Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Series Title
      Series Title
      Clear All
      Series Title
  • Reading Level
      Reading Level
      Clear All
      Reading Level
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Content Type
    • Item Type
    • Is Full-Text Available
    • Subject
    • Country Of Publication
    • Publisher
    • Source
    • Target Audience
    • Donor
    • Language
    • Place of Publication
    • Contributors
    • Location
81,685 result(s) for "Solution (Chemistry)"
Sort by:
Examining mixtures & solutions
This book provides young readers with an overview of mixtures and solutions. The text includes a simple overview of mixtures and solutions and examines homogeneous and heterogeneous mixtures, suspensions and colloids, solubility, saturation, and concentration. Information is explained using real-world examples and supported with graphics and photos.
Restrictive versus Liberal Fluid Therapy for Major Abdominal Surgery
Patients undergoing major abdominal surgery received restrictive or liberal intravenous fluids during surgery and up to 24 hours thereafter. The restrictive regimen did not improve disability-free survival and resulted in increased acute kidney injury.
Population-based volume kinetics of crystalloids and colloids in healthy volunteers
We characterized the volume kinetics of crystalloid solutions (Ringer’s lactate solution and 5% dextrose water) and colloid solutions (6% tetrastarch and 10% pentastarch) by nonlinear mixed-effects modeling in healthy volunteers. We also assessed whether the bioelectrical impedance analysis parameters are significant covariates for volume kinetic parameters. Twelve male volunteers were randomly allocated to four groups, and each group received the four fluid solutions in specified sequences, separated by 1-week intervals to avoid any carryover effects. Volunteers received 40 ml/kg Ringer’s lactate solution, 20 ml/kg 5% dextrose water, 1000 ml 6% tetrastarch, and 1000 ml 10% pentastarch over 1 h. Arterial blood samples were collected to measure the hemoglobin concentration at different time points. Bioelectrical impedance spectroscopy (BIS, INBODY S10, InBody CO., LTD, Seoul, Korea) was also carried out at preset time points. In total, 671 hemoglobin-derived plasma dilution data points were used to determine the volume kinetic characteristics of each fluid. The changes in plasma dilution induced by administration of crystalloid and colloid solutions were well-described by the two-volume and one-volume models, respectively. Extracellular water was a significant covariate for the peripheral volume of distribution at baseline in the volume kinetic model of Ringer’s lactate solution. When the same amount was administered, the colloid solutions had ~4 times more plasma expansion effect than did the crystalloid solutions. Starches with larger molecular weights maintained the volume expansion effect longer than those with smaller molecular weights.
A Primer on Experiments with Mixtures
The concise yet authoritative presentation of key techniques for basic mixtures experiments Inspired by the author's bestselling advanced book on the topic, A Primer on Experiments with Mixtures provides an introductory presentation of the key principles behind experimenting with mixtures. Outlining useful techniques through an applied approach with examples from real research situations, the book supplies a comprehensive discussion of how to design and set up basic mixture experiments, then analyze the data and draw inferences from results. Drawing from his extensive experience teaching the topic at various levels, the author presents the mixture experiments in an easy-to-follow manner that is void of unnecessary formulas and theory. Succinct presentations explore key methods and techniques for carrying out basic mixture experiments, including: * Designs and models for exploring the entire simplex factor space, with coverage of simplex-lattice and simplex-centroid designs, canonical polynomials, the plotting of individual residuals, and axial designs * Multiple constraints on the component proportions in the form of lower and/or upper bounds, introducing L-Pseudocomponents, multicomponent constraints, and multiple lattice designs for major and minor component classifications * Techniques for analyzing mixture data such as model reduction and screening components, as well as additional topics such as measuring the leverage of certain design points * Models containing ratios of the components, Cox's mixture polynomials, and the fitting of a slack variable model * A review of least squares and the analysis of variance for fitting data Each chapter concludes with a summary and appendices with details on the technical aspects of the material. Throughout the book, exercise sets with selected answers allow readers to test their comprehension of the material, and References and Recommended Reading sections outline further resources for study of the presented topics. A Primer on Experiments with Mixtures is an excellent book for one-semester courses on mixture designs and can also serve as a supplement for design of experiments courses at the upper-undergraduate and graduate levels. It is also a suitable reference for practitioners and researchers who have an interest in experiments with mixtures and would like to learn more about the related mixture designs and models.
Clinical Trial of Fluid Infusion Rates for Pediatric Diabetic Ketoacidosis
Diabetic ketoacidosis in children may cause brain injury. In this randomized, controlled trial, neither the rate of administration nor the sodium chloride content of intravenous fluids significantly influenced neurologic outcomes in children with diabetic ketoacidosis.
Influence of salt solution on the physicochemical properties and in vitro/ in vivo expression of mRNA/LNP
Lipid nanoparticles (LNPs) have revolutionized nucleic acid delivery, enabling significant advances in mRNA-based therapeutics. While extensive research has focused on lipid composition, the impact of preparation solutions on LNP performance remains underexplored. This study systematically investigated the effects of pH, salt type, and concentration across key preparation solutions—mRNA aqueous, dilution, exchange, and storage solutions—on the physicochemical properties, stability, and expression efficiency of SM102-based mRNA/LNPs. Findings revealed that the pH of the mRNA aqueous solution was critical, with a pH of 4 optimizing encapsulation efficiency (EE) and cellular expression. The exchange solution’s pH significantly influenced biodistribution, particularly liver-specific expression following intravenous and intramuscular administration. Sucrose was identified as essential for freeze-thaw stability, with a 300 mM concentration minimizing aggregation and mRNA leakage. Furthermore, preparation solutions were shown to influence the structural integrity of LNPs, impacting their in vivo and in vitro performance. These insights highlight the importance of preparation conditions in optimizing LNP formulations for clinical applications, offering a foundation for enhanced therapeutic design and delivery.
Replica Exchange with Solute Tempering: A Method for Sampling Biological Systems in Explicit Water
An innovative replica exchange (parallel tempering) method called replica exchange with solute tempering (REST) for the efficient sampling of aqueous protein solutions is presented here. The method bypasses the poor scaling with system size of standard replica exchange and thus reduces the number of replicas (parallel processes) that must be used. This reduction is accomplished by deforming the Hamiltonian function for each replica in such a way that the acceptance probability for the exchange of replica configurations does not depend on the number of explicit water molecules in the system. For proof of concept, REST is compared with standard replica exchange for an alanine dipeptide molecule in water. The comparisons confirm that REST greatly reduces the number of CPUs required by regular replica exchange and increases the sampling efficiency. This method reduces the CPU time required for calculating thermodynamic averages and for the ab initio folding of proteins in explicit water.
Differences in Soil Solution Chemistry and Their Vertical Variation Between Moso Bamboo Forests and Japanese Cedar Plantations in Western Japan
Bamboo invasion into adjacent forests highlights the need to clarify its ecological impacts, particularly on soil solution chemistry, which influences forest nutrient availability and downstream water quality. This study examined how bamboo invasion alters base cations and anion concentrations, their vertical distribution, and the distinct ionic compositions maintaining charge balance in soil solution by comparing Moso bamboo (BF) and adjacent Japanese cedar (CF) forests. In surface soil solution (5 cm), most ion concentrations were significantly higher in CF than in BF, likely attributable to a greater interception of atmospheric nitrogen resulting from taller tree height in CF. In vertical distribution, CF showed generally higher ion concentrations in surface soil solution than at 50 cm, whereas in BF, this phenomenon was observed only for NO3−, NH4+, and K+, consistent with bamboo’s high demand for macronutrients. Significant correlations between the concentration of NO3− and those of Ca2+ and Mg2+ were absent only in BF soil leachate. Conversely, a deficit of strong anions showed a significant correlation with the concentration of Ca2+ and Mg2+ in BF soil leachate, with HCO3− identified as a potentially major component. Our findings provide insights into the concomitant-ion relationships between base cations and NO3− across forest types and soil depths.
Citrate Dialysate with and without Magnesium Supplementation in Hemodiafiltration: A Comparative Study Versus Acetate
The choice of dialysate buffer in hemodialysis is crucial, with acetate being widely used despite complications. Citrate has emerged as an alternative because of its favorable effects, yet concerns persist about its impact on calcium and magnesium levels. This study investigates the influence of citrate dialysates (CDs) with and without additional magnesium supplementation on CKD-MBD biomarkers and assesses their ability to chelate divalent metals compared to acetate dialysates (ADs). A prospective crossover study was conducted in a single center, involving patients on thrice-weekly online hemodiafiltration (HDF). The following four dialysates were compared: two acetate-based and two citrate-based. Calcium, magnesium, iPTH, iron, selenium, cadmium, copper, zinc, BUN, albumin, creatinine, bicarbonate, and pH were monitored before and after each dialysis session. Seventy-two HDF sessions were performed on eighteen patients. The CDs showed stability in iPTH levels and reduced post-dialysis total calcium, with no significant increase in adverse events. Magnesium supplementation with CDs prevented hypomagnesemia. However, no significant differences among dialysates were observed in the chelation of other divalent metals. CDs, particularly with higher magnesium concentrations, offer promising benefits, including prevention of hypomagnesemia and stabilization of CKD-MBD parameters, suggesting citrate as a viable alternative to acetate. Further studies are warranted to elucidate long-term outcomes and optimize dialysate formulations. Until then, given our results, we recommend that when a CD is used, it should be used with a 0.75 mmol/L Mg concentration rather than a 0.5 mmol/L one.