Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
1,061
result(s) for
"Head kinematics"
Sort by:
Development of a Second-Order System for Rapid Estimation of Maximum Brain Strain
by
Panzer, Matthew B
,
Gabler, Lee F
,
Crandall, Jeff R
in
Angular acceleration
,
Brain damage
,
Brain injury
2019
Diffuse brain injuries are assessed with deformation-based criteria that utilize metrics based on rotational head kinematics to estimate brain injury severity. Although numerous metrics have been proposed, many are based on empirically-derived models that use peak kinematics, which often limit their applicability to a narrow range of head impact conditions. However, over a broad range of impact conditions, brain deformation response to rotational head motion behaves similarly to a second-order mechanical system, which utilizes the full kinematic time history of a head impact. This study describes a new brain injury metric called Diffuse Axonal Multi-Axis General Evaluation (DAMAGE). DAMAGE is based on the equations of motion of a three-degree-of-freedom, coupled 2nd-order system, and predicts maximum brain strain using the directionally dependent angular acceleration time-histories from a head impact. Parameters for the effective mass, stiffness, and damping were determined using simplified rotational pulses which were applied multiaxially to a 50th percentile adult human male finite element model. DAMAGE was then validated with a separate database of 1747 head impacts including helmet, crash, and sled tests and human volunteer responses. Relative to existing rotational brain injury metrics that were evaluated in this study, DAMAGE was found to be the best predictor of maximum brain strain.
Journal Article
Consensus Head Acceleration Measurement Practices (CHAMP): Origins, Methods, Transparency and Disclosure
by
Solomon, Gary
,
Funk, James R
,
Buckley, Thomas A
in
Acceleration measurement
,
Accelerometers
,
Attention
2022
The use of head kinematic measurement devices has recently proliferated owing to technology advances that make such measurement more feasible. In parallel, demand to understand the biomechanics of head impacts and injury in sports and the military has increased as the burden of such loading on the brain has received focused attention. As a result, the field has matured to the point of needing methodological guidelines to improve the rigor and consistency of research and reduce the risk of scientific bias. To this end, a diverse group of scientists undertook a comprehensive effort to define current best practices in head kinematic measurement, culminating in a series of manuscripts outlining consensus methodologies and companion summary statements. Summary statements were discussed, revised, and voted upon at the Consensus Head Acceleration Measurement Practices (CHAMP) Conference in March 2022. This manuscript summarizes the motivation and methods of the consensus process and introduces recommended reporting checklists to be used to increase transparency and rigor of future experimental design and publication of work in this field. The checklists provide an accessible means for researchers to apply the best practices summarized in the companion manuscripts when reporting studies utilizing head kinematic measurement in sport and military settings.
Journal Article
Assessment of Kinematic Brain Injury Metrics for Predicting Strain Responses in Diverse Automotive Impact Conditions
by
Gabler, Lee F.
,
Panzer, Matthew B.
,
Crandall, Jeff R.
in
Acceleration
,
Accidents, Traffic
,
Biochemistry
2016
Numerous injury criteria have been developed to predict brain injury using the kinematic response of the head during impact. Each criterion utilizes a metric that is some mathematical combination of the velocity and/or acceleration components of translational and/or rotational head motion. Early metrics were based on linear acceleration of the head, but recent injury criteria have shifted towards rotational-based metrics. Currently, there is no universally accepted metric that is suitable for a diverse range of head impacts. In this study, we assessed the capability of fifteen existing kinematic-based metrics for predicting strain-based brain response using four different automotive impact conditions. Tissue-level strains were obtained through finite element model simulation of 660 head impacts including occupant and pedestrian crash tests, and pendulum head impacts. Correlations between head kinematic metrics and predicted brain strain-based metrics were evaluated. Correlations between brain strain and metrics based on angular velocity were highest among those evaluated, while metrics based on linear acceleration were least correlative. BrIC and RVCI were the kinematic metrics with the highest overall correlation; however, each metric had limitations in certain impact conditions. The results of this study suggest that rotational head kinematics are the most important parameters for brain injury criteria.
Journal Article
Development, Validation and Pilot Field Deployment of a Custom Mouthpiece for Head Impact Measurement
by
Rich, Andrea M
,
Urban, Jillian E
,
Tomblin, Brian T
in
Angular acceleration
,
Angular velocity
,
Center of gravity
2019
The objective of this study was to develop a mouthpiece sensor with improved head kinematic measurement for use in non-helmeted and helmeted sports through laboratory validation and pilot field deployment in female youth soccer. For laboratory validation, data from the mouthpiece sensor was compared to standard sensors mounted in a headform at the center of gravity as the headform was struck with a swinging pendulum. Linear regression between peak kinematics measured from the mouthpiece and headform showed strong correlation, with r2 values of 0.95 (slope = 1.02) for linear acceleration, 1.00 (slope = 1.00) for angular velocity, and 0.97 (slope = 0.96) for angular acceleration. In field deployment, mouthpiece data were collected from four female youth soccer players and time-synchronized with film. Film-verified events (n = 915) were observed over 9 practices and 5 games, and 632 were matched to a corresponding mouthpiece event. This resulted in an overall sensitivity of 69.2% and a positive predictive value of 80.3%. This validation and pilot field deployment data demonstrates that the mouthpiece provides highly accurate measurement of on-field head impact data that can be used to further study the effects of impact exposure in both helmeted and non-helmeted sports.
Journal Article
On-Field Performance of an Instrumented Mouthguard for Detecting Head Impacts in American Football
by
Huddleston, Samuel H
,
Lessley, David J
,
Resch, Jacob E
in
Accelerometers
,
Athletes
,
Classification
2020
Wearable sensors that accurately record head impacts experienced by athletes during play can enable a wide range of potential applications including equipment improvements, player education, and rule changes. One challenge for wearable systems is their ability to discriminate head impacts from recorded spurious signals. This study describes the development and evaluation of a head impact detection system consisting of a mouthguard sensor and machine learning model for distinguishing head impacts from spurious events in football games. Twenty-one collegiate football athletes participating in 11 games during the 2018 and 2019 seasons wore a custom-fit mouthguard instrumented with linear and angular accelerometers to collect kinematic data. Video was reviewed to classify sensor events, collected from instrumented players that sustained head impacts, as head impacts or spurious events. Data from 2018 games were used to train the ML model to classify head impacts using kinematic data features (127 head impacts; 305 non-head impacts). Performance of the mouthguard sensor and ML model were evaluated using an independent test dataset of 3 games from 2019 (58 head impacts; 74 non-head impacts). Based on the test dataset results, the mouthguard sensor alone detected 81.6% of video-confirmed head impacts while the ML classifier provided 98.3% precision and 100% recall, resulting in an overall head impact detection system that achieved 98.3% precision and 81.6% recall.
Journal Article
Characterizing Exposure to Head Acceleration Events in Youth Football Using an Instrumented Mouthpiece
2022
Understanding characteristics of head acceleration events (HAEs) in youth football is vital in developing strategies to improve athlete safety. This study aimed to characterize HAEs in youth football using an instrumented mouthpiece. Youth football athletes (ages 11–13) participating on two teams were enrolled in this study for one season. Each athlete was instrumented with a mouthpiece-based sensor throughout the season. HAEs were verified on film to ensure that mouthpiece-based sensors triggered during contact. The number of HAEs, peak resultant linear and rotational accelerations, and peak resultant rotational velocity were quantified. Mixed effects models were used to evaluate differences in mean kinematic metrics among all HAEs for session type, athlete position, and contact surface. A total of 5,292 HAEs were collected and evaluated from 30 athletes. The median (95th percentile) peak resultant linear acceleration, rotational acceleration, and rotational velocity was 9.5 g (27.0 g), 666.4 rad s−2 (1863.3 rad s−2), and 8.5 rad s−1 (17.4 rad s−1), respectively. Athletes experienced six (22) HAEs per athlete per session (i.e., practice, game). Competition had a significantly higher mean number of HAEs per athlete per session and mean peak rotational acceleration. Peak resultant rotational kinematics varied significantly among athlete positions. Direct head impacts had higher mean kinematics compared to indirect HAEs, from body collisions. The results of this study demonstrate that session type, athlete position, and contact surface (i.e., direct, indirect) may influence HAE exposure in youth football.
Journal Article
Head and pelvis are the key segments recruited by adult spinal deformity patients during daily life activities
by
Chaaya, Celine
,
Rachkidi, Rami
,
Assi, Ayman
in
3D movement analysis
,
639/166/985
,
692/4023/1671/63
2024
Functional assessment is a key element in evaluating adult spinal deformity (ASD) patients. The multitude of 3D kinematic parameters provided by movement analysis can be confusing for spine surgeons. The aim was to investigate movement patterns of ASD based on key kinematic parameters. 115 primary ASD and 36 controls underwent biplanar radiographs and 3D movement analysis during walking, sit-to-stand and stair ascent to calculate joint and segment kinematics. Principal component analysis was applied to identify the most relevant kinematic parameters that define movement strategies adopted by ASD. Pelvis and head relative to pelvis kinematics were the most relevant parameters. ASD patients adopted four different movement strategies. Class 1: normative head and pelvis kinematics. Class 2: persistent pelvic backward tilt. Class 3: persistent forward shift of the head. Class 4: both pelvic backward tilt and forward shift of the head. Patients in class 3 and 4 presented sagittal malalignment on static radiographs with increased pelvic tilt, pelvic incidence-lumbar lordosis mismatch and sagittal vertical axis. Surprisingly, patients in class 3 had normal pelvic kinematics during movement, showing the importance of functional evaluation. In addition to being key segments in maintaining static global posture, head and pelvis were found to define movement patterns.
Journal Article
An Instrumented Mouthguard for Real-Time Measurement of Head Kinematics under a Large Range of Sport Specific Accelerations
by
Augustus, Simon N.
,
Baker, Claire
,
Loosemore, Mike
in
Biomechanics
,
Chronic traumatic encephalopathy
,
Football
2023
Background: Head impacts in sports can produce brain injuries. The accurate quantification of head kinematics through instrumented mouthguards (iMG) can help identify underlying brain motion during injurious impacts. The aim of the current study is to assess the validity of an iMG across a large range of linear and rotational accelerations to allow for on-field head impact monitoring. Methods: Drop tests of an instrumented helmeted anthropometric testing device (ATD) were performed across a range of impact magnitudes and locations, with iMG measures collected concurrently. ATD and iMG kinematics were also fed forward to high-fidelity brain models to predict maximal principal strain. Results: The impacts produced a wide range of head kinematics (16–171 g, 1330–10,164 rad/s2 and 11.3–41.5 rad/s) and durations (6–18 ms), representing impacts in rugby and boxing. Comparison of the peak values across ATD and iMG indicated high levels of agreement, with a total concordance correlation coefficient of 0.97 for peak impact kinematics and 0.97 for predicted brain strain. We also found good agreement between iMG and ATD measured time-series kinematic data, with the highest normalized root mean squared error for rotational velocity (5.47 ± 2.61%) and the lowest for rotational acceleration (1.24 ± 0.86%). Our results confirm that the iMG can reliably measure laboratory-based head kinematics under a large range of accelerations and is suitable for future on-field validity assessments.
Journal Article
On-Field Evaluation of Mouthpiece-and-Helmet-Mounted Sensor Data from Head Kinematics in Football
2024
Purpose
Wearable sensors are used to measure head impact exposure in sports. The Head Impact Telemetry (HIT) System is a helmet-mounted system that has been commonly utilized to measure head impacts in American football. Advancements in sensor technology have fueled the development of alternative sensor methods such as instrumented mouthguards. The objective of this study was to compare peak magnitude measured from high school football athletes dually instrumented with the HIT System and a mouthpiece-based sensor system.
Methods
Data was collected at all contact practices and competitions over a single season of spring football. Recorded events were observed and identified on video and paired using event timestamps. Paired events were further stratified by removing mouthpiece events with peak resultant linear acceleration below 10 g and events with contact to the facemask or body of athletes.
Results
A total of 133 paired events were analyzed in the results. There was a median difference (mouthpiece subtracted from HIT System) in peak resultant linear and rotational acceleration for concurrently measured events of 7.3 g and 189 rad/s
2
. Greater magnitude events resulted in larger kinematic differences between sensors and a Bland Altman analysis found a mean bias of 8.8 g and 104 rad/s
2
, respectively.
Conclusion
If the mouthpiece-based sensor is considered close to truth, the results of this study are consistent with previous HIT System validation studies indicating low error on average but high scatter across individual events. Future researchers should be mindful of sensor limitations when comparing results collected using varying sensor technologies.
Journal Article
Relationship Between Rotational Device Kinematics and Head Kinematics in a Large Animal Model of Traumatic Brain Injury
by
McQuaid, Jessica R.
,
Dodd, Andrew B.
,
Kinsler, Rachel E.
in
Accelerometers
,
Angular acceleration
,
Angular velocity
2025
Large mammal head injury models allow the pathophysiological response associated with traumatic brain injury (TBI) to be studied in vivo with precise control of the physical parameters. However, only some studies have used skull-mounted sensors to measure the kinematics of the animal head rather than relying on measurements of the system delivering the impact. Therefore, the aim of the current study was to compare the kinematics between a rotational injury device (HYGE, Inc., Kittanning, PA) and the head in a swine model of TBI across a range of target peak angular velocities.
Sexually mature Yucatan swine were subjected to a rotational TBI via the HYGE device at one of three targeted peak angular velocities: 110 rad/s (n = 16), 145 rad/s (n = 12) or 170 rad/s (n = 11). Sensor packages were used to measure both the angular kinematics of the animal head and HYGE device swing arm.
Peak angular velocity of the animal head was on average 18-33% lower compared to that of the HYGE device swing arm with greater relative differences for greater target peak angular velocities. Similarly, peak angular acceleration of the animal head was lower than that of the HYGE device sing arm by 11-34% on average with greater relative differences for greater target peak angular velocities.
This study highlights the importance of directly measuring the head kinematics of the animal in TBI models for the purpose of directional comparisons, finite element simulations, and/or scaling kinematics from human-to-animal to determine boundary conditions or animal-to-human to develop injury criteria.
Journal Article