Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
868 result(s) for "Reverse Transcriptase Polymerase Chain Reaction - economics"
Sort by:
A sensitive and affordable multiplex RT-qPCR assay for SARS-CoV-2 detection
With the ongoing COVID-19 (Coronavirus Disease 2019) pandemic, caused by the novel coronavirus SARS-CoV-2 (Severe Acute Respiratory Syndrome Coronavirus 2), there is a need for sensitive, specific, and affordable diagnostic tests to identify infected individuals, not all of whom are symptomatic. The most sensitive test involves the detection of viral RNA using RT-qPCR (quantitative reverse transcription PCR), with many commercial kits now available for this purpose. However, these are expensive, and supply of such kits in sufficient numbers cannot always be guaranteed. We therefore developed a multiplex assay using well-established SARS-CoV-2 targets alongside a human cellular control ( RPP30 ) and a viral spike-in control (Phocine Herpes Virus 1 [PhHV-1]), which monitor sample quality and nucleic acid extraction efficiency, respectively. Here, we establish that this test performs as well as widely used commercial assays, but at substantially reduced cost. Furthermore, we demonstrate >1,000-fold variability in material routinely collected by combined nose and throat swabbing and establish a statistically significant correlation between the detected level of human and SARS-CoV-2 nucleic acids. The inclusion of the human control probe in our assay therefore provides a quantitative measure of sample quality that could help reduce false-negative rates. We demonstrate the feasibility of establishing a robust RT-qPCR assay at approximately 10% of the cost of equivalent commercial assays, which could benefit low-resource environments and make high-volume testing affordable.
Assessment of Specimen Pooling to Conserve SARS CoV-2 Testing Resources
Abstract Objectives To establish the optimal parameters for group testing of pooled specimens for the detection of SARS-CoV-2. Methods The most efficient pool size was determined to be five specimens using a web-based application. From this analysis, 25 experimental pools were created using 50 µL from one SARS-CoV-2 positive nasopharyngeal specimen mixed with 4 negative patient specimens (50 µL each) for a total volume of 250 µL. Viral RNA was subsequently extracted from each pool and tested using the CDC SARS-CoV-2 RT-PCR assay. Positive pools were consequently split into individual specimens and tested by extraction and PCR. This method was also tested on an unselected group of 60 nasopharyngeal specimens grouped into 12 pools. Results All 25 pools were positive with cycle threshold (Ct) values within 0 and 5.03 Ct of the original individual specimens. The analysis of 60 specimens determined that 2 pools were positive followed by identification of 2 individual specimens among the 60 tested. This testing was accomplished while using 22 extractions/PCR tests, a savings of 38 reactions. Conclusions When the incidence rate of SARS-CoV-2 infection is 10% or less, group testing will result in the saving of reagents and personnel time with an overall increase in testing capability of at least 69%.
Optimized qRT-PCR Approach for the Detection of Intra- and Extra-Cellular SARS-CoV-2 RNAs
The novel coronavirus SARS-CoV-2 is the causative agent of the acute respiratory disease COVID-19, which has become a global concern due to its rapid spread. Meanwhile, increased demand for testing has led to a shortage of reagents and supplies and compromised the performance of diagnostic laboratories in many countries. Both the World Health Organization (WHO) and the Center for Disease Control and Prevention (CDC) recommend multi-step RT-PCR assays using multiple primer and probe pairs, which might complicate the interpretation of the test results, especially for borderline cases. In this study, we describe an alternative RT-PCR approach for the detection of SARS-CoV-2 RNA that can be used for the probe-based detection of clinical isolates in diagnostics as well as in research labs using a low-cost SYBR green method. For the evaluation, we used samples from patients with confirmed SARS-CoV-2 infections and performed RT-PCR assays along with successive dilutions of RNA standards to determine the limit of detection. We identified an M-gene binding primer and probe pair highly suitable for the quantitative detection of SARS-CoV-2 RNA for diagnostic and research purposes.
Pooled RNA sample reverse transcriptase real time PCR assay for SARS CoV-2 infection: A reliable, faster and economical method
Corona virus disease 2019 (COVID-19) which initially started as a cluster of pneumonia cases in the Wuhan city of China has now become a full-blown pandemic. Timely diagnosis of COVID-19 is the key in containing the pandemic and breaking the chain of transmission. In low- and middle-income countries availability of testing kits has become the major bottleneck in testing. Novel methods like pooling of samples are the need of the hour. We undertook this study to evaluate a novel protocol of pooling of RNA samples/elutes in performance of PCR for SARS CoV-2 virus. Extracted RNA samples were randomly placed in pools of 8 on a 96 well plate. Both individual RNA (ID) and pooled RNA RT-qPCR for the screening E gene were done in the same plate and the positivity for the E gene was seen. The present study demonstrated that pool testing with RNA samples can easily detect even up to a single positive sample with Ct value as high as 38. The present study also showed that the results of pool testing is not affected by number of positive samples in a pool. Pooling of RNA samples can reduce the time and expense, and can help expand diagnostic capabilities, especially during constrained supply of reagents and PCR kits for the diagnosis of SARS-CoV-2 infection.
Optimized and scalable synthesis of magnetic nanoparticles for RNA extraction in response to developing countries' needs in the detection and control of SARS-CoV-2
Ecuador is one of the most affected countries, with the coronavirus disease 2019 (COVID-19) infection, in Latin America derived from an ongoing economic crisis. One of the most important methods for COVID-19 detection is the use of techniques such as real time RT-PCR based on a previous extraction/purification of RNA procedure from nasopharyngeal cells using functionalized magnetic nanoparticles (MNP). This technique allows the processing of ~ 10,000 tests per day in private companies and around hundreds per day at local Universities guaranteeing to reach a wide range of the population. However, the main drawback of this method is the need for specialized MNP with a strong negative charge for the viral RNA extraction to detect the existence of the SARS-CoV-2 virus. Here we present a simplified low cost method to produce 10 g of nanoparticles in 100 mL of solution that was scaled to one litter by parallelizing the process 10 times in just two days and allowing for the possibility of making ~ 50,000 COVID-19 tests. This communication helps in reducing the cost of acquiring MNP for diverse biomolecular applications supporting developing country budgets constraints and chemical availability specially during the COVID-19 International Health Emergency.
Assessing the value of PCR assays in oral fluid samples for detecting African swine fever, classical swine fever, and foot-and-mouth disease in U.S. swine
Oral fluid sampling and testing offers a convenient, unobtrusive mechanism for evaluating the health status of swine, especially grower and finisher swine. This assessment evaluates the potential testing of oral fluid samples with real-time reverse-transcriptase polymerase chain reaction (rRT-PCR) to detect African swine fever, classical swine fever, or foot-and-mouth disease for surveillance during a disease outbreak and early detection in a disease-free setting. We used a series of logical arguments, informed assumptions, and a range of parameter values from literature and industry practices to examine the cost and value of information provided by oral fluid sampling and rRT-PCR testing for the swine foreign animal disease surveillance objectives outlined above. Based on the evaluation, oral fluid testing demonstrated value for both settings evaluated. The greatest value was in an outbreak scenario, where using oral fluids would minimize disruption of animal and farm activities, reduce sample sizes by 23%-40%, and decrease resource requirements relative to current individual animal sampling plans. For an early detection system, sampling every 3 days met the designed prevalence detection threshold with 0.95 probability, but was quite costly. Implementation of oral fluid testing for African swine fever, classical swine fever, or foot-and-mouth disease surveillance is not yet possible due to several limitations and information gaps. The gaps include validation of PCR diagnostic protocols and kits for African swine fever, classical swine fever, or foot-and-mouth disease on swine oral fluid samples; minimal information on test performance in a field setting; detection windows with low virulence strains of some foreign animal disease viruses; and the need for confirmatory testing protocol development.
Quantifying RNA allelic ratios by microfluidic multiplex PCR and sequencing
For allele-specific expression and RNA editing studies, targeted RNA sequencing using microfluidic multiplexed PCR (mmPCR-seq) gives robust high-throughput measurements of allelic ratios across the dynamic range of gene expression, even for low-quantity or low-quality RNA. We developed a targeted RNA sequencing method that couples microfluidics-based multiplex PCR and deep sequencing (mmPCR-seq) to uniformly and simultaneously amplify up to 960 loci in 48 samples independently of their gene expression levels and to accurately and cost-effectively measure allelic ratios even for low-quantity or low-quality RNA samples. We applied mmPCR-seq to RNA editing and allele-specific expression studies. mmPCR-seq complements RNA-seq for studying allelic variations in the transcriptome.
Evaluation of custom multiplex real - time RT - PCR in comparison to fast - track diagnostics respiratory 21 pathogens kit for detection of multiple respiratory viruses
Background Severe acute respiratory infections in children can be fatal, rapid identification of the causative agent and timely treatment can be life saving. Multiplex real time RT-PCR helps in simultaneous detection of multiple viruses saving cost, time and labour. Commercially available multiplex real time RT-PCR kits are very expensive. Therefore the aim of the present study was to develop a cost effective multiplex real time RT-PCR for the detection of 18 respiratory viruses and compare it with an in-vitro diagnostics approved Fast Track Diagnostic Respiratory Pathogens 21 Kit (FTD). Methods Nasopharyngeal aspirates and throat swabs were collected and processed for extraction of nucleic acid using an automated extraction system and multiplex real time RT-PCR was performed using the FTD kit and a custom assay on 356 samples. Results Custom and FTD assays detected one or more respiratory viruses in 268 (75.29 %) and 262 (73.60 %) samples respectively. The concordance between the custom assay and the FTD assay was 100 % for HCoV OC43, HCoV 229E, HPIV-1, HPIV-2, HBoV, HPeV, Flu A, and Influenza A (H1N1)pdm09 and 94.66 – 99.71 % for the remaining viruses; Flu B (99.71 %), HRV (99.71 %), HPIV-3 (98.87 %), HPIV-4 (99.43 %), HCoV NL63 (99.71 %), HMPV A/B (99.71 %), RSV A/B (94.66 %), EV (98.31 %), HCoV HKU1 (99.71 %), HAdV (99.71 %). Major discrepancy was observed for RSV A/B, which was over detected in 18 samples by the custom assay as compared to the FTD assay. The custom assay was much cheaper than the FTD assay and the time taken was only 29 min more. Conclusion The custom primer and probe mix was found to be comparable to the FTD assay with good concordance but was much cheaper and the time taken for reporting was only 29 min more. The low cost custom multiplex RT-PCR can be a useful alternative to the costly FTD kit for rapid identification of viral aetiology in resource limited settings.
A Rapid and Low-Cost PCR Thermal Cycler for Low Resource Settings
Many modern molecular diagnostic assays targeting nucleic acids are typically confined to developed countries or to the national reference laboratories of developing-world countries. The ability to make technologies for the rapid diagnosis of infectious diseases broadly available in a portable, low-cost format would mark a revolutionary step forward in global health. Many molecular assays are also developed based on polymerase chain reactions (PCR), which require thermal cyclers that are relatively heavy (>20 pounds) and need continuous electrical power. The temperature ramping speed of most economical thermal cyclers are relatively slow (2 to 3 °C/s) so a polymerase chain reaction can take 1 to 2 hours. Most of all, these thermal cyclers are still too expensive ($2k to $4k) for low-resource setting uses. In this article, we demonstrate the development of a low-cost and rapid water bath based thermal cycler that does not require active temperature control or continuous power supply during PCR. This unit costs $130 to build using commercial off-the-shelf items. The use of two or three vacuum-insulated stainless-steel Thermos food jars containing heated water (for denaturation and annealing/extension steps) and a layer of oil on top of the water allow for significantly stabilized temperatures for PCR to take place. Using an Arduino-based microcontroller, we automate the \"archaic\" method of hand-transferring PCR tubes between water baths. We demonstrate that this innovative unit can deliver high speed PCR (17 s per PCR cycle) with the potential to go beyond the 1,522 bp long amplicons tested in this study and can amplify from templates down to at least 20 copies per reaction. The unit also accepts regular PCR tubes and glass capillary tubes. The PCR efficiency of our thermal cycler is not different from other commercial thermal cyclers. When combined with a rapid nucleic acid detection approach, the thermos thermal cycler (TTC) can enable on-site molecular diagnostics in low-resource settings.
Efficient SARS-CoV-2 detection in unextracted oro-nasopharyngeal specimens by rRT-PCR with the Seegene Allplex™ 2019-nCoV assay
Background The fight against the COVID-19 pandemic has created an urgent need to rapidly detect infected people. The challenge for clinical laboratories has been finding a high throughput, cost-efficient, and accurate testing method in the context of extraction reagents shortage on a global scale. To answer this need, we studied SARS-CoV-2 detection in oro-nasopharyngeal (ONP) swabs stored in Universal Transport Media (UTM) or in RNase-free water by rRT-PCR with Seegene Allplex™ 2019-nCoV assay without RNA extraction. Results Optimal results were obtained when swabs stored in UTM were diluted 1/5 and 1/2 in RNase-free water. Thermal lysis before rRT-PCR testing slightly improved detection rate. In addition, proteinase K (PK) treatment allowed for a significant reduction of invalid results and increased sensitivity for detection of low viral load specimens. In a panel of positive samples with all 3 viral genes amplified and N gene Cycle threshold values (C t values) from 15 to 40, our detection rate was 98.9% with PK and 94.4% without. In a challenging panel of low positive samples with only the N gene being detectable at C t values > 30, detection rate was increased from 53.3 to 76.7% with the addition of PK, and invalid rate fell off from 18.3 to 0%. Furthermore, we demonstrated that our method reliably detects specimens with C t values up to 35, whereas false negative samples become frequent above this range. Finally, we show that swabs should be stored at − 70 °C rather than 4 °C when testing cannot be performed within 72 h of collection. Conclusion We successfully optimized the unextracted rRT-PCR process using the Seegene Allplex™ 2019-nCoV assay to detect SARS-CoV-2 RNAs in nasopharyngeal swabs. This improved method offers cost savings and turnaround time advantages compared to automated extraction, with high efficiency of detection that could play an important role in the surveillance of Covid-19.