Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
1,789 result(s) for "Position change"
Sort by:
A Comparative Study of 2-Hour Interface Pressure in Different Angles of Laterally Inclined, Supine, and Fowler’s Position
Insufficient research exists for position change intervals to eradicate pressure ulcers. We tried to provide evidence for the position change interval by comparing peak pressure, risk area ratio, and the time to reach 30 mmHg and 60 mmHg, and presented this in detail, according to the angle in the three positions. The study conducted RCTs on a total of 64 healthy adults. For two hours, interface pressure measurements were compared with 30° and 90° tilting at the inclined, 0° and 45° head-of-bed (HOB) elevation at the supine, and 30° and 45° HOB elevation at the Fowler’s position. The peak pressure on 30° tilting remained less than 60 mmHg for 2 h, unlike 90° tilting. To reach 60 mmHg took 78.18 min at 30° tilting, within 30 min at the 30° supine, 30° and 45° at the Fowler’s position, and 39.55 min at 0° supine. The pressure difference according to the angles was only significant at 30° and 90° tilting, with no difference in the other groups. To prevent pressure ulcers, position changes are required every 2 h in the 30° tilting position, every 1.5 to 2 h at 0° supine, and at least every 1.5 h for all the other positions.
Evolution of the Global Agricultural Trade Network and Policy Implications for China
Global agricultural trade plays an essential role in balancing supply and demand regarding agricultural products worldwide. Based on complex network theory, two types of agricultural trade networks weighted by the physical quantity and monetary value were built. In both networks, eight groups of agricultural products showed diverse variation in time and space. During 1986 to 2016, the total physical trade increased by 2.55 times with a gradual growth process, and total monetary value increased 1.98 times with fluctuation. The cumulative distribution of node degree and strength followed power-law distribution. Scale expansion and structure complexity of both networks reflected heterogeneity between nodes and the trend of agricultural economic globalization. Meeting demand and seeking greater returns are the main drivers of global agricultural trade development. Mainly developed countries occupied the important positions in the global agricultural trade network, but some emerging economies such as China, Brazil, and India became important sources of demand and supply. China not only needs to fully use international resources to meet demand for agricultural products, but also needs to ensure its own food security through multiple countermeasures.
Does right lateral decubitus position change retroperitoneal oblique corridor? A radiographic evaluation from L1 to L5
Purpose To determine if the retroperitoneal oblique corridor will be affected by right lateral decubitus position. Methods Forty volunteers were randomly enrolled and MRI scan was performed from L1 to L5 in supine and right lateral decubitus positions, respectively. In images across the center of each disc, O was defined as the center of a disc and A (supine) or A′ (right lateral decubitus) was located in left lateral border of the aorta or the iliac artery; B (supine) or B′ (right lateral decubitus) was on the anterior medial border of the psoas. The distance of AB and A′B′ (Recorded as A-Ps and A-Pr, respectively) at each level was recorded and compared to each other. The relationships between A-Pr, sex, BMI and relative psoas cross-sectional area (PCSA) at each level were also evaluated. Results A-Pr was significantly smaller than A-Ps at L1/2, L2/3 and L3/4 (All p  < 0.05); there was no significantly difference of A-Pr between all levels ( p  = 0.105), but L1/2 seemed to be larger than L3/4, followed by L2/3 and L4/5; A-Pr at each level was not affected by sex (All p  > 0.05); linear relationships were found between A-Pr, BMI and PCSA at L1/2 and L3/4. Conclusions ROC at L1/2, L2/3 and L3/4 will significantly decrease from supine to right lateral decubitus position and the reason may be due to the relaxed psoas deformation. Using MRI images in supine position for pre-operatively ROC evaluation is not accurate. Spine surgeon should also be more cautious when OLIF is performed at L4/5 where ROC is the smallest. Patients from Asia and those with strong psoas major at L1/2 and L3/4 are also associated with relatively narrow ROC.
Long-term outcomes of laparoscopic Extralevator Abdominoperineal excision with modified position change for low rectal Cancer treatment
Background Extralevator abdominoperineal excision (ELAPE) has been recommended for treating low rectal cancer due to its potential advantages in improving surgical safety and oncologic outcomes as compared to conventional abdominoperineal excision (APE). In ELAPE, however, whether the benefits of intraoperative position change to a prone jackknife position outweighs the associated risks remains controversial. This study is to introduce a modified position change in laparoscopic ELAPE and evaluate its feasibility, safety and the long-term therapeutic outcomes. Methods Medical records of 56 consecutive patients with low rectal cancer underwent laparoscopic ELAPE from November 2013 to September 2016 were retrospectively studied. In the operation, a perineal dissection in prone jackknife position was firstly performed and the laparoscopic procedure was then conducted in supine position. Patient characteristics, intraoperative and postoperative outcomes, pathologic and 5-year oncologic outcomes were analyzed. Results The mean operation time was 213.5 ± 29.4 min and the mean intraoperative blood loss was 152.7 ± 125.2 ml. All the tumors were totally resected, without intraoperative perforation, conversion to open surgery, postoperative 30-day death, and perioperative complications. All the patients achieved pelvic peritoneum reconstruction without the usage of biological mesh. During the follow-up period, perineal hernia was observed in 1 patient, impaired sexual function in 1 patient, and parastomal hernias in 3 patients. The local recurrence rate was 1.9% and distant metastasis was noted in 12 patients. The 5-year overall survival rate was 76.4% and the 5-year disease-free survival rate was 70.9%. Conclusions Laparoscopic ELAPE with modified position change is a simplified, safe and feasible procedure with favorable outcomes. The pelvic peritoneum can be directly closed by the laparoscopic approach without the application of biological mesh.
Effect of dynamic position changes during colonoscope withdrawal: a meta-analysis of randomized controlled trials
BackgroundColonoscopies are considered to be the primary screening test and gold standard test for colorectal cancer. Position changes during colonoscope withdrawal are believed to be associated with an increased adenoma detection rate (ADR) and polyp detection rate (PDR). However, previous results conflicted, and this study aimed to elucidate the effectiveness of dynamic position changes during colonoscope withdrawal.MethodsThe relevant publications were identified by searching the medical databases. The primary outcomes were the ADR and PDR, which were pooled and analyzed. The secondary outcome was the withdrawal time. The studies that supplied the ADR and PDR for different segments of the colon were separated into subgroup analyses.ResultsFive randomized controlled trials were eligible for analysis. The total ADR was higher with dynamic position changes than with a static position (odds ratio, [OR] 1.34; 95% confidence interval [CI] 1.13–1.59; p < 0.001), with low evidence of between-study heterogeneity (I2 = 0%). Although the total PDR was slightly higher with dynamic position changes than with a static position (OR 1.23; 95% CI 0.88–1.73), there difference was not statistically significant (p = 0.22). The withdrawal time was only increased by 0.47 min (95% CI − 0.11 to 1.06) with dynamic position changes, without statistical significance (p = 0.11). The subgroup analysis showed that the ADR and PDR for the transverse colon were higher with dynamic position changes, with pooled estimates of ADR (OR 1.72; 95% CI 1.02–2.88; p = 0.04) and PDR (OR 1.79; 95% CI 1.08–2.96; p = 0.02).ConclusionDynamic position changes during colonoscope withdrawal increased the total ADR; however, no obvious increase was found in the total PDR. The withdrawal time was not significantly prolonged with dynamic position changes. Subgroup analysis showed that the ADR and PDR in the transverse colon were obviously improved with dynamic position changes.
Repetitive Position Change Improves Gastric Cleanliness for Magnetically Controlled Capsule Gastroscopy
Background and AimsGood gastric preparation is essential for magnetically controlled capsule gastroscopy (MCCG) examination. This study aims to determine if repetitive position change after dimethicone premedication could further improve gastric cleanliness for MCCG.MethodsConsecutive patients referred for MCCG in our center from May 7 to May 31, 2018 were prospectively enrolled and randomized to undergo repetitive position change for 15 min (position change group) or not (conventional group) after ingesting dimethicone. Primary outcome was gastric cleanliness score and secondary outcomes were detection rate of positive findings, number of lesions per patient, gastric examination time, and safety of MCCG.ResultsTotals of 43 and 40 were included in the position change and conventional groups, respectively. Gastric cleanliness score in the position change group was significantly higher than in the conventional group (21.2 ± 1.0 vs. 18.6 ± 2.0, P  < 0.001), as was the proportion of acceptable gastric cleanliness (gastric cleanliness score ≥ 18) (100% vs. 72.5%, P  < 0.001). There was no statistical difference in detection rate of positive findings between the two groups (27.9% vs. 27.5%, P  = 0.97). In the position change group, the gastric examination time was significantly reduced (13.2 ± 4.0 vs. 15.3 ± 5.1, P = 0.043). No adverse events were observed.ConclusionsRepetitive position change after dimethicone premedication significantly improves gastric cleanliness for MCCG examination.Clinical Trial Registration ClinicalTrials.gov, ID: NCT03514966.
Usefulness of Body Position Change during Local Ablation Therapies for the High-Risk Location Hepatocellular Carcinoma
Local ablation therapies are important treatment options for early-stage hepatocellular carcinoma (HCC). Various techniques have been used to perform these therapies efficiently and safely. However, few reports have discussed the usefulness of body position change (BPC). This study aimed to investigate the usefulness of BPC during local ablation therapies in patients with HCC. We evaluated 283 HCC nodules that underwent local ablation therapy. These nodules were categorized into high- or low-risk locations on the basis of their proximity to large vessels, adjacent extrahepatic organs, or poor visibility under ultrasound (US) guidance. The technical success rates, procedure time, and prognosis were evaluated. In this study, 176 (62%) nodules were classified in the high-risk location group. The high-risk location group was treated with techniques such as BPC, artificial pleural fluid, artificial ascites, fusion imaging, and contrast-enhanced US more frequently than the low-risk location group. The technical success rates were 96% and 95% for the high- and low-risk location groups, respectively. Within the high-risk location group, those without BPC had a lower success rate than those with BPC (91% vs. 99%, p = 0.015). Notably, BPC emerged as the sole contributing factor to the technical success rate in the high-risk location group (OR = 10, 95% CI 1.2–86, p = 0.034). In contrast, no differences were found in the procedure time, local tumor progression rates, intrahepatic distant recurrence rates, and overall survival between the groups with and without BPC in the high-risk location group. In conclusion, BPC during local ablation therapy in patients with HCC in high-risk locations was safe and efficient. The body position should be adjusted for HCC in high-risk locations to maintain good US visibility and ensure a safe puncture route in patients undergoing local ablation therapies.
Condylar volume and positional changes following a bilateral sagittal split ramus osteotomy in skeletal class II and III malocclusions
Background Mandibular condyle remodeling and displacement are post-orthognathic surgery concerns that can potentially lead to occlusal issues after bilateral sagittal split ramus osteotomy. This retrospective study examined the relationship between condylar volume changes and position alterations after surgery in patients with skeletal class II and III malocclusions using cone-beam CT. Methods The study included 16 patients (6 with Class II malocclusion, 10 with Class III malocclusion) who underwent bilateral sagittal split ramus osteotomy at Chonnam National University Hospital. Cone-beam CT data were collected at three specific time points: before surgery, immediately after surgery, and approximately 6 months post-surgery. Mandibular movement was measured using InVivoDental 5.4.6. ITK-SNAP 3.8.0 was used to assessed condylar volume changes post-surgery. Condyle positions were evaluated in four parts with RadiAnt DICOM Viewer 4.6.9. Statistical analyses were performed using the SPSS version 23. Results Considering both Class II and III malocclusion, a 2.91% volume reduction was noted immediately and at 6 months after surgery. Both Class II and III cases demonstrated a decrease in superior joint space by -0.59 mm and medial joint space by -1.09 mm. No significant correlation was found between this process and condylar volume change. Conclusions The mandibular condyle volume decreased, and superior-medial movement of the condyle was detected in patients with Class II and III malocclusion immediately and at 6 months after surgery with no volume-position correlation.
Unsedated or On-Demand Minimally Sedated Water-Aided Outpatient Colonoscopy in Colorectal Cancer Screening and Surveillance: A Step Forward or Backward? Experience from Daily Practice in a Regional (Nonacademic) Hospital
Background: By using optimal insertion techniques with water infusion and dynamic position changes, pain during colonoscopy is greatly reduced and the procedures can usually be performed without sedation. We investigated whether the excellent results with water-aided colonoscopy reported by experts are reproducible in daily practice in a regional hospital. Methods: During the year 2023, 500 consecutive outpatients 50–75 years old presenting for colorectal cancer screening and surveillance could choose between unsedated or on-demand minimally sedated colonoscopy, moderate sedation with midazolam, or deep sedation with propofol. A total of 57% opted for unsedated colonoscopy, and of those patients, 250 consecutive patients were included. The primary outcome was the feasibility of the procedure. Cecal intubation rate (CIR), pain scores, use of midazolam, and willingness to repeat future procedures in the same way were registered periprocedural. Additional outcomes were cecal intubation time (CIT), detection rate of lesions, polyp resection rate, rate of adequate bowel preparation, and volume of water aspirated during insertion. Results: 250 consecutive sedation-free or on-demand minimally sedated water-based colonoscopies were analyzed. The CIR was 98%. A total of 96.5% completed without sedation and 5% of the procedures were perceived as moderately painful, but none had severe pain. The willingness to repeat was 97%. The mean CIT was 8.2 min. Conclusions: Using water-aided insertion techniques, comfortable sedation-free, or on-demand minimally sedated colonoscopy in daily practice in a regional hospital is feasible in the vast majority of patients presenting for colorectal cancer screening and surveillance, and the willingness to repeat is very high.
Changes in nail position and antirotation blade angles on the risk of femoral head varus in PFNA fixed patients: a clinical review and comprehensive biomechanical research
Background Femoral head varus triggers poor clinical prognosis in intertrochanteric fracture patients with proximal femoral nail antirotation (PFNA) fixation. Studies present that changes in nail position and screw insertion angles will affect fixation stability, but the biomechanical significance of these factors on the risk of femoral head varus has yet to be identified in PFNA fixed patients. Methods Clinical data in PFNA fixed intertrochanteric fracture patients have been reviewed, the relative position of intermedullary nail has been judged in the instant postoperative lateral radiography. Regression analyses have been performed to identify the effect of this factor on femoral head varus. Corresponding biomechanical mechanism has been identified by numerical mechanical simulations. Results A clinical review revealed that ventral side nail insertion can trigger higher risk of femoral head varus, corresponding numerical mechanical simulations also recorded poor fixation stability in models with ventral side nail insertion, and changes in the trajectory of anti-rotation blade will not obviously affect this tendency. Conclusions Ventral side insertion of intramedullary nail can trigger higher risk of femoral head varus in PFNA fixed patients by deteriorating the instant postoperative biomechanical environment, and changes in blade trajectory cannot change this tendency biomechanically. Therefore, this nail position should be adjusted to optimize patients’ prognosis.