Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
66,184 result(s) for "Outlets"
Sort by:
Endoscopic ultrasound-guided gastroenterostomy versus open surgical gastrojejunostomy: clinical outcomes and cost effectiveness analysis
BackgroundEarly data suggests that endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is a safe and efficacious option for gastric outlet obstruction (GOO). However, there is a scarcity of data comparing outcomes with open gastrojejunostomy (OGJ).MethodsSingle-center retrospective cohort study of adult patients hospitalized with GOO who underwent EUS-GE or OGJ between January 1, 2014 and February 28, 2020. Primary outcomes were technical and clinical success.ResultsSixty-six patients were included of which 40 (60.0%) underwent EUS-GE and 26 (40.0%) underwent OGJ. Baseline characteristics were similar with respect to age (70.5 vs 69.7, p = 0.81), sex (42.5% vs 42.3% female, p = 0.99), median length of follow-up (98.0 vs 166.5 days, p = 0.8), prior failed intervention for GOO (22.5% vs 26.9%, p = 0.68), and the presence of altered anatomy (12.5% vs 30.8%, p = 0.07) between EUS-GE and OGJ, respectively. Technical success was achieved in 37 (92.5%) of EUS-GE and 26 (100%) of OGJ patients (p = 0.15). EUS-GE was associated with faster resumption of oral intake (1.3 vs 4.7 days, p < 0.001) and shorter length of stay (5 vs 14.5 days, p < 0.001). There were no significant differences in symptom recurrence (17.5% vs 19.2%, HR 1.85, CI 0.52–6.65, p = 0.34), reintervention (20% vs 11.5%, HR 0.82, CI 0.22–3.15, p = 0.78), death within 30 days (12.5% vs 3.8%, HR 0.80, CI 0.09–6.85, p = 0.84), or 30-day readmission (17.5% vs 24.1%, HR 1.69, CI 0.53–5.41, p = 0.37) between EUS-GE and OGJ, respectively. EUS-GE patients initiated chemotherapy sooner (17.7 vs 31.3 days, p = 0.033) and had lower overall costs as compared to OGJ ($49,387 vs $124,192, p < 0.001).ConclusionThere were no significant differences in technical or clinical success, symptom recurrence, reintervention, 30-day readmission, or 30-day mortality between EUS-GE and OGJ. EUS-GE patients experienced shorter delays to resumption of oral intake and chemotherapy, had shorter lengths of stay, and reduced hospital costs. Further prospective comparative studies are warranted to verify our results.
EUS-guided gastroenterostomy is comparable to enteral stenting with fewer re-interventions in malignant gastric outlet obstruction
Background and aims Endoscopic enteral stenting (ES) in malignant gastric outlet obstruction (GOO) is limited by high rates of stent obstruction. EUS-guided gastroenterostomy (EUS-GE) is a novel procedure that potentially offers sustained patency without tumor ingrowth/overgrowth. The aim of this study is to compare EUS-GE with ES in terms of (1) symptom recurrence and need for re-intervention, (2) technical success (proper stent positioning as determined via endoscopy and fluoroscopy), (3) clinical success (ability to tolerate oral intake without vomiting), and (4) procedure-related adverse events (AEs). Methods Multicenter retrospective study of all consecutive patients who underwent either EUS-GE at four centers between 2013 and 2015 or ES at one center between 2008 and 2010. Results A total of 82 patients (mean age 66-years ± 13.5 and 40.2% female) were identified: 30 in EUS-GE and 52 in ES. Technical and clinical success was not significantly different: 86.7% EUS-GE versus 94.2% ES ( p  = 0.2) and 83.3% EUS-GE versus 67.3% ES ( p  = 0.12), respectively. Symptom recurrence and need for re-intervention, however, was significantly lower in the EUS-GE group (4.0 vs. 28.6%, ( p  = 0.015). Post-procedure mean length of hospitalization was comparable at 11.3 days ± 6.6 for EUS-GE versus 9.5 days ± 8.3 for ES ( p  = 0.3). Rates and severity of AEs (as per the ASGE lexicon) were also similar (16.7 vs. 11.5%, p  = 0.5). On multivariable analysis, ES was independently associated with need for re-intervention (OR 12.8, p  = 0.027). Conclusion EUS-GE may be ideal for malignant GOO with comparable effectiveness and safety to ES while being associated with fewer symptom recurrence and requirements for re-intervention.
Endoscopic placement of covered versus uncovered self-expandable metal stents for palliation of malignant gastric outlet obstruction
ObjectiveStenting is an established endoscopic therapy for malignant gastric outlet obstruction (mGOO). The choice of stent (covered vs uncovered) has been examined in prior randomised studies without clear results.DesignIn a multicentre randomised prospective study, we compared covered (CSEMS) with uncovered self-expandable metal stents (UCSEMS) in patients with mGOO; main outcomes were stent dysfunction and patient survival, with subgroup analyses of patients with extrinsic and intrinsic tumours.ResultsOverall survival was poor with no difference between groups (probability at 3 months 49.7% for covered vs 48.4% for uncovered stents; log-rank for overall survival p=0.26). Within that setting of short survival, the proportion of stent dysfunction was significantly higher for uncovered stents (35.2% vs 23.4%, p=0.01) with significantly shorter time to stent dysfunction. This was mainly relevant for patients with extrinsic tumours (stent dysfunction rates for uncovered stents 35.6% vs 17.5%, p<0.01). Subgrouping was also relevant with respect to tumour ingrowth (lower with covered stents for intrinsic tumours; 1.6% vs 27.7%, p<0.01) and stent migration (higher with covered stents for extrinsic tumours: 15.3% vs 2.5%, p<0.01).ConclusionsDue to poor patient survival, minor differences between covered and uncovered stents may be less relevant even if statistically significant; however, subgroup analysis would suggest to use covered stents for intrinsic and uncovered stents for extrinsic malignancies.
EUS-guided gastroenterostomy versus enteral stent placement for palliation of malignant gastric outlet obstruction
BackgroundEUS-guided gastroenterostomy (EUS-GE) is a novel procedure for palliation of malignant gastric outlet obstruction (GOO); however, data comparing EUS-GE to enteral stent placement are limited. We aimed to compare clinical outcomes between EUS-GE and enteral stent placement in the palliation of malignant GOO.MethodsRetrospective analysis of a prospectively collected database on patients who underwent EUS-GE or enteral stent placement for palliation of malignant GOO from 2014 to 2017 was conducted. Primary outcome was the rate of stent failure requiring repeat intervention. Secondary outcomes included technical and clinical success, time to repeat intervention, length of hospital stay, and adverse events.ResultsA total of 100 consecutive patients (mean age 65.9 ± 11.9 years, 44.0% female) were identified, of which 78 underwent enteral stent placement, and 22 underwent EUS-GE. Rate of stent failure requiring repeat intervention was higher in the enteral stent group than the EUS-GE group (32.0% vs. 8.3%, p = 0.021). Technical success was achieved in 100% in both groups. Higher initial clinical success was attained in the EUS-GE group than the enteral stent group (95.8% vs. 76.3%, p = 0.042). Mean length of hospital stay following stent placement was similar between groups (p = 0.821). The enteral stent group trended towards increased adverse events (40.2% vs. 20.8%, p = 0.098). Kaplan–Meier analysis showed decreased stent function in the enteral stent group (p = 0.013).ConclusionCompared to enteral stent placement, EUS-GE has a higher rate of initial clinical success and lower rate of stent failure requiring repeat intervention. EUS-GE may be offered for selected patients with malignant GOO in centers with extensive experience.
The Effects of Pre-Operative Enteral Nutrition from Nasal Feeding Tubes on Gastric Outlet Obstruction
We examined gastric outlet obstruction (GOO) patients who received two weeks of strengthening pre-operative enteral nutrition therapy (pre-EN) through a nasal–jejenal feeding tube placed under a gastroscope to evaluate the feasibility and potential benefit of pre-EN compared to parenteral nutrition (PN). In this study, 68 patients confirmed to have GOO with upper-gastrointestinal contrast and who accepted the operation were randomized into an EN group and a PN group. The differences in nutritional status, immune function, post-operative complications, weight of patients, first bowel sound and first flatus time, pull tube time, length of hospital stay (LOH), and cost of hospitalization between pre-operation and post-operation were all recorded. Statistical analyses were performed using the chi square test and t-test; statistical significance was defined as p < 0.05. The success rate of the placement was 91.18% (three out of 31 cases). After pre-EN, the levels of weight, albumin (ALB), prealbumin (PA), and transferrin (TNF) in the EN group were significantly increased by pre-operation day compared to admission day, but were not significantly increased in the PN group; the weights in the EN group were significantly increased compared to the PN group by pre-operation day and day of discharge; total protein (TP), ALB, PA, and TNF of the EN group were significantly increased compared to the PN group on pre-operation and post-operative days one and three. The levels of CD3+, CD4+/CD8+, IgA, and IgM in the EN group were higher than those of the PN group at pre-operation and post-operation; the EN group had a significantly lower incidence of poor wound healing, peritoneal cavity infection, pneumonia, and a shorter first bowel sound time, first flatus time, and post-operation hospital stay than the PN group. Pre-EN through a nasal–jejunum feeding tube and placed under a gastroscope in GOO patients was safe, feasible, and beneficial to the nutrition status, immune function, and gastrointestinal function, and sped up recovery, while not increasing the cost of hospitalization.
Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents
Background Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. Methods In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. Results In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p  = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p  = 0.005). Karnofsky performance status ( p  = 0.04), no presence of ascites ( p  = 0.02), and insufficient (<30%) stent expansion ( p  = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length ( p  = 0.05) and chemotherapy ( p  = 0.03) were predictors of C-SEMS migration. Conclusions Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).
Vascular thoracic outlet syndrome
Objectives: To outline our experience with both arterial vascular thoracic outlet syndrome (ATOS) and venous TOS (VTOS). Methods: This was a retrospective review carried out at King Saud University Medical City, Riyadh, Saudi Arabia, from 1992-2022. All patients were diagnosed based on clinical presentation, imaging, and underwent surgical decompression solely via the supraclavicular approach. The median follow-up period was 18 months (range: 4-36 months). Results: A total of 90 limbs were diagnosed with vascular TOS in 69 patients. Females accounted for 69.6% of the patients and approximately 86.7% had ATOS. All patients were symptomatic and underwent plain thoracic inlet and cervical spine radiography, along with duplex scans in both rest and provocative positions. Total cervical rib resection was carried out in 60% of cases, while 2% had partial resection. First rib resection was carried out in 13.3% of cases and combined cervical and first rib resections were carried out in 23.3%. Vascular procedures were needed for arterial repair in 20% of cases, while venous repair were carried out in 2.2%. No recurrence or postoperative mortality had been reported. Post-operative complications were observed in 18.9% of cases. Conclusion: Careful patient selection and diagnosis using advanced, but less invasive radiological imaging coupled with adequate surgical treatment can improve the patient's outcome. Keywords: thoracic outlet syndrome, arterial thoracic outlet syndrome, venous thoracic outlet syndrome [phrase omitted]
Covered Metallic Stents With an Anti-Migration Design vs. Uncovered Stents for the Palliation of Malignant Gastric Outlet Obstruction: A Multicenter, Randomized Trial
Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer.