Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
43,763
result(s) for
"Immunoassays"
Sort by:
Evaluation of Onboard Dilutions on the Beckman UniCel DxI 800 Immunoassay System
2015
Assays investigated were vitamin B12 (B12), erythropoietin (EPO), folate (FOL), bone specific alkaline phosphatase (Ostase), pregnancy associated plasma protein A (PAPP-A), and thyroid peroxidase antibody (TPO). Onboard dilutions may provide quality, labor, and turnaround time advantages by eliminating unnecessary manual processes. © American Society for Clinical Pathology Am J Clin Pathol 2015;144:
Journal Article
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
by
Calucho, Enric
,
Nguyen, Emily P.
,
Cinti, Stefano
in
631/1647/277
,
631/1647/350/59
,
631/1647/664
2020
Lateral-flow assays (LFAs) are quick, simple and cheap assays to analyze various samples at the point of care or in the field, making them one of the most widespread biosensors currently available. They have been successfully employed for the detection of a myriad of different targets (ranging from atoms up to whole cells) in all type of samples (including water, blood, foodstuff and environmental samples). Their operation relies on the capillary flow of the sample throughout a series of sequential pads, each with different functionalities aiming to generate a signal to indicate the absence/presence (and, in some cases, the concentration) of the analyte of interest. To have a user-friendly operation, their development requires the optimization of multiple, interconnected parameters that may overwhelm new developers. In this tutorial, we provide the readers with: (i) the basic knowledge to understand the principles governing an LFA and to take informed decisions during lateral flow strip design and fabrication, (ii) a roadmap for optimal LFA development independent of the specific application, (iii) a step-by-step example procedure for the assembly and operation of an LF strip for the detection of human IgG and (iv) an extensive troubleshooting section addressing the most frequent issues in designing, assembling and using LFAs. By changing only the receptors, the provided example procedure can easily be adapted for cost-efficient detection of a broad variety of targets.
This tutorial describes how to design nanoparticle-based LFAs for detecting biomolecules. The authors provide guidance on how to select the appropriate lateral-flow strip components and bioreceptors as well as detection strategies.
Journal Article
Performance characteristics of five immunoassays for SARS-CoV-2: a head-to-head benchmark comparison
by
Hatch, Stephanie B.
,
Dunachie, Susanna J
,
Coker, Jesse
in
Analysis
,
Antibodies
,
Antibodies, Viral - blood
2020
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a global pandemic in 2020. Testing is crucial for mitigating public health and economic effects. Serology is considered key to population-level surveillance and potentially individual-level risk assessment. However, immunoassay performance has not been compared on large, identical sample sets. We aimed to investigate the performance of four high-throughput commercial SARS-CoV-2 antibody immunoassays and a novel 384-well ELISA.
We did a head-to-head assessment of SARS-CoV-2 IgG assay (Abbott, Chicago, IL, USA), LIAISON SARS-CoV-2 S1/S2 IgG assay (DiaSorin, Saluggia, Italy), Elecsys Anti-SARS-CoV-2 assay (Roche, Basel, Switzerland), SARS-CoV-2 Total assay (Siemens, Munich, Germany), and a novel 384-well ELISA (the Oxford immunoassay). We derived sensitivity and specificity from 976 pre-pandemic blood samples (collected between Sept 4, 2014, and Oct 4, 2016) and 536 blood samples from patients with laboratory-confirmed SARS-CoV-2 infection, collected at least 20 days post symptom onset (collected between Feb 1, 2020, and May 31, 2020). Receiver operating characteristic (ROC) curves were used to assess assay thresholds.
At the manufacturers' thresholds, for the Abbott assay sensitivity was 92·7% (95% CI 90·2–94·8) and specificity was 99·9% (99·4–100%); for the DiaSorin assay sensitivity was 96·2% (94·2–97·7) and specificity was 98·9% (98·0–99·4); for the Oxford immunoassay sensitivity was 99·1% (97·8–99·7) and specificity was 99·0% (98·1–99·5); for the Roche assay sensitivity was 97·2% (95·4–98·4) and specificity was 99·8% (99·3–100); and for the Siemens assay sensitivity was 98·1% (96·6–99·1) and specificity was 99·9% (99·4–100%). All assays achieved a sensitivity of at least 98% with thresholds optimised to achieve a specificity of at least 98% on samples taken 30 days or more post symptom onset.
Four commercial, widely available assays and a scalable 384-well ELISA can be used for SARS-CoV-2 serological testing to achieve sensitivity and specificity of at least 98%. The Siemens assay and Oxford immunoassay achieved these metrics without further optimisation. This benchmark study in immunoassay assessment should enable refinements of testing strategies and the best use of serological testing resource to benefit individuals and population health.
Public Health England and UK National Institute for Health Research.
Journal Article
Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey
by
Posthuma-Trumpie, Geertruida A
,
Korf, Jakob
,
van Amerongen, Aart
in
Acronyms
,
analysis
,
Analytical Chemistry
2009
Lateral flow (immuno)assays are currently used for qualitative, semiquantitative and to some extent quantitative monitoring in resource-poor or non-laboratory environments. Applications include tests on pathogens, drugs, hormones and metabolites in biomedical, phytosanitary, veterinary, feed/food and environmental settings. We describe principles of current formats, applications, limitations and perspectives for quantitative monitoring. We illustrate the potentials and limitations of analysis with lateral flow (immuno)assays using a literature survey and a SWOT analysis (acronym for “strengths, weaknesses, opportunities, threats”). Articles referred to in this survey were searched for on MEDLINE, Scopus and in references of reviewed papers. Search terms included “immunochromatography”, “sol particle immunoassay”, “lateral flow immunoassay” and “dipstick assay”.
Journal Article
Fluorescent–Electrochemical–Colorimetric Triple-Model Immunoassays with Multifunctional Metal–Organic Frameworks for Signal Amplification
2025
Multimode immunoassays based on multiple response mechanisms have received great attention due to their capacity to effectively improve the accuracy and reliability of biosensing platforms. However, few strategies have been reported for triple-mode immunoassays due to the shortage of multifunctional sensing materials and the incompatibility of signal transduction methods in different detection modes. In this work, a fluorescent–electrochemical–colorimetric triple-mode immunoassay platform was proposed with Cu-based metal–organic frameworks (MOFs) as the signal labels. The captured Cu-MOFs were successfully decomposed under an acidic condition, leading to the release of numerous Cu2+ ions and 2-aminobenzene-1,4-dicarboxylic acid (NH2-BDC) ligands. The released NH2-BDC were determined by fluorescence titration. Meanwhile, the released Cu2+ were readily quantified by differential pulse voltammetry (DPV) and simply detected through the catalytic oxidation of chromogenic substrate 3,3′,5,5′-tetramethylbenzidine (TMB). Taking alpha-fetoprotein (AFP) as a model analyte, the designed triple-mode immunoassays showed good performances with the linear range of 10–200 pg/mL, 10–200 pg/mL, and 1–100 pg/mL for the fluorescent, electrochemical, and colorimetric modes, respectively. The proposed triple-mode biosensing platforms show great potential for the applications in disease diagnosis, since they can be easily extended to other bioassays by changing the targets and recognition elements.
Journal Article
An ultrasensitive electrochemical immunosensor for carcinoembryonic antigen detection based on two-dimensional PtPd/Cu-TCPP
2023
Establishing an effective signal amplification strategy is the key to achieving sensitive detection of analytes by electrochemical immunoassay. In this work, a novel sandwich-type electrochemical immunosensor with dual-signal amplification was successfully constructed using PtPd/Cu-TCPP(Fe) as the sensing platform and mesoporous silicon dioxide as the signal amplifier. Firstly, two-dimensional wrinkled Cu-TCPP(Fe) nanomaterials loaded with PtPd nanoparticles have strong affinity for the immobilization of capture antibodies and can generate excellent electrochemical signals. Meanwhile, the mesoporous silicon dioxide with large steric hindrance was used as signal label to further improve the sensitivity of the immunosensor by increasing the difference of the current response signal. Under optimal experimental conditions, the electrochemical immunosensor exhibited a wide linear detection range from 0.1 pg/mL to 1.0 [mu]g/mL, with a detection limit as low as 0.166 fg/mL. The experimental results showed that the constructed immunosensor has a great application prospect in clinical biomarker detection.
Journal Article
Islet Autoantibody Standardization Program 2018 Workshop: Interlaboratory Comparison of Glutamic Acid Decarboxylase Autoantibody Assay Performance
2019
The Islet Autoantibody Standardization Program (IASP) aims to improve the performance of immunoassays measuring type 1 diabetes (T1D)-associated autoantibodies and the concordance of results among laboratories. IASP organizes international interlaboratory assay comparison studies in which blinded serum samples are distributed to participating laboratories, followed by centralized collection and analysis of results, providing participants with an unbiased comparative assessment. In this report, we describe the results of glutamic acid decarboxylase autoantibody (GADA) assays presented in the IASP 2018 workshop.
In May 2018, IASP distributed to participants uniquely coded sera from 43 new-onset T1D patients, 7 multiple autoantibody-positive nondiabetic individuals, and 90 blood donors. Results were analyzed for the following metrics: sensitivity, specificity, accuracy, area under the ROC curve (ROC-AUC), partial ROC-AUC at 95% specificity (pAUC95), and concordance of qualitative and quantitative results.
Thirty-seven laboratories submitted results from a total of 48 different GADA assays adopting 9 different formats. The median ROC-AUC and pAUC95 of all assays were 0.87 [interquartile range (IQR), 0.83-0.89] and 0.036 (IQR, 0.032-0.039), respectively. Large differences in pAUC95 (range, 0.001-0.0411) were observed across assays. Of formats widely adopted, bridge ELISAs showed the best median pAUC95 (0.039; range, 0.036-0.041).
Several novel assay formats submitted to this study showed heterogeneous performance. In 2018, the majority of the best performing GADA immunoassays consisted of novel or established nonradioactive tests that proved on a par or superior to the radiobinding assay, the previous gold standard assay format for GADA measurement.
Journal Article
Lateral-flow immunoassays for mycotoxins and phycotoxins: a review
by
D’Arco, Gilda
,
Giraudi, Gianfranco
,
Giovannoli, Cristina
in
Analytical Chemistry
,
Biochemistry
,
Characterization and Evaluation of Materials
2013
Natural toxin (for example mycotoxin and phycotoxin) contamination of food is of safety and economic concern, so much effort is devoted to the development of screening methods which enable the toxins to be continuously and widely monitored in food and feed. More generally speaking, rapid and non-instrumental assays for detection of a variety of food contaminants are generating ever-increasing scientific and technological interest because they enable high-throughput, economical, on-site monitoring of such contaminants. Among rapid methods for first-level screening of food contaminants, lateral-flow immunoassay (LFIA), also named immunochromatographic assay or immune-gold colloid immunoassay, has recently attracted scientific and industrial interest because of its attractive property of enabling very rapid, one-step, in-situ analysis. This review focuses on new aspects of the development and optimization of lateral-flow devices for mycotoxin and phycotoxin detection, including strategies for management of matrix interference and, particularly, for investigation of the improvements achieved by signal-enhancing strategies or by application of non-gold nanoparticle signal reporters.
Figure 1
Competitive lateral flow immunoassay for myco- or phycotoxin: the
Test
zone is formed by adsorbing a conjugate of the target compound (
toxin
);
Control
zone is formed by anti-species antibodies (
white
), reporters are specific (anti-toxin antibodies,
black
) and non-specific (
grey
) antibodies labelled with gold nanoparticles (
GNP
). Focalization of GNP-labelled antibodies determines a visible/detectable colour appearance on both the Test and Control lines, which can be related to analyte amount in a liquid sample.
Journal Article
Accuracy and efficacy of pre-dengue vaccination screening for previous dengue infection with five commercially available immunoassays: a retrospective analysis of phase 3 efficacy trials
2021
The tetravalent dengue vaccine (CYD-TDV) has been shown to provide protection against dengue disease over 5-year follow-up in participants with previous dengue infection, but increased the risk of dengue hospitalisation and severe dengue during long-term follow-up in those without previous dengue infection. WHO recommended pre-vaccination screening to identify those with previous dengue infection (ie, dengue seropositive) who would benefit from vaccination. We re-evaluated CYD-TDV efficacy in those identified as dengue seropositive using five commercially available immunoassays, and assessed immunoassay performance.
We included participants in the immunogenicity subsets of the phase 3 CYD14 (NCT01373281) and CYD15 (NCT01374516) CYD-TDV efficacy trials, which enrolled children aged 2–16 years in 2011–12 in five countries in the Asia-Pacific region (CYD14) and five Latin American countries (CYD15). Participants assessed had received at least one injection of study drug (CYD-TDV or placebo) and had baseline samples available. We tested baseline samples by IgG-based immunoassays to classify baseline dengue serostatus, using two ELISAs (EUROIMMUN and Panbio) and three rapid diagnostic tests (RDTs; TELL ME FAST, SD BIOLINE, and OnSite). Vaccine efficacy in preventing symptomatic, hospitalised, and severe virologically confirmed dengue was determined for participants who tested positive by each immunoassay. The specificity and sensitivity of each immunoassay was determined as percentage negative and positive agreement compared with the reference algorithm, which used dengue plaque reduction neutralisation test with 50% and 90% cutoffs and non-structural protein 1 IgG ELISA results to assign baseline serostatus.
Samples were available for 3967 participants, 2735 (69·0%) of whom were classified as seropositive by the reference algorithm. Vaccine efficacy against symptomatic virologically confirmed dengue in immunoassay-positive participants was high across all five immunoassays (EUROIMMUN ELISA 88·2% [95% CI 77·3 to 93·9], Panbio ELISA 87·6% [76·7 to 93·4], TELL ME FAST RDT 88·8% [67·0 to 96·2], SD BIOLINE RDT 82·8% [66·9 to 91·1], and OnSite RDT 89·7% [64·6 to 97·0]), as was vaccine efficacy against hospitalised virologically confirmed dengue (EUROIMMUN-ELISA 72·8% [38·9 to 87·9], Panbio ELISA 77·5% [52·8 to 89·3], TELL ME FAST RDT 92·4% [37·8 to 99·1], SD BIOLINE RDT 87·2% [54·5 to 96·4], and OnSite RDT 73·7% [–5·1 to 93·4]) and severe virologically confirmed dengue (EUROIMMUN ELISA 86·9% [–16·8 to 98·5], Panbio ELISA 91·3% [27·6 to 99·0], TELL ME FAST RDT 100·0% [not estimable to 100·0%], SD BIOLINE RDT 89·4% [9·6 to 98·8], and OnSite RDT 73·4% [–193·7 to 97·6]). The immunoassays exhibited high specificity (≥98·8% for all immunoassays apart from SD BIOLINE RDT) but variable sensitivities, with higher sensitivities observed for the ELISAs (EUROIMMUN 89·2% [87·9 to 90·3] and Panbio 92·5 [91·4 to 93·5]) than the RDTs (TELL ME FAST 52·5% [50·6 to 54·4], SD BIOLINE 71·1% [69·3 to 72·8], and OnSite 47·6% [45·7 to 49·5]).
Our findings suggest that these immunoassays could be used for pre-vaccination screening for CYD-TDV as tools to assist risk stratification until more sensitive and convenient tests become available.
Sanofi Pasteur.
Journal Article