Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
2
result(s) for
"Medical Devices for Insulin and Metabolic Peptide Delivery"
Sort by:
Insulin Injection Technique Education and Associated Knowledge Factors Among Physicians: Cross-Sectional Survey Study
by
Mokoagow, Md Ikhsan
,
Magfira, Nadya
,
Widyastuti, Anak Agung Arie
in
Diabetes
,
Diabetes Education and Elearning for Health Professionals
,
Diabetes Education and Elearning for Patients
2025
Journal Article
Cutaneous Adverse Effects From Diabetes Devices in Pediatric Patients With Type 1 Diabetes Mellitus: Systematic Review
by
Podwojniak, Alicia
,
Jones, Anne
,
Tan, Isabella J
in
Adolescent
,
Apps, Mobile, Wearables for Diabetes
,
Blood Glucose Self-Monitoring - adverse effects
2024
Continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusions (CSIIs) are the current standard treatment devices for type 1 diabetes (T1D) management. With a high prevalence of T1D beginning in pediatrics and carrying into adulthood, insufficient glycemic control leads to poor patient outcomes. Dermatologic complications such as contact dermatitis, lipodystrophies, and inflammatory lesions are among those associated with CGM and CSII, which reduce glycemic control and patient compliance.
This systematic review aims to explore the current literature surrounding dermatologic complications of CGM and CSII as well as the impact on patient outcomes.
A systematic review of the literature was carried out using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 guidelines using 5 online databases. Included articles were those containing primary data relevant to human participants and adverse reactions to CGM and CSII devices in pediatric populations, of which greater than 50% of the sample size were aged 0-21 years. Qualitative analysis was chosen due to the heterogeneity of outcomes.
Following the application of exclusion criteria, 25 studies were analyzed and discussed. An additional 5 studies were identified after the initial search and inclusion. The most common complication covered is contact dermatitis, with 13 identified studies. Further, 7 studies concerned lipodystrophies, 5 covered nonspecific cutaneous changes, 3 covered unique cutaneous findings such as granulomatous reactions and panniculitis, and 2 discussed user acceptability.
The dermatologic complications of CGM and CSII pose a potential risk to long-term glycemic control in T1D, especially in young patients where skin lesions can lead to discontinuation. Increased manufacturer transparency is critical and further studies are needed to expand upon the current preventative measures such as device site rotation and steroid creams, which lack consistent effectiveness.
Journal Article