Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
202 result(s) for "Lens and zonules"
Sort by:
Comparison of 13 formulas for IOL power calculation with measurements from partial coherence interferometry
Background/aimsTo compare the accuracy of 13 formulas for intraocular lens (IOL) power calculation in cataract surgery.MethodsIn this retrospective interventional case series, optical biometry measurements were entered into these formulas: Barrett Universal II (BUII) with and without anterior chamber depth (ACD) as a predictor, EVO 2.0 with and without ACD as a predictor, Haigis, Hoffer Q, Holladay 1, Holladay 2AL, Kane, Næser 2, Pearl-DGS, RBF 2.0, SRK/T, T2 and VRF. The mean prediction error (PE), median absolute error (MedAE), mean absolute error and percentage of eyes with a PE within ±0.25, ±0.50, ±0.75 and ±1.00 diopters (D) were calculated.ResultsTwo hundred consecutive eyes were enrolled. With all formulas, the mean PE was zero. The BUII with no ACD had the lowest standard deviation (±0.343 D), followed by the T2 (0.347 D), Kane (0.348 D), EVO 2.0 with no ACD (0.348 D) and BUII with ACD (0.353 D) formulas. The difference among the MedAEs of all formulas was statistically significant (p<0.0001); the lowest values were achieved with the Kane (0.214 D), RBF 2.0 (0.215 D), BUII with and without ACD (0.218 D) and SRK/T (0.223 D). A percentage ranging from 80% to 88.5% of eyes showed a PE within ±0.50 D and all formulas achieved more than 50% of eyes with a PE within ±0.25 D.ConclusionAll investigated formulas achieved good results; there was a tendency towards better outcomes with newer formulas. Traditional formulas can still be considered an accurate option.
Artificial intelligence for anterior segment diseases: Emerging applications in ophthalmology
With the advancement of computational power, refinement of learning algorithms and architectures, and availability of big data, artificial intelligence (AI) technology, particularly with machine learning and deep learning, is paving the way for ‘intelligent’ healthcare systems. AI-related research in ophthalmology previously focused on the screening and diagnosis of posterior segment diseases, particularly diabetic retinopathy, age-related macular degeneration and glaucoma. There is now emerging evidence demonstrating the application of AI to the diagnosis and management of a variety of anterior segment conditions. In this review, we provide an overview of AI applications to the anterior segment addressing keratoconus, infectious keratitis, refractive surgery, corneal transplant, adult and paediatric cataracts, angle-closure glaucoma and iris tumour, and highlight important clinical considerations for adoption of AI technologies, potential integration with telemedicine and future directions.
Universal artificial intelligence platform for collaborative management of cataracts
PurposeTo establish and validate a universal artificial intelligence (AI) platform for collaborative management of cataracts involving multilevel clinical scenarios and explored an AI-based medical referral pattern to improve collaborative efficiency and resource coverage.MethodsThe training and validation datasets were derived from the Chinese Medical Alliance for Artificial Intelligence, covering multilevel healthcare facilities and capture modes. The datasets were labelled using a three-step strategy: (1) capture mode recognition; (2) cataract diagnosis as a normal lens, cataract or a postoperative eye and (3) detection of referable cataracts with respect to aetiology and severity. Moreover, we integrated the cataract AI agent with a real-world multilevel referral pattern involving self-monitoring at home, primary healthcare and specialised hospital services.ResultsThe universal AI platform and multilevel collaborative pattern showed robust diagnostic performance in three-step tasks: (1) capture mode recognition (area under the curve (AUC) 99.28%–99.71%), (2) cataract diagnosis (normal lens, cataract or postoperative eye with AUCs of 99.82%, 99.96% and 99.93% for mydriatic-slit lamp mode and AUCs >99% for other capture modes) and (3) detection of referable cataracts (AUCs >91% in all tests). In the real-world tertiary referral pattern, the agent suggested 30.3% of people be ‘referred’, substantially increasing the ophthalmologist-to-population service ratio by 10.2-fold compared with the traditional pattern.ConclusionsThe universal AI platform and multilevel collaborative pattern showed robust diagnostic performance and effective service for cataracts. The context of our AI-based medical referral pattern will be extended to other common disease conditions and resource-intensive situations.
Long-term evaluation of anterior lens density after implantable collamer lens V4c implantation in patients with myopia over 40 years old
PurposeTo investigate the long-term safety and efficacy of implantable collamer lens (ICL) V4c implantation and changes in the anterior lens density (ALD) in patients with myopia ≥40 years of age.MethodsThis prospective study included 104 eyes of 52 patients >40 years of age before ICL V4c implantation. Spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity (CDVA), intraocular pressure, endothelial cell density, anterior chamber depth, anterior chamber volume and anterior chamber angle preoperatively, at 1 and 3 months, and at 3 years postoperatively were recorded. Pentacam HR was used to analyse ALD changes at a depth of 0.5, 1.0 and 1.5 mm within a 3 mm diameter range around the pupil’s centre.ResultsThe overall follow-up was uneventful at 42±7.1 months; the safety index at last follow-up was 1.26±0.35 and the efficacy index was 0.91±0.41. No eye lost the Snellen line of CDVA, 76% of the eyes had an increase in CDVA for ≥1 line and 62% had an SE within ±0.50 dioptre. The increase in ALD at 0.5, 1 and 1.5 mm was 16.52%±10.46%, 16.72%±9.85% and 17.28%±11.93%, respectively. Preoperative, 1-month and 3-month postoperative ALDs showed correlations with SE and age, and ALD at last follow-up was correlated only with age. There was no correlation between ALD and any other parameters.ConclusionICL V4c shows long-term safety and efficacy in people ≥40 years of age. ALD increased in such patients, which may be related to age and SE.
Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison
Background/AimsTo investigate the influence of anterior chamber depth (ACD) and lens thickness (LT) on 9 intraocular lens (IOL) power calculation formulas accuracy, in patients with normal axial lengths.MethodsRetrospective case series, including patients having uncomplicated cataract surgery with insertion of a single IOL model, divided into three groups according to preoperative ACD. Each group was further subdivided into three subgroups, according to the LT. Using optimised constants, refraction prediction error was calculated for Barrett Universal II, Emmetropia Verifying Optical (EVO) V.2.0, Haigis, Hill-RBF V.2.0, Hoffer Q, Holladay 1, Kane, PEARL-DGS and SRK/T formulas. Mean prediction error, mean and median absolute error (MedAE) and the percentage of eyes within ±0.25D, ±0.50D and ±1.00D were also calculated.ResultsThe study included 695 eyes from 695 patients. For ACD ≤3.0 mm and ≥3.5 mm, mean prediction error of SRK/T, Hoffer Q and Holladay 1 was significantly different from 0 (p<0.05). PEARL-DGS, Kane, EVO V.2.0 and Barrett Universal II were more accurate than the Hoffer Q in ACD ≤3.0 mm (p<0.05). Kane, PEARL-DGS, EVO V.2.0 and Barrett Universal II revealed the lowest variance of mean and MedAE by ACD and LT subgroup. Haigis and Hill-RBF V.2.0 were significantly influenced by LT, independently of the ACD, with a myopic shift with thin lenses and a hyperopic shift with thick lenses (p<0.05).ConclusionNew generation formulas, particularly Kane, PEARL-DGS and EVO V.2.0, seem to be more reliable and stable even in eyes with extreme ACD-LT combinations.
Project hyperopic power prediction: accuracy of 13 different concepts for intraocular lens calculation in short eyes
PurposeTo evaluate the accuracy of intraocular lens (IOL) power calculation in a patient cohort with short axial eye length to assess the performance of IOL power calculation schemes in strong hyperopes.MethodologyThe study was a single centre, single surgeon retrospective consecutive case series at the Augen- und Laserklinik, Castrop-Rauxel, Germany. Inclusion of patients after uneventful cataract surgery implanting either spherical (SA60AT) or aspheric (ZCB00) IOLs. Inclusion criteria were axial eye length <21.5 mm and/or emmetropising IOL power >28.5 D. Lens constants were optimised on a separate patient cohort considering the full bandwidth of axial eye length. Data of one single eye per patient were randomly included. The outcome measures were: mean absolute prediction error (MAE), median absolute prediction error, mean prediction error with SD and median prediction error and the percentage of eyes with an MAE within 0.25 D, 0.5 D, 0.75 D and 1.0 D.ResultsA total of 150 eyes from 150 patients were assessed. Okulix, PEARL-DGS, Kane and Castrop provided a statistically significantly smaller MAE compared with the Hoffer Q and SRK/T formulae.ConclusionIn our patient cohort with short axial eye length, the use of PEARL-DGS, Okulix, Kane or Castrop formulae showed the lowest MAE. The Castrop formula has not been published before, but will be disclosed with a ready-to-use Excel sheet as an addendum to this paper.
Real-world visual outcomes of cataract surgery based on population-based studies: a systematic review
Background/aimsQuantity of cataract surgery has long been an important public health indicator to assess health accessibility, however the quality of care has been less investigated. We aimed to summarise the up-to-date evidences to assess the real-world visual outcomes after cataract surgery in different settings.MethodsA systematic review was undertaken in October 2021. Population-based cross-sectional and longitudinal studies reporting vision-related outcomes after cataract surgery published from 2006 onward were included. A meta-analysis was not planned.ResultsTwenty-six cross-sectional studies from low-income and middle-income countries (LMICs) and five cross-sectional studies from high-income countries (HICs) were included. The proportions of participants with postoperative presenting visual acuity (VA) ≥0.32 (20/60) were all over 70% in all HICS studies, but mostly below 70% in LMICS studies, ranging from 29.9% to 80.5%. Significant difference in postoperative VA was also observed within countries. The leading causes for postoperative visual impairment (defined mostly as presenting VA <20/60) mainly included refractive error, ocular comorbidities and surgical complications including posterior capsule opacification, except for one study in Nigeria wherein the leading cause was aphakia. Only four population-based cohort studies were included with 5–20 years of follow-up time, generally demonstrating no significant changes in postoperative visual outcomes during the follow-up.ConclusionsWe observed large inequality in the visual outcomes and principal causes of visual impairment after cataract surgery among different countries and regions. Structured quality control and enhancement programmes are needed to improve the outcomes of cataract surgery and reduce inequality.
Long-term effects of mild cataract extraction versus laser peripheral iridotomy on anterior chamber morphology in primary angle-closure suspect eyes
AimTo compare lens extraction (LE) and laser peripheral iridotomy (LPI) on anterior segment morphology in primary angle-closure suspect (PACS) eyes.MethodsThis prospective clinical trial included 144 patients with PACS who underwent either LPI or LE. Ultrasound biomicroscopy (UBM) and gonioscopy were performed before and 1 month and 2 years after operation. Main outcomes included UBM parameters and the percentage of residual angle closure.ResultsAt both 1 month and 2 years of follow-up, LE showed a better effect of relieving anterior chamber crowding and widening the drainage angle, as obtaining a larger anterior chamber depth (ACD), angle opening distance, trabecular iris angle (TIA), trabecular iris space area, trabecular ciliary process distance (TCPD) and a smaller iris curvature (I-Curv) and lens vault (LV) (p<0.001). In the LPI group, angle width increased (angle opening distance at 500 µm from the scleral spur, TIA and trabecular iris space area at 500 µm from the scleral spur) and I-Curv decreased (p<0.001) at 1 month postoperatively, with no significant changes in ACD, LV or TCPD. However, at 2 years after LPI, the angle narrowed with the increase in LV over time, and the proportion of residual angle closure also increased from 21.7% to 30.4% (p<0.001). In contrast, after LE, the widened angle width, flattened iris, deepened ACD, decreased LV and increased TCPD all showed good sustainability in the comparison between 1-month and 2-year follow-up. No residual angle closure was observed either at 1 month or 2 years after LE.ConclusionsLE was prior to LPI in widening the drainage angle. After LPI, there was a narrowing of the angle and an increase in the proportion of residual angle closure over time. LE could achieve a wider angle with no residual angle closure, and the anterior segment parameters were sustainable.Trial registration numberChiCTR1800016511.
Cataract surgery practice patterns worldwide: a survey
ObjectiveTo report the results of a global survey on cataract practice patterns related to preoperative, intraoperative and postoperative care, surgical setting and personnel allocation.Methods and analysisAn online 28 questions survey was sent to 240 ophthalmologists asking to describe prevailing trends in their institutions across 38 countries and 5 continents. Questions inquired country, institution, surgical volume and setting, anaesthesia, preoperative and intraoperative examination and postsurgical care. Statistical analysis used crosstabs lambda statistics for non-parametric nominal variables. P value less than 0.05 was considered statistically significant.Results209/240 (87%) ophthalmologists responded: 38% representing public hospitals, 36% private practices and 26% academic sites; overall surgical volume was between 241 700 and 410 500 cataracts per year. There was a significant correlation between type of institution and surgical volume. Complete results available in online (https://freeonlinesurveys.com/r/W6BcLLxy).ConclusionCataract surgery related patterns of perioperative care showed significant difference among respondents, regardless to type of institution, surgical volume and country. Many evidence-based procedures are unevenly practiced around the world and some widespread and expensive habits lack solid scientific evidence while consuming enormous amount of resources both monetary and human. There is a need to reach consensus and share evidence-based practice patterns.
Inherited cataracts: molecular genetics, clinical features, disease mechanisms and novel therapeutic approaches
Cataract is the most common cause of blindness in the world; during infancy and early childhood, it frequently results in visual impairment. Congenital cataracts are phenotypically and genotypically heterogeneous and can occur in isolation or in association with other systemic disorders. Significant progress has been made in identifying the molecular genetic basis of cataract; 115 genes to date have been found to be associated with syndromic and non-syndromic cataract and 38 disease-causing genes have been identified to date to be associated with isolated cataract. In this review, we briefly discuss lens development and cataractogenesis, detail the variable cataract phenotypes and molecular mechanisms, including genotype–phenotype correlations, and explore future novel therapeutic avenues including cellular therapies and pharmacological treatments.