clinicians.An online survey was circulated to gait analysts to canvas opinion and responses were received from 229 people from 28 countries.Respondents identified the greatest progress in the areas of hardware, automation of processes, and software development. Despite laboratories being better equipped, many of today’s challenges would have been very familiar to those working in 1973. Better algorithms and more evidence are needed to establish a secure link between gait analysis data and clinical decision making. Biomechanical models require further refinement to overcome well known limitations. Despite innovation, clinical gait analysis remains relatively unknown in the wider healthcare field.Growth in the global Gait Analysis communities and advances in remote communication technology have created new opportunities for taking on this challenge over the next 50 years. Hopefully, future innovation will lead to clinical gait analysis becoming more accessible, more flexible to real world mobility and more able to exploit emerging advanced modelling techniques.
Journal Article
Canine gait analysis using inertial sensors and deep learning for orthopedic and neurological disorders
2026
Canine gait analysis using wearable inertial sensors is gaining attention in veterinary clinical settings, as it provides valuable insights into a range of mobility impairments. Neurological and orthopedic conditions cannot always be easily distinguished even by experienced clinicians. The current study explored and developed a deep learning approach using inertial sensor readings to assess whether neurological and orthopedic gait could facilitate gait analysis. Our investigation focused on optimizing both performance and generalizability in distinguishing between these gait abnormalities. Variations in sensor configurations, assessment protocols, and enhancements to deep learning model architectures were further suggested. Using a dataset of 29 dogs, our proposed approach achieved 0.96 accuracy in the multiclass classification task (healthy/orthopedic/neurological) and 0.85 accuracy in the binary classification task (healthy/non-healthy) when generalizing to unseen dogs. Our results demonstrate the potential of inertial-based deep learning models to serve as a practical and objective diagnostic and clinical aid to differentiate gait assessment in orthopedic and neurological conditions.
Journal Article
Automated Gait Analysis Based on a Marker-Free Pose Estimation Model
by
Gan, Kok Beng
,
Mohamed Ibrahim, Norlinah
,
Zainal, Nasharuddin
in
Accuracy
,
Algorithms
,
Analysis
2023
Gait analysis is an essential tool for detecting biomechanical irregularities, designing personalized rehabilitation plans, and enhancing athletic performance. Currently, gait assessment depends on either visual observation, which lacks consistency between raters and requires clinical expertise, or instrumented evaluation, which is costly, invasive, time-consuming, and requires specialized equipment and trained personnel. Markerless gait analysis using 2D pose estimation techniques has emerged as a potential solution, but it still requires significant computational resources and human involvement, making it challenging to use. This research proposes an automated method for temporal gait analysis that employs the MediaPipe Pose, a low-computational-resource pose estimation model. The study validated this approach against the Vicon motion capture system to evaluate its reliability. The findings reveal that this approach demonstrates good (ICC(2,1) > 0.75) to excellent (ICC(2,1) > 0.90) agreement in all temporal gait parameters except for double support time (right leg switched to left leg) and swing time (right), which only exhibit a moderate (ICC(2,1) > 0.50) agreement. Additionally, this approach produces temporal gait parameters with low mean absolute error. It will be useful in monitoring changes in gait and evaluating the effectiveness of interventions such as rehabilitation or training programs in the community.
Journal Article
Concurrent validity of smartphone-based markerless motion capturing to quantify lower-limb joint kinematics in healthy and pathological gait
2023
Markerless motion capturing has the potential to provide a low-cost and accessible alternative to traditional marker-based systems for real-world biomechanical assessment. However, before these systems can be put into practice, we need to rigorously evaluate their accuracy in estimating joint kinematics for various gait patterns. This study evaluated the accuracy of a low-cost, open-source, and smartphone-based markerless motion capture system, namely OpenCap, for measuring 3D joint kinematics in healthy and pathological gait compared to a marker-based system. 21 healthy volunteers were instructed to walk with four different gait patterns: physiological, crouch, circumduction, and equinus gait. Three-dimensional kinematic data were simultaneously recorded using the markerless and a marker-based motion capture system. The root mean square error (RMSE) and the peak error were calculated between every joint kinematic variable obtained by both systems. We found an overall RMSE of 5.8 (SD: 1.8 degrees) and a peak error of 11.3 degrees (SD: 3.9). A repeated measures ANOVA with post hoc tests indicated significant differences in RMSE and peak errors between the four gait patterns (p ¡ 0.05). Physiological gait presented the lowest, crouch and circumduction gait the highest errors. Our findings indicate a roughly comparable accuracy to IMU-based approaches and commercial markerless multi-camera solutions. However, errors are still above clinically desirable thresholds of two to five degrees. While our findings highlight the potential of markerless systems for assessing gait kinematics, they also underpin the need to further improve the underlying deep learning algorithms to make markerless pose estimation a valuable tool in clinical settings.
Journal Article
Smartphone-based gait analysis in the assessment of fatigue and fatigability in people with multiple sclerosis: a supervised cohort study
2025
Background
Gait impairments and fatigue are the most common and disabling symptoms in people with multiple sclerosis (PwMS). Objective 6-min walk test (6MWT) gait testing can be improved through body-worn accelerometers, but its association to subjective fatigue and objective fatigability is contradictory. This study aims to validate an algorithm using smartphone sensor data for spatial–temporal gait parameters in PwMS and healthy controls, and evaluate its accuracy in detecting fatigability, and quantify its association with fatigue in PwMS.
Methods
We recruited PwMS with mild to moderate disability (EDSS 0.0–6.5) and healthy controls in a supervised, lab-based cohort study. All participants performed the 6MWT while wearing a smartphone at the hip, which collected acceleration data of step count, cadence and walking speed. Algorithm validation included the mean absolute percentage error (MAPE) and Bland–Altman analysis. Fatigability and fatigue were measured in PwMS, with fatigability defined as a 10% decline in gait performance, and fatigue using the fatigue scale for motor and cognitive functions (FSMC). Further, correlations between gait parameters and FSMC were assessed.
Results
A total of 38 PwMS and 24 healthy controls were included. The algorithm demonstrated high validity for step count (MAPE < 3%) and cadence (MAPE < 10%). Gait analyses revealed fatigability in between 2.6 and 15.8% of PwMS, with large differences between the gait parameter assessed. Significant correlations were found especially between FSMC motor fatigue scores and step count (
r
= − 0.50), cadence (
r
= 0.51) and walking speed (
r
= 0.50).
Conclusion
Smartphone-based gait analysis provides an accessible and valid method for detecting steps and cadence. There are major differences in the assessment of fatigability, but an allover association to subjective motor fatigue.
Journal Article