Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
2,565
result(s) for
"PEEK"
Sort by:
The Role of Polyether Ether Ketone (Peek) in Dentistry – A Review
by
Bathala, Lakshmana
,
Singh, Nibha
,
Rachuri, Narendra
in
Aesthetics
,
Benzophenones
,
Biological activity
2019
This study is aimed to review the applications of Polyether Ether Ketone (PEEK) in dentistry. The increased demand for aesthetics, legislation in some developed countries, few drawbacks with existing materials and clinicians shifting their paradigms towards metal free restorations led space for the metal-free restorations in today’s dental practice. An electronic literature search was conducted through Medline via PubMed, Wiley Online library, EBSCOhost, Science Direct, as well as the Google Scholar between January 2010 and March 2018 using the keywords: PEEK, modified PEEK, PEEK and Dental, advantages of PEEK, applications of PEEK in dentistry and PEEK Implants. A total of 103 articles were found in the literature search and out of these, 18 were not related to our study and hence were excluded. Finally, 85 articles were found to be relevant. PEEK has been explained for a number of applications in dental practice. The literature showed that the PEEK material has superior mechanical properties with different uses in various specialties of dentistry.
Journal Article
Surface Modifications of High-Performance Polymer Polyetheretherketone (PEEK) to Improve Its Biological Performance in Dentistry
by
Nalam, Prathima C.
,
Pidhatika, Bidhari
,
Ardhani, Retno
in
Adhesive strength
,
Adhesives
,
Antibacterial agents
2022
This comprehensive review focuses on polyetheretherketone (PEEK), a synthetic thermoplastic polymer, for applications in dentistry. As a high-performance polymer, PEEK is intrinsically robust yet biocompatible, making it an ideal substitute for titanium—the current gold standard in dentistry. PEEK, however, is also inert due to its low surface energy and brings challenges when employed in dentistry. Inert PEEK often falls short of achieving a few critical requirements of clinical dental materials, such as adhesiveness, osseoconductivity, antibacterial properties, and resistance to tribocorrosion. This study aims to review these properties and explore the various surface modification strategies that enhance the performance of PEEK. Literatures searches were conducted on Google Scholar, Research Gate, and PubMed databases using PEEK, polyetheretherketone, osseointegration of PEEK, PEEK in dentistry, tribology of PEEK, surface modifications, dental applications, bonding strength, surface topography, adhesive in dentistry, and dental implant as keywords. Literature on the topics of surface modification to increase adhesiveness, tribology, and osseointegration of PEEK were included in the review. The unavailability of full texts was considered when excluding literature. Surface modifications via chemical strategies (such as sulfonation, plasma treatment, UV treatment, surface coating, surface polymerization, etc.) and/or physical approaches (such as sandblasting, laser treatment, accelerated neutral atom beam, layer-by-layer assembly, particle leaching, etc.) discussed in the literature are summarized and compared. Further, approaches such as the incorporation of bioactive materials, e.g., osteogenic agents, antibacterial agents, etc., to enhance the abovementioned desired properties are explored. This review presents surface modification as a critical and essential approach to enhance the biological performance of PEEK in dentistry by retaining its mechanical robustness.
Journal Article
Effects of Titanium Implant Surface Topology on Bone Cell Attachment and Proliferation in vitro
by
Levin, Michael
,
Jain, Himanshu
,
Spiro, Robert
in
cell adhesion and proliferation
,
Comparative analysis
,
Corrosion and anti-corrosives
2022
Titanium is commonly used for implants because of its corrosion resistance and osseointegration capability. It is well known that surface topology affects the response of bone tissue towards implants. In vivo studies have shown that in weeks or months, bone tissue bonds more efficiently to titanium implants with rough surfaces compared to smooth surfaces. In addition, stimulating early endosseous integration increases the long-term stability of bone-implants and hence their clinical outcome. Here, we evaluated the response of human MG-63 osteoblast-like cells to flat and solid, compared to rough and porous surface topologies in vitro 1-6 days post seeding. We compared the morphology, proliferation, and attachment of cells onto three smooth surfaces: tissue culture (TC) plastic or microscope cover glasses, machined polyether-ether-ketone (PEEK), and machined solid titanium, to cells on a highly porous (average R
22.94 μm) plasma-sprayed titanium surface (composite Ti-PEEK spine implants).
We used immuno-fluorescence (IF) and scanning electron microscopy (SEM), as well as Live/Dead and WST-1 cell proliferation assays.
SEM analyses confirmed the rough topology of the titanium implant surface, compared to the smooth surface of PEEK, solid titanium, TC plastic and cover glasses. In addition, SEM analyses revealed that MG-63 cells seeded onto smooth surfaces (solid titanium, PEEK) adopted a flat, planar morphology, while cells on the rough titanium surface adopted an elongated morphology with numerous filopodial and lamellipodial extensions interacting with the substrate. Finally, IF analyses of focal adhesions (vinculin, focal adhesion kinase), as well as proliferation assays indicate that MG-63 cells adhere less and proliferate at a slower rate on the rough than on a smooth titanium surface.
These observations suggest that bone-forming osteoblasts adhere less strongly and proliferate slower on rough compared to smooth titanium surfaces, likely promoting cell differentiation, which is in agreement with other porous implant materials.
Journal Article
Characterization of New PEEK/HA Composites with 3D HA Network Fabricated by Extrusion Freeforming
by
Moshrefi-Torbati, Mohamed
,
Yang, Shoufeng
,
Oreffo, Richard
in
Additive manufacturing
,
additive manufacturing (AM)
,
bioactive PEEK/HA composite
2016
Addition of bioactive materials such as calcium phosphates or Bioglass, and incorporation of porosity into polyetheretherketone (PEEK) has been identified as an effective approach to improve bone-implant interfaces and osseointegration of PEEK-based devices. In this paper, a novel production technique based on the extrusion freeforming method is proposed that yields a bioactive PEEK/hydroxyapatite (PEEK/HA) composite with a unique configuration in which the bioactive phase (i.e., HA) distribution is computer-controlled within a PEEK matrix. The 100% interconnectivity of the HA network in the biocomposite confers an advantage over alternative forms of other microstructural configurations. Moreover, the technique can be employed to produce porous PEEK structures with controlled pore size and distribution, facilitating greater cellular infiltration and biological integration of PEEK composites within patient tissue. The results of unconfined, uniaxial compressive tests on these new PEEK/HA biocomposites with 40% HA under both static and cyclic mode were promising, showing the composites possess yield and compressive strength within the range of human cortical bone suitable for load bearing applications. In addition, preliminary evidence supporting initial biological safety of the new technique developed is demonstrated in this paper. Sufficient cell attachment, sustained viability in contact with the sample over a seven-day period, evidence of cell bridging and matrix deposition all confirmed excellent biocompatibility.
Journal Article
Surface Modification of Carbon Fibers by Grafting PEEK-NH2 for Improving Interfacial Adhesion with Polyetheretherketone
2019
Due to the non-polar nature and low wettability of carbon fibers (CFs), the interfacial adhesion between CFs and the polyetheretherketone (PEEK) matrix is poor, and this has negative effects on the mechanical properties of CF/PEEK composites. In this work, we established a modification method to improve the interface between CFs and PEEK based chemical grafting of aminated polyetheretherketone (PEEK-NH2) on CFs to create an interfacial layer which has competency with the PEEK matrix. The changed chemical composition, surface morphology, surface energy, and interlaminar shear strength were investigated. After grafting, the interlaminar shear strength (ILSS) was improved by 33.4% due to the covalent bonds in the interface region, as well as having good compatibility between the interface modifier and PEEK. Finally, Dynamic Mechanical Analysis (DMA) and Scanning Electron Microscopy (SEM) observation also confirmed that the properties of the modified CF/PEEK composites interface were enhanced. This work is, therefore, a beneficial approach towards enhancing the mechanical properties of thermoplastic composites by controlling the interface between CFs and the PEEK matrix.
Journal Article
Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading
by
Konschake, Marko
,
Schmid, Rene
,
Nydegger, Thomas
in
Bone cancer
,
Bone mineral density
,
Cadavers
2018
PurposePedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws.MethodsIn the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm3 ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm3 ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from − 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion (“screw toggling”) within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles.ResultsThe nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard titanium screws (3701 ± 1228 vs. 3751 ± 1614 load cycles, p = 0.89). PMMA cement augmentation of CF/PEEK pedicle screws furthermore significantly increased the mean number of load cycles until loosening by 1.63-fold (5100 ± 1933 in augmented vs. 3130 ± 2132 in nonaugmented CF/PEEK screws, p = 0.015). In addition, angular screw motion assessed by stress fluoroscopy was significantly smaller in augmented than in nonaugmented CF/PEEK screws before as well as after failure.ConclusionsUsing nonmetallic CF/PEEK instead of standard titanium as pedicle screw material did not affect screw loosening in the chosen test setup, whereas cement augmentation enhanced screw anchorage of CF/PEEK screws. While comparable to titanium screws in terms of screw loosening, radiolucent CF/PEEK pedicle screws offer the significant advantage of not interfering with postoperative imaging and radiotherapy.Graphical abstractThese slides can be retrieved under Electronic Supplementary Material.
Journal Article
The Direct 3D Printing of Functional PEEK/Hydroxyapatite Composites via a Fused Filament Fabrication Approach
2021
The manufacture of polyetheretherketone/hydroxyapatite (PEEK/HA) composites is seen as a viable approach to help enhance direct bone apposition in orthopaedic implants. A range of methods have been used to produce composites, including Selective Laser Sintering and injection moulding. Such techniques have drawbacks and lack flexibility to manufacture complex, custom-designed implants. 3D printing gets around many of the restraints and provides new opportunities for innovative solutions that are structurally suited to meet the needs of the patient. This work reports the direct 3D printing of extruded PEEK/HA composite filaments via a Fused Filament Fabrication (FFF) approach. In this work samples are 3D printed by a custom modified commercial printer Ultimaker 2+ (UM2+). SEM-EDX and µCT analyses show that HA particles are evenly distributed throughout the bulk and across the surface of the native 3D printed samples, with XRD highlighting up to 50% crystallinity and crystalline domains clearly observed in SEM and HR-TEM analyses. This highlights the favourable temperature conditions during 3D printing. The yield stress and ultimate tensile strength obtained for all the samples are comparable to human femoral cortical bone. The results show how FFF 3D printing of PEEK/HA composites up to 30 wt% HA can be achieved.
Journal Article
Additive Manufacturing of Polyether Ether Ketone (PEEK) for Space Applications: A Nanosat Polymeric Structure
2020
Recent improvements in additive layer manufacturing (ALM) have provided new designs of geometrically complex structures with lighter materials and low processing costs. The use of additive manufacturing in spacecraft production is opening up many new possibilities in both design and fabrication, allowing for the reduction of the weight of the structure subsystems. In this aim, polymeric ALM structures can become a choice, in terms of lightweight and demisability, as far as good thermomechanical properties. Moreover, provided that fused-deposition modeling (FDM) is used, nanosats and other structures could be easily produced in space. However, the choice of the material is a crucial step of the process, as the final performance of the printed parts is strongly dependent on three pillars: design, material, and printing process. As a high-performance technopolymer, polyether ether ketone (PEEK) has been adopted to fabricate parts via ALM; however, the space compatibility of 3D-printed parts remains not demonstrated. This work aimed to realize a nanosat polymeric structure via FDM, including all the phases of the development process: thermomechanical design, raw material selection, printing process tuning, and manufacturing of a proof of concept of a technological model. The design phase includes the application of topology optimization to maximize mass saving and take full advantage of the ALM capability. 3D-printed parts were characterized via thermomechanical tests, outgassing tests of 3D-printed parts are reported confirming the outstanding performance of polyether ether ketone and its potential as a material for structural space application.
Journal Article
Use of scaffolds based on polyetheretherketone tubular implant in the treatment of a gunshot multifragmentary fracture of the proximal part of the shoulder with a bone defect: a case report
2024
Background
In connection with the war in Ukraine and the use of modern high-energy weapons by the enemy, the nature of injuries have changed. These changes require improvement of approaches to the treatment of patients with gunshot and mine-explosive bone defects.
Case presentation
We present the case of treatment of a 28-year-old Ukranian man with a gunshot multifragmentary fracture of the proximal humerus with a bone defect using three-dimensional printing of a polyetheretherketone frame (scaffold) for alloplastic material. The analysis of this case expands the possibilities of using three-dimensional printing technologies of polyetheretherketone scaffolds in the treatment of significant bone defects.
Conclusion
Modern military trauma requires individualized treatment for each patient. The use of individual polyetheretherketone scaffolds in the treatment of a gunshot multifragmentary fracture with a bone defect has a positive clinical effect.
Journal Article
The dosimetric impact of stabilizing spinal implants in radiotherapy treatment planning with protons and photons: standard titanium alloy vs. radiolucent carbon‐fiber‐reinforced PEEK systems
2020
Background Throughout the last years, carbon‐fibre‐reinforced PEEK (CFP) pedicle screw systems were introduced to replace standard titanium alloy (Ti) implants for spinal instrumentation, promising improved radiotherapy (RT) treatment planning accuracy. We compared the dosimetric impact of both implants for intensity modulated proton (IMPT) and volumetric arc photon therapy (VMAT), with the focus on uncertainties in Hounsfield unit assignment of titanium alloy. Methods Retrospective planning was performed on CT data of five patients with Ti and five with CFP implants. Carbon‐fibre‐reinforced PEEK systems comprised radiolucent pedicle screws with thin titanium‐coated regions and titanium tulips. For each patient, one IMPT and one VMAT plan were generated with a nominal relative stopping power (SP) (IMPT) and electron density (ρ) (VMAT) and recalculated onto the identical CT with increased and decreased SP or ρ by ±6% for the titanium components. Results Recalculated VMAT dose distributions hardly deviated from the nominal plans for both screw types. IMPT plans resulted in more heterogeneous target coverage, measured by the standard deviation σ inside the target, which increased on average by 7.6 ± 2.3% (Ti) vs 3.4 ± 1.2% (CFP). Larger SPs lead to lower target minimum doses, lower SPs to higher dose maxima, with a more pronounced effect for Ti screws. Conclusions While VMAT plans showed no relevant difference in dosimetric quality between both screw types, IMPT plans demonstrated the benefit of CFP screws through a smaller dosimetric impact of CT‐value uncertainties compared to Ti. Reducing metal components in implants will therefore improve dose calculation accuracy and lower the risk for tumor underdosage.
Journal Article