Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
3,420 result(s) for "Multiplex Polymerase Chain Reaction"
Sort by:
Clinical impact and cost-consequence analysis of ePlex® blood culture identification panels for the rapid diagnosis of bloodstream infections: a single-center randomized controlled trial
PurposeTo assess clinical impact and perform cost-consequence analysis of the broadest multiplex PCR panels available for the rapid diagnosis of bloodstream infections (BSI).MethodsSingle-center, randomized controlled trial conducted from June 2019 to February 2021 at a French University hospital with an institutional antimicrobial stewardship program. Primary endpoint was the percentage of patients with optimized antimicrobial treatment 12 h after transmission of positivity and Gram stain results from the first positive BC.ResultsThis percentage was significantly higher in the multiplex PCR (mPCR) group (90/105 = 85.7% %, CI95% [77.5 ; 91.8] vs. 68/107 = 63.6%, CI95% [53.7 ; 72.6]; p < 10− 3) at interim analysis, resulting in the early termination of the study after the inclusion of 309 patients. For patients not optimized at baseline, the median time to obtain an optimized therapy was much shorter in the mPCR group than in the control group (6.9 h, IQR [2.9; 17.8] vs. 26.4 h, IQR [3.4; 47.5]; p = 0.001). Early optimization of antibiotic therapy resulted in a non-statistically significant decrease in mortality from 12.4 to 8.8% (p = 0.306), with a trend towards a shorter median length of stay (18 vs. 20 days; p = 0.064) and a non-significant reduction in the average cost per patient of €3,065 (p = 0.15). mPCR identified all the bacteria present in 88% of the samples.ConclusionDespite its higher laboratory cost, the use of multiplex PCR for BSI diagnosis leads to early-optimised therapy, seems cost-effective and could reduce mortality and length of stay. Their impact could probably be improved if implemented 24/7.
Randomized Trial of Rapid Multiplex Polymerase Chain Reaction–Based Blood Culture Identification and Susceptibility Testing
Background. The value of rapid, panel-based molecular diagnostics for positive blood culture bottles (BCBs) has not been rigorously assessed. We performed a prospective randomized controlled trial evaluating outcomes associated with rapid multiplex PCR (rmPCR) detection of bacteria, fungi, and resistance genes directly from positive BCBs. Methods. A total of 617 patients with positive BCBs underwent stratified randomization into 3 arms: standard BCB processing (control, n = 207), rmPCR reported with templated comments (rmPCR, n = 198), or rmPCR reported with templated comments and real-time audit and feedback of antimicrobial orders by an antimicrobial stewardship team (rmPCR/AS, n = 212). The primary outcome was antimicrobial therapy duration. Secondary outcomes were time to antimicrobial de-escalation or escalation, length of stay (LOS), mortality, and cost. Results. Time from BCB Gram stain to microorganism identification was shorter in the intervention group (1.3 hours) vs control (22.3 hours) (P < .001). Compared to the control group, both intervention groups had decreased broad-spectrum piperacillin-tazobactam (control 56 hours, rmPCR 44 hours, rmPCR/AS 45 hours; P = .01) and increased narrow-spectrum β-lactam (control 42 hours, rmPCR 71 hours, rmPCR/AS 85 hours; P = .04) use, and less treatment of contaminants (control 25%, rmPCR 11%, rmPCR/AS 8%; P = .015). Time from Gram stain to appropriate antimicrobial de-escalation or escalation was shortest in the rmPCR/AS group (de-escalation: rmPCR/AS 21 hours, control 34 hours, rmPCR 38 hours, P < .001; escalation: rmPCR/AS 5 hours, control 24 hours, rmPCR 6 hours, P = .04). Groups did not differ in mortality, LOS, or cost. Conclusions. rmPCR reported with templated comments reduced treatment of contaminants and use of broad-spectrum antimicrobials. Addition of antimicrobial stewardship enhanced antimicrobial de-escalation. Clinical Trials Registration. NCT01898208.
Performance and impact of a multiplex PCR in ICU patients with ventilator-associated pneumonia or ventilated hospital-acquired pneumonia
Background Early appropriate antibiotic therapy reduces morbidity and mortality of severe pneumonia. However, the emergence of bacterial resistance requires the earliest use of antibiotics with the narrowest possible spectrum. The Unyvero Hospitalized Pneumonia (HPN, Curetis) test is a multiplex PCR (M-PCR) system detecting 21 bacteria and 19 resistance genes on respiratory samples within 5 h. We assessed the performance and the potential impact of the M-PCR on the antibiotic therapy of ICU patients. Methods In this prospective study, we performed a M-PCR on bronchoalveolar lavage (BAL) or plugged telescoping catheter (PTC) samples of patients with ventilated HAP or VAP with Gram-negative bacilli or clustered Gram-positive cocci. This study was conducted in 3 ICUs in a French academic hospital: the medical and infectious diseases ICU, the surgical ICU, and the cardio-surgical ICU. A multidisciplinary expert panel simulated the antibiotic changes they would have made if the M-PCR results had been available. Results We analyzed 95 clinical samples of ventilated HAP or VAP (72 BAL and 23 PTC) from 85 patients (62 males, median age 64 years). The median turnaround time of the M-PCR was 4.6 h (IQR 4.4–5). A total of 90/112 bacteria were detected by the M-PCR system with a global sensitivity of 80% (95% CI, 73–88%) and specificity of 99% (95% CI 99–100). The sensitivity was better for Gram-negative bacteria (90%) than for Gram-positive cocci (62%) ( p  = 0.005). Moreover, 5/8 extended-spectrum beta-lactamases (CTX-M gene) and 4/4 carbapenemases genes (3 NDM, one oxa-48) were detected. The M-PCR could have led to the earlier initiation of an effective antibiotic in 20/95 patients (21%) and to early de-escalation in 37 patients (39%) but could also have led to one (1%) inadequate antimicrobial therapy. Among 17 empiric antibiotic treatments with carbapenems, 10 could have been de-escalated in the following hours according to the M-PCR results. The M-PCR also led to 2 unexpected diagnosis of severe legionellosis confirmed by culture methods. Conclusions Our results suggest that the use of a M-PCR system for respiratory samples of patients with VAP and ventilated HAP could improve empirical antimicrobial therapy and reduce the use of broad-spectrum antibiotics.
Multiplex real-time PCR in non-invasive respiratory samples to reduce antibiotic use in community-acquired pneumonia: a randomised trial
We assessed whether multiplex real-time PCR plus conventional microbiological testing is safe and more effective than conventional microbiological testing alone for reducing antibiotic use in community-acquired pneumonia (CAP). In this randomised trial, we recruited adults hospitalised with CAP at four Spanish hospitals. Patients were randomly assigned (1:1) to undergo either multiplex real-time PCR in non-invasive respiratory samples plus conventional microbiological testing or conventional microbiological testing alone. The primary endpoint was antibiotic use measured by days of antibiotic therapy (DOT). Between February 20, 2020, and April 24, 2023, 242 patients were enrolled; 119 were randomly assigned to multiplex real-time PCR plus conventional microbiological testing and 123 to conventional microbiological testing alone. All but one of the patients allocated to multiplex real-time PCR plus conventional microbiological testing underwent PCR, which was performed in sputum samples in 77 patients (65.2%) and in nasopharyngeal swabs in 41 (34.7%). The median DOT was 10.04 (IQR 7.98, 12.94) in the multiplex PCR plus conventional microbiological testing group and 11.33 (IQR 8.15, 16.16) in the conventional microbiological testing alone group (difference −1.04; 95% CI, −2.42 to 0.17; p  = 0.093). No differences were observed in adverse events and 30-day mortality. Our findings do not support the routine implementation of multiplex real-time PCR in the initial microbiological testing in hospitalised patients with CAP. Clinicaltrials.gov registration: NCT04158492. Here, the authors report the results of a randomised trial assessing whether adding multiplex real-time PCR to conventional testing reduces antibiotic use in community-acquired pneumonia and observe no significant reduction in days of antibiotic therapy or in 30-day mortality.
A sensitive and affordable multiplex RT-qPCR assay for SARS-CoV-2 detection
With the ongoing COVID-19 (Coronavirus Disease 2019) pandemic, caused by the novel coronavirus SARS-CoV-2 (Severe Acute Respiratory Syndrome Coronavirus 2), there is a need for sensitive, specific, and affordable diagnostic tests to identify infected individuals, not all of whom are symptomatic. The most sensitive test involves the detection of viral RNA using RT-qPCR (quantitative reverse transcription PCR), with many commercial kits now available for this purpose. However, these are expensive, and supply of such kits in sufficient numbers cannot always be guaranteed. We therefore developed a multiplex assay using well-established SARS-CoV-2 targets alongside a human cellular control ( RPP30 ) and a viral spike-in control (Phocine Herpes Virus 1 [PhHV-1]), which monitor sample quality and nucleic acid extraction efficiency, respectively. Here, we establish that this test performs as well as widely used commercial assays, but at substantially reduced cost. Furthermore, we demonstrate >1,000-fold variability in material routinely collected by combined nose and throat swabbing and establish a statistically significant correlation between the detected level of human and SARS-CoV-2 nucleic acids. The inclusion of the human control probe in our assay therefore provides a quantitative measure of sample quality that could help reduce false-negative rates. We demonstrate the feasibility of establishing a robust RT-qPCR assay at approximately 10% of the cost of equivalent commercial assays, which could benefit low-resource environments and make high-volume testing affordable.
Diagnostic performance of Pneumonia multiplex PCR in critically ill immunocompromised patients
Background Admissions of immunocompromised patients to intensive care units (ICUs) are on the increase. The main reason for admission is acute respiratory failure, predominantly of infectious origin. In such circumstances, early and appropriate antibiotic therapy guarantees a better prognosis. Rapid diagnostic techniques such as multiplex polymerase chain reaction (PCR) have shown their value in both diagnosis and treatment in immunocompetent patients. To date, little data are available on immunocompromised patients. Methods In this retrospective, single-center study, we analyzed data from critically ill immunocompromised patients admitted for acute respiratory failure requiring invasive ventilation, in whom a respiratory specimen was taken and processed simultaneously by BioFire FilmArray Pneumonia Panel multiplex PCR (BFPPm PCR) and conventional culture (CC). Samples had to be taken from deep respiratory tracts less than 48 h after mechanical ventilation. The primary endpoint was the evaluation of the diagnostic performance of BFPP mPCR compared with CC. The secondary endpoint was the therapeutic impact of the results of BFPP mPCR. Results One hundred and fourteen patients were included, with immunosuppression mainly of a hematological (35.1%) and oncological (35.1%) nature. The mPCR positivity rate was 36.8%, with the majority identifying enterobacteria (51%) and a median turnaround time of between 2h30 and 4 h. Comparison of rapid techniques with CC showed sensitivity of 89%, specificity of 83%, predictive positive value of 52% and negative predictive value of 98%. Concordance between the two techniques was complete in 84.2% of cases. mPCR enabled antibiotic therapy to be modified in 17.5% of cases, mainly de-escalation. Conclusion The use of mPCR in the diagnosis of pneumonia in immunocompromised patients shortens the time required to obtain results, and is particularly effective in eliminating the presence of multi-resistant germs. Bacteria detected in culture and not included in the mPCR spectrum were mostly bacteria of low pathogenicity or sensitive to the antibiotics usually prescribed. The mPCR technique could reduce exposure to broad-spectrum antibiotics in this population.
Usefulness of point-of-care multiplex PCR to rapidly identify pathogens responsible for ventilator-associated pneumonia and their resistance to antibiotics: an observational study
Background The use of multiplex PCR to shorten time to identification of pathogens and their resistance mechanisms for patients with ventilator-associated pneumonia (VAP) is attractive, but poorly studied. The multiplex PCR–based Unyvero pneumonia cartridge assay can directly identify 20 bacteria and one fungus, amongst the most frequently causing VAP, and 19 of their resistance markers in clinical specimens (bronchoalveolar lavage or tracheal aspirate), with a turnaround time of 4–5 h. We performed this study to evaluate the concordance between the multiplex PCR–based Unyvero pneumonia cartridge assay and conventional microbiological techniques to identify pathogens and their resistance mechanisms in patients with VAP. Methods All patients suspected of having VAP (January 2016 to January 2019), who underwent fiberoptic bronchoscopy with bronchoalveolar lavage fluid (BALF) and whose BALF microscopy examination revealed intracellular bacteria, were included. BALF conventional cultures (gold standard), antimicrobial susceptibility testing and processing for the Unyvero pneumonia cartridge were done. Culture and Unyvero results were compared. Results Compared to cultures of the 93 samples processed for both techniques, Unyvero correctly identified pathogens in 68 (73%) proven VAP episodes, was discordant for 25 (27%), detected no pathogen in 11 and overdetected a not otherwise found pathogen in six. For the eight remaining discordant results, the pathogen responsible for VAP was not included in the Unyvero cartridge panel or it grew at a non-significant level in culture. Amongst the 31 (33%) resistance mechanism discordances observed, 22 were resistance detection failures and 24 concerned Pseudomonas aeruginosa . Conclusions Compared to conventional microbiological cultures, the Unyvero pneumonia cartridge had poor diagnostic performance: it correctly identified pathogens and their resistance mechanisms in 73% and 67% of VAP cases, respectively. The lack of performance on the resistance mechanism was more pronounced when the pathogen detected was a Pseudomonas aeruginosa .
Leukocyte telomere length and depression, anxiety and stress and adjustment disorders in primary health care patients
Background The primary aim was to examine possible differences in telomere length between primary health care patients, with depression, anxiety or stress and adjustment disorders, and healthy controls. The second aim was to examine the association between telomere length and baseline characteristics in the patients. The third aim was to examine the potential effects of the 8-week treatments (mindfulness-based group therapy or treatment as usual, i.e. mostly cognitive-based therapy) on telomere length, and to examine whether there was a difference in the potential effect on telomere length between the two groups. Methods A total of 501 individuals including 181 patients (aged 20–64 years), with depression, anxiety and stress and adjustment disorders, and 320 healthy controls (aged 19–70 years) were recruited in the study. Patient data were collected from a randomized controlled trial comparing mindfulness-based group therapy with treatment as usual. We isolated genomic DNA from blood samples, collected at baseline and after the 8-week follow-up. Telomere length was measured by quantitative real-time (qRT)-PCR. Results Telomere length was significantly shorter in the patients (mean = 0.77 ± 0.12,), compared to the controls (mean = 0.81 ± 0.14) ( p  = 0.006). The difference in telomere length remained significant after controlling for age and sex. Old age, male sex and being overweight were associated with shorter telomere length. There was no significant difference in telomere length between baseline and at the 8-week follow-up in any of the treatment groups and no difference between the two groups. Conclusion Our findings confirm that telomere length, as compared with healthy controls, is shortened in patients with depression, anxiety and stress and adjustment disorders. In both groups (mindfulness-based group therapy or treatment as usual), the telomere length remained unchanged after the 8-week treatment/follow-up and there was no difference between the two groups. Trial registration (ClinicalTrials.gov ID: NCT01476371 ) Registered November 11, 2011.
Development of a Triplex Real-Time PCR Assay to Detect Echinococcus Species in Canid Fecal Samples
Echinococcosis is a zoonotic disease with great significance to public health, and appropriate detection and control strategies should be adopted to mitigate its impact. Most cases of echinococcosis are believed to be transmitted by the consumption of food and/or water contaminated with canid stool containing Echinococcus spp. eggs. Studies assessing Echinococcus multilocularis, Echinococcus granulosus sensu stricto, and Echinococcus shiquicus coinfection from contaminated water-derived, soil-derived, and food-borne samples are scarce, which may be due to the lack of optimized laboratory detection methods. The present study aimed to develop and evaluate a novel triplex TaqMan-minor groove binder probe for real-time polymerase chain reaction (rtPCR) to simultaneously detect the 3 Echinococcus spp. mentioned above from canid fecal samples in the Qinghai-Tibetan Plateau area (QTPA). The efficiency and linearity of each signal channel in the triplex rtPCR assay were within acceptable limits for the range of concentrations tested. Furthermore, the method was shown to have good repeatability (standard deviation ≤0.32 cycle threshold), and the limit of detection was estimated to be 10 copies plasmid/µl reaction. In summary, the evaluation of the present method shows that the newly developed triplex rtPCR assay is a highly specific, precise, consistent, and stable method that could be used in epidemiological investigations of echinococcosis.
Germline mutations in BRCA1 and BRCA2 in epithelial ovarian cancer patients in Brazil
Background Approximately 8–15% epithelial ovarian cancer patients are BRCA1 or BRCA2 germline mutation carriers. Brazilian inhabitants may have peculiar genetic characteristics associated with ethnic diversity, and studies focusing on the entire BRCA1/BRCA2 gene sequencing in Brazilian ovarian cancer patients are still lacking. The aim of this study was to evaluate BRCA1/2 mutations, through entire gene sequencing, in a Brazilian population of women with epithelial ovarian cancer. Methods In a cross sectional study performed in one reference centre for cancer treatment in São Paulo, Brazil, 100 patients diagnosed with epithelial ovarian cancer unselected for family history of breast and/or ovarian cancer were included. The complete coding sequence of BRCA1 /2 genes was evaluated through Next-Generation or capillary sequencing. Large deletions were investigated through Multiplex Ligation-dependent Probe Amplification (MLPA). Results Nineteen pathogenic mutations ( BRCA1 : n  = 17 and BRCA2 : n  = 2) featuring 14 different mutations, including two large deletions in BRCA1 (exon 1–2 deleted and exon 5–7 deleted) were identified. Three mutations were detected more than once (c.3331_3334delCAAG, c.5266dupC and c.4484G > T). Two novel frameshift mutations were identified, one in BRCA1 (c.961_962delTG) and one in BRCA2 (c.1963_1963delC). BRCA1/2 mutations were seen in 35.5% of the patients with first and/or second-degree relatives with breast and/or ovarian cancer. Nineteen variants of uncertain significance (VUS) were detected ( BRCA1 : n  = 2 and BRCA2 : n  = 17), including five distinct missense variants ( BRCA1 : c.5348 T > C; BRCA2 : c.2350A > G, c.3515C > T, c.7534C > T, and c.8351G > A). Conclusions Among epithelial ovarian cancer patients unselected for family history of cancer, 19% were BRCA1/2 germline mutation carriers. Almost ¾ of the BRCA mutations, including two large deletions, were detected only once. Our work emphasizes the need of entire gene sequencing and MLPA screening in Brazil.