Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
4,245 result(s) for "Laser Doppler"
Sort by:
Historical reviews of the assessment of human cardiovascular function: interrogation and understanding of the control of skin blood flow
Several techniques exist for the determination of skin blood flow that have historically been used in the investigation of thermoregulatory control of skin blood flow, and more recently, in clinical assessments or as an index of global vascular function. Skin blood flow measurement techniques differ in their methodology and their strengths and limitations. To examine the historical development of techniques for assessing skin blood flow by describing the origin, basic principles, and important aspects of each procedure and to provide recommendations for best practise. Venous occlusion plethysmography was one of the earliest techniques to intermittently index a limb’s skin blood flow under conditions in which local muscle blood flow does not change. The introduction of laser Doppler flowmetry provided a method that continuously records an index of skin blood flow (red cell flux) (albeit from a relatively small skin area) that requires normalisation due to high site-to-site variability. The subsequent development of laser Doppler and laser speckle imaging techniques allows the mapping of skin blood flow from larger surface areas and the visualisation of capillary filling from the dermal plexus in two dimensions. The use of iontophoresis or intradermal microdialysis in conjunction with laser Doppler methods allows for the local delivery of pharmacological agents to interrogate the local and neural control of skin blood flow. The recent development of optical coherence tomography promises further advances in assessment of the skin circulation via three-dimensional imaging of the skin microvasculature for quantification of vessel diameter and vessel recruitment.
Grasping Force Control for a Robotic Hand by Slip Detection Using Developed Micro Laser Doppler Velocimeter
The purpose of this paper is to show the feasibility of grasping force control by feeding back signals of the developed micro-laser Doppler velocimeter (μ-LDV) and by discriminating whether a grasped object is slipping or not. LDV is well known as a high response surface velocity sensor which can measure various surfaces—such as metal, paper, film, and so on—thus suggesting the potential application of LDV as a slip sensor for grasping various objects. However, the use of LDV as a slip sensor has not yet been reported because the size of LDVs is too large to be installed on a robotic fingertip. We have solved the size problem and enabled the performance of a feasibility test with a few-millimeter-scale LDV referred to as micro-LDV (μ-LDV) by modifying the design which was adopted from MEMS (microelectromechanical systems) fabrication process. In this paper, by applying our developed μ-LDV as a slip sensor, we have successfully demonstrated grasping force control with three target objects—aluminum block, wood block, and white acrylic block—considering that various objects made of these materials can be found in homes and factories, without grasping force feedback. We provide proofs that LDV is a new promising candidate slip sensor for grasping force control to execute target grasping.
A randomised study of the impact of the SGLT2 inhibitor dapagliflozin on microvascular and macrovascular circulation
Background The sodium–glucose cotransporter 2 inhibitor, dapagliflozin, has been shown to improve diabetic control and reduce blood pressure in patients with type 2 diabetes mellitus. Its effects on micro- and macrovascular structure and function have not yet been reported. Methods This was a prospective, single-centre, placebo-controlled, double-blind, randomised crossover phase IIIb study conducted between March 2014 and February 2015. After a 4-week run-in/washout phase, patients (N = 59) received 6 weeks of either dapagliflozin 10 mg or placebo once daily. They then underwent a 1-week washout before crossing over to the other treatment. Changes in retinal capillary flow (RCF) and arteriole remodelling were evaluated using scanning laser Doppler flowmetry, while micro- and macrovascular parameters in the systemic circulation were assessed using pulse wave analysis. Results Six weeks of dapagliflozin treatment resulted in improvements in diabetes control, including blood glucose and insulin resistance, and reduced office and 24-h ambulatory blood pressure values. RCF decreased from 324 AU at baseline to 308 AU after treatment with dapagliflozin (p = 0.028), while there was little difference after the placebo (318 AU; p = 0.334). Furthermore, the arteriole remodelling that was seen after the placebo phase was not evident after the dapagliflozin phase. Central systolic and diastolic blood pressure values were significantly lower after 6 weeks of dapagliflozin, by 3.0 and 2.2 mmHg, respectively (p = 0.035 and 0.020, respectively vs. baseline). Conclusions Six weeks of dapagliflozin treatment resulted in numerous beneficial effects. In addition to achieving superior diabetes control and blood pressure, parameters associated with the early stages of vascular remodelling were also improved. Trial registration http://www.clinicaltrials.gov (NCT02383238)
Characterizing Musculoskeletal Tissue Mechanics Based on Shear Wave Propagation: A Systematic Review of Current Methods and Reported Measurements
Developing methods for the non-invasive characterization of the mechanics of musculoskeletal tissues is an ongoing research focus in biomechanics. Often, these methods use the speed of shear wave propagation to characterize tissue mechanics (e.g., shear wave elastography and shear wave tensiometry). The primary purpose of this systematic review was to identify, compare, and contrast current methods for exciting and measuring shear wave propagation in musculoskeletal tissues. We conducted searches in the Web of Science, PubMed, and Scopus databases for studies published from January 1, 1900, to May 1, 2020. These searches targeted both shear wave excitation using acoustic pushes and mechanical taps, and shear wave speed measurement using ultrasound, magnetic resonance imaging, accelerometers, and laser Doppler vibrometers. Two reviewers independently screened and reviewed the articles, identifying 524 articles that met our search criteria. Regarding shear wave excitation, we found that acoustic pushes are useful for exciting shear waves through the thickness of the tissue of interest, and mechanical taps are useful for exciting shear waves in wearable applications. Regarding shear wave speed measurement, we found that ultrasound is used most broadly to measure shear waves due to its ability to study regional differences and target specific tissues of interest. The strengths of magnetic resonance imaging, accelerometers, and laser Doppler vibrometers make them advantageous to measure shear wave speeds for high-resolution shear wave imaging, wearable measurements, and non-contact ex vivo measurements, respectively. The advantages that each method offers for exciting and measuring shear waves indicate that a variety of systems can be assembled using currently available technologies to determine musculoskeletal tissue material behavior across a range of innovative applications.
Expanding Applications, Accuracy, and Interpretation of Laser Speckle Contrast Imaging of Cerebral Blood Flow
Laser speckle contrast imaging (LSCI) provides a rapid characterization of cortical flow dynamics for functional monitoring of the microcirculation. The technique stems from interactions of laser light with moving particles. These interactions encode the encountered Doppler phenomena within a random interference pattern imaged in widefield, known as laser speckle. Studies of neurovascular function and coupling with LSCI have benefited from the real-time characterization of functional dynamics in the laboratory setting through quantification of perfusion dynamics. While the technique has largely been relegated to acute small animal imaging, its scalability is being assessed and characterized for both chronic and clinical neurovascular imaging.
Non-Contact Damage Detection under Operational Conditions with Multipoint Laservibrometry
Scanning laser–Doppler vibrometry (SLDV) can localize and visualize damages in mechanical structures. In order to enable scanning, it is necessary to repeat the vibration. Therefore, this technique is not suited to detect emerging hazards in working machinery that change the vibration behavior. A common technique for such cases is monitoring the vibration excited by machine operation with accelerometers. This technique requires mechanical coupling between sensors and the measurement object, which influences the high-frequency vibration responses. However, in the low-frequency range, local damages do not shift resonances or distort operational deflection shapes (ODS) significantly. These alterations in the vibration behavior are tiny and hard to detect. This paper shows that multipoint laservibrometry (MPV) with laser excitation can measure these effects efficiently, and it further demonstrates that damages influence ODSs at frequencies above 20 kHz much stronger than at frequencies below 20 kHz. In addition, ODS-based damage indices are discussed; these are highly sensitive to minute visible changes of the ODSs. In order to enhance the sensitivity of hazard detection, the response vector assurance criterion value is computed and evaluated during operation. The capabilities and limitations of the methodology on the example of a cantilever with manually emerging damage are demonstrated.
Laser doppler flowmetry as a diagnostic tool to detect gingival inflammation: a systematic review
Background The aim of this systematic review was to evaluate whether laser Doppler flowmetry (LDF) as a diagnostic tool is effective in detecting gingival inflammation. Methods This review was conducted and reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and registered at the International Prospective Register of Systematic Reviews (PROSPERO) (registration number CRD42025633576). Two authors independently performed searches in PubMed, Embase, the Cochrane Library, and Scopus. Results In total, 1317 studies were identified, of which 10 met the inclusion criteria after full-text screening. All studies compared perfusion with a healthy control group, seven included a gingivitis group, five included patients with periodontitis, and none included patients with peri-implant disease. Higher blood flow values were found in patients with chronic gingivitis compared to healthy controls, while patients with experimental gingivitis showed no significant difference. Blood flow values in patients with periodontitis showed controversial results. Conclusions LDF shows potential utility in detecting chronic gingival inflammation and altered perfusion patterns between healthy individuals and those with gingival or periodontal inflammation. However, reliably grading perfusion across disease stages and distinguishing between acute gingivitis and chronic periodontitis remains challenging. Notably, there is a lack of data regarding the use of LDF in peri-implant tissues, representing a significant gap in current research. At present, established clinical parameters such as probing depth and bleeding on probing (BOP), remain the gold standard in routine periodontal diagnostics.
Detection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler Flowmeter
Wearable wireless physiological sensors are helpful for monitoring and maintaining human health. Blood flow contains abundant physiological information but it is hard to measure blood flow during exercise using conventional blood flowmeters because of their size, weight, and use of optic fibers. To resolve these disadvantages, we previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems technology. This micro blood flowmeter is wearable and capable of stable measurement signals even during movement. Therefore, we attempted to measure skin blood flow at the forehead, fingertip, and earlobe of seven young men while running as a pilot experiment to extend the utility of the micro blood flowmeter. We measured blood flow in each subject at velocities of 6, 8, and 10 km/h. We succeeded in obtaining stable measurements of blood flow, with few motion artifacts, using the micro blood flowmeter, and the pulse wave signal and motion artifacts were clearly separated by conducting frequency analysis. Furthermore, the results showed that the extent of the changes in blood flow depended on the intensity of exercise as well as previous work with an ergometer. Thus, we demonstrated the capability of this wearable blood flow sensor for measurement during exercise.
Review of methodological developments in laser Doppler flowmetry
Laser Doppler flowmetry is a non-invasive method of measuring microcirculatory blood flow in tissue. In this review the technique is discussed in detail. The theoretical and experimental developments to improve the technique are reviewed. The limitations of the method are elaborated upon, and the research done so far to overcome these limitations is critically assessed.
Comprehensive validation of a compact laser speckle contrast imaging system for vascular function assessment: from the laboratory to the clinic
Proper organ functioning relies on adequate blood circulation; thus, monitoring blood flow is crucial for early disease diagnosis. Laser speckle contrast imaging (LSCI) is a noninvasive technique that is widely used for measuring superficial blood flow. In this study, we developed a portable LSCI system using an 805-nm near-infrared laser and a monochrome CMOS camera with a 10 × macro zoom lens. The system achieved a high-resolution imaging (1280 × 1024 pixels) with a working distance of 10 to 35 cm. The relative flow velocities were visualized via a spatial speckle contrast analysis algorithm with a 5 × 5 sliding window. In vitro experiments demonstrated the system’s ability to image flow velocities in a fluid model, and a linear relationship was observed between the actual flow rate and the relative flow rate obtained by the system. The correlation coefficient ( R 2 ) exceeded 0.83 for volumetric flow rates of 0 to 0.2 ml/min when channel widths were greater than 1.2 mm, and R 2  > 0.94 was obtained for channel widths exceeding 1.6 mm. Comparisons with laser Doppler flowmetry (LDF) revealed a strong positive correlation between the LSCI and LDF results. In vivo experiments captured postocclusive reactive hyperemic responses in rat hind limbs and human palms and feet. The main research contribution is the development of this compact and portable LSCI device, as well as the validation of its reliability and convenience in various scenarios and environments. Future applications of this technology include evaluating blood flow changes during skin injuries, such as abrasions, burns, and diabetic foot ulcers, to aid medical institutions in treatment optimization and to reduce treatment duration. Graphical Abstract