Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
14,902
result(s) for
"Prosthesis Implantation"
Sort by:
Transcatheter Valve Replacement in Severe Tricuspid Regurgitation
2025
Severe tricuspid regurgitation is associated with disabling symptoms and an increased risk of death. Data regarding outcomes after percutaneous transcatheter tricuspid-valve replacement are needed.
In this international, multicenter trial, we randomly assigned 400 patients with severe symptomatic tricuspid regurgitation in a 2:1 ratio to undergo either transcatheter tricuspid-valve replacement and medical therapy (valve-replacement group) or medical therapy alone (control group). The hierarchical composite primary outcome was death from any cause, implantation of a right ventricular assist device or heart transplantation, postindex tricuspid-valve intervention, hospitalization for heart failure, an improvement of at least 10 points in the score on the Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS), an improvement of at least one New York Heart Association (NYHA) functional class, and an improvement of at least 30 m on the 6-minute walk distance. A win ratio was calculated for the primary outcome by comparing all possible patient pairs, starting with the first event in the hierarchy.
A total of 267 patients were assigned to the valve-replacement group and 133 to the control group. At 1 year, the win ratio favoring valve replacement was 2.02 (95% confidence interval [CI], 1.56 to 2.62; P<0.001). In comparisons of patient pairs, those in the valve-replacement group had more wins than the control group with respect to death from any cause (14.8% vs. 12.5%), postindex tricuspid-valve intervention (3.2% vs. 0.6%), and improvement in the KCCQ-OS score (23.1% vs. 6.0%), NYHA class (10.2% vs. 0.8%), and 6-minute walk distance (1.1% vs. 0.9%). The valve-replacement group had fewer wins than the control group with respect to the annualized rate of hospitalization for heart failure (9.7% vs. 10.0%). Severe bleeding occurred in 15.4% of the valve-replacement group and in 5.3% of the control group (P = 0.003); new permanent pacemakers were implanted in 17.4% and 2.3%, respectively (P<0.001).
For patients with severe tricuspid regurgitation, transcatheter tricuspid-valve replacement was superior to medical therapy alone for the primary composite outcome, driven primarily by improvements in symptoms and quality of life. (Funded by Edwards Lifesciences; TRISCEND II ClinicalTrials.gov number, NCT04482062.).
Journal Article
Transcatheter or Surgical Treatment of Aortic-Valve Stenosis
by
Eitel, Ingo
,
Hagendorff, Andreas
,
Walther, Thomas
in
Aged
,
Aortic stenosis
,
Aortic Valve - surgery
2024
A randomized trial that enrolled patients with severe aortic stenosis at low or intermediate surgical risk showed that transcatheter aortic-valve implantation was noninferior to surgical aortic-valve replacement at 1 year.
Journal Article
Transcatheter Repair for Patients with Tricuspid Regurgitation
by
Whisenant, Brian
,
Schwartz, Jonathan G.
,
Price, Matthew J.
in
Aged
,
Cardiac Catheterization - adverse effects
,
Cardiac Catheterization - methods
2023
In a randomized trial, patients with tricuspid regurgitation who were treated with transcatheter edge-to-edge repair had more favorable clinical outcomes at 1 year than did patients who received medical therapy.
Journal Article
Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
by
Petrossian, George
,
Gleason, Thomas G
,
Sorajja, Paul
in
Aged
,
Aortic stenosis
,
Aortic Valve - surgery
2019
In a randomized trial, 1468 patients with severe aortic stenosis who were at low risk for death with surgery were assigned to either transcatheter aortic-valve replacement with a self-expanding valve or surgical aortic-valve replacement. At 2 years, TAVR was noninferior to surgery with respect to death or disabling stroke.
Journal Article
Transcatheter Aortic-Valve Replacement in Low-Risk Patients at Five Years
by
Genereux, Philippe
,
Russo, Mark J.
,
Lu, Michael
in
Aortic stenosis
,
Aortic Valve - diagnostic imaging
,
Aortic Valve - surgery
2023
A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown.
We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years.
A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group.
Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).
Journal Article
Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
by
Hahn, Rebecca T
,
Brown, David L
,
Mack, Michael J
in
Aged
,
Aortic stenosis
,
Aortic Valve - surgery
2019
In a randomized trial, 1000 patients with severe aortic stenosis who were at low risk for death with surgery were assigned to undergo transcatheter aortic-valve replacement with a balloon-expandable valve or surgical aortic-valve replacement. At 1 year, the rate of death, stroke, or rehospitalization was significantly lower in the TAVR group.
Journal Article
Five-Year Follow-up after Transcatheter Repair of Secondary Mitral Regurgitation
by
Brieke, Andreas
,
Whisenant, Brian
,
Mishell, Jacob M.
in
Cardiac Catheterization - adverse effects
,
Cardiac Catheterization - methods
,
Cardiology
2023
Transcatheter repair of secondary mitral regurgitation was associated with a lower rate of hospitalization for heart failure and lower all-cause mortality than medical therapy at 5 years of follow-up.
Journal Article
Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
2016
In a randomized trial involving more than 2000 patients, transcatheter aortic-valve replacement was noninferior to surgical replacement in the primary end point of death from any cause or disabling stroke at 2 years.
Transcatheter aortic-valve replacement (TAVR) is a new therapy for patients with severe aortic stenosis who are not candidates for surgery
1
,
2
or who are at high risk for complications due to surgery.
3
,
4
The acceptance of the use of TAVR in high-risk patients was based on evidence from clinical trials
5
,
6
that used early-generation TAVR devices; these procedures were associated with considerable procedure-related complications.
7
–
9
Recently, increased operator experience and enhanced transcatheter valve systems have led to a worldwide trend to use TAVR in patients who are at low or intermediate risk.
10
–
12
This trend has been evaluated in small . . .
Journal Article
5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial
by
Makkar, Raj R
,
Hahn, Rebecca T
,
Brown, David L
in
Aged
,
Aged, 80 and over
,
Aortic Valve - surgery
2015
The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that mortality at 1 year, 2 years, and 3 years is much the same with transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) for high-risk patients with aortic stenosis. We report here the 5-year outcomes.
We did this randomised controlled trial at 25 hospitals, in Canada (two), Germany (one), and the USA (23). We used a computer-generated randomisation sequence to randomly assign high-risk patients with severe aortic stenosis to either SAVR or TAVR with a balloon-expandable bovine pericardial tissue valve by either a transfemoral or transapical approach. Patients and their treating physicians were not masked to treatment allocation. The primary outcome of the trial was all-cause mortality in the intention-to-treat population at 1 year, we present here predefined outcomes at 5 years. The study is registered with ClinicalTrials.gov, number NCT00530894.
We screened 3105 patients, of whom 699 were enrolled (348 assigned to TAVR, 351 assigned to SAVR). Overall mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 11·7%. At 5 years, risk of death was 67·8% in the TAVR group compared with 62·4% in the SAVR group (hazard ratio 1·04, 95% CI 0·86–1·24; p=0·76). We recorded no structural valve deterioration requiring surgical valve replacement in either group. Moderate or severe aortic regurgitation occurred in 40 (14%) of 280 patients in the TAVR group and two (1%) of 228 in the SAVR group (p<0·0001), and was associated with increased 5-year risk of mortality in the TAVR group (72·4% for moderate or severe aortic regurgitation vs 56·6% for those with mild aortic regurgitation or less; p=0·003).
Our findings show that TAVR as an alternative to surgery for patients with high surgical risk results in similar clinical outcomes.
Edwards Lifesciences.
Journal Article
Transcatheter Repair versus Mitral-Valve Surgery for Secondary Mitral Regurgitation
by
Walther, Thomas
,
Eitel, Ingo
,
Kelm, Malte
in
Aged
,
Cardiac Catheterization - adverse effects
,
Cardiology
2024
Current treatment recommendations for patients with heart failure and secondary mitral regurgitation include transcatheter edge-to-edge repair and mitral-valve surgery. Data from randomized trials comparing these therapies are lacking in this patient population.
In this noninferiority trial conducted in Germany, patients with heart failure and secondary mitral regurgitation who continued to have symptoms despite guideline-directed medical therapy were randomly assigned, in a 1:1 ratio, to undergo either transcatheter edge-to-edge repair (intervention group) or surgical mitral-valve repair or replacement (surgery group). The primary efficacy end point was a composite of death, hospitalization for heart failure, mitral-valve reintervention, implantation of an assist device, or stroke within 1 year after the procedure. The primary safety end point was a composite of major adverse events within 30 days after the procedure.
A total of 210 patients underwent randomization. The mean (±SD) age of the patients was 70.5±7.9 years, 39.9% were women, and the mean left ventricular ejection fraction was 43.0±11.7%. Within 1 year, at least one of the components of the primary efficacy end point occurred in 16 of the 96 patients with available data (16.7%) in the intervention group and in 20 of the 89 with available data (22.5%) in the surgery group (estimated mean difference, -6 percentage points; 95% confidence interval [CI], -17 to 6; P<0.001 for noninferiority). A primary safety end-point event occurred in 15 of the 101 patients with available data (14.9%) in the intervention group and in 51 of the 93 patients with available data (54.8%) in the surgery group (estimated mean difference, -40 percentage points; 95% CI, -51 to -27; P<0.001).
Among patients with heart failure and secondary mitral regurgitation, transcatheter edge-to-edge repair was noninferior to mitral-valve surgery with respect to a composite of death, rehospitalization for heart failure, stroke, reintervention, or implantation of an assist device in the left ventricle at 1 year. (Funded by Abbott Vascular; MATTERHORN ClinicalTrials.gov number, NCT02371512.).
Journal Article