Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Reading Level
      Reading Level
      Clear All
      Reading Level
  • Content Type
      Content Type
      Clear All
      Content Type
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Item Type
    • Is Full-Text Available
    • Subject
    • Publisher
    • Source
    • Donor
    • Language
    • Place of Publication
    • Contributors
    • Location
99,834 result(s) for "Liquid chromatography"
Sort by:
Ultra-high-performance liquid chromatography high-resolution mass spectrometry variants for metabolomics research
Ultra-high-performance liquid chromatography high-resolution mass spectrometry (UHPLC–HRMS) variants currently represent the best tools to tackle the challenges of complexity and lack of comprehensive coverage of the metabolome. UHPLC offers flexible and efficient separation coupled with high-sensitivity detection via HRMS, allowing for the detection and identification of a broad range of metabolites. Here we discuss current common strategies for UHPLC–HRMS-based metabolomics, with a focus on expanding metabolome coverage.This Review surveys ultra-high-performance liquid chromatography high-resolution mass spectrometry (UHPLC–HRMS), a highly sensitive, high-throughput technique that is used for analyzing a broad range of metabolites.
Current trends in supercritical fluid chromatography
Supercritical fluid chromatography (SFC), which employs pressurized carbon dioxide as the major component of the mobile phase, has been known for several decades but has faced a significant resurgence of interest in the recent years, thanks to the development of modern instruments to comply with current expectations in terms of robustness and sensitivity. This review is focused on the recent literature, specifically since the introduction of modern systems but in relation to older literature, to identify the changing trends in application domains. Typically, natural products, bioanalysis, food science, and environmental analyses are all strongly increasing. Together with reduced extra-column volumes in the instruments, the advent of sub-2-μm particles and superficially porous particles in the stationary phases is favoring ultra-high-performance SFC (UHPSFC) allowing for improved resolution and faster analyses, but without the constraints of viscous liquids encountered in ultra-high-performance liquid chromatography (UHPLC). Hyphenation to mass spectrometry is also more frequent and opened the way to new application domains, and raises different issues from liquid chromatography mobile phases, especially due to decompression of carbon dioxide. It is also shown that the frontiers between SFC and HPLC are fading, as switching from one method to the other, even within the course of a single analysis, is facilitated my modern instruments. The present review is not intended to be exhaustive but rather giving a snapshot of recent trends in supercritical fluid chromatography, based on the observation of about 500 papers published in English-written peer-reviewed journals from 2014 to 2018.
Development of a plasma pseudotargeted metabolomics method based on ultra-high-performance liquid chromatography–mass spectrometry
Untargeted methods are typically used in the detection and discovery of small organic compounds in metabolomics research, and ultra-high-performance liquid chromatography–high-resolution mass spectrometry (UHPLC-HRMS) is one of the most commonly used platforms for untargeted metabolomics. Although they are non-biased and have high coverage, untargeted approaches suffer from unsatisfying repeatability and a requirement for complex data processing. Targeted metabolomics based on triple-quadrupole mass spectrometry (TQMS) could be a complementary tool because of its high sensitivity, high specificity and excellent quantification ability. However, it is usually applicable to known compounds: compounds whose identities are known and/or are expected to be present in the analyzed samples. Pseudotargeted metabolomics merges the advantages of untargeted and targeted metabolomics and can act as an alternative to the untargeted method. Here, we describe a detailed protocol of pseudotargeted metabolomics using UHPLC-TQMS. An in-depth, untargeted metabolomics experiment involving multiple UHPLC-HRMS runs with MS at different collision energies (both positive and negative) is performed using a mixture obtained using small amounts of the analyzed samples. XCMS, CAMERA and Multiple Reaction Monitoring (MRM)-Ion Pair Finder are used to find and annotate peaks and choose transitions that will be used to analyze the real samples. A set of internal standards is used to correct for variations in retention time. High coverage and high-performance quantitative analysis can be realized. The entire protocol takes ~5 d to complete and enables the simultaneously semiquantitative analysis of 800–1,300 metabolites. In pseudotargeted metabolomics, transitions used for multiple-reaction monitoring are chosen from mass spectrometry data obtained using mixtures of real samples. Semiquantitative information is obtained without knowing the identity of the compounds.
Simultaneous determination of perfluoroalkyl substances and bile acids in human serum using ultra-high-performance liquid chromatography–tandem mass spectrometry
There is evidence of a positive association between per- and polyfluoroalkyl substances (PFASs) and cholesterol levels in human plasma, which may be due to common reabsorption of PFASs and bile acids (BAs) in the gut. Here we report development and validation of a method that allows simultaneous, quantitative determination of PFASs and BAs in plasma, using 150 μL or 20 μL of sample. The method involves protein precipitation using 96-well plates. The instrumental analysis was performed with ultra-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS), using reverse-phase chromatography, with the ion source operated in negative electrospray mode. The mass spectrometry analysis was carried out using multiple reaction monitoring mode. The method proved to be sensitive, robust, and with sufficient linear range to allow reliable determination of both PFASs and BAs. The method detection limits were between 0.01 and 0.06 ng mL−1 for PFASs and between 0.002 and 0.152 ng mL−1 for BAs, with the exception of glycochenodeoxycholic acid (0.56 ng mL−1). The PFAS measured showed excellent agreement with certified plasma PFAS concentrations in NIST SRM 1957 reference serum. The method was tested on serum samples from 20 healthy individuals. In this proof-of-concept study, we identified significant associations between plasma PFAS and BA levels, which suggests that PFAS may alter the synthesis and/or uptake of BAs.
Commutability assessment of new standard reference materials (SRMs) for determining serum total 25-hydroxyvitamin D using ligand binding and liquid chromatography–tandem mass spectrometry (LC–MS/MS) assays
Commutability is where the measurement response for a reference material (RM) is the same as for an individual patient sample with the same concentration of analyte measured using two or more measurement systems. Assessment of commutability is essential when the RM is used in a calibration hierarchy or to ensure that clinical measurements are comparable across different measurement procedures and at different times. The commutability of three new Standard Reference Materials ® (SRMs) for determining serum total 25-hydroxyvitamin D [25(OH)D], defined as the sum of 25-hydroxyvitamin D 2 [25(OH)D 2 ] and 25-hydroxyvitamin D 3 [25(OH)D 3 ], was assessed through an interlaboratory study. The following SRMs were assessed: (1) SRM 2969 Vitamin D Metabolites in Frozen Human Serum (Total 25-Hydroxyvitamin D Low Level), (2) SRM 2970 Vitamin D Metabolites in Frozen Human Serum (25-Hydroxyvitamin D 2 High Level), and (3) SRM 1949 Frozen Human Prenatal Serum. These SRMs represent three clinically relevant situations including (1) low levels of total 25(OH)D, (2) high level of 25(OH)D 2 , and (3) 25(OH)D levels in nonpregnant women and women during each of the three trimesters of pregnancy with changing concentrations of vitamin D-binding protein (VDBP). Twelve laboratories using 17 different ligand binding assays and eight laboratories using nine commercial and custom liquid chromatography–tandem mass spectrometry (LC–MS/MS) assays provided results in this study. Commutability of the SRMs with patient samples was assessed using the Clinical and Laboratory Standards Institute (CLSI) approach based on 95% prediction intervals or a pre-set commutability criterion and the recently introduced International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approach based on differences in bias for the clinical and reference material samples using a commutability criterion of 8.8%. All three SRMs were deemed as commutable with all LC–MS/MS assays using both CLSI and IFCC approaches. SRM 2969 and SRM 2970 were deemed noncommutable for three and seven different ligand binding assays, respectively, when using the IFCC approach. Except for two assays, one or more of the three pregnancy levels of SRM 1949 were deemed noncommutable or inconclusive using different ligand binding assays and the commutability criterion of 8.8%. Overall, a noncommutable assessment for ligand binding assays is determined for these SRMs primarily due to a lack of assay selectivity related to 25(OH)D 2 or an increasing VDBP in pregnancy trimester materials rather than the quality of the SRMs. With results from 17 different ligand binding and nine LC–MS/MS assays, this study provides valuable knowledge for clinical laboratories to inform SRM selection when assessing 25(OH)D status in patient populations, particularly in subpopulations with low levels of 25(OH)D, high levels of 25(OH)D 2 , women only, or women who are pregnant. Graphical Abstract
Analysis of phenolic compounds in different parts of pomegranate (Punica granatum) fruit by HPLC-PDA-ESI/MS and evaluation of their antioxidant activity: application to different Italian varieties
The analysis of pomegranate phenolic compounds belonging to different classes in different fruit parts was performed by high-performance liquid chromatography coupled with photodiode array and mass spectrometry detection. Two different separation methods were optimized for the analysis of anthocyanins and hydrolyzable tannins along with phenolic acids and flavonoids. Two C18 columns, core–shell and fully porous particle stationary phases, were used. The parameters for separation of phenolic compounds were optimized considering chromatographic resolution and analysis time. Thirty-five phenolic compounds were found, and 28 of them were tentatively identified as belonging to four different phenolic compound classes; namely, anthocyanins, phenolic acids, hydrolyzable tannins, and flavonoids. Quantitative analysis was performed with a mixture of nine phenolic compounds belonging to phenolic compound classes representative of pomegranate. The method was then fully validated in terms of retention time precision, expressed as the relative standard deviation, limit of detection, limit of quantification, and linearity range. Phenolic compounds were analyzed directly in pomegranate juice, and after solvent extraction with a mixture of water and methanol with a small percentage of acid in peel and pulp samples. The accuracy of the extraction method was also assessed, and satisfactory values were obtained. Finally, the method was used to study identified analytes in pomegranate juice, peel, and pulp of six different Italian varieties and one international variety. Differences in phenolic compound profiles among the different pomegranate parts were observed. Pomegranate peel samples showed a high concentration of phenolic compounds, ellagitannins being the most abundant ones, with respect to pulp and juice samples for each variety. With the same samples, total phenols and antioxidant activity were evaluated through colorimetric assays, and the results were correlated among them.
MetaboAnalystR 4.0: a unified LC-MS workflow for global metabolomics
The wide applications of liquid chromatography - mass spectrometry (LC-MS) in untargeted metabolomics demand an easy-to-use, comprehensive computational workflow to support efficient and reproducible data analysis. However, current tools were primarily developed to perform specific tasks in LC-MS based metabolomics data analysis. Here we introduce MetaboAnalystR 4.0 as a streamlined pipeline covering raw spectra processing, compound identification, statistical analysis, and functional interpretation. The key features of MetaboAnalystR 4.0 includes an auto-optimized feature detection and quantification algorithm for LC-MS1 spectra processing, efficient MS2 spectra deconvolution and compound identification for data-dependent or data-independent acquisition, and more accurate functional interpretation through integrated spectral annotation. Comprehensive validation studies using LC-MS1 and MS2 spectra obtained from standards mixtures, dilution series and clinical metabolomics samples have shown its excellent performance across a wide range of common tasks such as peak picking, spectral deconvolution, and compound identification with good computing efficiency. Together with its existing statistical analysis utilities, MetaboAnalystR 4.0 represents a significant step toward a unified, end-to-end workflow for LC-MS based global metabolomics in the open-source R environment. Several bottlenecks exist in metabolomics data analysis. Here, the authors present MetaboAnalystR 4.0 as a unified workflow for LC-MS untargeted metabolomics. It highlights significant improvements in LC-MS2 spectral processing and functional analysis, providing an end-to-end computational pipeline.
Comparison of LC-MS-based methods for the determination of carboxylic acids in animal matrices
Carboxylic acids (CAs) are key players in human and animal metabolism. As they are hardly retained under reversed-phase liquid chromatography (RP-LC) conditions in their native form, derivatization is an option to make them accessible to RP-LC and simultaneously increase their response for mass spectrometric detection. In this work, two RP-LC tandem mass spectrometry-based methods using aniline or 3-nitrophenylhydrazine (3-NPH) as derivatization agents were compared with respect to several factors including completeness of derivatization, apparent recoveries (RAs) in both cow feces and ruminal fluid, and concentrations obtained in feces and ruminal fluid of cows. Anion exchange chromatography coupled to high-resolution mass spectrometry (AIC-HR-MS) served as reference method. Derivatization efficiencies were close to 100% for 3-NPH derivatization but variable (20–100%) and different in solvent solutions and matrix extracts for aniline derivatization. Likewise, average RAs of 13C-labeled short-chain fatty acids as internal standards were around 100% for 3-NPH derivatization but only 45% for aniline derivatization. Quantification of CAs in feces and ruminal fluid of cows initially fed a forage-only diet and then transitioned to a 65% high-grain diet which yielded similar concentrations for 3-NPH derivatization and AIC-HR-MS, but concentrations determined by aniline derivatization were on average five times lower. For these reasons, derivatization with aniline is not recommended for the quantitative analysis of CAs in animal samples.
Occurrence, environmental impact and fate of pharmaceuticals in groundwater and surface water: a critical review
In many nations and locations, groundwater serves as the population's primary drinking water supply. However, pharmaceuticals found in groundwater and surface waters may affect aquatic ecosystems and public health. As a result, their existence in natural raw waters are now more widely acknowledged as a concern. This review summarises the evidence of research on pharmaceuticals' occurrence, impact and fate, considering results from different water bodies. Also, various analytical techniques were reviewed to compare different pharmaceuticals' detection frequencies in water bodies. These include liquid chromatography-mass spectrometry (LC–MS), high-performance liquid chromatography (HPLC), ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), and gas chromatography-mass spectrometry (GC–MS). However, owing to LC–MS's high sensitivity and specification, it is the most reported instrument used for analysis. The PRISMA reviewing methodology was adopted based on relevant literature in order to focus on aim of the review. Among other pharmaceuticals reviewed, sulfamethoxazole was found to be the most frequently detected drug in wastewater (up to 100% detection frequency). The most reported pharmaceutical group in this review is antibiotics, with sulfamethoxazole having the highest concentration among the analysed pharmaceuticals in groundwater and freshwater (up to 5600 ng/L). Despite extensive study and analysis on the occurrence and fate of pharmaceuticals in the environment, appropriate wastewater management and disposal of pharmaceuticals in the water environment are not still monitored regularly. Therefore, there is a need for mainstream studies tailored to the surveillance of pharmaceuticals in water bodies to limit environmental risks to human and aquatic habitats in both mid and low-income nations.