Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
349 result(s) for "Imaging metrology"
Sort by:
A smart monocular vision metrology system based on computer for standing long jump
The standing long jump (SLJ) is widely used for large-scale fitness assessment, yet existing distance measurement solutions remain labor-intensive or hardware-dependent. We frame SLJ distance estimation as a markerless monocular imaging-metrology problem and present a reusable vision pipeline comprising key-frame selection, person detection, semantic segmentation of the heel and jump-mat, homography-based plane mapping, and distance computation with polynomial compensation for perspective-edge bias. Field tests with a high-frame-rate camera demonstrate real-time performance (≈ 23 FPS, ~ 42.7 ms per frame) and centimeter-level accuracy. Using manual tape measurement as the reference, the overall system attains an MAE of 0.71 cm; ablations show that removing key modules sharply degrades accuracy (e.g., 25.07 cm without incomplete-athlete handling; 4.35 cm without single-view perspective mapping; 2.31 cm without convex-hull/curvature-based heel extraction). Minimal calibration files and inference scripts are provided to support reproducibility and deployment in school testing.
Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: A feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm
The prediction of the risk of rupture of abdominal aortic aneurysm (AAA) is a complex problem. Currently the criteria to predict rupture of abdominal aortic aneurysms are aneurysm diameter and growth rates. It is generally believed that study of the wall strain distribution could be helpful to find a better decision criterion for surgery of aortic aneurysms before their rupture. The wall strain distribution depends on many biological and biomechanical factors such as elastic properties of the aorta, turbulent blood flow, anatomy of the aorta, presence of thrombus or not and so on. Recently, numerical simulations to estimate rupture-potential have received many attentions. However, none of the medical imaging tools for screening and monitoring of AAAs were studied in terms of mechanical behavior and experimentally to demonstrate their capability to measure relevant variables. The aim of this study was to develop a metrological approach for deployment testing of the ability of techniques for measuring local in-vitro deformations based on comparison of stereovision and MRI. In this paper, we present the implementation approach and results of the study based on cylindrical phantoms with or without AAA representing, respectively, healthy and unhealthy artery. Through this study, an experimental device was developed for the behavior study of AAA during a cardiac cycle. The results show that the stereovision techniques used in laboratory is well suited and is qualitatively and quantitatively equivalent with MRI measurements.
Digital Reflection Holography and Applications
This chapter contains sections titled: Introduction to Digital Holography and Methods Reflection Digital Holographic Microscope (DHM) Systems Development 3D Imaging, Static and Dynamic Measurements MEMS/Microsystems Characterization Applications References
Arbitrary thickness profile metrology of low‐Z and monolithic material components with a single X‐ray projection
Low‐Z and monolithic material components with arbitrary thickness profiles are extensively utilized in heat conduction, biocompatible implants, microfluidics and integrated optics, where precise thickness measurement is crucial for quality control and performance analysis. X‐ray micro‐computed tomography (micro‐CT) is widely employed for thickness metrology of such samples due to its nondestructive nature, high resolution and 3D imaging capabilities. However, the time‐consuming projection acquisition and image reconstruction processes hinder it from efficient or dynamic thickness measurements. Additionally, micro‐CT struggles with laminar samples. To overcome these limitations, we introduce X‐ray phase contrast imaging for the thickness metrology of low‐Z materials with arbitrary profiles by accurately retrieving the phase shift of X‐rays passing through the sample from a single projection. Calibration using a standard nylon fiber demonstrates that within a 1.33 mm field of view (FOV) the method achieves a mean absolute error of 0.68 µm for cylindrical fibers with diameters of 407.14 µm. We further demonstrate the method's capability for efficient measurement and damage assessment using a worn fiber with complex geometry. Additionally, we applied this method to the thickness measurement and error analysis of a microlens array with varying sub‐lens parameters. The 3D profiles of all sub‐lenses were obtained from a single projection, facilitating error analysis of height, symmetry and eccentricity. The results highlight the method's advantages, including being in situ, non‐contact and high precision, and having a large FOV, flexible adjustability and penetrative measurement capabilities. Our open device design suggests potential applications for dynamic thickness measurements and real‐time monitoring of samples within in situ loading devices. A thickness metrology method based on X‐ray phase contrast imaging is proposed. By precisely retrieving the phase shift of X‐rays passing through the sample, high‐precision arbitrary thickness profile measurement can be achieved with a single X‐ray projection. A measurement case of a microlens array is presented to demonstrate the effectiveness of this method.
Quantitative imaging biomarkers: A review of statistical methods for technical performance assessment
Technological developments and greater rigor in the quantitative measurement of biological features in medical images have given rise to an increased interest in using quantitative imaging biomarkers to measure changes in these features. Critical to the performance of a quantitative imaging biomarker in preclinical or clinical settings are three primary metrology areas of interest: measurement linearity and bias, repeatability, and the ability to consistently reproduce equivalent results when conditions change, as would be expected in any clinical trial. Unfortunately, performance studies to date differ greatly in designs, analysis method, and metrics used to assess a quantitative imaging biomarker for clinical use. It is therefore difficult or not possible to integrate results from different studies or to use reported results to design studies. The Radiological Society of North America and the Quantitative Imaging Biomarker Alliance with technical, radiological, and statistical experts developed a set of technical performance analysis methods, metrics, and study designs that provide terminology, metrics, and methods consistent with widely accepted metrological standards. This document provides a consistent framework for the conduct and evaluation of quantitative imaging biomarker performance studies so that results from multiple studies can be compared, contrasted, or combined.
Subdiffraction incoherent optical imaging via spatial-mode demultiplexing
I propose a spatial-mode demultiplexing (SPADE) measurement scheme for the far-field imaging of spatially incoherent optical sources. For any object too small to be resolved by direct imaging under the diffraction limit, I show that SPADE can estimate its second or higher moments much more precisely than direct imaging can fundamentally do in the presence of photon shot noise. I also prove that SPADE can approach the optimal precision allowed by quantum mechanics in estimating the location and scale parameters of a subdiffraction object. Realizable with far-field linear optics and photon counting, SPADE is expected to find applications in both fluorescence microscopy and astronomy.
Alkaline-Earth Atoms in Optical Tweezers
We demonstrate single-shot imaging and narrow-line cooling of individual alkaline-earth atoms in optical tweezers; specifically, strontium trapped in515.2−nmlight. Our approach enables high-fidelity detection of single atoms by imaging photons from the broad singlet transition while cooling on the narrow intercombination line, and we extend this technique to highly uniform two-dimensional tweezer arrays with 121 sites. Cooling during imaging is based on a previously unobserved narrow-line Sisyphus mechanism, which we predict to be applicable in a wide variety of experimental situations. Further, we demonstrate optically resolved sideband cooling of a single atom to near the motional ground state of a tweezer, which is tuned to a magic-trapping configuration achieved by elliptical polarization. Finally, we present calculations, in agreement with our experimental results, that predict a linear-polarization and polarization-independent magic crossing at 520(2) nm and 500.65(50) nm, respectively. Our results pave the way for a wide range of novel experimental avenues based on individually controlled alkaline-earth atoms in tweezers—from fundamental experiments in atomic physics to quantum computing, simulation, and metrology.
Submillihertz magnetic spectroscopy performed with a nanoscale quantum sensor
Precise timekeeping is critical to metrology, forming the basis by which standards of time, length, and fundamental constants are determined. Stable clocks are particularly valuable in spectroscopy because they define the ultimate frequency precision that can be reached. In quantum metrology, the qubit coherence time defines the clock stability, from which the spectral linewidth and frequency precision are determined. We demonstrate a quantum sensing protocol in which the spectral precision goes beyond the sensor coherence time and is limited by the stability of a classical clock. Using this technique, we observed a precision in frequency estimation scaling in time T as T −3/2 for classical oscillating fields. The narrow linewidth magnetometer based on single spins in diamond is used to sense nanoscale magnetic fields with an intrinsic frequency resolution of 607 microhertz, which is eight orders of magnitude narrower than the qubit coherence time.
Imaging viscous flow of the Dirac fluid in graphene
The electron–hole plasma in charge-neutral graphene is predicted to realize a quantum critical system in which electrical transport features a universal hydrodynamic description, even at room temperature 1 , 2 . This quantum critical ‘Dirac fluid’ is expected to have a shear viscosity close to a minimum bound 3 , 4 , with an interparticle scattering rate saturating 1 at the Planckian time, the shortest possible timescale for particles to relax. Although electrical transport measurements at finite carrier density are consistent with hydrodynamic electron flow in graphene 5 – 8 , a clear demonstration of viscous flow at the charge-neutrality point remains elusive. Here we directly image viscous Dirac fluid flow in graphene at room temperature by measuring the associated stray magnetic field. Nanoscale magnetic imaging is performed using quantum spin magnetometers realized with nitrogen vacancy centres in diamond. Scanning single-spin and wide-field magnetometry reveal a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point, establishing the viscous transport of the Dirac fluid. This measurement is in contrast to the conventional uniform flow profile imaged in a metallic conductor and also in a low-mobility graphene channel. Via combined imaging and transport measurements, we obtain viscosity and scattering rates, and observe that these quantities are comparable to the universal values expected at quantum criticality. This finding establishes a nearly ideal electron fluid in charge-neutral, high-mobility graphene at room temperature 4 . Our results will enable the study of hydrodynamic transport in quantum critical fluids relevant to strongly correlated electrons in high-temperature superconductors 9 . This work also highlights the capability of quantum spin magnetometers to probe correlated electronic phenomena at the nanoscale. Viscous Dirac fluid flow in room-temperature graphene is imaged using quantum diamond magnetometry, revealing a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point.
Methodology of Resonant Equiangular Composite Quantum Gates
The creation of composite quantum gates that implement quantum response functions U^(θ) dependent on some parameter of interest θ is often more of an art than a science. Through inspired design, a sequence of L primitive gates also depending on θ can engineer a highly nontrivial U^(θ) that enables myriad precision metrology, spectroscopy, and control techniques. However, discovering new, useful examples of U^(θ) requires great intuition to perceive the possibilities, and often brute force to find optimal implementations. We present a systematic and efficient methodology for composite gate design of arbitrary length, where phase-controlled primitive gates all rotating by θ act on a single spin. We fully characterize the realizable family of U^(θ) , provide an efficient algorithm that decomposes a choice of U^(θ) into its shortest sequence of gates, and show how to efficiently choose an achievable U^(θ) that, for fixed L , is an optimal approximation to objective functions on its quadratures. A strong connection is forged with classical discrete-time signal processing, allowing us to swiftly construct, as examples, compensated gates with optimal bandwidth that implement arbitrary single-spin rotations with subwavelength spatial selectivity.