Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
1 result(s) for "Rectoprostatic space"
Sort by:
Long-term evaluation of the safety of a rectal-prostate spacer, the ProSpace® balloon, in patients treated with radiotherapy for prostate cancer
A bstract Background Due to the close proximity of the prostate and rectum, rectal toxicity remains a major problem in patient treated by radiotherapy for prostate adenocarcinoma. One method of increasing the distance between the prostate and the rectum is to use a spacer implanted into the rectoprostatic space. This report describes the long-term outcomes obtained with a new ballon spacer. Methods Patients treated with curative radiotherapy for low- or intermediate-risk prostate adenocarcinoma, who underwent insertion of the ProSpace® (BioProtect Ltd, Tzur Yigal, Israel) rectal-prostate balloon spacer, were included. The main objective was to evaluate the dosimetric benefit of the spacer for OARs. The secondary objectives were to evaluate the feasibility and tolerability of ProSpace® balloon placement and to evaluate its long-term therapeutic efficacy and tolerance. Results Between October 2013 and March 2015, 16 patients were enrolled in the Pasteur Clinic, Toulouse, France. The median follow-up was 85.5 months. From top to bottom, the space created was a mean of 16.3 mm (range: 11–20.5 mm) at the base of the prostate, 12.1 mm (range: 4–16 mm) at the middle and 8.9 mm at the apex (range: 5–15 mm). On average, rectal volumes receiving a dose of 70 Gy, 60 Gy and 50 Gy were significantly lower after balloon implantation: -4.81 cc (1.5 vs. 6.3; p  < 0.0005), -8.08 cc (6.4 vs. 14.5; p  = 0.002) and -9.06 cc (16.7 vs. 25.7; p  = 0.003), respectively. There were significant differences in coverage after balloon implantation: Median V95% ( p  < 0.0005), median Dmin ( p  = 0.01) and median V98% ( p  < 0.001) were higher after balloon implantation. At 5 years, cumulative gastrointestinal toxicity was grade 1 in 6% (1/16 patients). No toxicity of grade 2 or higher was found. At 5 years, no urinary toxicity grade 3 or 4 toxicity was found. The QoL was not deteriorated. Conclusions The use of the ProSpace® balloon seems to be well accepted by patients, allowing a double dosimetric gain: a decrease in doses received by the rectum and an improvement in the coverage of the high-risk PTV. The long-term gastrointestinal toxicity remains low and QoL is preserved in all treated patients.