Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Series TitleSeries Title
-
Reading LevelReading Level
-
YearFrom:-To:
-
More FiltersMore FiltersContent TypeItem TypeIs Full-Text AvailableSubjectCountry Of PublicationPublisherSourceTarget AudienceDonorLanguagePlace of PublicationContributorsLocation
Done
Filters
Reset
60,565
result(s) for
"Massage."
Sort by:
Healing massage : an A-Z guide for more than forty medical conditions for professional and home use
Part I. Massage techniques. Introduction ; Hand massage ; Foot massage ; Head massage ; Back massage -- Part II. An A-Z of medical conditions. Ankylosing spondylitis ; Anxiety disorders ; Asthma ; Cancer ; Cerebral palsy ; Cervical and thoracic spondylosis ; Chronic fatigue syndrome / Myalgic encephalopathy ; Constipation ; Cramp ; Down syndrome ; Dupuytren's contracture ; Eating disorders ; Emotional issues and Post-Traumatic Stress Disorder ; Fibromyalgia ; Foot drop ; Frozen shoulder ; Gynecological issues ; Irritable Bowel Syndrome ; Lumbar spondylosis ; Menopause ; Multiple Sclerosis ; Muscular Dystrophy ; Parkinson's disease ; Peripheral neuropathy ; Plantar fasciitis ; Pregnancy ; Raynaud's syndrome ; Repetitive strain injuries ; Restless legs syndrome ; Rotator cuff injury ; Scar tissue ; Sciatica ; Scoliosis ; Shin splint syndrome ; Sinusitis ; Temporomandibular joint disorders ; Tendonitis and Tenosynovitis ; Tennis elbow ; Tension headaches ; Trigeminal neuralgia ; Whiplash ; Winged scapula ; Wrist-drop.
The Acute Effects of a Percussive Massage Treatment with a Hypervolt Device on Plantar Flexor Muscles' Range of Motion and Performance
2020
Handheld percussive massage treatment has gained popularity in recent years, for both therapeutic use and in sports practice. It is used with the goals of increasing flexibility and performance, but also to accelerate recovery. However, until now, there has been no scientific evidence, which proves such effects. Therefore, the purpose of this study was to investigate the effects of a 5-min percussion treatment of the calf muscles on range of motion (ROM) and maximum voluntary contraction (MVC) torque of the plantar flexor muscles. Sixteen healthy male volunteers (mean ± SD; 27.2 ± 4.2 years, 1.79 ± 0.05 m, 79.4 ± 9.1 kg) were tested on two separate days with either a 5-min massage treatment of the calf muscles with a Hypervolt device or the control condition (sitting only). Before and after the treatments, dorsiflexion ROM and MVC torque of the plantar flexor muscles were measured with a dynamometer. Maximum dorsiflexion ROM increased with a large magnitude following the massage treatment by 5.4° (+18.4%; p = 0.002,
= 1.36), while there was no change in the control group. Moreover, MVC torque did not change following both the massage treatment and the control treatment. Similar to a conventional massage by a therapist, ROM can be increased by a handheld percussive massage treatment without having an effect on muscle strength.
Journal Article
Real-time feedback improves chest compression quality in out-of-hospital cardiac arrest: A prospective cohort study
2020
Current guidelines underline the importance of high-quality chest compression during cardiopulmonary resuscitation (CPR), to improve outcomes. Contrary to this many studies show that chest compression is often carried out poorly in clinical practice, and long interruptions in compression are observed. This prospective cohort study aimed to analyse whether chest compression quality changes when a real-time feedback system is used to provide simultaneous audiovisual feedback on chest compression quality. For this purpose, pauses in compression, compression frequency and compression depth were compared.
The study included 292 out-of-hospital cardiac arrests in three consecutive study groups: first group, conventional resuscitation (no-sensor CPR); second group, using a feedback sensor to collect compression depth data without real-time feedback (sensor-only CPR); and third group, with real-time feedback on compression quality (sensor-feedback CPR). Pauses and frequency were analysed using compression artefacts on electrocardiography, and compression depth was measured using the feedback sensor. With this data, various parameters were determined in order to be able to compare the chest compression quality between the three consecutive groups.
The compression fraction increased with sensor-only CPR (group 2) in comparison with no-sensor CPR (group 1) (80.1% vs. 87.49%; P < 0.001), but there were no further differences belonging compression fraction after activation of sensor-feedback CPR (group 3) (P = 1.00). Compression frequency declined over the three study groups, reaching the guideline recommendations (127.81 comp/min vs. 122.96 comp/min, P = 0.02 vs. 119.15 comp/min, P = 0.008) after activation of sensor-feedback CPR (group 3). Mean compression depth only changed minimally with sensor-feedback (52.49 mm vs. 54.66 mm; P = 0.16), but the fraction of compressions with sufficient depth (at least 5 cm) and compressions within the recommended 5-6 cm increased significantly with sensor-feedback CPR (56.90% vs. 71.03%; P = 0.003 and 28.74% vs. 43.97%; P < 0.001).
The real-time feedback system improved chest compression quality regarding pauses in compression and compression frequency and facilitated compliance with the guideline recommendations. Compression depth did not change significantly after activation of the real-time feedback. Even the sole use of a CPR-feedback-sensor (\"sensor-only CPR\") improved performance regarding pauses in compression and compression frequency, a phenomenon known as the 'Hawthorne effect'. Based on this data real-time feedback systems can be expected to raise the quality level in some parts of chest compression quality.
International Clinical Trials Registry Platform of the World Health Organisation and German Register of Clinical Trials (DRKS00009903), Registered 09 February 2016 (retrospectively registered).
Journal Article
Roller-Massager Application to the Quadriceps and Knee-Joint Range of Motion and Neuromuscular Efficiency During a Lunge
by
Behm, David G.
,
Power, Kevin E.
,
Bradbury-Squires, David J.
in
Adult
,
Body Composition
,
Compliance
2015
Roller massagers are used as a recovery and rehabilitative tool to initiate muscle relaxation and improve range of motion (ROM) and muscular performance. However, research demonstrating such effects is lacking.
To determine the effects of applying a roller massager for 20 and 60 seconds on knee-joint ROM and dynamic muscular performance.
Randomized controlled clinical trial.
University laboratory.
Ten recreationally active men (age = 26.6 ± 5.2 years, height = 175.3 ± 4.3 cm, mass = 84.4 ± 8.8 kg).
Participants performed 3 randomized experimental conditions separated by 24 to 48 hours. In condition 1 (5 repetitions of 20 seconds) and condition 2 (5 repetitions of 60 seconds), they applied a roller massager to the quadriceps muscles. Condition 3 served as a control condition in which participants sat quietly.
Visual analog pain scale, electromyography (EMG) of the vastus lateralis (VL) and biceps femoris during roller massage and lunge, and knee-joint ROM.
We found no differences in pain between the 20-second and 60-second roller-massager conditions. During 60 seconds of roller massage, pain was 13.5% (5.7 ± 0.70) and 20.6% (6.2 ± 0.70) greater at 40 seconds and 60 seconds, respectively, than at 20 seconds (P < .05). During roller massage, VL and biceps femoris root mean square (RMS) EMG was 8% and 7%, respectively, of RMS EMG recorded during maximal voluntary isometric contraction. Knee-joint ROM was 10% and 16% greater in the 20-second and 60-second roller-massager conditions, respectively, than the control condition (P < .05). Finally, average lunge VL RMS EMG decreased as roller-massage time increased (P < .05).
Roller massage was painful and induced muscle activity, but it increased knee-joint ROM and neuromuscular efficiency during a lunge.
Journal Article