Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
2,513
result(s) for
"Tomography Scanners, X-Ray Computed"
Sort by:
Statistical analysis for obtaining optimum number of CT scanners in patient dose surveys for determining national diagnostic reference levels
by
Parsi, Masoumeh
,
Sohrabi, Mehdi
,
Sanaz Hariri Tabrizi
in
Coefficient of variation
,
Computed tomography
,
Diagnostic systems
2019
ObjectivesTo statistically determine an ‘optimum number of CT scanners’ for obtaining ‘diagnostic reference levels’ (DRLs) in CT examinations as close as possible to ‘ideal DRLs’ when all available CT scanners are considered.MethodsFirst, six ‘ideal DRLs’ (CTDIVol and DLP) were determined for head, chest and abdomen/pelvis examinations by using patient-dose survey data of 100 CT scanners of different models in Tehran. Then, a ‘random sampling method’ was applied to different percent fractions of patient dose data of 100 CT scanners. The percent differences (PD) of the DRLs obtained from ‘ideal DRLs’ and their coefficients of variation (CVs) were calculated. The ‘optimum number of CT scanners’ determined met those of ‘ideal DRL’ criteria; i.e. precision (CV ≤ 10%) and accuracy (PD ≤ 10%).Results‘Optimum number of CT scanners’ for determining DRLs as close as possible to ‘ideal DRLs’, fulfilling the stated criteria, is 43 instead of using 100.Conclusion‘Optimum number of CT scanners’ for obtaining DRLs as close as possible to ‘ideal DRLs’ was determined. This optimum number can be effectively applied in patient-dose survey situations with limited resources in a time- and cost-effective manner.Key Points• Ideal DRLs were determined by a CT patient-dose survey applied to available scanners.• ‘Optimum number of CT scanners’ statistically determined for DRLs is 43%.• Optimum number can be used for DRLs as if ‘ideal DRLs’ were determined by all scanners.
Journal Article
Brain Swelling and Loss of Gray and White Matter Differentiation in Human Postmortem Cases by Computed Tomography
2015
The purpose of this study was to evaluate the brain by postmortem computed tomography (PMCT) versus antemortem computed tomography (AMCT) using brains from the same patients. We studied 36 nontraumatic subjects who underwent AMCT, PMCT, and pathological autopsy in our hospital between April 2009 and December 2013. PMCT was performed within 20 h after death, followed by pathological autopsy including the brain. Autopsy confirmed the absence of intracranial disorders that might be related to the cause of death or might affect measurements in our study. Width of the third ventricle, width of the central sulcus, and attenuation in gray matter (GM) and white matter (WM) from the same area of the basal ganglia, centrum semiovale, and high convexity were statistically compared between AMCT and PMCT. Both the width of the third ventricle and the central sulcus were significantly shorter in PMCT than in AMCT (P < 0.0001). GM attenuation increased after death at the level of the centrum semiovale and high convexity, but the differences were not statistically significant considering the differences in attenuation among the different computed tomography scanners. WM attenuation significantly increased after death at all levels (P<0.0001). The differences were larger than the differences in scanners. GM/WM ratio of attenuation was significantly lower by PMCT than by AMCT at all levels (P<0.0001). PMCT showed an increase in WM attenuation, loss of GM-WM differentiation, and brain swelling, evidenced by a decrease in the size of ventricles and sulci.
Journal Article
Voxelwise characterization of noise for a clinical photon-counting CT scanner with a model-based iterative reconstruction algorithm
2025
Background
Photon-counting detector (PCD) technology has the potential to reduce noise in computed tomography (CT). This study aimed to carry out a voxelwise noise characterization for a clinical PCD-CT scanner with a model-based iterative reconstruction algorithm (QIR).
Methods
Forty repeated axial acquisitions (tube voltage 120 kV, tube load 200 mAs, slice thickness 0.4 mm) of a homogeneous water phantom and CTP404 module (Catphan-504) were performed. Water phantom acquisitions were also performed on a conventional energy-integrating detector (EID) scanner with a sinogram/image-based iterative reconstruction algorithm, using similar acquisition/reconstruction parameters. For smooth/sharp kernels, filtered back projection (FBP)- and iterative-reconstructed images were obtained. Noise maps, non-uniformity index (NUI) of noise maps, image noise histograms, and noise power spectrum (NPS) curves were computed.
Results
For FBP-reconstructed images of water phantom, mean noise was (smooth/sharp kernel) 11.7 HU/51.1 HU and 18.3 HU/80.1 HU for PCD-scanner and EID-scanner, respectively, with NUI values for PCD-scanner less than half those for EID-scanner. Percentage noise reduction increased with increasing iterative power, up to (smooth/sharp kernel) 57.7%/72.5% and 56.3%/70.1% for PCD-scanner and EID-scanner, respectively. For PCD-scanner, FBP- and QIR-reconstructed images featured an almost Gaussian distribution of noise values, whose shape did not appreciably vary with iterative power. Noise maps of CTP404 module showed increased NUI values with increasing iterative power, up to (smooth/sharp kernel) 15.7%/9.2%. QIR-reconstructed images showed limited low-frequency shift of NPS peak frequency.
Conclusion
PCD-CT allowed appreciably reducing image noise while improving its spatial uniformity. QIR algorithm decreases image noise without modifying its histogram distribution shape, and partly preserving noise texture.
Relevance statement
This phantom study corroborates the capability of photon-counting detector technology in appreciably reducing CT imaging noise and improving spatial uniformity of noise values, yielding a potential reduction of radiation exposure, though this needs to be assessed in more detail.
Key Points
First voxelwise characterization of noise for a clinical CT scanner with photon-counting detector technology.
Photon-counting detector technology has the capability to appreciably reduce CT imaging noise and improve spatial uniformity of noise values.
In photon-counting CT, a model-based iterative reconstruction algorithm (QIR) allows decreasing effectively image noise.
This is done without modifying noise histogram distribution shape, while limiting the low-frequency shift of noise power spectrum peak frequency.
Graphical Abstract
Journal Article
Dark-field computed tomography reaches the human scale
2022
X-ray computed tomography (CT) is one of the most commonly used three-dimensional medical imaging modalities today. It has been refined over several decades, with the most recent innovations including dual-energy and spectral photon-counting technologies. Nevertheless, it has been discovered that wave-optical contrast mechanisms—beyond the presently used X-ray attenuation—offer the potential of complementary information, particularly on otherwise unresolved tissue microstructure. One such approach is dark-field imaging, which has recently been introduced and already demonstrated significantly improved radiological benefit in small-animal models, especially for lung diseases. Until now, however, dark-field CT could not yet be translated to the human scale and has been restricted to benchtop and small-animal systems, with scan durations of several minutes or more. This is mainly because the adaption and upscaling to the mechanical complexity, speed, and size of a human CT scanner so far remained an unsolved challenge. Here, we now report the successful integration of a Talbot–Lau interferometer into a clinical CT gantry and present dark-field CT results of a human-sized anthropomorphic body phantom, reconstructed from a single rotation scan performed in 1 s. Moreover, we present our key hardware and software solutions to the previously unsolved road-blocks, which so far have kept dark-field CT from being translated from the optical bench into a rapidly rotating CT gantry, with all its associated challenges like vibrations, continuous rotation, and large field of view. This development enables clinical dark-field CT studies with human patients in the near future.
Journal Article
Clinical applications of photon counting detector CT
by
Baffour, Francis I.
,
McCollough, Cynthia H.
,
Flohr, Thomas G.
in
Anatomy
,
Blood vessels
,
Bones
2023
The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging.
Key Points
• Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging.
• Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution.
• Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.
Journal Article
Patients undergoing recurrent CT scans: assessing the magnitude
by
Heil, John
,
Liu, Bob
,
Yang, Kai
in
Age composition
,
Computed tomography
,
Industrial development
2020
ObjectivesTo assess percent of patients undergoing multiple CT exams that leads to cumulative effective dose (CED) of ≥ 100 mSv and determine their age distribution.MethodsData was retrieved retrospectively from established radiation dose monitoring systems by setting the threshold value of 100 mSv at four institutions covering 324 hospitals. The number of patients with CED ≥ 100 mSv only from recurrent CT exams during a feasible time period between 1 and 5 years was identified. Age and gender distribution of these patients were assessed to identify the magnitude of patients in the relatively lower age group of ≤ 50 years.ResultsOf the 2.5 million (2,504,585) patients who underwent 4.8 million (4,819,661) CT exams during the period of between 1 and 5 years, a total of 33,407 (1.33%) patients received a CED of ≥ 100 mSv with an overall median CED of 130.3 mSv and maximum of 1185 mSv. Although the vast majority (72–86%) of patients are > 50 years of age, nearly 20% (13.4 to 28%) are ≤ 50 years. The minimum time to accrue 100 mSv was a single day at all four institutions, an unreported finding to date.ConclusionsWe are in an unprecedented era, where patients undergoing multiple CT exams and receiving CED ≥ 100 mSv are not uncommon. While underscoring the need for imaging appropriateness, the consideration of the number and percent of patients with high exposures and related clinical necessities creates an urgent need for the industry to develop CT scanners and protocols with sub-mSv radiation dose, a goal that has been lingering.Key Points• We are in an era where patients undergoing multiple CT exams during a short span of 1 to 5 years are not uncommon and a sizable fraction among them are below 50 years of age.• This leads to cumulative radiation dose to individual patients at which radiation effects are of real concern.• There is an urgent need for the industry to develop CT scanners with sub-mSv radiation dose, a goal that has been lingering.
Journal Article
Carotid Atheroma Rupture Observed In Vivo and FSI-Predicted Stress Distribution Based on Pre-rupture Imaging
by
Saloner, David
,
Leach, Joseph R
,
Mofrad, Mohammad R. K
in
adverse effects
,
Aged, 80 and over
,
atherosclerosis
2010
Atherosclerosis at the carotid bifurcation is a major risk factor for stroke. As mechanical forces may impact lesion stability, finite element studies have been conducted on models of diseased vessels to elucidate the effects of lesion characteristics on the stresses within plaque materials. It is hoped that patient-specific biomechanical analyses may serve clinically to assess the rupture potential for any particular lesion, allowing better stratification of patients into the most appropriate treatments. Due to a sparsity of in vivo plaque rupture data, the relationship between various mechanical descriptors such as stresses or strains and rupture vulnerability is incompletely known, and the patient-specific utility of biomechanical analyses is unclear. In this article, we present a comparison between carotid atheroma rupture observed in vivo and the plaque stress distribution from fluid-structure interaction analysis based on pre-rupture medical imaging. The effects of image resolution are explored and the calculated stress fields are shown to vary by as much as 50% with sub-pixel geometric uncertainty. Within these bounds, we find a region of pronounced elevation in stress within the fibrous plaque layer of the lesion with a location and extent corresponding to that of the observed site of plaque rupture.
Journal Article
Visualization of bone details in a novel photon-counting dual-source CT scanner—comparison with energy-integrating CT
by
Decker, Josua A.
,
Kroencke, Thomas J.
,
Schwarz, Florian
in
Bones
,
Computed Tomography
,
Delineation
2022
Objectives
Photon-counting detector CT (PCD-CT) promises a leap in spatial resolution due to smaller detector pixel sizes than implemented in energy-integrating detector CTs (EID-CT). Our objective was to compare the visualization of smallest bone details between PCD-CT and EID-CT using a mouse as a specimen.
Materials and methods
Two euthanized mice were scanned at a 20-slice EID-CT and a dual-source PCD-CT in single-pixel mode at various CTDI
Vol
values. Image noise and signal-to-noise ratio (SNR) were evaluated using repeated ROI measurements. Edge sharpness of bones was compared by the maximal slope within CT value plots along sampling lines intersecting predefined bones of the spine. Two readers evaluated bone detail visualization at four regions of the spine on a three-point Likert scale at various CTDI
Vol
’s. Two radiologists selected the series with better detail visualization among each of 20 SNR-matched pairs of EID-CT and PCD-CT series.
Results
In CTDI
Vol
-matched scans, PCD-CT series showed significantly lower image noise (Noise
CTDI
=
5 mGy
: 16.27 ± 1.39 vs. 23.46 ± 0.96 HU,
p
< 0.01), higher SNR (SNR
CTDI
=
5 mGy
: 20.57 ± 1.89 vs. 14.00 ± 0.66,
p
< 0.01), and higher edge sharpness (Edge Slope
lumbar spine
: 981 ± 160 vs. 608 ± 146 HU/mm,
p
< 0.01) than EID-CT series. Two radiologists considered the delineation of bone details as feasible at consistently lower CTDI
Vol
values at PCD-CT than at EID-CT. In comparison of SNR-matched reconstructions, PCD-CT series were still considered superior in almost all cases.
Conclusions
In this head-to-head comparison, PCD-CT showed superior objective and subjective image quality characteristics over EID-CT for the delineation of tiniest bone details. Even in SNR-matched pairs (acquired at different CTDI
Vol
’s), PCD-CT was strongly preferred by radiologists.
Key Points
•
In dose-matched scans, photon-counting detector CT series showed significantly less image noise, higher signal-to-noise ratio, and higher edge sharpness than energy-integrating detector CT series
.
•
Human observers considered the delineation of tiny bone details as feasible at much lower dose levels in photon-counting detector CT than in energy-integrating detector CT
.
•
In direct comparison of series matched for signal-to-noise ratio, photon-counting detector CT series were considered superior in almost all cases
.
Journal Article
Physical evaluation of an ultra-high-resolution CT scanner
2020
ObjectivesTo evaluate the technical performance of an ultra-high-resolution CT (UHRCT) system.MethodsThe physico-technical capabilities of a novel commercial UHRCT system were assessed and compared with those of a current-generation multi-detector (MDCT) system. The super-high-resolution (SHR) mode of the system uses 0.25 mm (at isocentre) detector elements (dels) in the in-plane and longitudinal directions, while the high-resolution (HR) mode bins two dels in the longitudinal direction. The normal-resolution (NR) mode bins dels 2 × 2, resulting in a del-size equivalent to that of the MDCT system. In general, standard procedures and phantoms were used to perform these assessments.ResultsThe UHRCT MTF (10% MTF 4.1 lp/mm) is twice as high as that of the MDCT (10% MTF 1.9 lp/mm), which is comparable to the MTF in the NR mode (10% MTF 1.7 lp/mm). The width of the slice sensitivity profile in the SHR mode (FWHM 0.45 mm) is about 60% of that of the MDCT (FWHM 0.77 mm). Uniformity and CT numbers are within the expected range. Noise in the high-resolution modes has a higher magnitude and higher frequency components compared with MDCT. Low-contrast visibility is lower for the NR, HR and SHR modes compared with MDCT, but about a 14%, for NR, and 23%, for HR and SHR, dose increase gives the same results.ConclusionsHR and SHR mode scanning results in double the spatial resolution, with about a 23% increase in dose required to achieve the same low-contrast detectability.Key Points• Resolution on UHRCT is up to twice as high as for the tested MDCT.• With abdominal settings, UHRCT needs higher dose for the same low-contrast detectability as MDCT, but dose is still below achievable levels as defined by current diagnostic reference levels.• The UHRCT system used in normal-resolution mode yields comparable resolution and noise characteristics as the MDCT system.
Journal Article
Contamination inside CT gantry in the SARS-CoV-2 era
by
Veneziano, Alessio
,
Rollandi, Gian Andrea
,
Matos, João
in
Betacoronavirus - isolation & purification
,
Coronavirus Infections - virology
,
COVID-19
2020
We investigated whether the internal gantry components of our computed tomography (CT) scanner contain severe acute respiratory syndrome 2 (SARS-CoV-2) ribonucleic acid (RNA), bacterial or fungal agents
.
From 1 to 27 March 2020, we performed 180 examinations of patients with confirmed SARS-CoV-2 infection using a dedicated CT scanner. On 27 March 2020, this CT gantry was opened and sampled in each of the following components: (a) gantry case; (b) inward airflow filter; (c) gantry motor; (d) x-ray tube; (e) outflow fan; (f) fan grid; (g) detectors; and (h) x-ray tube filter. To detect SARS-CoV-2 RNA, samples were analysed using reverse transcriptase-polymerase chain reaction (RT-PCR). To detect bacterial or fungal agents, samples have been collected using “replicate organism detection and counting” contact plates of 24 cm
2
, containing tryptic soy agar, and subsequently cultured. RT-PCR detected SARS-CoV-2 RNA in the inward airflow filter sample. RT-PCR of remaining gantry samples did not reveal the presence of SARS-CoV-2 RNA. Neither bacterial nor fungal agents grew in the agar-based growth medium after the incubation period. Our data showed that SARS-Cov-2 RNA can be found inside the CT gantry only in the inward airflow filter. All remaining CT gantry components were devoid of SARS-CoV-2 RNA.
Journal Article