Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
1,318 result(s) for "Single Molecule Imaging"
Sort by:
Direct single-molecule detection and super-resolution imaging with a low-cost portable smartphone-based microscope
Detecting single molecules, which represents the ultimate level of sensitivity, is typically achieved with research-grade equipment. Here we present a low-cost, portable smartphone-based fluorescence microscope capable of detecting single-molecule fluorescence directly, i.e., without the need for any signal amplification. The setup leverages the image sensors and data handling capacity of mass-produced smartphones, it is adaptable to different smartphones and capable of detecting single molecules across the visible spectral range. We showcase this capability through single-molecule measurements on DNA origami models and super-resolution microscopy of cells by single-molecule localization microscopy. Last, we illustrate its potential as a point-of-care (POC) device by implementing a single-molecule bioassay for RNA detection. This development paves the way for innovative applications of massively distributed or personalized assays with single-molecule sensitivity in various fields such as digital bioassays, POC diagnostics, field expeditions, STEM outreach, and life science education. Loretan and colleagues present a low-cost smartphone-based microscope capable of detecting single-molecule fluorescence. This approach opens doors to personalised and widely distributed applications in diagnostics, biosensing, and science education.
Comparative Analysis of Single-Molecule Dynamics of TRPV1 and TRPV4 Channels in Living Cells
TRPV1 and TRPV4, members of the transient receptor potential vanilloid family, are multimodal ion channels activated by various stimuli, including temperature and chemicals. It has been demonstrated that TRPV channels function as tetramers; however, the dynamics of the diffusion, oligomerization, and endocytosis of these channels in living cells are unclear. Here we undertook single-molecule time-lapse imaging of TRPV1 and TRPV4 in HEK 293 cells. Differences were observed between TRPV1 and TRPV4 before and after agonist stimulation. In the resting state, TRPV4 was more likely to form higher-order oligomers within immobile membrane domains than TRPV1. TRPV1 became immobile after capsaicin stimulation, followed by its gradual endocytosis. In contrast, TRPV4 was rapidly internalized upon stimulation with GSK1016790A. The selective loss of immobile higher-order oligomers from the cell surface through endocytosis increased the proportion of the fast-diffusing state for both subtypes. With the increase in the fast state, the association rate constants of TRPV1 and TRPV4 increased, regenerating the higher-order oligomers. Our results provide a possible mechanism for the different rates of endocytosis of TRPV1 and TRPV4 based on the spatial organization of the higher-order structures of the two TRPV channels.
Single-particle cryo-EM—How did it get here and where will it go
Cryo–electron microscopy, or simply cryo-EM, refers mainly to three very different yet closely related techniques: electron crystallography, single-particle cryo-EM, and electron cryotomography. In the past few years, single-particle cryo-EM in particular has triggered a revolution in structural biology and has become a newly dominant discipline. This Review examines the fascinating story of its start and evolution over the past 40-plus years, delves into how and why the recent technological advances have been so groundbreaking, and briefly considers where the technique may be headed in the future.
FRET-based dynamic structural biology: Challenges, perspectives and an appeal for open-science practices
Single-molecule FRET (smFRET) has become a mainstream technique for studying biomolecular structural dynamics. The rapid and wide adoption of smFRET experiments by an ever-increasing number of groups has generated significant progress in sample preparation, measurement procedures, data analysis, algorithms and documentation. Several labs that employ smFRET approaches have joined forces to inform the smFRET community about streamlining how to perform experiments and analyze results for obtaining quantitative information on biomolecular structure and dynamics. The recent efforts include blind tests to assess the accuracy and the precision of smFRET experiments among different labs using various procedures. These multi-lab studies have led to the development of smFRET procedures and documentation, which are important when submitting entries into the archiving system for integrative structure models, PDB-Dev. This position paper describes the current ‘state of the art’ from different perspectives, points to unresolved methodological issues for quantitative structural studies, provides a set of ‘soft recommendations’ about which an emerging consensus exists, and lists openly available resources for newcomers and seasoned practitioners. To make further progress, we strongly encourage ‘open science’ practices.
Single-particle cryo-EM at atomic resolution
The three-dimensional positions of atoms in protein molecules define their structure and their roles in biological processes. The more precisely atomic coordinates are determined, the more chemical information can be derived and the more mechanistic insights into protein function may be inferred. Electron cryo-microscopy (cryo-EM) single-particle analysis has yielded protein structures with increasing levels of detail in recent years 1 , 2 . However, it has proved difficult to obtain cryo-EM reconstructions with sufficient resolution to visualize individual atoms in proteins. Here we use a new electron source, energy filter and camera to obtain a 1.7 Å resolution cryo-EM reconstruction for a human membrane protein, the β3 GABA A receptor homopentamer 3 . Such maps allow a detailed understanding of small-molecule coordination, visualization of solvent molecules and alternative conformations for multiple amino acids, and unambiguous building of ordered acidic side chains and glycans. Applied to mouse apoferritin, our strategy led to a 1.22 Å resolution reconstruction that offers a genuine atomic-resolution view of a protein molecule using single-particle cryo-EM. Moreover, the scattering potential from many hydrogen atoms can be visualized in difference maps, allowing a direct analysis of hydrogen-bonding networks. Our technological advances, combined with further approaches to accelerate data acquisition and improve sample quality, provide a route towards routine application of cryo-EM in high-throughput screening of small molecule modulators and structure-based drug discovery. Advances in electron cryo-microscopy hardware allow proteins to be studied at atomic resolution.
Toward dynamic structural biology: Two decades of single-molecule Förster resonance energy transfer
Structural techniques such as x-ray crystallography and electron microscopy give insight into how macromolecules function by providing snapshots of different conformational states. Function also depends on the path between those states, but to see that path involves watching single molecules move. This became possible with the advent of single-molecule Förster resonance energy transfer (smFRET), which was first implemented in 1996. Lerner et al. review how smFRET has been used to study macromolecules in action, providing mechanistic insights into processes such as DNA repair, transcription, and translation. They also describe current limitations of the approach and suggest how future developments may expand the applications of smFRET. Science , this issue p. eaan1133 Classical structural biology can only provide static snapshots of biomacromolecules. Single-molecule Förster resonance energy transfer (smFRET) paved the way for studying dynamics in macromolecular structures under biologically relevant conditions. Since its first implementation in 1996, smFRET experiments have confirmed previously hypothesized mechanisms and provided new insights into many fundamental biological processes, such as DNA maintenance and repair, transcription, translation, and membrane transport. We review 22 years of contributions of smFRET to our understanding of basic mechanisms in biochemistry, molecular biology, and structural biology. Additionally, building on current state-of-the-art implementations of smFRET, we highlight possible future directions for smFRET in applications such as biosensing, high-throughput screening, and molecular diagnostics.
Rapid SARS-CoV-2 Detection Using Electrochemical Immunosensor
The outbreak of the coronavirus disease (COVID-19) pandemic caused by the novel coronavirus (SARS-CoV-2) has been declared an international public health crisis. It is essential to develop diagnostic tests that can quickly identify infected individuals to limit the spread of the virus and assign treatment options. Herein, we report a proof-of-concept label-free electrochemical immunoassay for the rapid detection of SARS-CoV-2 virus via the spike surface protein. The assay consists of a graphene working electrode functionalized with anti-spike antibodies. The concept of the immunosensor is to detect the signal perturbation obtained from ferri/ferrocyanide measurements after binding of the antigen during 45 min of incubation with a sample. The absolute change in the [Fe(CN)6]3−/4− current upon increasing antigen concentrations on the immunosensor surface was used to determine the detection range of the spike protein. The sensor was able to detect a specific signal above 260 nM (20 µg/mL) of subunit 1 of recombinant spike protein. Additionally, it was able to detect SARS-CoV-2 at a concentration of 5.5 × 105 PFU/mL, which is within the physiologically relevant concentration range. The novel immunosensor has a significantly faster analysis time than the standard qPCR and is operated by a portable device which can enable on-site diagnosis of infection.
3D single-molecule super-resolution microscopy with a tilted light sheet
Tilted light sheet microscopy with 3D point spread functions (TILT3D) combines a novel, tilted light sheet illumination strategy with long axial range point spread functions (PSFs) for low-background, 3D super-localization of single molecules as well as 3D super-resolution imaging in thick cells. Because the axial positions of the single emitters are encoded in the shape of each single-molecule image rather than in the position or thickness of the light sheet, the light sheet need not be extremely thin. TILT3D is built upon a standard inverted microscope and has minimal custom parts. The result is simple and flexible 3D super-resolution imaging with tens of nm localization precision throughout thick mammalian cells. We validate TILT3D for 3D super-resolution imaging in mammalian cells by imaging mitochondria and the full nuclear lamina using the double-helix PSF for single-molecule detection and the recently developed tetrapod PSFs for fiducial bead tracking and live axial drift correction. Light-sheet single-molecule 3D super-resolution microscopes can’t image close to a coverslip or may require complex apparatus. Here the authors overcome such limitations using a tilted light sheet strategy with long axial range point spread functions on a standard inverted microscope.
Multiplex chromatin interactions with single-molecule precision
The genomes of multicellular organisms are extensively folded into 3D chromosome territories within the nucleus 1 . Advanced 3D genome-mapping methods that combine proximity ligation and high-throughput sequencing (such as chromosome conformation capture, Hi-C) 2 , and chromatin immunoprecipitation techniques (such as chromatin interaction analysis by paired-end tag sequencing, ChIA-PET) 3 , have revealed topologically associating domains 4 with frequent chromatin contacts, and have identified chromatin loops mediated by specific protein factors for insulation and regulation of transcription 5 – 7 . However, these methods rely on pairwise proximity ligation and reflect population-level views, and thus cannot reveal the detailed nature of chromatin interactions. Although single-cell Hi-C 8 potentially overcomes this issue, this method may be limited by the sparsity of data that is inherent to current single-cell assays. Recent advances in microfluidics have opened opportunities for droplet-based genomic analysis 9 but this approach has not yet been adapted for chromatin interaction analysis. Here we describe a strategy for multiplex chromatin-interaction analysis via droplet-based and barcode-linked sequencing, which we name ChIA-Drop. We demonstrate the robustness of ChIA-Drop in capturing complex chromatin interactions with single-molecule precision, which has not been possible using methods based on population-level pairwise contacts. By applying ChIA-Drop to Drosophila cells, we show that chromatin topological structures predominantly consist of multiplex chromatin interactions with high heterogeneity; ChIA-Drop also reveals promoter-centred multivalent interactions, which provide topological insights into transcription. A strategy using droplet-based and barcode-linked sequencing captures multiplex chromatin interactions at single-molecule precision, and here provides topological insight into chromatin structures and transcription in Drosophila .
Diagnostic Potential of Imaging Flow Cytometry
Imaging flow cytometry (IFC) captures multichannel images of hundreds of thousands of single cells within minutes. IFC is seeing a paradigm shift from low- to high-information-content analysis, driven partly by deep learning algorithms. We predict a wealth of applications with potential translation into clinical practice.