Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
39,514 result(s) for "Signal-to-noise"
Sort by:
High-capacity free-space optical communications using wavelength- and mode-division-multiplexing in the mid-infrared region
Due to its absorption properties in atmosphere, the mid-infrared (mid-IR) region has gained interest for its potential to provide high data capacity in free-space optical (FSO) communications. Here, we experimentally demonstrate wavelength-division-multiplexing (WDM) and mode-division-multiplexing (MDM) in a ~0.5 m mid-IR FSO link. We multiplex three ~3.4 μm wavelengths (3.396 μm, 3.397 μm, and 3.398 μm) on a single polarization, with each wavelength carrying two orbital-angular-momentum (OAM) beams. As each beam carries 50-Gbit/s quadrature-phase-shift-keying data, a total capacity of 300 Gbit/s is achieved. The WDM channels are generated and detected in the near-IR (C-band). They are converted to mid-IR and converted back to C-band through the difference frequency generation nonlinear processes. We estimate that the system penalties at a bit error rate near the forward error correction threshold include the following: (i) the wavelength conversions induce ~2 dB optical signal-to-noise ratio (OSNR) penalty, (ii) WDM induces ~1 dB OSNR penalty, and (iii) MDM induces ~0.5 dB OSNR penalty. These results show the potential of using multiplexing to achieve a ~30X increase in data capacity for a mid-IR FSO link. A 300-Gbit/s free-space optical communication system is demonstrated in the mid-IR wavelength region by using both wavelength- and mode-division multiplexing.
Comparing Recent Pulsar Timing Array Results on the Nanohertz Stochastic Gravitational-wave Background
The Australian, Chinese, European, Indian, and North American pulsar timing array (PTA) collaborations recently reported, at varying levels, evidence for the presence of a nanohertz gravitational-wave background (GWB). Given that each PTA made different choices in modeling their data, we perform a comparison of the GWB and individual pulsar noise parameters across the results reported from the PTAs that constitute the International Pulsar Timing Array (IPTA). We show that despite making different modeling choices, there is no significant difference in the GWB parameters that are measured by the different PTAs, agreeing within 1σ. The pulsar noise parameters are also consistent between different PTAs for the majority of the pulsars included in these analyses. We bridge the differences in modeling choices by adopting a standardized noise model for all pulsars and PTAs, finding that under this model there is a reduction in the tension in the pulsar noise parameters. As part of this reanalysis, we “extended” each PTA’s data set by adding extra pulsars that were not timed by that PTA. Under these extensions, we find better constraints on the GWB amplitude and a higher signal-to-noise ratio for the Hellings–Downs correlations. These extensions serve as a prelude to the benefits offered by a full combination of data across all pulsars in the IPTA, i.e., the IPTA’s Data Release 3, which will involve not just adding in additional pulsars but also including data from all three PTAs where any given pulsar is timed by more than a single PTA.
Next-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla
To increase granularity in human neuroimaging science, we designed and built a next-generation 7 Tesla magnetic resonance imaging scanner to reach ultra-high resolution by implementing several advances in hardware. To improve spatial encoding and increase the image signal-to-noise ratio, we developed a head-only asymmetric gradient coil (200 mT m −1 , 900 T m −1 s −1 ) with an additional third layer of windings. We integrated a 128-channel receiver system with 64- and 96-channel receiver coil arrays to boost signal in the cerebral cortex while reducing g-factor noise to enable higher accelerations. A 16-channel transmit system reduced power deposition and improved image uniformity. The scanner routinely performs functional imaging studies at 0.35–0.45 mm isotropic spatial resolution to reveal cortical layer functional activity, achieves high angular resolution in diffusion imaging and reduces acquisition time for both functional and structural imaging. A combination of hardware developments has increased the achievable spatial resolution in 7 Tesla human neuroimaging to about 0.4 mm.
Transformer noise removal method based on IMGO-CEEMD
This paper conducts an experimental study on the noise filtering of transformer voiceprint signals. The results show that the proposed method has increased the signal-to-noise ratio of the noise by 2.2 to 3.5 decibels, and reduced the root mean square error by 8% to 25%. Therefore, this method can consistently improve the denoising effect in complex noise environments and provide an effective foundation for high-precision voiceprint recognition.
Quantum-enhanced nonlinear microscopy
The performance of light microscopes is limited by the stochastic nature of light, which exists in discrete packets of energy known as photons. Randomness in the times that photons are detected introduces shot noise, which fundamentally constrains sensitivity, resolution and speed 1 . Although the long-established solution to this problem is to increase the intensity of the illumination light, this is not always possible when investigating living systems, because bright lasers can severely disturb biological processes 2 – 4 . Theory predicts that biological imaging may be improved without increasing light intensity by using quantum photon correlations 1 , 5 . Here we experimentally show that quantum correlations allow a signal-to-noise ratio beyond the photodamage limit of conventional microscopy. Our microscope is a coherent Raman microscope that offers subwavelength resolution and incorporates bright quantum correlated illumination. The correlations allow imaging of molecular bonds within a cell with a 35 per cent improved signal-to-noise ratio compared with conventional microscopy, corresponding to a 14 per cent improvement in concentration sensitivity. This enables the observation of biological structures that would not otherwise be resolved. Coherent Raman microscopes allow highly selective biomolecular fingerprinting in unlabelled specimens 6 , 7 , but photodamage is a major roadblock for many applications 8 , 9 . By showing that the photodamage limit can be overcome, our work will enable order-of-magnitude improvements in the signal-to-noise ratio and the imaging speed. A quantum microscope obtains signal-to-noise beyond the photodamage limits of conventional microscopy, revealing biological structures within cells that would not otherwise be resolved.
Research Progress in Distributed Acoustic Sensing Techniques
Distributed acoustic sensing techniques based on Rayleigh scattering have been widely used in many applications due to their unique advantages, such as long-distance detection, high spatial resolution, and wide sensing bandwidth. In this paper, we provide a review of the recent advancements in distributed acoustic sensing techniques. The research progress and operation principles are systematically reviewed. The pivotal technologies and solutions applied to distributed acoustic sensing are introduced in terms of polarization fading, coherent fading, spatial resolution, frequency response, signal-to-noise ratio, and sensing distance. The applications of the distributed acoustic sensing are covered, including perimeter security, earthquake monitoring, energy exploration, underwater positioning, and railway monitoring. The potential developments of the distributed acoustic sensing techniques are also discussed.
A signal-processing-based interpretation of the Nash–Sutcliffe efficiency
The Nash–Sutcliffe efficiency (NSE) is a widely used score in hydrology, but it is not common in the other environmental sciences. One of the reasons for its unpopularity is that its scientific meaning is somehow unclear in the literature. This study attempts to establish a solid foundation for the NSE from the viewpoint of signal progressing. Thus, a simulation is viewed as a received signal containing a wanted signal (observations) contaminated by an unwanted signal (noise). This view underlines an important role of the error model between simulations and observations. By assuming an additive error model, it is easy to point out that the NSE is equivalent to an important quantity in signal processing: the signal-to-noise ratio. Moreover, the NSE and the Kling–Gupta efficiency (KGE) are shown to be equivalent, at least when there are no biases, in the sense that they measure the relative magnitude of the power of noise to the power of the variation in observations. The scientific meaning of the NSE suggests a natural way to define NSE=0 as the threshold for good or bad model distinction, and this has no relation to the benchmark simulation that is equal to the observed mean. Corresponding to NSE=0, the threshold of the KGE is given by approximately 0.5. In the general cases, when the additive error model is replaced by a mixed additive–multiplicative error model, the traditional NSE is shown to be prone to contradiction in model evaluations. Therefore, an extension of the NSE is derived, which only requires one to divide the traditional noise-to-signal ratio by the multiplicative bias. This has a practical implication: if the multiplicative bias is not considered, the traditional NSE and KGE underestimate or overestimate the generalized NSE and KGE when the multiplicative bias is greater or smaller than one, respectively. In particular, the observed mean turns out to be the worst simulation from the viewpoint of the generalized NSE.
Aircraft Target Detection in Low Signal-to-Noise Ratio Visible Remote Sensing Images
With the increasing demand for the wide-area refined detection of aircraft targets, remote sensing cameras have adopted an ultra-large area-array detector as a new imaging mode to obtain broad width remote sensing images (RSIs) with higher resolution. However, this imaging technology introduces new special image degradation characteristics, especially the weak target energy and the low signal-to-noise ratio (SNR) of the image, which seriously affect the target detection capability. To address the aforementioned issues, we propose an aircraft detection method for RSIs with low SNR, termed L-SNR-YOLO. In particular, the backbone is built blending a swin-transformer and convolutional neural network (CNN), which obtains multiscale global and local RSI information to enhance the algorithm’s robustness. Moreover, we design an effective feature enhancement (EFE) block integrating the concept of nonlocal means filtering to make the aircraft features significant. In addition, we utilize a novel loss function to optimize the detection accuracy. The experimental results demonstrate that our L-SNR-YOLO achieves better detection performance in RSIs than several existing advanced methods.
Transcranial volumetric imaging using a conformal ultrasound patch
Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow 1 , but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording 2 . Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as −1.51 ± 4.34 cm s −1 , −0.84 ± 3.06 cm s −1 and −0.50 ± 2.55 cm s −1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording. A conformal ultrasound patch can be used for hands-free volumetric imaging and continuous monitoring of cerebral blood flow
Real-time denoising enables high-sensitivity fluorescence time-lapse imaging beyond the shot-noise limit
A fundamental challenge in fluorescence microscopy is the photon shot noise arising from the inevitable stochasticity of photon detection. Noise increases measurement uncertainty and limits imaging resolution, speed and sensitivity. To achieve high-sensitivity fluorescence imaging beyond the shot-noise limit, we present DeepCAD-RT, a self-supervised deep learning method for real-time noise suppression. Based on our previous framework DeepCAD, we reduced the number of network parameters by 94%, memory consumption by 27-fold and processing time by a factor of 20, allowing real-time processing on a two-photon microscope. A high imaging signal-to-noise ratio can be acquired with tenfold fewer photons than in standard imaging approaches. We demonstrate the utility of DeepCAD-RT in a series of photon-limited experiments, including in vivo calcium imaging of mice, zebrafish larva and fruit flies, recording of three-dimensional (3D) migration of neutrophils after acute brain injury and imaging of 3D dynamics of cortical ATP release. DeepCAD-RT will facilitate the morphological and functional interrogation of biological dynamics with a minimal photon budget. DeepCAD-RT denoises fluorescence time-lapse images in real time.