Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Is Full-Text Available
      Is Full-Text Available
      Clear All
      Is Full-Text Available
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Subject
    • Publisher
    • Source
    • Language
    • Place of Publication
    • Contributors
3,979 result(s) for "Optical scanners"
Sort by:
New Challenges in Tribology: Wear Assessment Using 3D Optical Scanners
Wear is a significant mechanical and clinical problem. To acquire further knowledge on the tribological phenomena that involve freeform mechanical components or medical prostheses, wear tests are performed on biomedical and industrial materials in order to solve or reduce failures or malfunctions due to material loss. Scientific and technological advances in the field of optical scanning allow the application of innovative devices for wear measurements, leading to improvements that were unimaginable until a few years ago. It is therefore important to develop techniques, based on new instrumentations, for more accurate and reproducible measurements of wear. The aim of this work is to discuss the use of innovative 3D optical scanners and an experimental procedure to detect and evaluate wear, comparing this technique with other wear evaluation methods for industrial components and biomedical devices.
3D Surface Scanning—A Novel Protocol to Characterize Virtual Nickel–Titanium Endodontic Instruments
The nickel–titanium (NiTi) instruments’ geometry plays an important role in their performance and behavior. The present assessment intends to validate and test the applicability of a 3D surface scanning method using a high-resolution laboratory-based optical scanner to create reliable virtual models of NiTi instruments. Sixteen instruments were scanned using a 12-megapixel optical 3D scanner, and methodological validation was performed by comparing quantitative and qualitative measurements of specific dimensions and identifying some geometric features of the 3D models with images obtained through scanning electron microscopy. Additionally, the reproducibility of the method was assessed by calculating 2D and 3D parameters of three different instruments twice. The quality of the 3D models created by two different optical scanners and a micro-CT device was compared. The 3D surface scanning method using the high-resolution laboratory-based optical scanner allowed for the creation of reliable and precise virtual models of different NiTi instruments with discrepancies varying from 0.0002 to 0.0182 mm. The reproducibility of measurements performed with this method was high, and the acquired virtual models were adequate for use in in silico experiments, as well as for commercial or educational purposes. The quality of the 3D model obtained using the high-resolution optical scanner was superior to that acquired by micro-CT technology. The ability to superimpose virtual models of scanned instruments and apply them in Finite Element Analysis and educational purposes was also demonstrated.
Evaluation of the Surface Topography and Deformation of Vertical Thin-Wall Milled Samples from the Nickel Alloy Inconel 625
During the production of components, manufacturers of structures are obliged to meet certain requirements and ensure appropriate quality characteristics. It is especially important during the manufacturing of thin-walled structures, which are subject to many errors during machining due to the reduced rigidity of the products, including the deformation of thin walls, which may be the result of the vibration of the system. The appearance of vibrations reduces the quality of the machined surface affecting the increase in the values of surface topography parameters—waviness and roughness. Thin-wall structures—titanium or nickel alloy, among others—play a key role in the aerospace industry, which constantly strives to reduce the weight of the entire structure while meeting requirements. The present work focuses on the evaluation of the parameters of surface topography, dimensional and shape accuracy during the milling of nickel alloy Inconel 625 samples containing a thin wall in a vertical orientation. The experiment was conducted under controlled cutting conditions using a constant material removal rate. As part of the surface topography section, the distribution of waviness, Wa and Wz, and roughness, Ra and Rz, was determined in selected measurement areas in the direction parallel to the direction of the feed motion. Dimensional deviations, measured with a 3D optical scanner, were determined in selected cross sections in the direction perpendicular and parallel to the bottom of the sample presenting the deflection of the thin-walled structure. The results provide information that the used parameter sets affect the measured quantities to varying degrees.
Dimensional Deviations of Horizontal Thin Wall of Titanium Alloy Ti6Al4V Determined by Optical and Contact Methods
Thin-walled structures are used in many industries. The need to use such elements is dictated by the desire to reduce the weight of the finished product, as well as to reduce its cost. The most common method of machining such elements is the use of milling, which makes it possible to make a product of almost any shape. However, several undesirable phenomena occur during the milling of thin-walled structures. The main phenomenon is a deformation of the thin wall resulting from its reduced stiffness. Therefore, it is necessary to control the dimensional and shape accuracy of finished products, which is carried out using various measuring instruments. The development of newer measuring methods such as optical methods is being observed. One of the newer measuring machines is the 3D optical scanner. In the present experiment, thin-walled samples in horizontal orientation of Ti6Al4V titanium alloy were machined under controlled cutting conditions. During machining, the cutting speed and feed rate were assumed constant, while the input factors were the tool and cutting strategy. This paper presents graphs of deviations in the determined cross-section planes of thin-walled structures using a 3D optical scanner and a coordinate measuring machine. A correlation was made between the results obtained from the measurement by the optical method and those determined by the contact method. A maximum discrepancy of about 8% was observed between the methods used.
A Precessing-Coin-like Rotary Actuator for Distal Endoscope Scanners: Proof-of-Concept Study
This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe’s optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging. This new scanner architecture removes the need for a separate prism mirror and holding mechanics to drastically simplify the scanner design and thus, potentially enhancing device miniaturization and reliability. The first proof-of-concept is developed using 3D printing and experimentally analyzed to reveal the ability of both angular stepping at 45° and high-speed rotation up to 1500 rpm within the biologically safe temperature range, a key function for multimodal imaging. Preliminary optical testing demonstrates continuous circumferential scanning of the laser beam with no blind spot caused by power leads to the actuator. The results indicate the fundamental feasibility of the developed actuator as an endoscopic distal scanner, a significant step to further development toward advancing optical endoscope technology.
Accuracy of the Conventional Facial Impression Method and Three-Dimensional Auricular Shape Data Obtained Using Extra- and Intraoral Optical Scanners
Background: Facial impression methods have been used to fabricate auricular prostheses; however, deformation due to the weight of the impression material remains. This study aimed to investigate the accuracy of auricular three-dimensional (3D) data obtained using a 3D optical extraoral scanner and an intraoral scanner compared with that of a conventional facial impression method. Methods: Six auricles were digitized using an extraoral scanner with and without a reference board around the auricle and an intraoral scanner. Auricle casts fabricated using auricle impressions were scanned using a laboratory scanner. All obtained data were superimposed, and the 3D deformations of the different methods were evaluated using measurement mapping and root mean square (RMS) values. The length, width, and height of the auricular casts and scanned data were measured and compared with the sizes of the original auricles measured using a caliper. Results: Large displacements of the back and margins of the ears were observed, and the RMS values ranged from 0.5–2.4 mm. Larger widths and smaller heights of the scanned and impression data were observed compared to the anthropometric ear data. Conclusions: The study concluded that the fabrication of auricular prostheses using optical scanning is clinically acceptable. All examined scanning techniques demonstrated discrepancies within acceptable limits when compared to the conventional facial impression method.
Application of a 3D Scanner in Robotic Measurement of Aviation Components
The aviation industry is associated with high precision and accuracy standards of the manufactured components, and thus the need to ensure precise quality control. Measurement processes, depending on the manufactured components, take place before, during and after the processing stage. Optical scanners can be used for these measurements, the measurement results of which can be displayed on the operator panel or used to prepare a report. The innovative approach is to measure, compare the results with a pattern, send the deviations to a neural decision-making system, select the forces and send the results to a robot controller for adaptive machining. The presented proprietary solution includes a data acquisition system, a neural decision-making system and a robot that carries out the machining process via force control. The proposed solution was verified on aviation components. During the process parameter optimization stage for the diffuser and ADT gearbox, the points describing the change in width of the chamfer being performed and the blade thickness in the control sections were approximated.
Comparative Evaluation of Digitization of Diagnostic Dental Cast (Plaster) Models Using Different Scanning Technologies
Rapidly developing digital dental technologies have substantially simplified the documentation of plaster dental models. The large variety of available scanners with varying degrees of accuracy and cost, however, makes the purchase decision difficult. This study assessed the digitization accuracy of a cone-beam computed tomography (CBCT) and an intraoral scanner (IOS), as compared to a desktop optical scanner (OS). Ten plaster dental models were digitized three times (n = 30) with each scanner. The generated STL files were cross-compared, and the RMS values were calculated. Conclusions were drawn about the accuracy with respect to precision and trueness levels. The precision of the CBCT scanner was similar to the desktop OS reference, which both had a median deviation of 0.04 mm. The IOS had statistically significantly higher deviation compared to the reference OS, with a median deviation of 0.18 mm. The trueness values of the CBCT was also better than that of IOS—median differences of 0.14 and 0.17 mm, respectively. We conclude that the tested CBCT scanner is a highly accurate and user-friendly scanner for model digitization, and therefore a valuable alternative to the OS. The tested IOS was generally of lower accuracy, but it can still be used for plaster dental model digitization.
Assessment of the Efficiency of Measuring Foot and Ankle Edema with a 3D Portable Scanner
Background: To prospectively evaluate the reliability of a portable optical scanner compared to the water displacement technique for volumetric measurements of the foot and ankle and to compare the acquisition time associated with these two methods. Methods: Foot volume was measured in 29 healthy volunteers (58 feet, 24 females and 5 males) by a 3D scanner (UPOD-S 3D Laser Full-Foot Scanner®) and by water displacement volumetry. Measurements were performed on both feet, up to a height of 10 cm above the ground. The acquisition time for each method was evaluated. The Kolmogorov-Smirnov test, Lin’s Concordance Correlation Coefficient, and a Student’s t-test were performed. Results: Mean foot volume was 869.7 +/− 165.1 cm3 (3D scanner) versus 867.9 +/− 155.4 cm3 (water-displacement volumetry) (p < 10−5). The concordance of measurements was 0.93, indicative of a high correlation between the two techniques. Volumes were 47.8 cm3 lower when using the 3D scanner versus water volumetry. After statistically correcting this underestimation, the concordance was improved (0.98, residual bias = −0.03 +/− 35.1 cm3). The mean examination time was 4.2 +/− 1.7 min (3D optical scanner) versus 11.1 +/− 2.9 min (water volumeter) (p < 10−4). Conclusions: Ankle/foot volumetric measurements performed using this portable 3D scanner are reliable and fast and can be used in clinical practice and research.