Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
479
result(s) for
"Joint Prosthesis - standards"
Sort by:
Diagnosis and Management of Prosthetic Joint Infection: Clinical Practice Guidelines by the Infectious Diseases Society of America
by
Rao, Nalini
,
Osmon, Douglas R.
,
Steckelberg, James M.
in
Allergies
,
Amputation
,
Anti-Bacterial Agents - therapeutic use
2013
These guidelines are intended for use by infectious disease specialists, orthopedists, and other healthcare professionals who care for patients with prosthetic joint infection (PJI). They include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation, 1-stage reimplantation, and amputation.
Journal Article
Executive Summary: Diagnosis and Management of Prosthetic Joint Infection: Clinical Practice Guidelines by the Infectious Diseases Society of America a
by
Rao, Nalini
,
Osmon, Douglas R.
,
Steckelberg, James M.
in
Anti-Bacterial Agents
,
Debridement
,
Humans
2013
These guidelines are intended for use by infectious disease specialists, orthopedists, and other healthcare professionals who care for patients with prosthetic joint infection (PJI). They include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation, 1-stage reimplantation, and amputation.
Journal Article
Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid
by
Kim, Hyojune
,
Alabdullatif, Fahad
,
Jeon, In-Ho
in
Arthritis
,
Arthroplasty
,
Arthroplasty, Replacement, Shoulder - adverse effects
2020
Background
Several modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate. This review aimed to compare rates of complications and revision surgeries between cemented polyethylene glenoid (PEG) and three examples of modern MBG designs.
Methods
Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into three groups based on follow-up duration: < 36-month, 36–72-month, and > 72-month subgroups.
Results
This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21–93) and 66.5 years (31–88). The mean duration of follow-up was 73.1 (12–211) and 56.1 months (24–100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15%) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of < 36-month and 36–72-month subgroups showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (
P
= 0.754 and 0.829, respectively). In the > 72-month subgroup, MBG was better in terms of loosening (
P
< 0.001) and failure rates (
P
= 0.006).
Conclusions
The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. Three modern MBG designs seem to have no difference in failure, at least in the < 36-month and 36–72-month subgroups compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted.
Level of evidence
Level IV, systematic review.
Journal Article
The Effects of Lower-Extremity Total Joint Replacement for Arthritis on Obesity
by
Silva, Mauricio
,
Heisel, Christian
,
Dela Rosa, Mylene A
in
Adult
,
Aged
,
Arthritis - complications
2005
abstractTotal hip or knee replacement patients who are overweight or obese often consider their disabling joint disease a cause for their increased weight. This prospective study investigated weight change in 100 patients after successful total joint replacement to determine whether surgical treatment of hip or knee arthritis leads to weight reduction. Postoperatively, both hip and knee replacement patients gained weight, with no difference in weight gain between hip and knee replacement patients. Younger hip patients gained a significant amount of weight. Patients a with normal body mass index and obese patients did not lose weight, while overweight patients gained a significant amount of weight after surgery. These findings demonstrate successful treatment of lower-extremity arthritis does not lead to weight loss, and obesity should be treated as an independent disease that is not the result of inactivity from arthritis.
Journal Article
Are there differences between stemless and conventional stemmed shoulder prostheses in the treatment of glenohumeral osteoarthritis?
by
Maier, Michael W.
,
Bülhoff, Matthias
,
Klotz, Matthias C.
in
Aged
,
Analysis
,
Antiarthritic agents
2015
Background
Conventional stemmed anatomical shoulder prostheses are widely used in the treatment of glenohumeral osteoarthritis. The stemless shoulder prosthesis, in contrast, is a new concept, and fewer outcome studies are available. Therefore, the purpose of the study was to investigate the early functional outcome and postoperative proprioception of a stemless prosthesis in comparison with a standard stemmed anatomic shoulder prosthesis.
Methods
Twelve patients (mean age 68.3 years [SD ± 5.4]; 5 female, 7 male) with primary glenohumeral osteoarthritis of the shoulder were enrolled, who underwent total shoulder arthroplasty (TSA) with a stemless total shoulder prosthesis, Total Evolution Shoulder System (TESS®; Biomed, France). The control group consisted of twelve (age and gender matched) patients (mean age 67.8 years; [SD ± 7.1]; 9 female, 3 male), getting a TSA with a standard anatomic stemmed prosthesis, Aequalis® Shoulder (Tournier, Lyon, France). Patients were examined the day before and six months after surgery. The pre- and postoperative Constant Score (CS) was evaluated and proprioception was measured in a 3D video motion analysis study using an active angle-reproduction (AAR) test.
Results
Comparing the postoperative CS, there was no significant difference between the groups treated with the TESS® prosthesis (48.0 ± 13.8 points) and the Aequalis® prosthesis (49.3 ± 8.6 points;
p
= 0.792). There was no significant difference in postoperative proprioception between the TESS® group (7.2° [SD ± 2.8]) and the Aequalis® group(8.7° [SD ± 2.7];
p
= 0.196), either. Comparison of in the results of CS and AAR test pre- and postoperatively showed no significant differences between the groups.
Discussion
In patients with glenohumeral osteoarthritis, treated with TSA, the functional and the proprioceptive outcome is comparable between a stemless and a standard stemmed anatomic shoulder prosthesis at early followup.
Conclusion
Further follow-up is necessary regarding the long-term performance of this prosthesis.
Trial registration
Current Controlled Trials
DRKS 00007528
. Registered 17 November 2014
Journal Article
Mid-term progressive loosening of hydroxyapatite-coated femoral stems paired with a metal-on-metal bearing
2019
Background
Several hydroxyapatite (HA)-coated femoral stems from a single manufacturer were identified to have aseptically loosened at mid-term follow-up despite prior radiographic appearance of osseointegration. Possible causes and associated risk factors for stem loosening were explored through radiographic review and implant retrieval analysis.
Methods
Forty-six retrieved hip stems (Corail, DePuy-Synthes) were identified and grouped by bearing type: metal-on-metal (MoM), metal-on-polyethylene, and ceramic-on-ceramic. Stem lucency was graded on post-operative radiographs up to the time of revision. Stems were examined for stripping of the HA coating, taper corrosion, and bearing wear in metal-on-metal cases. Patient demographics, implant design features, and perioperative data were collected from electronic databases and patient charts.
Results
Aseptic loosening occurred in 37% of cases examined. MoM bearings were associated with 7.25 times greater risk of loosening compared to other bearing types. Stem radiolucency was more prevalent for MoM cases and, although not statistically significant, demonstrated progressive lucency. Taper corrosion appeared more severe for MoM cases and correlated with proximal stem radiolucency. Removal of the HA coating from the stems was associated with both taper corrosion and MoM bearing wear. Length of implantation was a confounding factor for the MoM cases.
Conclusion
This study has demonstrated a high risk of mid-term loosening of previously osseointegrated HA-coated femoral stems when paired with a MoM bearing. The mechanism of loosening appears progressive in nature and related to the MoM bearing, possibly interacting with the HA coating. If such loosening is recognized early, rapid revision may allow for retention of the femoral stem.
Journal Article
Uncemented STAR Total Ankle Prostheses : Three to Eight-Year Follow-up of Fifty-one Consecutive Ankles
2003
BackgroundThe feasibility of replacing the ankle joint has been a matter of speculation for a long time. In recent years, the designs of ankle prostheses have been improved, and three designs, all used without bone cement, currently dominate the market. However, documentation of the clinical results of the use of these prostheses is sparse. We reviewed the intermediate-term results of fifty-one consecutive Scandinavian Total Ankle Replacements (STAR).MethodsBetween 1993 and 1999, fifty-one consecutive ankles were replaced with an uncemented, hydroxyapatite-coated STAR total ankle prosthesis. Clinical examination for the present study was performed by one surgeon who had not taken part in the operations. Standardized radiographs were used. Complications and failures were recorded, and patient satisfaction and functional outcome scores were determined for all patients with an unrevised implant.ResultsTwelve ankles had to be revised. Seven were revised because of loosening of at least one of the components; two, because of fracture of the meniscus; and three, for other reasons. A component was exchanged in seven of the twelve revisions, whereas the ankle was successfully fused in the other five. An additional eight ankles had radiographic signs of loosening. The thirty-nine unrevised ankles (thirty-seven patients) were examined after thirty-six to ninety-seven months (median, fifty-two months). The patient was satisfied with the result after thirty-one of the ankle replacements, somewhat satisfied after two, and not satisfied after six. The median Kofoed score increased from 39 points before the surgery to 70 points at the time of the follow-up examination. A median follow-up score of 74 points was recorded when the system described by Mazur et al. and the AOFAS (American Orthopaedic Foot and Ankle Society) system were used. The median range of motion was approximately the same preoperatively and postoperatively. The estimated five-year survival rate, with revision for any reason as the end point, was 0.70. When radiographic loosening of either component was used as the end point, the estimated five-year radiographic survival rate was significantly better for the last thirty-one ankles treated in the series (p = 0.032).ConclusionsTotal ankle replacement may be a realistic alternative to arthrodesis, provided that the components are correctly positioned and are of the correct size. However, the risks of loosening and failure are still higher than are such risks after total hip or total knee replacement.Level of EvidenceTherapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
Journal Article
Treatment of Methicillin-Susceptible Staphylococcus aureus Osteoarticular and Prosthetic Joint Infections: Using the Oxacillin Minimum Inhibitory Concentration to Guide Appropriate Ceftriaxone Use
by
Nguyen, Hien M.
,
Jones, Ronald N.
in
Antibacterial agents
,
Antibiotics. Antiinfectious agents. Antiparasitic agents
,
Antimicrobials
2013
Journal Article