Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
11,025
result(s) for
"Impedance spectroscopy"
Sort by:
FPGA-Based Processor for Continual Capacitive-Coupling Impedance Spectroscopy and Circuit Parameter Estimation
by
Yuho Tanaka
,
Akihiko Tsukahara
,
Akinori Ueno
in
Accuracy
,
capacitive-coupling impedance spectroscopy
,
Chemical technology
2022
In principle, the recently proposed capacitive-coupling impedance spectroscopy (CIS) has the capability to acquire frequency spectra of complex electrical impedance sequentially on a millisecond timescale. Even when the measured object with time-varying unknown resistance Rx is capacitively coupled with the measurement electrodes with time-varying unknown capacitance Cx, CIS can be measured. As a proof of concept, this study aimed to develop a prototype that implemented the novel algorithm of CIS and circuit parameter estimation to verify whether the frequency spectra and circuit parameters could be obtained in milliseconds and whether time-varying impedance could be measured. This study proposes a dedicated processor that was implemented as field-programmable gate arrays to perform CIS, estimate Rx and Cx, and their digital-to-analog conversions at a certain time, and to repeat them continually. The proposed processor executed the entire sequence in the order of milliseconds. Combined with a front-end nonsinusoidal oscillator and interfacing circuits, the processor estimated the fixed Rx and fixed Cx with reasonable accuracy. Additionally, the combined system with the processor succeeded in detecting a quick optical response in the resistance of the cadmium sulfide (CdS) photocell connected in series with a capacitor, and in reading out their resistance and capacitance independently as voltages in real-time.
Journal Article
Electrochemical Impedance Spectroscopy: A New Chapter in the Fast and Accurate Estimation of the State of Health for Lithium-Ion Batteries
by
Liu, Yanshuo
,
Li, Liwei
,
Wang, Kai
in
data-driven method
,
Electric vehicles
,
electrochemical impedance spectroscopy
2023
Lithium-ion batteries stand out from other clean energy sources because of their high energy density and small size. With the increasing application scope and scale of lithium-ion batteries, real-time and accurate monitoring of its state of health plays an important role in ensuring the healthy and stable operation of an energy storage system. Due to the interaction of various aging reactions in the aging process of lithium-ion batteries, the capacity attenuation shows no regularity. However, the traditional monitoring method is mainly based on voltage and current, which cannot reflect the internal mechanism, so the accuracy is greatly reduced. Recently, with the development of electrochemical impedance spectroscopy, it has been possible to estimate the state of health quickly and accurately online. Electrochemical impedance spectroscopy can measure battery impedance in a wide frequency range, so it can reflect the internal aging state of lithium-ion batteries. In this paper, the latest impedance spectroscopy measurement technology and electrochemical impedance spectroscopy based on lithium-ion battery health state estimation technology are summarized, along with the advantages and disadvantages of the summary and prospects. This fills the gap in this aspect and is conducive to the further development of this technology.
Journal Article
Impedance spectroscopy : theory, experiment, and applications
by
Barsoukov, Evgenij
,
Macdonald, J. Ross (James Ross)
in
Electrochemical analysis
,
Electrochemical analysis -- Experiments
,
Experiments
2005
A skillful balance of theoretical considerations and practical know-how Backed by a team of expert contributors, the Second Edition of this highly acclaimed publication brings a solid understanding of impedance spectroscopy to students, researchers, and engineers in physical chemistry, electrochemistry, and physics. Starting with general principles, the book moves on to explain in detail practical applications for the characterization of materials in electrochemistry, semiconductors, solid electrolytes, corrosion, solid-state devices, and electrochemical power sources. The book covers all of the topics needed to help readers identify whether impedance spectroscopy may be an appropriate method for their particular research problem. The book helps readers quickly grasp how to apply their new knowledge of impedance spectroscopy methods to their own research problems through the use of unique features such as: * Step-by-step instructions for setting up experiments and then analyzing the results * Theoretical considerations for dealing with modeling, equivalent circuits, and equations in the complex domain * Best measurement methods for particular systems and alerts to potential sources of errors * Equations for the most widely used impedance models * Figures depicting impedance spectra of typical materials and devices * Extensive references to the scientific literature for more information on particular topics and current research This Second Edition incorporates the results of the last two decades of research on the theories and applications of impedance spectroscopy. Most notably, it includes new chapters on batteries, supercapacitors, fuel cells, and photochromic materials. A new chapter on commercially available measurement systems reflects the emergence of impedance spectroscopy as a mainstream research tool. With its balanced focus on both
theory and practical problem solving, Impedance Spectroscopy: Theory, Experiment, and Applications, Second Edition serves as an excellent graduate-level textbook as well as a hands-on guide and reference for researchers and engineers.
Impedance-based cellular assays for regenerative medicine
2018
Therapies based on regenerative techniques have the potential to radically improve healthcare in the coming years. As a result, there is an emerging need for non-destructive and label-free technologies to assess the quality of engineered tissues and cell-based products prior to their use in the clinic. In parallel, the emerging regenerative medicine industry that aims to produce stem cells and their progeny on a large scale will benefit from moving away from existing destructive biochemical assays towards data-driven automation and control at the industrial scale. Impedance-based cellular assays (IBCA) have emerged as an alternative approach to study stem-cell properties and cumulative studies, reviewed here, have shown their potential to monitor stem-cell renewal, differentiation and maturation. They offer a novel method to non-destructively assess and quality-control stem-cell cultures. In addition, when combined with in vitro disease models they provide complementary insights as label-free phenotypic assays. IBCA provide quantitative and very sensitive results that can easily be automated and up-scaled in multi-well format. When facing the emerging challenge of real-time monitoring of three-dimensional cell culture dielectric spectroscopy and electrical impedance tomography represent viable alternatives to two-dimensional impedance sensing.
This article is part of the theme issue ‘Designer human tissue: coming to a lab near you’.
Journal Article
Comparing nanobody and aptamer-based capacitive sensing for detection of interleukin-6 (IL-6) at physiologically relevant levels
by
Sánchez-Salcedo, Raquel
,
Lobo-Castañón, María Jesús
,
Miranda-Castro, Rebeca
in
1-Hexanol
,
Analytical Chemistry
,
Aptamers
2023
A major societal challenge is the development of the necessary tools for early diagnosis of diseases such as cancer and sepsis. Consequently, there is a concerted push to develop low-cost and non-invasive methods of analysis with high sensitivity and selectivity. A notable trend is the development of highly sensitive methods that are not only amenable for point-of-care (
POC
) testing, but also for wearable devices allowing continuous monitoring of biomarkers. In this context, a non-invasive test for the detection of a promising biomarker, the protein Interleukin-6 (IL-6), could represent a significant advance in the clinical management of cancer, in monitoring the chemotherapy response, or for prompt diagnosis of sepsis. This work reports a capacitive electrochemical impedance spectroscopy sensing platform tailored towards
POC
detection and treatment monitoring in human serum. The specific recognition of IL-6 was achieved employing gold surfaces modified with an anti-IL6 nanobody (anti-IL-6 VHH) or a specific IL-6 aptamer. In the first system, the anti-IL-6 VHH was covalently attached to the gold surface using a binary self-assembled-monolayer (SAM) of 6-mercapto-1-hexanol (MCH) and 11-mercaptoundecanoic acid. In the second system, the aptamer was chemisorbed onto the surface in a mixed SAM layer with MCH. The analytical performance for each label-free sensor was evaluated in buffer and 10% human serum samples and then compared. The results of this work were generated using a low-cost, thin film eight-channel gold sensor array produced on a flexible substrate providing useful information on the future design of
POC
and wearable impedance biomarker detection platforms.
Journal Article
Electrical impedance spectroscopy (EIS) in plant roots research: a review
by
Ren, ZhenHui
,
Liu, Yang
,
Li, DongMing
in
Agricultural production
,
Analysis
,
Artificial intelligence
2021
Nondestructive testing of plant roots is a hot topic in recent years. The traditional measurement process is time-consuming and laborious, and it is impossible to analyze the state of plant roots without destroying the sample. Recent studies have shown that as an excellent nondestructive measurement method, although electrical impedance spectroscopy (EIS) has made great achievements in many botanical research fields such as plant morphology and stress resistance, there are still limitations. This review summarizes the application of EIS in plant root measurement. The experiment scheme, instrument and electrode, excitation frequency range, root electrical characteristics, equivalent circuit, and combination of EIS and artificial intelligence (AI) are discussed. Furthermore, the review suggests that future research should focus on miniaturization of measurement equipment, standardization of planting environment and intelligentization of root diagnosis, so as to better apply EIS technology to in situ root nondestructive measurement.
Journal Article
Electrochemical Impedance Spectroscopy Analysis of Hole Transporting Material Free Mesoporous and Planar Perovskite Solar Cells
by
Abdulrahim, Sumayya M.
,
Bahadra, Jolly
,
Al-Thani, Noora J.
in
Carbon
,
Efficiency
,
electrical equivalent circuit
2020
The future photovoltaic technologies based on perovskite materials are aimed to build low tech, truly economical, easily fabricated, broadly deployable, and trustworthy solar cells. Hole transport material (HTM) free perovskite solar cells (PSCs) are among the most likely architectures which hold a distinctive design and provide a simple way to produce large-area and cost-effective manufacture of PSCs. Notably, in the monolithic scheme of the HTM-free PSCs, all layers can be printed using highly reproducible and morphology-controlled methods, and this design has successfully been demonstrated for industrial-scale fabrication. In this review article, we comprehensively describe the recent advancements in the different types of mesoporous (nanostructured) and planar HTM-free PSCs. In addition, the effect of various nanostructures and mesoporous layers on their performance is discussed using the electrochemical impedance spectroscopy (EIS) technique. We bring together the different perspectives that researchers have developed to interpret and analyze the EIS data of the HTM-free PSCs. Their analysis using the EIS tool, the limitations of these studies, and the future work directions to overcome these limitations to enhance the performance of HTM-free PSCs are comprehensively considered.
Journal Article
An aptamer-based biosensor for detection of doxorubicin by electrochemical impedance spectroscopy
2018
An aptamer-based biosensor was developed for the detection of doxorubicin using electrochemical impedance spectroscopy. Doxorubicin and its 14-dehydroxylated version daunorubicin are anthracyclines often used in cancer treatment. Due to their mutagenic and cardiotoxic effects, detection in groundwater is desirable. We developed a biosensor using the daunorubicin-binding aptamer as biological recognition element. The aptamer was successfully co-immobilized with mercaptohexanol on gold and a density of 1.3*1013 ± 2.4*1012 aptamer molecules per cm2 was achieved. The binding of doxorubicin to the immobilized aptamer was detected by electrochemical impedance spectroscopy. The principle is based on the inhibition of electron transfer between electrode and ferro-/ferricyanide in solution caused by the binding of doxorubicin to the immobilized aptamer. A linear relationship between the charge transfer resistance (Rct) and the doxorubicin concentration was obtained over the range of 31 nM to 125 nM doxorubicin, with an apparent binding constant of 64 nM and a detection limit of 28 nM. With the advantages of high sensitivity, selectivity, and simple sensor construction, this method shows a high potential of impedimetric aptasensors in environmental monitoring.Graphical abstractMeasurement chamber and immobilization principle for the detection of doxorubicin by electrochemical impedance spectroscopy.
Journal Article
Nickel Oxide-Incorporated Polyaniline Nanocomposites as an Efficient Electrode Material for Supercapacitor Application
by
Acharya, Debendra
,
Chhetri, Kisan
,
Yadav, Amar Prasad
in
Alternative energy sources
,
Analysis
,
Aniline
2022
This work reports the facile, controlled, and low-cost synthesis of a nickel oxide and polyaniline (PANI) nanocomposites-based electrode material for supercapacitor application. PANI-NiO nanocomposites with varying concentrations of NiO were synthesized via in-situ chemical oxidative polymerization of aniline. The XRD and FTIR support the interaction of PANI with NiO and the successful formation of the PANI-NiO-x nanocomposite. The SEM analysis showed that the NiO and PANI were mixed homogenously, in which the NiO nanomaterial was incorporated in porous PANI globular nanostructures. The multiple phases of the nanocomposite electrode material enhance the overall performance of the energy-storage behavior of the supercapacitor that was tested in 1 M H2SO4 using cyclic voltammetry (CV), galvanostatic charge-discharge (GCD), and electrochemical impedance spectroscopy (EIS). Among the different nanocomposites, PANI-NiO-3 exhibit the specific capacitance of a 623 F g−1 at 1 A g−1 current density. Furthermore, the PANI-NiO-3 electrode retained 89.4% of its initial capacitance after 5000 cycles of GCD at a 20 A g−1 current density, indicating its significant cyclic stability. Such results suggest that PANI-NiO nanocomposite could be proposed as an appropriate electrode material for supercapacitor applications.
Journal Article
Experimental investigation of freeze injury temperatures in trees and their contributing factors based on electrical impedance spectroscopy
2024
In trees, injuries resulting from subfreezing temperatures can cause damage to the cellular biofilm system, metabolic functions, and fibrous reticulum, and even cell death. Investigating the occurrence of freezing damage and its contributing factors could help understand the mechanisms underlying freezing injury and prevent the subsequent damage in trees. To achieve this, a laboratory experiment was conducted using cut wood samples from Korean pine ( Pinus koraiensis Siebold & Zucc) and Simon poplar ( Populus simonii Carr.), and the effects of environmental freezing factors, including freezing temperatures, freezing duration, and cooling rate, on the temperature at which freezing injuries occur were examined using the electrical impedance spectroscopy (EIS) method. The semi-lethal temperature (LT50), as an indicator of freezing injury in wood tissue, was theoretically deduced based on the measured extracellular resistance ( r e ) using EIS. The contributory factors to changes in LT50 were determined and their relationship was established. The results revealed that all freezing factors exhibited significant effects on electrical impedance characteristics ( r e , r i , and τ), significantly influencing the LT50 of the wood. Random forest (RF) and support vector machine (SVM) models were used to assess the contribution of the freezing factors and moisture content (MC). Among the factors examined, freezing duration had the greatest impact on LT50, followed by the MC, whereas the contribution of the cooling rate was minimal. The model accuracies were 0.89 and 0.86 for Korean pine and Simon poplar, respectively. The findings of our study illustrate that the occurrence of freezing injury in trees is primarily influenced by the duration of freezing at specific subzero temperatures. Slow cooling combined with prolonged freezing at low subzero temperatures leads to earlier and more severe freezing damage.
Journal Article