Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
91
result(s) for
"RF coils"
Sort by:
A New Combination of Radio-Frequency Coil Configurations Using High-Permittivity Materials and Inductively Coupled Structures for Ultrahigh-Field Magnetic Resonance Imaging
by
Young-Seung Jo
,
Jeung-Hoon Seo
,
Jun-Young Chung
in
7.0 T MRI
,
Alzheimer's disease
,
birdcage RF coil
2022
In ultrahigh-field (UHF) magnetic resonance imaging (MRI) system, the RF power required to excite the nuclei of the target object increases. As the strength of the main magnetic field (B0 field) increases, the improvement of the RF transmit field (B1+ field) efficiency and receive field (B1− field) sensitivity of radio-frequency (RF) coils is essential to reduce their specific absorption rate and power deposition in UHF MRI. To address these problems, we previously proposed a method to simultaneously improve the B1+ field efficiency and B1− field sensitivity of 16-leg bandpass birdcage RF coils (BP-BC RF coils) by combining a multichannel wireless RF element (MCWE) and segmented cylindrical high-permittivity material (scHPM) comprising 16 elements in 7.0 T MRI. In this work, we further improved the performance of transmit/receive RF coils. A new combination of RF coil with wireless element and HPM was proposed by comparing the BP-BC RF coil with the MCWE and the scHPM proposed in the previous study and the multichannel RF coils with a birdcage RF coil-type wireless element (BCWE) and the scHPM proposed in this study. The proposed 16-ch RF coils with the BCWE and scHPM provided excellent B1+ field efficiency and B1− field sensitivity improvement.
Journal Article
Design and Implementation of Split-Leg Type Elliptical Whole-Body Birdcage RF Coil at 1.5 T MRI
by
Oh, Chang-Hyun
,
Jeong, You-Jin
,
Chung, Han-Jae
in
Design
,
Efficiency
,
electromagnetic simulation
2021
The feasibility and the development of a four-port elliptical birdcage radio frequency (RF) coil for generating a homogenous RF magnetic (B1) field is presented for a space-constrained narrow-bore magnetic resonance imaging (MRI) system. Optimization was performed for the elliptical birdcage RF coil by adjusting the position and the structure of the legs to maximize the B1+-field uniformity. Electromagnetic (EM) simulations based on RF coil circuit co-simulations were performed on a cylindrical uniform phantom and a three-dimensional human model to evaluate the B1+-field uniformity, the transmission efficiency, and the specific absorption rate (SAR) deposition. An elliptical birdcage RF coil was constructed, and its performance was evaluated through network analysis measurements such as S-parameters and Q-factor. Quadrature transmit and receive MRI experiments were conducted using both phantom and in vivo human for validation. The EM simulation results indicate reasonable B1+-field uniformity and transmission efficiency for the proposed elliptical birdcage RF coil. The signal-to-noise ratio and the flip angle maps of the uniform phantom and the in vivo human MR images acquired using an elliptical birdcage (62 cm × 58 cm) were similar to those of a commercial circular birdcage (diameter, 58 cm), thereby indicating acceptable performance. In conclusion, the proposed split-type asymmetric elliptical birdcage RF coil is useful for whole-body MRI applications and can be used for imaging larger human subjects comfortably in a spacious imaging space.
Journal Article
Self-Isolated Dual-Mode High-Pass Birdcage RF Coil for Proton and Sodium MR Imaging at 7 T MRI
2023
This study presents the feasibility of a dual-mode high-pass birdcage RF coil to acquire MR images at both 1H and 23Na frequencies at ultra-high-field MR scanner, 7 T. A dual-mode circuit (DMC) in the dual-mode birdcage (DMBC) RF coil operates at two frequencies, addressing the limitations of sensitivity reduction and isolation between two frequencies as in traditional dual-tuned RF coil. Finite-difference time-domain (FDTD) based electromagnetic (EM) simulations were performed to verify the RF coil at each frequency on the three-dimensional human head model. The DMBC RF coil resonated at proton (1H) and sodium (23Na) frequencies, and also single-tuned high-pass birdcage RF coils were constructed for both 1H and 23Na frequencies. The bench test performance of the RF coils was evaluated using network analysis parameters, including the measurement of scattering parameters (S-parameters) and quality factors (Q-factors). Q-factor of the DMBC coil at 1H port was 10.2% lower than that of 1H single-tuned birdcage (STBC) coil, with a modest SNR reduction of 6.5%. Similarly, the Q-factor for the DMBC coil at 23Na port was 12.3% less than that of 23Na STBC coil, and the SNR showed a minimal reduction of 5.4%. Utilizing the DMBC coil, promising 1H and 23Na MR images were acquired compared to those by using STBC coils. In conclusion, deploying a DMBC 1H/23Na coil has been demonstrated to overcome traditional constraints associated with dual-tuned RF coils, achieving this with only nominal signal attenuation across both nuclei operational frequencies.
Journal Article
Magnetic Resonance Wire Coil Losses Estimation with Finite-Difference Time-Domain Method
by
Barney, Jeff
,
Jayakumar, Naveen Kumar Tumkur
,
Tiberi, Gianluigi
in
Accuracy
,
Approximation
,
Coils
2022
Radiofrequency (RF) coils are used to transmit and receive signals in magnetic resonance (MR) systems. Optimized RF coil design has to take into account strategies to maximize the coil performance by choosing coil sizes and geometry for achieving the best signal-to-noise ratio (SNR). In particular, coil conductor and radiative loss contributions strongly affect the SNR value, with the first mainly playing a role in low-field MR systems especially, while the second could be the dominant coil loss mechanism for high-frequency tuned coils. This paper investigates the accuracy of the finite-difference time-domain (FDTD) method for separately estimating coil conductor and radiative loss contributions. Comparison with finite element method (FEM) analysis and workbench measurements performed on a home-built coil prototype permitted us to validate the simulation results. Moreover, this research, jointly with literature data on sample-induced losses estimation, demonstrates that an FDTD-based solver permits providing an SNR model for coils with various and complicated geometries.
Journal Article
Simulation Validation of an 8-Channel Parallel-Transmit Dipole Array on an Infant Phantom: Including RF Losses for Robust Correlation with Experimental Results
2024
It is crucial to demonstrate a robust correlation between the simulated and manufactured parallel-transmit (pTx) arrays performances to release the currently-used, very restrictive safety margins. In this study, we describe the qualitative and quantitative validation of a simulation model with respect to experimental results for an 8-channel dipole array at 7T. An approach that includes the radiofrequency losses into the simulation model is presented and compared to simulation models neglecting these losses. Simulated S-matrices and individual B1+-field maps were compared with experimentally measured quantities. With the proposed approach, an average relative difference of ~1.1% was found between simulated and experimental reflection coefficients, ~4.2% for the 1st coupling terms, and ~9.4% for the 2nd coupling terms. A maximum normalized root-mean-square error of 4.8% was achieved between experimental and simulated individual B1+-field maps. The effectiveness of the simulation model to accurately predict the B1+-field patterns was assessed, qualitatively and quantitatively, through a comparison with experimental data. We conclude that, using the proposed model for radiofrequency losses, a robust correlation is achieved between simulated and experimental data using the 8-channel dipole array at 7T.
Journal Article
Magnetostatic Simulation and Design of Novel Radiofrequency Coils Based on Transverse Field Current Elements for Magnetic Resonance Applications
by
Galante, Angelo
,
Giovannetti, Giulio
,
Alecci, Marcello
in
Design
,
Magnetic fields
,
magnetic resonance imaging
2023
Radiofrequency (RF) coils are key components in Magnetic Resonance (MR) systems and can be categorized into volume and surface coils according to their shapes. Volume RF coils can generate a uniform field in a large central sample’s region, while surface RF coils, usually smaller than volume coils, typically have a higher Signal-to-Noise Ratio (SNR) in a reduced Region Of Interest (ROI) close to the coil plane but a relatively poorer field homogeneity. Circular and square loops are the simplest and most used design for developing axial field surface RF coils. However, for specific MR applications, the use of dedicated transverse field RF coils can be necessary or advantageous. Building on a previously developed and validated RF coil simulator, based on the magnetostatic approach, here we explore the potential applications of novel multiple axial field and transverse field surface RF coils in non-standard configurations. We demonstrate via numerical simulations that simple volume RF coils, matching a Helmholtz-like design, can be built with two identical transverse field RF coils separated by a given distance. Following well-known principles, the SNR of such novel configurations can be improved by a factor of up to √2 by combining two 90° rotated coils, producing, inside a central ROI, a circularly polarized B1 field.
Journal Article
The future of ultra-high field MRI and fMRI for study of the human brain
2012
MRI and fMRI have been used for about three and two decades respectively and much has changed over this time period, both in the quality of the data and in the range of applications for studying the brain. Apart from resolution improvements from around 4mm in the early days to below 0.5mm with modern technology, novel uses of contrast have led to the ability to sensitize images to some of the brain's structural properties at the cellular scale as well as study the localization and organization of brain function at the level of cortical columns. These developments have in part been facilitated by a continuing drive to increase the magnetic field strength. Will the next few decades see similar improvements? Here we will discuss current state of high field MRI, expected further increases in field strength, and improvements expected with these increases.
► MRI magnetic field strength has continuously increased. ► This has catalyzed new applications and is improving sensitivity and resolution. ► Further improvements are expected with future increases in magnetic field. ► Visualization of novel functional and structural features is anticipated. ► It may not be practical to increase magnetic field strength beyond 14T.
Journal Article
Dual-Channel Transverse Fields Radiofrequency Coils for 1.5 T Magnetic Resonance Imaging
by
Galante, Angelo
,
Burov, Denis
,
Rollo, Rocco
in
Approximation
,
decoupling
,
dual-channel RF coils
2024
This theoretical study presents the design and analytical/numerical optimization of novel dual-channel transverse fields radiofrequency (RF) surface coils for 1.5 T Magnetic Resonance Imaging (MRI). The research explores a planar setup with two channels on a row with aligned spatial orientation of the RF coils, aiming to solve a common design drawback of single-channel transverse field RF coils: the reduced Field Of View (FOV) along the direction of the RF field. A significant challenge in this design is the efficient decoupling of two sets of transverse field RF coils to prevent mutual interference. Our modeling approach integrates thin wire theoretical modeling, magnetostatic computation for strip conductor coils, and their full-wave electromagnetic simulation. Key findings at 64 MHz demonstrate that strategic geometric placement among the two-channel RF coil and the introduction of geometrical asymmetry in the design of the individual RF coils does minimize the mutual inductance, paving the way for effective dual-channel MRI applications. This decoupling approach allows to enhance the FOV, providing a theoretical framework for the development of optimized dual-channel transverse field RF coil configurations. The current design was validated with full-wave numerical study at 64 MHz (1H, 1.5 T), has the potential to be extended at lower or higher frequencies, and the presence of lossy samples needs to be considered in the latter case.
Journal Article