Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
31,207 result(s) for "Protein Array Analysis"
Sort by:
Semi-wet peptide/protein array using supramolecular hydrogel
The protein microarray is a crucial biomaterial for the rapid and high-throughput assay of many biological events where proteins are involved. In contrast to the DNA microarray, it has not been sufficiently established because of protein instability under the conventional dry conditions. Here we report a novel semi-wet peptide/protein microarray using a supramolecular hydrogel composed of glycosylated amino acetate. The spontaneous gel-formation and amphiphilic properties of this supramolecular hydrogel have been applied to a new type of peptide/protein gel array that is compatible with enzyme assays. Aqueous cavities created in the gel matrix are a suitable semi-wet reaction medium for enzymes, whereas the hydrophobic domains of the fibre are useful as a unique site for monitoring the reaction. This array system overcomes several drawbacks of conventional protein chips, and thus can have potential applications in pharmaceutical research and diagnosis.
Reverse phase protein microarrays advance to use in clinical trials
Individualizing cancer therapy for molecular targeted inhibitors requires a new class of molecular profiling technology that can map the functional state of the cancer cell signal pathways containing the drug targets. Reverse phase protein microarrays (RPMA) are a technology platform designed for quantitative, multiplexed analysis of specific phosphorylated, cleaved, or total (phosphorylated and non-phosphorylated) forms of cellular proteins from a limited amount of sample. This class of microarray can be used to interrogate tissue samples, cells, serum, or body fluids. RPMA were previously a research tool; now this technology has graduated to use in research clinical trials with clinical grade sensitivity and precision. In this review we describe the application of RPMA for multiplexed signal pathway analysis in therapeutic monitoring, biomarker discovery, and evaluation of pharmaceutical targets, and conclude with a summary of the technical aspects of RPMA construction and analysis.
Technical Advances of the Recombinant Antibody Microarray Technology Platform for Clinical Immunoproteomics
In the quest for deciphering disease-associated biomarkers, high-performing tools for multiplexed protein expression profiling of crude clinical samples will be crucial. Affinity proteomics, mainly represented by antibody-based microarrays, have during recent years been established as a proteomic tool providing unique opportunities for parallelized protein expression profiling. But despite the progress, several main technical features and assay procedures remains to be (fully) resolved. Among these issues, the handling of protein microarray data, i.e. the biostatistics parts, is one of the key features to solve. In this study, we have therefore further optimized, validated, and standardized our in-house designed recombinant antibody microarray technology platform. To this end, we addressed the main remaining technical issues (e.g. antibody quality, array production, sample labelling, and selected assay conditions) and most importantly key biostatistics subjects (e.g. array data pre-processing and biomarker panel condensation). This represents one of the first antibody array studies in which these key biostatistics subjects have been studied in detail. Here, we thus present the next generation of the recombinant antibody microarray technology platform designed for clinical immunoproteomics.
Protein array profiling of circulating angiogenesis-related factors during bevacizumab containing treatment in metastatic colorectal cancer
Prolonged angiogenesis inhibition may improve treatment outcome in metastatic colorectal cancer (mCRC) patients. However, due to the complexity of the angiogenic pathways there is a lack of valid predictive biomarkers for anti-angiogenic agents. Here, we describe and optimize a procedure for simultaneous dynamic profiling of multiple angiogenesis related proteins in patient serum to explore associations with the response and acquired resistance to anti-angiogenic therapy. Patients (n=22) were selected from a clinical trial investigating maintenance treatment with bevacizumab alone after response to induction chemotherapy + bevacizumab in mCRC. Serum samples were analysed for 55 unique angiogenesis related proteins using a commercial proteome profiler array and a publicly available image analysis program for quantification. Samples were collected at baseline before induction treatment start, at start of maintenance treatment, and at end of treatment after tumour progression. For eight proteins, the antibody array signals were below detection range in all patient samples. None of the proteins showed levels at baseline or at start of maintenance with strong evidence for correlation to time to progression (lowest nominal p-value 0.03). The dynamic ranges of protein levels measured during the induction treatment period and during the maintenance period were analysed separately for time trends. Evidence for changing trends (up/down) in the levels of MMP-8, TIMP-4 and EGF was observed both during response to induction treatment and at progressive disease, respectively. For three of the proteins (IL-8, Activin A and IGFBP-2), weak evidence for correlation between increasing protein levels during induction with chemotherapy and bevacizumab and time to progression was observed. In conclusion, semi-quantitative profiling of angiogenesis related proteins in patient serum may be a versatile tool to screen for protein patterns aiming at identifying resistance mechanisms of anti-angiogenic treatment in patients with mCRC.
Multiarray on a test strip (MATS): rapid multiplex immunodetection of priority potato pathogens
Multiarray on a test strip (MATS) was developed for the detection of eight important potato pathogens. The proposed assay combines the rapidity of immunochromatography with the high throughput of array techniques. The test zone of the immunochromatographic strip comprises ordered rows of spots containing antibodies specific for different potato pathogens. The assay benefits from the simplicity of immunochromatography; colored immune complexes form at the corresponding spots within the test zone. The presence and intensity of the coloration are used for identification of the target pathogens. The MATS was applied to the simultaneous detection of eight priority potato pathogens, characterized by the following limits of detection: 1 ng/mL for potato virus X and the ordinary type of potato virus Y, 10 ng/mL for potato virus M, 20 ng/mL for potato leaf roll virus, 40 ng/mL for necrotic-type potato virus Y, 100 ng/mL for potato virus S, 300 ng/mL for potato virus A, and 10 4  cells/mL for Clavibacter michiganensis subsp. sepedonicus . Analysis time was 15 min. The observed sensitivity of the MATS was comparable to the traditional enzyme-linked immunosorbent assay. The developed technique was tested on potato leaf extracts, and its efficiency for on-site control of the pathogens was confirmed in 100 % by commercial LFIA test strips. Graphical abstract Location of binding zones in the developed multiarray on a test strip (MATS) for simultaneous detection of eight pathogens
Do-it-yourself protein arrays as high-throughput immunoassays enabled by confined droplets on patterned plasmonic chips
Protein chips and arrays in parallel enable high-throughput protein detection in small-volume biological fluids, however, the limitations in sensitivity, dependence on expensive/bulky external equipment, and the need for specialized technical personnel have restricted their application in clinical and laboratory settings. Here, we present a droplet-based do-it-yourself (DBDIY) array on patterned plasmonic chips for high-throughput immunoassays, via confined droplets and plasmonic enhanced near-infrared (NIR) fluorescence. The assay allows equipment-free microarray fabrication and highly sensitive detection using only a pipette. It dynamically profiles 10 cytokines over 40 days in individual mice with just 6 µL of serum/blood per time point and achieves 100% sensitivity and specificity for C-reactive protein (CRP) in 1 nL of peripheral whole blood samples from 112 children. Scalable to high-throughput analysis of cell culture and serum, this accessible system simplifies workflows, extends utility in resource-limited settings, and offers a next-generation tool for longitudinal animal studies and clinical diagnostics. Protein detection typically requires bulky equipment and large sample volumes. Here, the authors develop a do-it-yourself plasmonic array that enables high-throughput immunoassays from minute volumes using only a pipette, showcasing their approach through longitudinal animal studies and pediatric diagnostics.
Controlling technical variation amongst 6693 patient microarrays of the randomized MINDACT trial
Gene expression data obtained in large studies hold great promises for discovering disease signatures or subtypes through data analysis. It is also prone to technical variation, whose removal is essential to avoid spurious discoveries. Because this variation is not always known and can be confounded with biological signals, its removal is a challenging task. Here we provide a step-wise procedure and comprehensive analysis of the MINDACT microarray dataset. The MINDACT trial enrolled 6693 breast cancer patients and prospectively validated the gene expression signature MammaPrint for outcome prediction. The study also yielded a full-transcriptome microarray for each tumor. We show for the first time in such a large dataset how technical variation can be removed while retaining expected biological signals. Because of its unprecedented size, we hope the resulting adjusted dataset will be an invaluable tool to discover or test gene expression signatures and to advance our understanding of breast cancer. Laurent Jacob et al. develop a workflow and analytical pipeline to remove technical variation from the MINDACT microarray dataset. Their method preserved biological signals and the normalized datasets can be repurposed for the discovery of other biomarkers and signatures for breast cancer.
Digital quantitative assessment of PD-L1 using digital spatial profiling
The assessment of programmed death 1 ligand 1 (PD-L1) expression by Immunohistochemistry (IHC) is the US Food and Drug Administration (FDA)-approved predictive marker to select responders to checkpoint blockade anti-PD-1/PD-L1 axis immunotherapies. Different PD-L1 immunohistochemistry (IHC) assays use different antibodies and different scoring methods in tumor cells and immune cells. Multiple studies have compared the performance of these assays with variable results. Here, we investigate an alternative method for assessment of PD-L1 using a new technology known as digital spatial profiling. We use a previously described standardization tissue microarray (TMA) to assess the accuracy of the method and compare digital spatial profiler (DSP) to each FDA-approved PD-L1 assays, one LDT assay and three quantitative fluorescence assays. The standardized cell line Index tissue microarray contains 10 isogenic cells lines in triplicates expressing various ranges of PD-L1. The dynamic range of PD-L1 digital counts was measured in the ten cell lines on the Index TMA using the GeoMx DSP assay and read on the nCounter platform. The digital method shows very high correlation with immunohistochemistry scored with quantitative software and with quantitative fluorescence. High correlation of PD-L1 digital DSP counts were seen between rows on the same Index TMA. Finally, experiments from two Index TMAs showed reproducibility of DSP counts were independent of variable slide storage time over a three-week period after antibody labeling but before collection of cleaved tags. In summary, DSP appears to have quantitative potential comparable to quantitative immunohistochemistry. It is possible that this technology could be used as a PD-L1 protein measurement system for companion diagnostic testing for immune therapy. Digital spatial profiling is a new high-plex technology with potential to multiplex hundreds of proteins on a single slide. Here the authors validate the digital aspect of the technology on a control tissue microarray with known amounts of PD-L1 expression to show it has quantitative capacity comparable to quantitative immunofluorescence.
Circulating proteins in response to combined-modality therapy in rectal cancer identified by antibody array screening
Background The increasingly complex programs of contemporary cancer therapy emphasize the need for biological indicators of both therapeutic response and adverse effects. One example is combined-modality treatment aimed at improving long-term outcome in patients with locally advanced rectal cancer, which commonly comes at the price of extended limits of patient tolerance. Methods In a prospective study with intensified neoadjuvant treatment of rectal cancer patients, using an antibody array, the profiling of approximately 500 proteins was performed in serial serum samples collected at different stages of the treatment course. Results The small number of proteins whose levels significantly changed after induction neoadjuvant chemotherapy (NACT) expanded substantially following the sequential chemoradiotherapy (CRT) and persisted four weeks later at treatment evaluation before pelvic surgery. Serum levels of proteins selected for validation of the experimental design, lipocalin-2 and matrix metalloproteinase-9, declined after NACT and gradually reverted to baseline values during the remaining neoadjuvant course. Of note, the greater the decline in post-NACT and post-CRT matrix metalloproteinase-9 levels, the more favorable progression-free survival. No correlation was found, however, with diarrhea scores, the clinical correlate of adverse therapeutic effects. Conclusions Even though the findings were indicative of only tumor and not normal tissue effects, multiplex immunoassay analysis of circulating proteins in patients undergoing combined-modality therapy may in principle dissect the contribution of the individual modalities to overall systemic responses in patient outcome and tolerance. Trial registration ClinicalTrials.gov NCT00278694 ; registration date: January 16, 2006, retrospective to enrollment of the first 10 patients of the current report.
Lab-in-a-Tip: a multiplex immunoassay platform based on a self-assembled barcoded protein array
High throughput immunoassay is increasingly crucial for both scientific and clinical applications. Here we propose a “Lab-in-a-Tip” (LIT) concept to fabricate a pipette tip containing a high-density protein array and other essential reagents. The protein array is made by self-assembling digitally encoded microparticles inside the modified tip. Mounted on a robotic workstation, it automates liquid-handling steps. Notably, compared with Luminex, the current gold standard in multiplex immunoassays, such a design enables LIT to demonstrate multiple advantages in terms of analytical sensitivity, speed, and throughput. It detects analyte concentrations as low as fg/ml, representing a sensitivity improvement of two orders of magnitude over Luminex. Incubation time is reduced to 15 minutes from Luminex’s 210 minutes. Furthermore, LIT requires only 10 µl of sample, one-fifth of what Luminex needs. This makes LIT ideal for rapid diagnostics and studies with limited biological samples, greatly expanding its application scope. High-throughput immunoassay is crucial for scientific and clinical applications. Here, the authors introduce a multiplex immunoassay platform engineered by modifying a pipette tip with a self-assembled barcoded protein array. It outperforms the gold standard in sensitivity, speed, and sample volume.