Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
1,613
result(s) for
"Inertial measurement units"
Sort by:
A Review on the Inertial Measurement Unit Array of Microelectromechanical Systems
2024
In recent years, microelectromechanical systems (MEMS) technology has developed rapidly, and low precision inertial devices have achieved small volume, light weight, and mass production. Under this background, array technology has emerged to achieve high precision inertial measurement under the premise of low cost. This paper reviews the development of MEMS inertial measurement unit (IMU) array technology. First, the different types of common inertial measurement unit arrays are introduced and the basic principles are explained. Secondly, IMU array’s development status is summarized by analyzing the research results over the years. Then, the key technologies and corresponding development status of IMU array are described, respectively, including error analysis modeling and calibration, data fusion technology, fault detection, and isolation technology. Finally, the characteristics and shortcomings of the past research results are summarized, the future research direction is discussed, and some thoughts are put forward to further improve the accuracy of the IMU array.
Journal Article
Comparison of Wearable and Depth-Sensing Technologies with Electronic Walkway for Comprehensive Gait Analysis
2025
Accurate and scalable gait assessment is essential for clinical and research applications, including fall risk evaluation, rehabilitation monitoring, and early detection of neurodegenerative diseases. While electronic walkways remain the clinical gold standard, their high cost and limited portability restrict widespread use. Wearable inertial measurement units (IMUs) and markerless depth cameras have emerged as promising alternatives; however, prior studies have typically assessed these systems under tightly controlled conditions, with single participants in view, limited marker sets, and without direct cross-technology comparisons. This study addresses these gaps by simultaneously evaluating three sensing technologies—APDM wearable IMUs (tested in two separate configurations: foot-mounted and lumbar-mounted) and the Azure Kinect depth camera—against ProtoKinetics Zeno™ Walkway Gait Analysis System in a realistic clinical environment where multiple individuals were present in the camera’s field of view. Gait data from 20 older adults (mean age 70.06±9.45 years) performing Single-Task and Dual-Task walking trials were synchronously captured using custom hardware for precise temporal alignment. Eleven gait markers spanning macro, micro-temporal, micro-spatial, and spatiotemporal domains were compared using mean absolute error (MAE), Pearson correlation (r), and Bland–Altman analysis. Foot-mounted IMUs demonstrated the highest accuracy (MAE =0.00–6.12, r=0.92–1.00), followed closely by the Azure Kinect (MAE =0.01–6.07, r=0.68–0.98). Lumbar-mounted IMUs showed consistently lower agreement with the reference system. These findings provide the first comprehensive comparison of wearable and depth-sensing technologies with a clinical gold standard under real-world conditions and across an extensive set of gait markers. The results establish a foundation for deploying scalable, low-cost gait assessment systems in diverse healthcare contexts, supporting early detection, mobility monitoring, and rehabilitation outcomes across multiple patient populations.
Journal Article
Evaluating Behavior Recognition Pipeline of Laying Hens Using Wearable Inertial Sensors
by
Takuno, Ryo
,
Fujinami, Kaori
,
Sato, Itsufumi
in
animal activity recognition
,
Animal Husbandry - methods
,
Animal Welfare
2023
Recently, animal welfare has gained worldwide attention. The concept of animal welfare encompasses the physical and mental well-being of animals. Rearing layers in battery cages (conventional cages) may violate their instinctive behaviors and health, resulting in increased animal welfare concerns. Therefore, welfare-oriented rearing systems have been explored to improve their welfare while maintaining productivity. In this study, we explore a behavior recognition system using a wearable inertial sensor to improve the rearing system based on continuous monitoring and quantifying behaviors. Supervised machine learning recognizes a variety of 12 hen behaviors where various parameters in the processing pipeline are considered, including the classifier, sampling frequency, window length, data imbalance handling, and sensor modality. A reference configuration utilizes a multi-layer perceptron as a classifier; feature vectors are calculated from the accelerometer and angular velocity sensor in a 1.28 s window sampled at 100 Hz; the training data are unbalanced. In addition, the accompanying results would allow for a more intensive design of similar systems, estimation of the impact of specific constraints on parameters, and recognition of specific behaviors.
Journal Article
A Multimodal Fatigue Detection System Using sEMG and IMU Signals with a Hybrid CNN-LSTM-Attention Model
2025
Physical fatigue significantly impacts safety and performance across industrial, athletic, and medical domains, yet its detection remains challenging due to individual variability and limited generalizability of existing methods. This study introduces a multimodal fatigue detection system integrating surface electromyography (sEMG) and inertial measurement unit (IMU) signals, processed through a hybrid convolutional neural network–long short-term memory–attention (CNN-LSTM-Attention) model. Fatigue was induced in 35 healthy participants via step-up-and-down exercises, with gait data collected during natural walking before and after fatigue. The model leverages sEMG from the gastrocnemius lateralis and IMU-derived jerk signals from the tibialis anterior and rectus femoris to classify fatigue states. Evaluated using leave-one-subject-out cross-validation (LOSOCV), the system achieved an accuracy of 87.94% with bilateral EMG signals and a balanced recall of 87.94% for fatigued states using a combined IMU-EMG approach. These results highlight the system’s robustness for personalized fatigue monitoring, surpassing traditional subject-dependent methods by addressing inter-individual differences.
Journal Article
Kinesiological Analysis Using Inertial Sensor Systems: Methodological Framework and Clinical Applications in Pathological Gait
2025
Accurate gait assessment is essential for managing pathological locomotion, especially in elderly patients recovering from hip joint surgeries. Inertial measurement units (IMUs) provide real-time, objective data in clinical settings. This study examined pelvic oscillations in sagittal, frontal, and transverse planes using a wearable IMU system in two groups: Group A (n = 15, osteosynthesis metallica) and Group B (n = 34, arthroplasty), all over age 65. Gait analysis was conducted during assisted and unassisted walking. In the frontal plane, both groups showed statistically significant improvements: Group A from 46.4% to 75.2% (p = 0.001) and Group B from 52.6% to 72.2% (p = 0.001), reflecting enhanced lateral stability. In the transverse plane, Group A improved significantly from 47.7% to 80.2% (p = 0.001), while Group B showed a non-significant increase from 73.0% to 80.5% (p = 0.068). Sagittal plane changes were not statistically significant (Group A: 68.8% to 71.1%, p = 0.313; Group B: 76.4% to 69.1%, p = 0.065). These improvements correspond to better pelvic symmetry and postural control, which are critical for a safe and stable gait. Improvements were more pronounced during unassisted walking, indicating better pelvic control. These results confirm the clinical utility of IMUs in capturing subtle gait asymmetries and monitoring recovery progress. The findings support their use in tailoring rehabilitation strategies, particularly for enhancing frontal and transverse pelvic stability in elderly orthopedic patients.
Journal Article
Navigation Error Characteristics of LIO-, VIO-, and RIMU-Assisted INS/GNSS Multi-Sensor Fusion Schemes in a GNSS-Denied Environment
2026
Autonomous vehicles at level 3 and above must maintain high navigation accuracy, particularly in global navigation satellite system (GNSS)-denied environments. The main innovations of this work are threefold. First, we integrate visual inertial odometry (VIO) and light detection and ranging (LiDAR) inertial odometry (LIO) as external updates to mitigate the rapid drift of micro-electromechanical system (MEMS)-based industrial-grade inertial measurement units (IMUs) during long-term GNSS outages. Second, we adopt a redundant IMU (RIMU) approach that fuses multiple low-cost IMUs to reduce sensor noise and improve reliability. Third, we propose a system calibration methodology using both static and dynamic vehicle motion to estimate extrinsic parameters (boresight angles and lever arms) of the sensors, achieving an overall boresight angle root-mean-square error of 0.04 degrees in the simulation. Experiments were conducted under a 7 min GNSS-denied scenario in an underground parking lot, allowing for comparison of the error characteristics of multi-sensor fusion schemes against a navigation-grade reference. The INS/GNSS/LIO framework achieved a two-dimensional root-mean-square position error of 1.22 m (95% position error within 2.5 m), meeting the lane-level (1.5 m) accuracy requirement under a GNSS outage exceeding 7 min without prior maps. In contrast, the RINS/GNSS/VIO framework yielded a 4.71 m 2D mean position error under the same conditions. This paper provides a quantitative comparison of the baseline error characteristics of VIO-, LIO-, and RIMU-assisted INS/GNSS fusion under a GNSS-denied navigation scenario.
Journal Article
Quantifying Hand Motion Complexity in Simulated Sailing Using Inertial Sensors
by
Sarai, Gurdeep
,
Tirosh, Oren
,
Jayaraman, Prem Prakash
in
Acceleration
,
Accelerometry - instrumentation
,
Accelerometry - methods
2024
The control of hand movement during sailing is important for performance. To quantify the amount of regularity and the unpredictability of hand fluctuations during the task, the mathematical algorithm Approximate Entropy (ApEn) of the hand acceleration can be used. Approximate Entropy is a mathematical algorithm that depends on the combination of two input parameters including (1) the length of the sequences to be compared (m), and (2) the tolerance threshold for accepting similar patterns between two segments (r). The aim of this study is to identify the proper combinations of ‘m’ and ‘r’ parameter values for ApEn measurement in the hand movement acceleration data during sailing. Inertial Measurement Units (IMUs) recorded acceleration data for both the mainsail (non-dominant) and tiller (dominant) hands across the X-, Y-, and Z-axes, as well as vector magnitude. ApEn values were computed for 24 parameter combinations, with ‘m’ ranging from 2 to 5 and ‘r’ from 0.10 to 0.50. The analysis revealed significant differences in acceleration ApEn regularity between the two hands, particularly along the Z-axis, where the mainsail hand exhibited higher entropy values (p = 0.000673), indicating greater acceleration complexity and unpredictability. In contrast, the tiller hand displayed more stable and predictable acceleration patterns, with lower ApEn values. ANOVA results confirmed that parameter ‘m’ had a significant effect on acceleration complexity for both hands, highlighting differing motor control demands between the mainsail and tiller hands. These findings demonstrate the utility of IMU sensors and ApEn in detecting nuanced variations in acceleration dynamics during sailing tasks. This research contributes to the understanding of hand-specific acceleration patterns in sailing and provides a foundation for further studies on adaptive sailing techniques and motor control strategies for both novice and expert sailors.
Journal Article
Validation of Inertial Sensors to Evaluate Gait Stability
2023
The portability of wearable inertial sensors makes them particularly suitable for measuring gait in real-world walking situations. However, it is unclear how well inertial sensors can measure and evaluate gait stability compared to traditional laboratory-based optical motion capture. This study investigated whether an inertial sensor-based motion-capture suit could accurately assess gait stability. Healthy adult participants were asked to walk normally, with eyes closed, with approximately twice their normal step width, and in tandem. Their motion was simultaneously measured by inertial measurement units (IMU) and optical motion capture (Optical). Gait stability was assessed by calculating the margin of stability (MoS), short-term Lyapunov exponents, and step variability, along with basic gait parameters, using each system. We found that IMUs were able to detect the same differences among conditions as Optical for all but one of the measures. Bland–Altman and intraclass correlation (ICC) analysis demonstrated that mediolateral parameters (step width and mediolateral MoS) were measured less accurately by IMUs compared to their anterior-posterior equivalents (step length and anterior-posterior MoS). Our results demonstrate that IMUs can be used to evaluate gait stability through detecting changes in stability-related measures, but that the magnitudes of these measures might not be accurate or reliable, especially in the mediolateral direction.
Journal Article
Influence of Sampling Rate on Wearable IMU Orientation Estimation Accuracy for Human Movement Analysis
2025
Wearable inertial measurement units (IMUs) have been widely used in human movement analysis outside the laboratory. However, the IMU-based orientation estimation remains challenging, particularly in scenarios involving relatively fast movements. Increased sampling rate has the potential to improve accuracy, but it also increases power consumption and computational complexity. The relationship between sampling frequencies and accuracies remains unclear. We thus investigated the specific influence of IMU sampling frequency on orientation estimation across a spectrum of movement speeds and recommended sufficient sampling rates. Seventeen healthy subjects wore IMUs on their thigh, shank, and foot and performed walking (1.2 m/s) and running (2.2 m/s) trials on a treadmill, and a motion testbed with an IMU was used to mimic high-frequency cyclic human movements up to 3.0 Hz. Four widely used IMU sensor fusion algorithms computed orientations at 10, 25, 50, 100, 200, 400, 800, and 1600 Hz and were compared with marker-based optical motion capture (OMC) orientations to determine accuracy. Results suggest that the sufficient IMU sampling rate for walking is 100 Hz, running is 200 Hz, and high-speed cyclic movements is 400 Hz. The accelerometer sampling rate is less important than the gyroscope sampling rate. Further, accelerometer sampling rates exceeding 100 Hz even resulted in decreased accuracy because excessive orientation updates using distorted accelerations and angular velocity introduced more error than merely using angular velocity. These findings could serve as a foundation to inform wearable IMU development or selection across a spectrum of human gait movement speeds.
Journal Article
Time-Frequency Analysis of Motor Imagery During Plantar and Dorsal Flexion Movements Using a Low-Cost Ankle Exoskeleton
2025
Sensor technology plays a fundamental role in neuro-motor rehabilitation by enabling precise movement analysis and control. This study explores the integration of brain–machine interfaces (BMIs) and wearable sensors to enhance motor recovery in individuals with neuro-motor impairments. Specifically, different time-frequency transforms are evaluated to analyze the correlation between electroencephalographic (EEG) activity and ankle position, measured by using inertial measurement units (IMUs). A low-cost ankle exoskeleton was designed to conduct the experimental trials. Six subjects performed plantar and dorsal flexion movements while the EEG and IMU signals were recorded. The correlation between brain activity and foot kinematics was analyzed using the Short-Time Fourier Transform (STFT), Stockwell (ST), Hilbert–Huang (HHT), and Chirplet (CT) methods. The 8–20 Hz frequency band exhibited the highest correlation values. For motor imagery classification, the STFT achieved the highest accuracy (92.9%) using an EEGNet-based classifier and a state-machine approach. This study presents a dual approach: the analysis of EEG-movement correlation in different cognitive states, and the systematic comparison of four time-frequency transforms for both correlation and classification performance. The results support the potential of combining EEG and IMU data for BMI applications and highlight the importance of cognitive state in motion analysis for accessible neurorehabilitation technologies.
Journal Article