RETRACTED: The effect of the cortical bone trajectory screw fixation and traditional pedicle screw fixation on surgical site wound infection in posterior lumbar fusion wound: A meta‐analysis
by
Mao, Hanze
,
Li, Qiang
,
Wang, Zhigang
in
cortical bone trajectory screw fixation
,
posterior lumbar fusion
,
surgical site wound infection
2023
A meta‐analysis investigation was performed to measure the influence of cortical bone trajectory screw fixation (CBTSF) and traditional pedicle screw fixation (TPSF) on surgical site wound infection (SSWI) in posterior lumbar fusion (PLF). A comprehensive literature inspection till February 2023 was applied and 1657 interrelated investigations were reviewed. The 13 chosen investigations enclosed 1195 individuals with PLF in the chosen investigations' starting point, 578 of them were using CBTSF, and 617 were using TPSF. Odds ratio (OR) in addition to 95% confidence intervals (CIs) were utilised to compute the value of the effect of the CBTSF and TPSF on SSWI in PLF by the dichotomous approaches and a fixed or random model. No significant difference was found between individuals using CBTSF and TPSF in SSWI (OR, 0.68; 95% CI, 0.35–1.33, P = .26), superficial SSWI (OR, 0.62; 95% CI, 0.22–1.79, P = .38), and deep SSWI (OR, 0.30; 95% CI, 0.06–1.50, P = .14) in PLF. No significant difference was found between individuals using CBTSF and TPSF in SSWI, superficial SSWI, and deep SSWI in PLF. However, care must be exercised when dealing with its values because of the small sample sizes of several chosen investigations for this meta‐analysis and the low number of selected investigations for a certain type of SSWI.
Journal Article
Comparative Biomechanical Analysis of Unilateral, Bilateral, and Lateral Pedicle Screw Implantation in Oblique Lumbar Interbody Fusion: A Finite Element Study
by
Yen, Yu-Chun
,
Su, Kuo-Chih
,
Lee, Cheng-Hung
in
Axial stress
,
Bending
,
bilateral pedicle screw fixation
2023
Oblique lumbar interbody fusion (OLIF) can be combined with different screw instrumentations. The standard screw instrumentation is bilateral pedicle screw fixation (BPSF). However, the operation is time consuming because a lateral recumbent position must be adopted for OLIF during surgery before a prone position is adopted for BPSF. This study aimed to employ a finite element analysis to investigate the biomechanical effects of OLIF combined with BPSF, unilateral pedicle screw fixation (UPSF), or lateral pedicle screw fixation (LPSF). In this study, three lumbar vertebra finite element models for OLIF surgery with three different fixation methods were developed. The finite element models were assigned six loading conditions (flexion, extension, right lateral bending, left lateral bending, right axial rotation, and left axial rotation), and the total deformation and von Mises stress distribution of the finite element models were observed. The study results showed unremarkable differences in total deformation among different groups (the maximum difference range is approximately 0.6248% to 1.3227%), and that flexion has larger total deformation (5.3604 mm to 5.4011 mm). The groups exhibited different endplate stress because of different movements, but these differences were not large (the maximum difference range between each group is approximately 0.455% to 5.0102%). Using UPSF fixation may lead to higher cage stress (411.08 MPa); however, the stress produced on the endplate was comparable to that in the other two groups. Therefore, the length of surgery can be shortened when unilateral back screws are used for UPSF. In addition, the total deformation and endplate stress of UPSF did not differ much from that of BPSF. Hence, combining OLIF with UPSF can save time and enhance stability, which is comparable to a standard BPSF surgery; thus, this method can be considered by spine surgeons.
Journal Article
Percutaneous monoplanar screws versus hybrid fixed axial and polyaxial screws in intermediate screw fixation for traumatic thoracolumbar burst fractures: a case–control study
2024
Background
To compare the clinical and radiological outcomes of monoplanar screws (MSs) versus hybrid fixed axial and polyaxial screws (HSs) in percutaneous short-segment intermediate screw fixation (PSISF) for traumatic thoracolumbar burst fractures (TTBFs) in patients without neurologic impairment.
Methods
A consecutive series of 100 patients with single-segment TTBFs and no neurologic impairment who underwent PSISF with 6 monoplanar screws (MS group) or correct were retrospectively enrolled. The demographic data, radiologic evaluation indicators, perioperative indicators and clinical assessment indicators were analysed between the MS group and HS group.
Results
The demographic data and perioperative indicators were not significantly different in the two groups (
P
> 0.05). The postoperative anterior vertebral height ratio (AVHR), kyphosis Cobb angle (KCA), vertebral wedge angle (VWA) and spinal canal encroachment rate (SCER) were significantly improved in both groups (*
P
< 0.05). The MS group obtained better correction than the HS group in terms of improvement in the AVHR, KCA and VWA after surgery (*
P
< 0.05). At the last follow-up, the MS group had less correction loss of AVHR, KCA and VWA (*
P
< 0.05). The MS group presented greater improvement in the SCER at the last follow-up (*
P
< 0.05). The visual analogue scale (VAS) score and Oswestry Disability Index (ODI) score of all patients were significantly better postoperatively than those preoperatively (*
P
< 0.05), and the scores collected at each follow-up visit did not differ significantly between the two groups (
P
> 0.05). In the MS group, no internal fixation failure was observed during the follow-up period, but, in the HS group, two cases of internal fixation failure were observed at the last follow-up (one case of rod loosening and one case of screw breakage).
Conclusions
Both MSs and HSs fixation are effective treatments for TTBFs and have comparable clinical outcomes. In contrast, MSs fixation can improve the correction effect, better improve the SCER, and further reduce correction loss as well as reduce the incidence of instrumentation failure. Therefore, MSs fixation might be a better option for treating TTBFs in patients without neurological deficits.
Journal Article
Biomechanical insights into anterolateral vertebral screw fixation in osteoporotic spines: a comparative study of fixation methods and positions using porcine vertebrae
by
Hsieh, Ming-Kai
,
Chen, Weng-Pin
,
Li, Yun-Da
in
Animals
,
Anterolateral vertebral screw fixation
,
Bicortical and unicortical screw fixation
2025
Objective
Combining oblique lumbar interbody fusion (OLIF) with posterior pedicle screw fixation (PPSF) has been proposed to reduce cage subsidence, especially in osteoporotic spines. Recently, anterolateral screw-rod fixation has gained interest as it allows direct pathology observation and avoids a posterior approach. However, controversies exist between anterolateral screw fixation systems and traditional PPSF due to variations in osteoporotic vertebral mineral density, screw fixation positions, and fixation methods (bicortical vs. unicortical). This study aimed to investigate the biomechanical impact of fixation position and method in osteoporotic spine.
Methods
Seventy-two fresh‑frozen porcine vertebrae (L1–6) were decalcified using 0.5 M EDTA and divided into two groups based on fixation method: bicortical or unicortical. Six groups for each method were created according to the screw position in the lateral vertebral body, with six specimens in each group: anterior, central, and posterior in the middle body and para-endplate regions. Correlations among screw position, fixation method and axial pullout strength were analyzed.
Results
A 4-week decalcification process, bone mineral density in the porcine vertebrae decreased to approximately 48% (
p
< 0.05) of the original value, categorizing them as osteoporotic. Bicortical fixation showed significantly greater pullout forces than unicortical fixation, with differences ranging from 82 to 273%. Notably, central or posterior screws outperformed anterior screws in pullout strength.
Conclusion
Bicortical fixation exhibited significantly greater pullout forces than unicortical fixation. We suggest positioning screws in the central or posterior region of the middle body with bicortical fixation in osteoporotic vertebrae.
Journal Article
Screw fixation of ACPHT acetabular fractures offers sufficient biomechanical stability when compared to standard buttress plate fixation
by
Cinelli, Paolo
,
Pfeifer, Roman
,
Osterhoff, Georg
in
Acetabular fracture
,
Acetabulum
,
Acetabulum - injuries
2019
Background
Geriatric acetabular fractures require fixation with sufficient primary stability to allow for immediate full-weight bearing. Minimally-invasive procedures would be desirable in order to keep perioperative morbidity low. The purpose of this study was to compare the biomechanical strength of lag screw-only fixation of anterior column posterior hemi-transverse (ACPHT) acetabular fractures to standard anatomical plate fixation.
Methods
Standardized ACPHT fractures were created in fourth generation synthetic pelvis models and stabilized by either an anatomical buttress plate (
n
= 4) or by a screw-only construct (n = 4). In a validated setup, a cyclic loading protocol was applied with increasing axial force (3200 cycles, 175 N to 2250 N). Construct survival, acetabular fracture motion, and mode of failure were assessed.
Results
The median number of cycles needed until failure of the construct occurred was 2304 cycles (range, 2020 to 2675) in the plate fixation group and 3200 cycles (range, 3101 to 3200) for the screw fixation constructs (
p
= .003). With regard to energy absorbed until failure, the plate fixation group resisted to 1.57 × 10
6
N*cycles (range, 1.21 × 10
6
to 2.14 × 10
6
) and the screw fixation group to 3.17 × 10
6
N*cycles (range, 2.92 × 10
6
to 3.17 × 10
6
;
p
= .001). All plate fixation specimens failed with a break-out of the posterior-column screw in the quadrilateral wing of the anatomical plate within a maximum load of 1750 N while the screw fixation constructs all survived loading of at least 2100 N. Acetabular fracture gap motion, acetabular rim angle, and medial femoral head subluxation as measures of fracture displacement were all not different between the two groups (
p
> 0.1).
Conclusions
In this in vitro biomechanical study, screw-only fixation of an ACPHT acetabular fracture resulted in at least as good construct survival as seen for standard buttress plate fixation. Both methods resisted sufficiently to forces that would be expected under physiologic conditions.
Journal Article
Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement
2019
Objective To compare the superior‐level facet joint violations (FJV) between robot‐assisted (RA) percutaneous pedicle screw placement and conventional open fluoroscopic‐guided (FG) pedicle screw placement in a prospective cohort study. Methods This was a prospective cohort study without randomization. One‐hundred patients scheduled to undergo RA (n = 50) or FG (n = 50) transforaminal lumbar interbody fusion were included from February 2016 to May 2018. The grade of FJV, the distance between pedicle screws and the corresponding proximal facet joint, and intra‐pedicle accuracy of the top screw were evaluated based on postoperative CT scan. Patient demographics, perioperative outcomes, and radiation exposure were recorded and compared. Perioperative outcomes include surgical time, intraoperative blood loss, postoperative length of stay, conversion, and revision surgeries. Results Of the 100 screws in the RA group, 4 violated the proximal facet joint, while 26 of 100 in the FG group had FJV (P = 0.000). In the RA group, 3 and 1 screws were classified as grade 1 and 2, respectively. Of the 26 FJV screws in the FG group, 17 screws were scored as grade 1, 6 screws were grade 2, and 3 screws were grade 3. Significantly more severe FJV were noted in the FG group than in the RA group (P = 0.000). There was a statistically significant difference between RA and FG for overall violation grade (0.05 vs 0.38, P = 0.000). The average distance of pedicle screws from facet joints in the RA group (4.16 ± 2.60 mm) was larger than that in the FG group (1.92 ± 1.55 mm; P = 0.000). For intra‐pedicle accuracy, the rate of perfect screw position was greater in the RA group than in the FG group (85% vs 71%; P = 0.017). No statistically significant difference was found between the clinically acceptable screws between groups (P = 0.279). The radiation dose was higher in the FG group (30.3 ± 11.3 vs 65.3 ± 28.3 μSv; P = 0.000). The operative time in the RA group was significantly longer (184.7 ± 54.3 vs 117.8 ± 36.9 min; P = 0.000). Conclusions Compared to the open FG technique, minimally invasive RA spine surgery was associated with fewer proximal facet joint violations, larger facet to screw distance, and higher intra‐pedicle accuracy.
Journal Article
Biomechanical comparison of different screw-included angles in crossing screw fixation for transverse patellar fracture in level walking: a quasi-dynamic finite element study
by
Chen, Yen-Nien
,
Chang, Hung-Chih
,
Chang, Chih-Wei
in
Analysis
,
Biomechanical Phenomena
,
Bone Screws
2023
Background
A minimally invasive technique with various screw configurations without open surgery is currently used for the fixation of transverse patellar fractures. Percutaneous crossing screw configuration has been reported to have a good bone union rate in patellar fractures. However, the difference in mechanical stability of the fractured patella between different screw-included angles has not been fully investigated. Hence, this study aims to compare the mechanical stability of parallel and crossing screw fixations with different screw-included angles for the fixation of transverse patellar fractures during level walking.
Methods
A finite element knee model containing a patella with a transverse fracture is created. Two headless compression screws with different angles (0°, 30°, 60°, and 90°) are used to fix the fracture. The loading conditions of the knee joint during level walking are used to compare the stability of the fractured patella with different fixation screw configurations.
Results
The results indicate that the maximum fracture gap opening distance increased with an increase in the included angle. Two parallel screws yield the smallest gap distance among all screw configurations. The maximum gap opening distances at the anterior leading edge of the fractured patella with two parallel screws and two screws having an included angle of 90° are 0.73 mm and 1.31 mm, respectively, at 15% walking cycle.
Conclusions
Based on these results, the superior performance of two parallel screws over crossing screw fixations in the fixation of transverse patellar fractures is established. Furthermore, the smaller the angle between the crossing screws, the better is the stability of the fractured patella.
Journal Article
The biomechanical study of different fixation techniques for combination fractures of atlas and axis: a finite element analysis
2025
Combination atlas–axis fractures are less studied but relatively common with a higher incidence of neurological deficits than isolated C1 or C2 fractures. Several authors focused on the treatment strategies, but there is no study to compare the stability of different fixation methods; neither not yet clear which technique represents the best choice and whether stabilization devices can be efficient and beneficial for complex atlantoaxial fractures. The aim of this study was to compare the biomechanical properties of three fixation techniques: atlantoaxial pedicle screws fixation (PSF), occipital–cervical fusion (OCF) and transarticular screw fixation (TSF) based on combination factures model. Our results showed the range of motion (ROM) of fracture model increased obviously than intact model. The ROM in flexion/extension and rotation of C0–C1 in PSF and TSF models were increased. The ROM of C1–C2 in all conditions in PSF, OCF and TSF models were decreased. The ROM of C2–C3 was decreased in OCF, but remains the same stage in PSF and TSF. These suggested that three surgical methods are effective for the combination fractures of atlas and axis, which can ensure good stability. It can properly increase the ROM of C0–C1 when using PSF. These findings would aid in the treatment of this complex fractures.
Journal Article
Hidden blood loss between percutaneous pedicle screw fixation and the mini-open Wiltse approach with pedicle screw fixation for neurologically intact thoracolumbar fractures: a retrospective study
2023
Background
The aim of this study was to determine the proportion of hidden blood loss (HBL) in patients treated with minimally invasive surgery, and to compare the HBL between patients treated with percutaneous pedicle screw fixation (PPSF) and the mini-open Wiltse approach with pedicle screw fixation (MWPSF).
Methods
From January 2017 to January 2019, a total of 119 patients with thoracolumbar fractures were included in the analysis, of which 58 cases received PPSF and 61 cases received MWPSF. The clinical information and demographic results were collected and compared. And the HBL of the patients is calculated by the combination formulas of Nadler, Gross and Sehat.
Results
Compared with the PPSF group, operation time of MWPSF is shorter. The fluoroscopy times are 13.6 ± 3.0 in PPSF group and 5.6 ± 1.6 in MWPSF group (
p
< 0.001). As shown in Table
3
, the intraoperative blood loss in PPSF group is 31.9 ± 9.6 ml, which is significantly less than that in the MWPSF group (44.0 ± 14.9 ml). The HBL (445.7 ± 228.9 ml), and HBL% (91.2 ± 7.7%) of the PPSF group are significantly higher than that in the MWPSF group (
P
< 0.05). And the total blood loss (TBL) of the PPSF group (477.6 ± 228.8 ml) is also more than that in the MWPSF group (401.0 ± 171.3 ml).
Conclusions
Our results suggest that in the minimally invasive surgical treatment of thoracolumbar fractures, the perioperative HBL is much higher than visible blood loss (VBL). Although PPSF has less intraoperative blood loss, it has higher TBL and HBL than those of MWPSF. Compared with MWPSF, we should pay more attention to the postoperative anemia status of patients with thoracolumbar fractures undergoing PPSF surgery.
Journal Article