Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
23,567
result(s) for
"Respiratory rate"
Sort by:
The effect of prone position on oxygen saturation, blood gas parameters, and respiratory rate in intensive care patients with COVID-19-induced ARDS
2025
This study aimed to evaluate the short-term effect of prone positioning on oxygen saturation, arterial blood gas parameters, and respiratory rate in intensive care patients with COVID-19-induced acute respiratory distress syndrome (ARDS). This randomized experimental study used a six-measure time series design with control and intervention groups. A total of 90 intubated patients diagnosed with COVID-19 and ARDS were enrolled, with 45 patients in the experimental group and 45 in the control group. The experimental group received a 30-minute prone positioning session, while no intervention was applied to the control group. Data were collected using a Demographic Information Form and a structured form to record oxygen saturation, blood gas parameters, and respiratory rate. This study was registered at ClinicalTrials.gov (Identifier: NCT06997666; first posted on 28/05/2025). Age and gender were comparable between groups (
p
> 0.05). Patients in the experimental group demonstrated higher mean values of peripheral oxygen saturation (SpO₂), arterial oxygen saturation (SaO₂), and partial pressure of oxygen (PaO₂), along with lower PaCO₂ and respiratory rates. No significant changes were observed in sodium or lactate levels. All effects observed were immediate and short-term. No adverse events or unintended effects were reported. A single short-duration session of prone positioning resulted in immediate physiological improvements in oxygenation, ventilation parameters, and respiratory rate in patients with COVID-19-related ARDS. Further studies are needed to assess long-term clinical outcomes and sustained benefits.
Journal Article
High-flow nasal therapy vs standard oxygen during breaks off noninvasive ventilation for acute respiratory failure: A pilot randomized controlled trial
by
Pisani, Lara
,
Khoja, Alia
,
Price, Lori Lyn
in
Aged
,
Aged, 80 and over
,
Chronic obstructive pulmonary disease
2018
To assess the role of high-flow nasal therapy (HFNT) compared to standard oxygen (SO) as complementary therapy to non-invasive ventilation (NIV).
Multicenter trial including patients (n = 54) anticipated to receive NIV for ≥24 h due to acute or acute-on-chronic respiratory failure. Subjects were randomized (1:1) to SO or HFNT during breaks off NIV. Primary outcome was total time on and off NIV. Secondary outcomes were comfort and dyspnea, respiratory rate (RR), oxygen saturation (SpO2), tolerance and side effects.
Total time per patient on NIV (1315 vs 1441 min) and breaks (1362 vs 1196 min), and mean duration of each break (520 vs 370 min) were similar in the HFNT and SO arms (p > .05).
Comfort score was higher on HFNT than on SO (8.3 ± 2.7 vs 6.9 ± 2.3, p = .001). Dyspnea, RR and SpO2 were similar in the two arms, but the increase in RR and dyspnea seen with SO during breaks did not occur with HFNT.
Compared to SO, HFNT did not reduce time on NIV. However, it was more comfortable and the increase in RR and dyspnea seen with SO did not occur with HFNT. Therefore, HFNT could be a suitable alternative to SO during breaks off NIV.
•Pilot randomized trial assessing the role of HFNT as complementary therapy to NIV.•HFNT does not affect the time on and off NIV compared to SO.•HFNT is well tolerated and leads to greater comfort than SO.•HFNT prevents increase in RR and dyspnea observed with SO during breaks off NIV.•HFNT could be a suitable alternative to SO during breaks off NIV.
Journal Article
Conventional pulse transit times as markers of blood pressure changes in humans
by
Chandrasekhar, Anand
,
Zhu, Junxi
,
Mestha, Lalit K.
in
692/4019
,
692/499
,
Biomarkers - metabolism
2020
Pulse transit time (PTT) represents a potential approach for cuff-less blood pressure (BP) monitoring. Conventionally, PTT is determined by (1) measuring (a) ECG and ear, finger, or toe PPG waveforms or (b) two of these PPG waveforms and (2) detecting the time delay between the waveforms. The conventional PTTs (cPTTs) were compared in terms of correlation with BP in humans. Thirty-two volunteers [50% female; 52 (17) (mean (SD)) years; 25% hypertensive] were studied. The four waveforms and manual cuff BP were recorded before and after slow breathing, mental arithmetic, cold pressor, and sublingual nitroglycerin. Six cPTTs were detected as the time delays between the ECG R-wave and ear PPG foot, R-wave and finger PPG foot [finger pulse arrival time (PAT)], R-wave and toe PPG foot (toe PAT), ear and finger PPG feet, ear and toe PPG feet, and finger and toe PPG feet. These time delays were also detected via PPG peaks. The best correlation by a substantial extent was between toe PAT via the PPG foot and systolic BP [− 0.63 ± 0.05 (mean ± SE); p < 0.001 via one-way ANOVA]. Toe PAT is superior to other cPTTs including the popular finger PAT as a marker of changes in BP and systolic BP in particular.
Journal Article
Continuous Monitoring of Vital Signs Using Cameras: A Systematic Review
2022
In recent years, noncontact measurements of vital signs using cameras received a great amount of interest. However, some questions are unanswered: (i) Which vital sign is monitored using what type of camera? (ii) What is the performance and which factors affect it? (iii) Which health issues are addressed by camera-based techniques? Following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement, we conduct a systematic review of continuous camera-based vital sign monitoring using Scopus, PubMed, and the Association for Computing Machinery (ACM) databases. We consider articles that were published between January 2018 and April 2021 in the English language. We include five vital signs: heart rate (HR), respiratory rate (RR), blood pressure (BP), body skin temperature (BST), and oxygen saturation (SpO2). In total, we retrieve 905 articles and screened them regarding title, abstract, and full text. One hundred and four articles remained: 60, 20, 6, 2, and 1 of the articles focus on HR, RR, BP, BST, and SpO2, respectively, and 15 on multiple vital signs. HR and RR can be measured using red, green, and blue (RGB) and near-infrared (NIR) as well as far-infrared (FIR) cameras. So far, BP and SpO2 are monitored with RGB cameras only, whereas BST is derived from FIR cameras only. Under ideal conditions, the root mean squared error is around 2.60 bpm, 2.22 cpm, 6.91 mm Hg, 4.88 mm Hg, and 0.86 °C for HR, RR, systolic BP, diastolic BP, and BST, respectively. The estimated error for SpO2 is less than 1%, but it increases with movements of the subject and the camera-subject distance. Camera-based remote monitoring mainly explores intensive care, post-anaesthesia care, and sleep monitoring, but also explores special diseases such as heart failure. The monitored targets are newborn and pediatric patients, geriatric patients, athletes (e.g., exercising, cycling), and vehicle drivers. Camera-based techniques monitor HR, RR, and BST in static conditions within acceptable ranges for certain applications. The research gaps are large and heterogeneous populations, real-time scenarios, moving subjects, and accuracy of BP and SpO2 monitoring.
Journal Article
Development and Pilot Test of a Virtual Reality Respiratory Biofeedback Approach
by
Göritz, Anja S
,
Blum, Johannes
,
Rockstroh Christoph
in
Arrhythmia
,
Biofeedback
,
Computer applications
2020
Breathing exercises with biofeedback have benefits over breathing exercises without biofeedback. However, the traditional measurement of respiratory signals that is required as part of feeding back the breath incurs high cost and effort. We propose a novel virtual reality (VR) based approach to respiratory biofeedback that utilizes the positionally tracked hand controllers integrated into modern VR systems to capture and feedback the respiration-induced abdominal movements. In a randomized controlled laboratory study, we investigated the feasibility and efficacy of the developed biofeedback algorithm. In total, 72 participants performed a short breathing exercise in VR with or without respiratory biofeedback. The feedback integration resulted in a satisfactory user experience, a heightened breath awareness, a greater focus on slow diaphragmatic breathing and an increased respiratory sinus arrhythmia. This evidences that the novel biofeedback approach is low-cost, unobtrusive, usable and effective in increasing breath awareness and promoting slow diaphragmatic breathing in the context of VR-based breathing exercises. Future studies need to investigate the broader applicability and long-term effects.
Journal Article
Effect of difelikefalin, a selective kappa opioid receptor agonist, on respiratory depression: A randomized, double‐blind, placebo‐controlled trial
by
Setnik, Beatrice S.
,
Torjman, Marc C.
,
Munera, Catherine L.
in
Adolescent
,
Adult
,
Adverse events
2021
Difelikefalin, a selective kappa opioid receptor agonist designed to limit central nervous system (CNS) penetration, is under development for the treatment of pruritus. Its hydrophilic, small‐peptidic structure limits CNS entry, minimizing potential CNS‐mediated adverse events (AEs). This study assessed the effect of difelikefalin on key relevant measures of respiratory depression in healthy volunteers. This single‐center, randomized, double‐blind, placebo‐controlled, three‐way crossover study enrolled healthy, nonsmoking volunteers. Subjects were randomized to 1 of 3 treatment sequences of difelikefalin (1.0 or 5.0 mcg/kg i.v.) or placebo on sequential days with an intervening 24 (±2) h washout period. The primary end points included incidence of increased end‐tidal carbon dioxide (ETCO2) greater than or equal to 10 mm Hg versus baseline or a level greater than 50 mm Hg sustained greater than or equal to 30 seconds, and incidence of reduction in saturation of peripheral oxygen (SpO2) to less than 92% sustained greater than or equal to 30 seconds. Secondary end points included incidence of reduced respiratory rate and other safety assessments. Fifteen subjects were randomized and completed the study. No subject on placebo or difelikefalin met the increased ETCO2 or reduced SpO2 primary end point criteria for respiratory depression. All respiratory measures in each group remained near baseline values during 4‐h postdose observations. No subject met the reduced respiratory rate criterion or experienced clinically significant changes in ETCO2, SpO2, or respiratory rate. The most commonly reported treatment‐emergent AEs (TEAEs; ≥20% of subjects) were paresthesia, hypoesthesia, and somnolence in the difelikefalin arms. All TEAEs were mild and resolved without intervention. Difelikefalin 1.0 and 5.0 mcg/kg i.v. did not produce respiratory depression.
Journal Article
Effects of s-ketamine and midazolam on respiratory variability: A randomized controlled pilot trial
by
Alvarez-Jimenez, Ricardo
,
Evers, Andrea W. M.
,
van den Bosch, Oscar F. C.
in
Adaptability
,
Adult
,
Alfentanil
2025
S-ketamine and midazolam are frequently used to provide sedation while maintaining spontaneous respiration. However, the effects of these agents on respiratory variability, which reflects the adaptability of the respiratory system, have not been thoroughly explored. We evaluated these effects in a randomized controlled pilot trial. This study was conducted as part of a randomized controlled trial originally designed to assess the effects of s-ketamine conditioning on pain sensitivity in patients with fibromyalgia syndrome. Participants were randomly assigned to receive an infusion of either s-ketamine (0.3 mg kg -1 h -1 ), midazolam (0.05 mg kg -1 h -1 ), or saline in a blinded fashion. Mean respiratory rate, variability of respiratory rate (VRR), and variability of tidal volume (VTV) were measured continuously and non-invasively with a bio-impedance method. Changes during drug infusion were compared in a linear mixed model to assess the effects of s-ketamine and midazolam compared to saline. Data were analyzed for 57 experiments in 28 participants. Their median baseline variabilities of respiratory rate and tidal volume were 0.19 (IQR: 0.16–0.25) and 0.23 (0.19–0.34), respectively. While mean respiratory rate was not affected, midazolam resulted in a significant decrease in both VRR (ß = −0.071, 95% CI: −0.120 to −0.021) and VTV (ß = −0.117, 95% CI: −0.170 to −0.062). In contrast, s-ketamine appeared to produce a smaller decrease in VTV (ß = −0.062, 95% CI: −0.118 to −0.003) with VRR remaining unaffected (ß = −0.036, 95% CI: −0.092 to 0.019). In conclusion, our study demonstrates that midazolam reduces respiratory variability, potentially impairing the adaptability of the respiratory system. In contrast, s-ketamine largely preserved respiratory variability, suggesting it may be a safer alternative for sedation in patients with impaired spontaneous breathing. Further studies are needed to assess the clinical implications of these observations in patients undergoing sedation.
Journal Article
Non-Contact Monitoring of Breathing Pattern and Respiratory Rate via RGB Signal Measurement
by
Massaroni, Carlo
,
Lo Presti, Daniela
,
Schena, Emiliano
in
Abdomen
,
Algorithms
,
breathing pattern
2019
Among all the vital signs, respiratory rate remains the least measured in several scenarios, mainly due to the intrusiveness of the sensors usually adopted. For this reason, all contactless monitoring systems are gaining increasing attention in this field. In this paper, we present a measuring system for contactless measurement of the respiratory pattern and the extraction of breath-by-breath respiratory rate. The system consists of a laptop’s built-in RGB camera and an algorithm for post-processing of acquired video data. From the recording of the chest movements of a subject, the analysis of the pixel intensity changes yields a waveform indicating respiratory pattern. The proposed system has been tested on 12 volunteers, both males and females seated in front of the webcam, wearing both slim-fit and loose-fit t-shirts. The pressure-drop signal recorded at the level of nostrils with a head-mounted wearable device was used as reference respiratory pattern. The two methods have been compared in terms of mean of absolute error, standard error, and percentage error. Additionally, a Bland–Altman plot was used to investigate the bias between methods. Results show the ability of the system to record accurate values of respiratory rate, with both slim-fit and loose-fit clothing. The measuring system shows better performance on females. Bland–Altman analysis showed a bias of −0.01 breaths · min − 1 , with respiratory rate values between 10 and 43 breaths · min − 1 . Promising performance has been found in the preliminary tests simulating tachypnea.
Journal Article
Identifying vital sign trajectories to predict 28-day mortality of critically ill elderly patients with acute respiratory distress syndrome
by
Yuan, Zhongshang
,
Li, Mingzhuo
,
Lao, Jiahui
in
28-day mortality
,
Acute respiratory distress syndrome
,
Aged
2024
Background
The mortality rate of acute respiratory distress syndrome (ARDS) increases with age (≥ 65 years old) in critically ill patients, and it is necessary to prevent mortality in elderly patients with ARDS in the intensive care unit (ICU). Among the potential risk factors, dynamic subphenotypes of respiratory rate (RR), heart rate (HR), and respiratory rate-oxygenation (ROX) and their associations with 28-day mortality have not been clearly explored.
Methods
Based on the eICU Collaborative Research Database (eICU-CRD), this study used a group-based trajectory model to identify longitudinal subphenotypes of RR, HR, and ROX during the first 72 h of ICU stays. A logistic model was used to evaluate the associations of trajectories with 28-day mortality considering the group with the lowest rate of mortality as a reference. Restricted cubic spline was used to quantify linear and nonlinear effects of static RR-related factors during the first 72 h of ICU stays on 28-day mortality. Receiver operating characteristic (ROC) curves were used to assess the prediction models with the Delong test.
Results
A total of 938 critically ill elderly patients with ARDS were involved with five and 5 trajectories of RR and HR, respectively. A total of 204 patients fit 4 ROX trajectories. In the subphenotypes of RR, when compared with group 4, the odds ratios (ORs) and 95% confidence intervals (CIs) of group 3 were 2.74 (1.48–5.07) (
P
= 0.001). Regarding the HR subphenotypes, in comparison to group 1, the ORs and 95% CIs were 2.20 (1.19–4.08) (
P
= 0.012) for group 2, 2.70 (1.40–5.23) (
P
= 0.003) for group 3, 2.16 (1.04–4.49) (
P
= 0.040) for group 5. Low last ROX had a higher mortality risk (
P
linear = 0.023,
P
nonlinear = 0.010). Trajectories of RR and HR improved the predictive ability for 28-day mortality (AUC increased by 2.5%,
P
= 0.020).
Conclusions
For RR and HR, longitudinal subphenotypes are risk factors for 28-day mortality and have additional predictive enrichment, whereas the last ROX during the first 72 h of ICU stays is associated with 28-day mortality. These findings indicate that maintaining the health dynamic subphenotypes of RR and HR in the ICU and elevating static ROX after initial critical care may have potentially beneficial effects on prognosis in critically ill elderly patients with ARDS.
Journal Article
Physiological factors determining downhill vs uphill running endurance performance
2021
Recent studies investigated the determinants of trail running performance (i.e., combining uphill (UR) and downhill running sections (DR)), while the possible specific physiological factors specifically determining UR vs DR performances (i.e., isolating UR and DR) remain presently unknown. This study aims to determine the cardiorespiratory responses to outdoor DR vs UR time-trial and explore the determinants of DR and UR performance in highly trained runners.
Randomized controlled trial.
Ten male highly-trained endurance athletes completed 5-km DR and UR time-trials (average grade: ±8%) and were tested for maximal oxygen uptake, lower limb extensor maximal strength, local muscle endurance, leg musculotendinous stiffness, vertical jump ability, explosivity/agility and sprint velocity. Predictors of DR and UR performance were investigated using correlation and commonality regression analyses.
Running velocity was higher in DR vs UR time-trial (20.4±1.0 vs 12.0±0.5km·h−1, p<0.05) with similar average heart rate (95±2% vs 94±2% maximal heart rate; p>0.05) despite lower average V̇O2 (85±8% vs 89±7% V̇O2max; p<0.05). Velocity at V̇O2max (vV̇O2max) body mass index (BMI) and maximal extensor strength were significant predictors of UR performance (r2=0.94) whereas vV̇O2max, leg musculotendinous stiffness and maximal extensor strength were significant predictors of DR performance (r2=0.84).
Five-km UR and DR running performances are both well explained by three independent predictors. If two predictors are shared between UR and DR performances (vV̇O2max and maximal strength), their relative contribution is different and, importantly, the third predictor appears very specific to the exercise modality (BMI for UR vs leg musculotendinous stiffness for DR).
Journal Article