Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
138 result(s) for "Multidetector Computed Tomography - standards"
Sort by:
Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer
Objectives The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. Methods The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. Results The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. Conclusions The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. Key points • Multidetector-row computed tomography is widely used to predict pathological nodal status. • An optimal cut-off value of lymph node size has not been determined. • Cut-off values were assessed according to histology and nodal location. • The optimal cut-off values differed based on histology and nodal location. • Diagnostic accuracy was improved by using individual cut-off values for each region.
Adult exposures from MDCT including multiphase studies: first Italian nationwide survey
Objectives To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population. Methods This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest–abdomen–pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDI vol ) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure. Results The 75th percentiles of CTDI vol (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm, respectively; for chest, 15 mGy and 569 mGy cm; spine, 42 mGy and 888 mGy cm; cardiac, 7 mGy and 131 mGy cm for calcium score, and 61 mGy and 1,208 mGy cm for angiographic CT studies. High variability was present in the DLP of abdomen and CAP protocols, where multiphase examinations dominated (71 % and 73 % respectively): for abdomen, 18 mGy, with 555 and 920 mGy cm in abdomen and abdomen–pelvis acquisitions respectively; for CAP, 17 mGy, with 508, 850 and 1,200 mGy cm in abdomen, abdomen–pelvis and CAP acquisitions respectively. Conclusion The results of this survey could help in the definition of updated diagnostic reference levels (DRL). Key Points • Radiation dose associated with multidetector CT (MDCT) is an important health issue. • This national survey assessed dose exposures of 5,668 patients undergoing MDCT. • Dose indices correlate with BMI, voltage, rotation time, pitch and tube current. • These results may contribute to an update of national diagnostic reference levels.
Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening
Objectives To analyse computed tomography (CT) findings of interval and post-screen carcinomas in lung cancer screening. Methods Consecutive interval and post-screen carcinomas from the Dutch–Belgium lung cancer screening trial were included. The prior screening and the diagnostic chest CT were reviewed by two experienced radiologists in consensus with knowledge of the tumour location on the diagnostic CT. Results Sixty-one participants (53 men) were diagnosed with an interval or post-screen carcinoma. Twenty-two (36 %) were in retrospect visible on the prior screening CT. Detection error occurred in 20 cancers and interpretation error in two cancers. Errors involved intrabronchial tumour ( n  = 5), bulla with wall thickening ( n  = 5), lymphadenopathy ( n  = 3), pleural effusion ( n  = 1) and intraparenchymal solid nodules ( n  = 8). These were missed because of a broad pleural attachment ( n  = 4), extensive reticulation surrounding a nodule ( n  = 1) and extensive scarring ( n  = 1). No definite explanation other than human error was found in two cases. None of the interval or post-screen carcinomas involved a subsolid nodule. Conclusions Interval or post-screen carcinomas that were visible in retrospect were mostly due to detection errors of solid nodules, bulla wall thickening or endobronchial lesions. Interval or post-screen carcinomas without explanation other than human errors are rare. Key points • 22 % of missed carcinomas originally presented as bulla wall thickening on CT. • 22 % of missed carcinomas originally presented as endobronchial lesions on CT. • All malignant endobronchial lesions presented as interval carcinomas. • In the NELSON trial subsolid nodules were not a source of missed carcinomas.
Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system
Objective To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Methods Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80kVp-108mAs for CBCT; 120kVp- 300mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal–Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Results Knee CBCT images were rated “excellent” or “good” (median scores 5 and 4) for “bone” and “soft tissue” visualization tasks. Hand CBCT images were rated “excellent” or “adequate” (median scores 5 and 3) for “bone” and “soft tissue” visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26–0.92), and interobserver agreement was fair to moderate (κ ~ 0.27–0.54). Conclusion CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. Key Points • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were “excellent” for “bone” and “good/adequate” for “soft tissue” visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.
Diagnostic accuracy of triple-contrast multi-detector computed tomography for detection of penetrating gastrointestinal injury: a prospective study
Purpose Neither the performance of CT in diagnosing penetrating gastrointestinal injury nor its ability to discriminate patients requiring either observation or surgery has been determined. Materials and methods This was a prospective, single-institutional observational study of patients with penetrating injury to the torso who underwent CT. Based on CT signs, reviewers determined the presence of a gastrointestinal injury and the need for surgery or observation. The primary outcome measures were operative findings and clinical follow-up. CT results were compared with the primary outcome measures. Results Of one hundred and seventy-one patients (72 gunshot wounds, 99 stab wounds; age range, 18–57 years; median age, 28 years) with penetrating torso trauma who underwent CT, 45 % were followed by an operation and 55 % by clinical follow up. Thirty-five patients had a gastrointestinal injury at surgery. The sensitivity, specificity, and accuracy of CT for diagnosing a gastrointestinal injury for all patients were each 91 %, and for predicting the need for surgery, they were 94 %, 93 %, 93 %, respectively. Among the 3 % of patients who failed observation, 1 % had a gastrointestinal injury. Conclusion CT is a useful technique to diagnose gastrointestinal injury following penetrating torso injury. CT can help discriminate patients requiring observation or surgery. Key Points • The most sensitive sign is wound tract extending up to gastrointestinal wall. • The most accurate sign is gastrointestinal wall thickening. • Triple-contrast CT is a useful technique to diagnose gastrointestinal injury. • Triple-contrast CT helps to discriminate patients requiring observation and surgery.
A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures
Objective To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. Methods 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall’s coefficient of concordance. Results CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. Conclusion This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. Key Points • Subjectively, CBCT remains inferior to MSCT in depicting most structures . • Similar diagnostic validity for CBCT and MSCT imaging of distal radius fractures . • CBCT is a possible alternative to MSCT in musculoskeletal imaging . • Visual grading characteristics (VGC) analysis proves useful in analyzing visual grading scales .
Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study
Objectives To assess the influence of tube potential on radiation dose and image quality of third-generation dual-source coronary CT angiography (CTA) in a phantom simulating an obese patient. Methods A thoracic phantom was equipped with tubular inserts containing iodine solution and water. A soft-tissue-equivalent ring around the phantom simulated an obese patient. Images were acquired at tube potentials of 80, 100, 120 and 140 kV with second-generation dual-source CT (DSCT) and 70–150 kV (in 10-kV increments) with third-generation DSCT. Contrast-to-noise ratio (CNR) was calculated and CT dose index was recorded. Results With second-generation DSCT, CNR was highest for 120 kV (19.0) and decreased with lower tube potential (12.0 at 80 kV) owing to disproportionately increased image noise. With third-generation DSCT, 70- and 80-kV acquisitions showed a smaller increase in noise. CNRs for third-generation DSCT were highest for 70 and 80 kV (21.1 and 21.2, respectively). Compared to 120 kV, radiation dose was 68 % and 49 % lower at 70 kV and 80 kV, respectively. Conclusion Third-generation DSCT enables one to perform coronary CTA at 70–80 kV in obese patients without compromising CNR and thus reduces radiation dose by 49–68 %. Key points • Low tube potential CT angiography is currently not suitable for obese patients . • Third-generation DSCT offers substantially increased tube power at low tube potential . • This enables one to perform coronary CT angiography at 70–80 kV in obese patients . • Signal-to-noise ratio is maintained owing to increased tube current . • This approach can be expected to reduce radiation dose by 49–68 % .
Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists
To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = < .004). No significant differences were detected concerning the modalities' specificities (with values between P = .98). Raters' confidence was higher in RED-MDCT and RED-CBCT compared to radiography (P < .001). The diagnostic accuracy of RED-MDCT and RED-CBCT for wrist fractures proved to be similar and in some parts even higher compared to radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.
Sub-milliSievert (sub-mSv) CT colonography: a prospective comparison of image quality and polyp conspicuity at reduced-dose versus standard-dose imaging
Objective To prospectively compare reduced-dose (RD) CT colonography (CTC) with standard-dose (SD) imaging using several reconstruction algorithms. Methods Following SD supine CTC, 40 patients (mean age, 57.3 years; 17 M/23 F; mean BMI, 27.2) underwent an additional RD supine examination (targeted dose reduction, 70–90 %). DLP, CTDI vol , effective dose, and SSDE were compared. Several reconstruction algorithms were applied to RD series. SD-FBP served as reference standard. Objective image noise, subjective image quality and polyp conspicuity were assessed. Results Mean CTDI vol and effective dose for RD series was 0.89 mGy (median 0.65) and 0.6 mSv (median 0.44), compared with 3.8 mGy (median 3.1) and 2.8 mSv (median 2.3) for SD series, respectively. Mean dose reduction was 78 %. Mean image noise was significantly reduced on RD-PICCS (24.3 ± 19HU) and RD-MBIR (19 ± 18HU) compared with RD-FBP (90 ± 33), RD-ASIR (72 ± 27) and SD-FBP (47 ± 14 HU). 2D image quality score was higher with RD-PICCS, RD-MBIR, and SD-FBP (2.7 ± 0.4/2.8 ± 0.4/2.9 ± 0.6) compared with RD-FBP (1.5 ± 0.4) and RD-ASIR (1.8 ± 0.44). A similar trend was seen with 3D image quality scores. Polyp conspicuity scores were similar between SD-FBP/RD-PICCS/RD-MBIR (3.5 ± 0.6/3.2 ± 0.8/3.3 ± 0.6). Conclusion Sub-milliSievert CTC performed with iterative reconstruction techniques demonstrate decreased image quality compared to SD, but improved image quality compared to RD images reconstructed with FBP. Key points • CT colonography dose can be substantially lowered using advanced iterative reconstruction techniques . • Iterative reconstruction techniques (MBIR/PICCS) reduce image noise and improve image quality . • The PICCS/MBIR-reconstructed, reduced-dose series shows decreased 2D/3D image quality compared to the standard-dose series . • Polyp conspicuity was similar on standard-dose images compared to reduced-dose images reconstructed with MBIR/PICCS .
Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT
Objectives Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). Methods We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. Results We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images ( P  < 0.0001). Conclusions Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. Key Points • Computed tomography angiography tends to overestimate stenosis in calcified coronary artery. • Dual-energy CT enables us to suppress calcification of coronary artery lesions. • Calcification-suppressed material density imaging reduces false-positive diagnosis of calcified lesion.