Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Series TitleSeries Title
-
Reading LevelReading Level
-
YearFrom:-To:
-
More FiltersMore FiltersContent TypeItem TypeIs Full-Text AvailableSubjectPublisherSourceDonorLanguagePlace of PublicationContributorsLocation
Done
Filters
Reset
19,794
result(s) for
"Heating systems"
Sort by:
Interval optimal scheduling of integrated electricity and district heating systems considering dynamic characteristics of heating network
by
Chen, Houhe
,
Zhang, Rufeng
,
Jiang, Tao
in
12‐node district heating system
,
6‐node district heating system
,
Algorithms
2020
Coordinated operation of integrated electricity and district heating system (IEDHS) has great potential to enhance the flexibility of the power system to cope with the wind power curtailment. This study proposes an interval optimal scheduling algorithm for IEDHSs, considering the dynamic characteristics of the heating network. The model of the district heating system with dynamic characteristics including transmission delay and heat losses, is established in detail, and the uncertainties of both wind power and electricity and heating loads are described with interval numbers. Then an interval optimal scheduling model of the IEDHS is formulated to minimise the IEDHS operation cost. The impacts of the transmission delay and heat losses of the heating network on the scheduling of the IEDHS are analysed. Case studies are performed on the PJM 5‐bus electricity system with a 6‐node district heating system and IEEE 39‐bus electricity system with a 12‐node district heating system to evaluate the effectiveness of the proposed model. The results demonstrate that the dynamic characteristics of the heating network can integrate more wind power and enlarge the width of the cost interval.
Journal Article
Return-Temperature Reduction at District Heating Systems: Focus on End-User Sites
2024
This review presents a comprehensive examination of recent advancements and findings related to return-temperature reduction in District Heating (DH) systems, with a focus on enhancing overall system efficiency at end-user sites. The review categorizes and clarifies various return-temperature reduction techniques, emphasizing aspects such as building energy performance, heat emitters, thermostatic radiator valves, and substation units. One shall note that return temperature is not a parameter that can be directly controlled within a DH system; instead, it is influenced indirectly by adjusting various system parameters throughout the design, commissioning, operation, and control phases. Key insights include the direct impact of heat demand on return temperatures; the pivotal role of indoor heating systems in optimizing thermal energy use in relation to heat demand; the significance of thermostatic radiator valves in regulating heat output and maintaining low return temperatures; the advantages of ventilation radiators and add-on fans in enhancing radiator efficiency; the necessity for effective substation operation to improve system cooling capacity; and the critical role of operational control strategies in achieving optimal system performance. These findings underscore the need for integrated approaches in DH system design and operation to achieve lower return temperatures and improve overall system efficiency.
Journal Article
Evaluating the integration of apartment building heating systems with low-temperature district heating networks
by
Misevičiūtė, Violeta
,
Bielskus, Juozas
,
Streckienė, Giedrė
in
Apartment buildings
,
Apartments
,
building modernization
2025
Any renovation of apartment buildings by replacing or keeping their heating devices usually means that high temperatures of the heat carrier are maintained, which restricts boosting the efficiency of a central heating supply system. This also limits the scope for a switch to more efficient systems such as low-temperature district heating systems. To assess the impact of reducing the heat carrier temperature on indoor heating with a constant radiator area, the article investigates several alternatives alongside a base case scenario. In one scenario, the modernization of a building is examined, either by retaining the current heating devices or by substituting them with devices of equal size. Another scenario explores the modernization of a building by exchanging the heating devices and adjusting the building’s heating system to accommodate ultra-low temperatures. The possibility to reduce the temperature of the heat carrier in the heating system without any renovation of the building has been addressed as well. This led to seven alternatives. The analysis of the hourly data of the heating system model for two typical months in a heating season has revealed that when the building retains its existing area of heating devices post-renovation, the temperature can be brought down to 60/40/20 °C. It was also discovered that lowering the heat transfer temperature to ultra-low parameters (45/25/20 °C) cannot be achieved by refurbishing the buildings without increasing the number of radiators, as the heating devices will fail to deliver adequate heat for space heating.
Article in English.
Daugiabučių namų šildymo sistemų integravimo į žemos temperatūros centralizuoto šilumos tiekimo tinklus vertinimas
Santrauka
Daugiabučių namų renovacija, keičiant ar paliekant jų šildymo prietaisus, paprastai reiškia, kad reikia išlaikyti aukštą šilumnešio temperatūrą, o tai riboja centralizuoto šilumos tiekimo (CŠT) sistemos efektyvumo didinimą. Be to, tai apriboja galimybę pereiti prie efektyvesnių sistemų, pavyzdžiui, žematemperatūrių CŠT sistemų. Siekiant įvertinti sumažintos šilumnešio temperatūros poveikį patalpoms šildyti, kai radiatorių plotas išlieka pastovus, straipsnyje išnagrinėtos kelios alternatyvos ir bazinis scenarijus. Pagal vieną scenarijų nagrinėjamas pastato modernizavimas, paliekant esamus šildymo prietaisus arba pakeičiant juos tokio pat dydžio prietaisais. Pagal kitą scenarijų nagrinėjamas pastato modernizavimas pakeičiant šildymo prietaisus ir pritaikant pastato šildymo sistemą itin žemai temperatūrai. Taip pat nagrinėta galimybė sumažinti šilumnešio temperatūrą šildymo sistemoje neatnaujinant pastato. Tai leido parengti septynias alternatyvas. Išanalizavus šildymo sistemos modelio valandinius dviejų tipinių šildymo sezono mėnesių duomenis paaiškėjo, kad, po renovacijos pastate išlaikant esamą šildymo prietaisų plotą, temperatūrą galima sumažinti iki 60/40/20 °C. Taip pat nustatyta, kad renovuojant pastatus neįmanoma sumažinti šilumos perdavimo temperatūros iki itin žemų parametrų (45/25/20 °C) nekeičiant esamo radiatorių skaičiaus, nes šildymo prietaisai nesugebės tiekti pakankamai šilumos patalpoms šildyti.
Reikšminiai žodžiai: centralizuotas šilumos tiekimas (CŠT), pastatų modernizavimas, šildymo sistema, žema temperatūra.
Journal Article
Coordinated Reconfiguration with Energy Storage System for Load Restoration in Integrated Electric and Heating Systems
2024
Coordinated load restoration of integrated electric and heating systems (IEHSs) has become indispensable following natural disasters due to the increasingly relevant integration between power distribution systems (PDS) and district heating systems (DHS). In this paper, a coordinated reconfiguration with an energy storage system is introduced to optimize load restoration in the aftermath of natural catastrophes. By modifying the DHS network topology, it is possible to maintain an uninterrupted energy supply in unfaulty zones by shifting heat loads among sources and adjusting the operation of coupled devices. Additionally, energy storage systems with rapid response times are implemented to enhance load restoration efficiency, especially when working in conjunction with multiple energy sources. Comprehensive case analyses have been systematically conducted to demonstrate the impact of coordinated reconfiguration with energy storage systems on improving load restoration.
Journal Article
Young’s Modulus Variation of the Deformable Cement Adhesives Under Thermal Action in LRHS
2025
Young’s modulus (E), one of the many material properties, changes in response to thermal actions. The magnitude of these changes also depends on the material used. This is particularly important when the materials used are components of lightweight radiant heating systems (LRHSs) without screeds. Adhesives or adhesive composites take over the role of the screed in LRHSs. The adhesives, which directly connect the thermal insulation layer and the floor, are responsible for the proper functioning of the heated floor. Therefore, changes in their Young’s modulus cause a loss of layer integrity and ultimately delamination of the floor. Thus, research was conducted on the variation of the Young’s modulus of deformable cement adhesive mortars, specifically types C2S1 and C2S2, used in LRHSs under thermal actions. The deformation values of adhesive mortar samples were measured in a thermal chamber, subjected to compressive strength tests, at temperatures from 30 °C to 50 °C. Deformation measurements of heated samples were performed using the extensometer technique. The measurement results were subjected to mathematical analysis using polynomial regression based on the least squares method and the “Madrid parabola” formulas. After analysis, it was assumed that the Young’s modulus E for the deformable C2S1 cement adhesive, depending on the thermal action taken in the study, falls within the range of 4600 MPa to 5800 MPa when the temperature is varied from 30 °C to 50 °C. Simultaneously, the Young’s modulus E remains constant over these temperatures, at 2300 MPa for the C2S2 adhesive. Knowledge of the Young’s modulus and other strength parameters of adhesive mortars connecting layers of lightweight heated floors or other partitions, subjected to temperature can directly impact their durability. This data can be used to analyse the performance of LRHSs and numerical calculation techniques for various building partitions, such as stairs, balconies, and terraces.
Journal Article
Design and experimentation on domestic solar water heaters using kenics twist inserts
by
J, Suganthi
,
Jaisankar, S.
,
Ananth, J.
in
Analytical Chemistry
,
Chemistry
,
Chemistry and Materials Science
2023
Passive thermal augmentation is preferred in the design of compact and energy efficient domestic solar water heating systems (DSWH). Current study investigates the impact of modified DSWH with Kenics insert brazed with rod and spacer sequentially on the heat augmentation, and flow pressure, and frictional attributes. The thermal performance and flow friction characteristics have also been analyzed for different rod and spacer lengths such as 0.125, 0.25, and 0.5 m for twist designed with a stable twist ratio of 3. Experimental results reveal the drop in Nusselt number when the rod and the spacer span increase; and the flow pressure drop (Δ
P
) decreases significantly while extending the same in comparison with full kenics twist. Further, the increment in pressure drop and heat removal was observed significantly in twist and rod inserts of minimum twist ratio and rod length compared to twist and spacer combination. Interrelationships developed for Nusselt number (Nu) and Friction factor (ft) show close agreement between estimated and experimental values.
Journal Article
Experimental and Numerical Analysis of Temperature Reduction Potentials in the Heating Supply of an Unrenovated University Building
by
Sauerwein, David
,
Fitzgerald, Niall
,
Kuhn, Christoph
in
Air quality management
,
Alternative energy sources
,
Asymmetry
2023
Lowering the temperatures in heating systems is the key to decarbonizing the heat supply in the building sector, because it is a door opener to greater integration of renewable heat, the use of excess heat and to improve compatibility for heat pumps. This often fails because heating systems, especially in unrenovated building stock, usually require high supply temperatures. Previous studies on temperature reduction in existing buildings are performed mainly numerically, whereas in this research the numeric calculations are validated by measurements. For this purpose, a demonstrator with two different ceiling heating systems is integrated in the listed architecture building of the Technical University of Darmstadt and the achievable temperature reduction is investigated. Based on this, parameter variations are conducted through a simulation model in order to test the feasibility of the concept for the entire building. The results show that even with an unrenovated building envelope, a significant temperature reduction to below 45 °C is possible without exceeding the normative limits of thermal comfort. With moderate building envelope renovation, the reduction is possible even to below 36 °C. The measures investigated can make the building compatible with renewable heat potentials without negative impacts on the cultural heritage.
Journal Article
Role of thermal technologies for enhancing flexibility in multi‐energy systems through sector coupling: technical suitability and expected developments
2020
Thermal power generation technologies are widely used for electricity production, for heat provision in district or process heating systems, and for combined heat and power generation. In most cases, thermal technologies are heat driven and electricity is produced as a by‐product, thus resulting in a non‐flexible behaviour of the electricity production. Modern power grids are characterised by an increasing share of renewable leading to a need for enhanced and flexible ways of controlling the power flow. To provide services to the power grid, thermal generating technologies may be used in a more efficient way, coupled to gas and heat storage systems or aggregated in virtual power plants. Several technical factors determine which technologies are suitable for flexibility provision, including power ranges, start up times and ramp rates. In this work, carried out in the frame of the MAGNITUDE H2020 project, the technical characteristics of thermal sector‐coupling technologies were analysed using data from the seven real‐life project's case studies. The technical suitability was determined based on the product requirements in selected European power markets for the provision of identified system services. Expected future developments and trends were highlighted well.
Journal Article