Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
55,639 result(s) for "Hemodynamics"
Sort by:
E-195 Hemodynamic changes in the anterior cerebral artery after flow diversion: proof-of-concept computational study
BackgroundThis study analyzed hemodynamic changes in a single patient case following flow diverter-assisted coiling of an ICA bifurcation aneurysm. The stent was deployed toward the M1 segment of the MCA, jailing and reducing blood flow through the A1 segment of the ACA. Here, we used a computational fluid dynamics (CFD) algorithm to quantify ACA flow reduction post-stent deployment and assessed its hemodynamic implications proximally and in distal territories.MethodsAnalysis was conducted using Dr. NEAR flow (Seoul, KR), a software integrated from 3D reconstruction to cerebral vascular hemodynamics. CTA scans from a patient who underwent flow diverter stent placement were used to reconstruct a three-dimensional vascular model. A one-dimensional network model consisting of nodes and edges was generated to represent cerebral circulation (figure 1a). To simulate hemodynamic changes due to stent placement, the diameter of the first node at the ACA bifurcation was progressively reduced to mimic the decrease in cross-sectional area. This area was estimated by averaging the diameters of the first two bifurcation nodes. Using the software’s computational module, blood flow, pressure, and velocity were calculated assuming an ICA inflow of 3 mL/s, and their relationship to cross-sectional area reduction was analyzed.ResultsA 10% stepwise reduction in the first node diameter led to cross-sectional area decreases of 17%, 32%, 46%, and 58% (figure 1b). As cross-sectional area increased, ACA blood flow and pressure increased, while velocity decreased. These results suggest that changes in bifurcation from stent placement significantly impacted hemodynamics.ConclusionWithout knowing the exact stent porosity, we observed that a reduction in cross-sectional area at the ACA bifurcation decreased blood flow and pressure while increasing velocity in the jailed ACA segment. These findings suggest that stent placement alters hemodynamics, which could impact perfusion. Future studies should consider stent mesh design to predict postoperative hemodynamic changes, aiding surgical planning and outcome prediction based on deep learning processes with a clinical dataset.Abstract E-195 Figure 1DisclosuresA. Wu: None. W. Lee: 5; C; NEAR Brain, Inc.. P. Davis: None. K. Scott: None. T. Lee: 5; C; NEAR Brain, Inc. V. Srinivasan: 1; C; Zeiss, Siemens, Medtronic, Stryker. 2; C; Cerenovus, Stryker, Imperative Care, National Football League.
ESRA19-0075 Effect of prophylactic intravenous ondansetron on maternal hemodynamics during elective lscs
Background and aimsThe Bezold Jarisch Reflex (BJR) is considered to contribute to subarachnoid block (SAB) induced hypotension and bradycardia and is mediated by serotonin receptors (5-HT3 subtype). Ondansetron, a 5-HT3 receptor antagonist is assumed to block the effect of serotonin and inhibit the BJR. the aim was to study the effect of intravenous ondansetron on maternal hemodynamics.Methods150 healthy parturients scheduled for elective caesarean section were randomly allocated into two groups of 75 each to receive either 4 mg ondansetron diluted to 10 ml of 0.9% normal saline or 10 ml of 0.9% normal saline 10 minutes before initiation of SAB. Haemodynamic parameters were studied from time of administration of the study drug up to the time of delivery.ResultsBoth the groups were comparable to each other with respect to baseline haemodynamic parameters. SAB induced fall in SBP, DBP and MAP was significantly less in the ondansetron group as compared to placebo from the time of initiation of SAB up to 12 minutes of surgery time (p<0.05). However, the difference in HR between both the groups was not statistically significant. the total use of vasopressors was less in ondansetron group as compared to placebo (p<0.05). Better neonatal outcomes were observed in the ondansetron group.ConclusionsIntravenous ondansetron premedication can successfully attenuate SAB induced fall in SBP, DBP and MAP in parturients undergoing elective cesarean sections.
Fluid balance neutralization secured by hemodynamic monitoring versus protocolized standard of care in patients with acute circulatory failure requiring continuous renal replacement therapy: results of the GO NEUTRAL randomized controlled trial
PurposeNet ultrafiltration (UFNET) during continuous renal replacement therapy (CRRT) can control fluid balance (FB), but is usually 0 ml·h−1 in patients with vasopressors due to the risk of hemodynamic instability associated with CRRT (HIRRT). We evaluated a UFNET strategy adjusted by functional hemodynamics to control the FB of patients with vasopressors, compared to the standard of care.MethodsIn this randomized, controlled, open-label, parallel-group, multicenter, proof-of-concept trial, adults receiving vasopressors, CRRT since ≤ 24 h and cardiac output monitoring were randomized (ratio 1:1) to receive during 72 h a UFNET ≥ 100 ml·h−1, adjusted using a functional hemodynamic protocol (intervention), or a UFNET ≤ 25 ml·h−1 (control). The primary outcome was the cumulative FB at 72 h and was analyzed in patients alive at 72 h and in whom monitoring and CRRT were continuously provided (modified intention-to-treat population [mITT]). Secondary outcomes were analyzed in the intention-to-treat (ITT) population.ResultsBetween June 2021 and April 2023, 55 patients (age 69 [interquartile range, IQR: 62; 74], 35% female, Sequential Organ Failure Assessment (SOFA) 13 [11; 15]) were randomized (25 interventions, 30 controls). In the mITT population, (21 interventions, 24 controls), the 72 h FB was −2650 [−4574; −309] ml in the intervention arm, and 1841 [821; 5327] ml in controls (difference: 4942 [95% confidence interval: 2736–6902] ml, P < 0.01). Hemodynamics, oxygenation and the number of HIRRT at 72 h, and day-90 mortality did not statistically differ between arms.ConclusionIn patients with vasopressors, a UFNET fluid removal strategy secured by a hemodynamic protocol allowed active fluid balance control, compared to the standard of care.
Impact of left ventricular scar burden on acute response to conduction system pacing
Introduction: Conduction system pacing is a novel way for delivering cardiac resynchronisation therapy (CRT). This may deliver more effective ventricular resynchronisation than the gold standard, biventricular pacing (BVP). In BVP scar burden is known to impact response but whether this is true for conduction system pacing is unknown. Methods: Patients with standard CRT indications were recruited. They underwent a pre-procedure cardiac MRI, with late gadolinium enhancement to assess scar. Scar burden was quantified as the percentage of the amount of myocardium for each segment and the whole of the left ventricle (total scar). Conduction system pacing with both His bundle CRT (HB-CRT) and left bundle area CRT (LBA-CRT) was attempted in everyone, and the modality that delivered the narrowest QRS duration was selected. The electrical response was measured using non-invasive mapping (ECGi, CardioInsight, Medtronic). The haemodynamic response was measured with a high precision protocol. We investigated the impact of scar on the electrical and haemodynamic response. Results: A total of 26 patients were recruited, 85% male, mean age 69 ± 10 years, ischaemic cardiomyopathy in 35% and mean QRS duration 160 ± 15. LGE was observed in 96% of cases, mean total scar burden was 13 ± 12% (range 1–39%). We found a significant correlation between amount of scar and both the electrical and acute haemodynamic response (Figure 1). Patients with a lower scar burden obtained a greater improvement in both electrical resynchronisation (R=0.55, 95% CI 0.21–0.77, p<0.01, for reduction in left ventricular activation time [LVAT]), and acute haemodynamic response (R=0.5, 95% CI 0.18–0.76, p=0.005 for increase in acute systolic blood pressure). Conclusion: Conduction system pacing appears to be less effective in patients with a high left ventricular scar burden. We observed a strong correlation between scar burden and both ventricular electrical resynchronisation and acute haemodynamic response. This information may help patient selection for conduction system CRT. Alternative CRT modalities or combinations of modalities warrant further investigation in this challenging group of patients. ❑ [Image Omitted]
Invasive assessment of haemodynamic compromise and coronary blood flow during simulated VT
Introduction: Reducing unnecessary and inappropriate implantable cardioverter defibrillator (ICD) therapies reduces mortality. This was demonstrated in studies that investigated using higher rates for treatment zones and longer detection windows. ICDs currently do not utilise haemodynamic measurements to guide therapies. We have previously shown that a potentially implantable sensor can reliably identify loss of perfusion in ventricular fibrillation. It is possible that programming even longer detection windows could further reduce unnecessary shocks; however, it is not known in how many patients this may be beneficial, and the risk with adopting this approach is that appropriate shocks would be withheld for longer than necessary in the presence of reduced coronary blood flow (CBF). A disadvantage of using higher heart rate zones is that slower haemodynamically compromising VTs are left untreated. We investigated the impact of simulated VT on CBF and invasive blood pressure (BP). The aims were to determine whether detection windows could potentially be safely extended in some patients during VT and to identify what proportion of patients poorly tolerate episodes of slower VT. Methods: We recruited patients undergoing a clinically indicated invasive coronary angiogram. We simulated VT by delivering right ventricular VVI pacing, via a temporary wire. Each patient underwent a randomized ventricular pacing (Vp) protocol (140, 160, 180 and 200 bpm) for a minimum of 30 seconds. During each Vp protocol, continuous 3-lead ECG, invasive beat-by-beat arterial BP and invasive CBF, using a combowire in the mid-left anterior descending artery, were recorded. Significant haemodynamic compromise was defined as a reduction in CBF and/or a sustained drop of 30% in systolic BP (SBP) compared with measurements made during baseline rhythm. Results: A total of 21 patients were recruited, of whom 8 (38%) were female. The mean age was 65 years, and 5 patients (24%) had a left ventricular ejection fraction less than 35%. Data were collected during 145 simulated VT episodes (25 at 200 bpm, 42 at 180 bpm, 39 at 160 and 140 bpm, and 38 at 120 bpm). Results showed that 28% of simulated VT episodes at a rate of 200 bpm were haemodynamically tolerated. This suggests that ICD therapies could potentially be delayed for longer during these VT episodes to allow more time for VT to self-terminate. Haemodynamic compromise was observed in a proportion of slower simulated VT episodes (rates that are below current guidelines for primary prevention programming). For the combined endpoint of decline in CBF and SBP, VT was not tolerated in 11 (28.9%) at 120 bpm, 12 (30.8%) at 140 bpm, 22 (56.4%) at 160 bpm and 28 (66.7%) at 180 bpm. An isolated reduction in CBF had a greater impact on haemodynamic compromise at slower rates (9 (23.7%) at 120 bpm vs 1 (2.6%) at 160 bpm), whereas faster rates were driven by sustained drops in SBP. Proportionally, more patients had haemodynamic compromise at higher heart rates compared with slower heart rates (p=0.016). Conclusion: One-third of simulated VT episodes at 200 bpm were haemodynamically well tolerated. This suggests VT detection windows could potentially be safely extended, with the aim of reducing unnecessary therapies in a significant number of VT episodes. In contrast, many episodes of slower VT were poorly tolerated, implying that therapies may be beneficial. Thus, ICD programming could be further optimized with haemodynamically guided therapies compared with currently used methods, which exclusively rely on the electrogram. [Image Omitted]
Esmolol Kullanılarak Oluşturulan Hipotansif Anestezinin Distorsiyon Ürünü Otoakustik Emisyona Etkisi
Amaç: Bu çalışmanın amacı esmolol kullanılarak oluşturulan hipotansif anestezinin DPOAE (distorsiyon ürünü otoakustilk emisyon) yanıtlarına etkisini ve bu yolla koklear monitorizasyonda kullanılabilirliğini araştırmaktır. Gereç ve Yöntemler: Bu çalısma, genel anestezi altında opere edilen 18-65 yaş aralığında, 25 hastayı kapsamaktadır. 50-300 mcg/kg/dk esmolol infüzyonu anestezi indüksiyonuyla eşzamanlı uygulanarak, Bispectral Index (BIS) değeri 40-60 aralığında sürdürüldü. Ameliyat süresince, ortalama arter basıncı bazal değerin %20 altında olacak şekilde esmolol infüzyon dozları ayarlandı. Hemodinamik ve solunumsal parametreler ile otoakustik emisyon ölçümleri indüksiyon öncesi 0. dk, induksiyon sonrası 3. dk., 10. dk. ve 20. dk.’da kaydedildi. Bulgular: İzlem zamanları arasında 1500 Hz, 2000 Hz, 3000 Hz, 4000 Hz, 5000 hz, 6000 Hz’deki DPOAE düzeyleri yönünden istatistiksel olarak anlamlı farklılık görülmedi. Sıfırıncı dakikaya göre 3., 10., 20. dakikadaki DPOAE düzeylerindeki değişim ile hemodinamik ölçümlerde meydana gelen yüzdesel değişim miktarları arasında Bonferroni düzeltmesine göre istatistiksel olarak anlamlı korelasyon saptanmadı. Sonuç: Bu çalışmada esmolol kullanılarak oluşturulan hipotansif anestezinin DPOAE yanıtlarına etkisinin olmadığı saptanmıştır. Bu sonuç kullandığımız prosedürün lateral kafa tabanı cerrahilerinde hipotansif anestezi sağlayarak güvenli koklear monitorizasyona olanak vermesi açısından öneme sahiptir.
P004 Thoracic epidural test dose – unusual presentation and a narrow escape
Background and AimsA young female patient scheduled for bilateral lung metastatectomy underwent a T7–8 epidural catheterization in the left decubitus position. 10 minutes after injection of a test dose of 3 cc 1.5% plain lignocaine with 5 ug/cc adrenaline, she complained of heaviness in the right upper limb. She denied having any sensorimotor symptoms elsewhere and had minimal changes in the pulse rate and blood pressure. Examination revealed sensory deficit in right C7-T8 and left T3-T6 dermatomes and grade 3/5 power in the right hand and forearm muscles. The pattern and distribution of the sensorimotor deficits pointed to intrathecal injection with localization of action to the nondependent side. Isobaric intrathecal solutions are known to behave as hypobaric solutions in the CSF and therefore distribute in an antigravity manner. While total spinal block and severe haemodynamic compromise is well described, our patient had lateralization of effects and minimal haemodynamic changes, probably due to the lateral decubitus position given during the procedure. The patient had an uneventful surgery (under general anaesthesia) and postoperative recovery. The catheter was removed at the end of surgery.ConclusionsDiscussion The test dose described above has been questioned in literature as it has been extrapolated from the lumbar epidural test dose. It has been considered excessive in the thoracic segments due to its potential to cause severe harm negating its role as a ‘test dose’. It was fortunate that our patient had a largely unilateral spinal block rather than a high bilateral block. Also the patient’s alertness in reporting mild symptoms was crucial. In conclusion, the case emphasizes the need to meticulously check for effects of the test dose as well as for anaesthesiologistss to consider a smaller test dose for a thoracic epidural.
P121 An intriguing high risk case of modified radical mastectomy under combined thoracic paravertebral and serratus anterior plane block with total intra venous anaesthesia
Background and AimsWhile MRM is typically performed under GA, regional analgesia might lower the cardiovascular and respiratory complications in high-risk patients. In this case report, we present a 40-year-old female who had an anaphylactic shock and underwent 6 cycles of CPR following cefuroxime AST, EF of 45% and chronic bronchitis. Despite these challenges, she successfully underwent MRM for stage 3b breast carcinoma under combined thoracic paravertebral and serratus anterior plane block with total intra venous anaesthesia.MethodsAfter obtaining high risk consent and two large bore IV cannulas and standard monitors, USG guided right PVB at T2-T3, T3-T4 level was administered. She was induced with fentanyl and propofol and pro-seal LMA was placed. Muscle relaxant was not given. Propofol TIVA was started at 250 mg/hr. Post induction, USG guided right SAPB was given at 4th and 5th ribs.ResultsHemodynamic stability was achieved. Muscle relaxant necessity was not present. Opioid requirement was nil intra-operatively and postoperatively. She was pain-free in the post-operative period.Abstract P121 Figure 1Paravertebral block[Image Omitted. See PDF.]ConclusionsThus, combined thoracic PVB with SAPB along with TIVA is an alternative anesthetic modality for MRM surgeries. It avoided perioperative anaphylaxis, provided stable hemodynamic, post operative analgesia for a patient having multiple cardio-respiratory co-morbidities.
EP024 Comparison of efficacy of dexamethasone vs dexmedetomidine as adjuvants with ropivacine in scalp nerve block for patients undergoing awake craniotomy: a randomised controlled trial
Background and AimsAwake craniotomy is a specialized neurosurgical procedure that demands optimized anesthetic techniques to ensure patient comfort and facilitate intraoperative neurological monitoring. Scalp nerve block using local anesthetics combined with adjuvants has emerged as a key strategy. Literature regarding the dexamethasone vs dexmedetomidine as adjuvants in scalp block is less limited.The primary objective was to assess the time to the first rescue analgesic dose, with secondary objectives including onset of sensory block, hemodynamic stability, postoperative pain, and overall analgesic consumption.MethodsThis prospective, double-blinded, randomized controlled trial was conducted over 12 months in a tertiary care center. Fifty adult patients (aged 18– 65 years) undergoing elective awake craniotomy were randomized into two groups: Group RMED received a scalp nerve block with 0.5% Ropivacaine combined with Dexmedetomidine (1 µg/kg), and Group RMETH received 0.5% Ropivacaine combined with Dexamethasone (8 mg). Outcomes included the time to first rescue analgesia (primary outcome), onset of sensory block (pinprick test), intraoperative hemodynamic stability (HR and MAP), postoperative pain scores (NRS at intervals up to 24 hours), total 24-hour analgesic consumption, and the incidence of adverse events, including bradycardia, hypotension, and respiratory depression.ResultsBoth groups achieved effective sensory blockade with minimal complications. Group RMED demonstrated a significantly prolonged duration of analgesia compared to Group RMETH (median: 16 hours vs. 12 hours; p<0.05). The onset of sensory blockade was similar between groups (median: 6.5 minutes for RMED vs. 7 min for RMETH; p>0.05). Postoperative pain scores (NRS score) were significantly lower in Group RMED, and total 24-hour rescue analgesic consumption was significantly reduced in RMED (p<0.05).ConclusionsDexmedetomidine, as an adjuvant to 0.5% ropivacaine in scalp nerve blocks, provided a superior analgesic profile compared to dexamethasone in term of duration of pain relief, enhanced postoperative comfort, reduced analgesic requirement and ensured stable perioperative hemodynamics.
Detection of hypovolemia by non-invasive hemodynamic monitoring during major surgery using Ringer´s solution, 5% albumin, or 20% albumin as infusion fluid: a post-hoc analysis of a randomized clinical trial
Background Fluid loading with crystalloids is the conventional treatment of major hemorrhage but might tend to create fluid overload. We studied hemodynamic profiles of fluid replacement therapies during major surgical hemorrhage and compared the ability of pulse pressure variation (PPV), plethysmographic variation index (PVI), cardiac output (CO) and Guyton´s approach to detect hypovolemia. Methods In this single center randomized controlled trial, fluid replacement therapy to treat hemorrhage in 42 patients was randomized to consist of either 5% albumin (12 mL/kg) or 20% albumin (3 mL/kg) over 30 min, both completed by Ringer lactate replacing blood loss in a 1:1 ratio, or Ringer solution alone in a 3:1 ratio. Measurements included CO, PPV, PVI, arterial and central venous pressures, heart rate (HR) and subsequent calculation of Guyton´s physiological parameters. CO was measured by an esophageal Doppler probe. Results The Ringer-only fluid program resulted in slight hypovolemia (mean, 313 mL), decreased mean arterial pressure (MAP), increased HR, PPV values and vasopressor requirement. The 5% and 20% albumin programs were more effective in filling the vascular system, as evidenced by higher mean circulatory filling pressure and unchanged or decreased PPV over the 5 h observation period. The 20% albumin increased the systemic vascular resistance and the resistance to venous return. Receiver operating characteristics curves indicated that hypovolemia > 500 mL could only be accurately detected by PPV when 5% albumin was used, that PVI was reliable when Ringer was infused, and that CO indicated the hypovolemia when 20% albumin was administered. Conclusions The trends in PPV, PVI, and CO reflected the changes in intravascular volume, but how well they indicated hypovolemia > 500 mL may differ depending on the choice of infusion fluid. Identifying hypovolemia using non-invasive hemodynamic monitors remains challenging and associated with low predictive values. Trial registration number: NCT05391607, May 26, 2022.