Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
24 result(s) for "Translational musculoskeletal research: Bridging the gap between lab and clinic"
Sort by:
Neutrophil extracellular traps induce the bone erosion of gout
Objective To investigate the relationships between monosodium urate (MSU) crystals -induced neutrophil extracellular traps (NETs) and bone erosion in gout. Methods Animal models were used to study the relationship between NETs induced by MSU crystals and bone erosion. Neutrophils were treated with MSU crystals to induce NETs. The osteoblasts-like cells (OB) were then treated with NETs, and the supernatant was co-incubated with osteoclasts-like cells (OC). The NETs were digested with DNase, and the neutrophil elastase (NE) was inhibited with sivelestat sodium. Cell viability, mRNA, and protein expression were also assessed. Results After treating OB with NETs, the cell viability decreased. Yet, after digesting the DNA and inhibiting NE, the viability was moderately improved. The expression level of osteoprotegerin (OPG) and alkaline phosphatase (ALP) was up-regulated, while the expression level of receptor activator of nuclear factor kappa-B ligand (RANKL) was down-regulated in the sivelestat sodium + MSU group compared with MSU group. The number of OC was significantly elevated. In contrast, the number of OB was not increased in the tibia after establishing the gout model. The supernatant obtained from OB was treated with NETs promoting OC differentiation. The expression level of receptor activator of nuclear factor kappa-B (RANK), tartrate-resistant acid phosphatase (TRAP), and cathepsin K (Cst K) was up-regulated in the MSU group compared with the normal control (NC) group. Conclusion NETs induced by MSU crystals could inhibit osteoblasts viability and enhance the activity of osteoclasts.
Comparison of proprioception recovery following anterior cruciate ligament reconstruction using an artificial graft versus an autograft
Background To compare proprioception recovery after anterior cruciate ligament reconstruction (ACLR) with a hamstring tendon autograft versus the artificial Ligament Advanced Reinforcement System (LARS). Material and methods Forty patients (9 females, 31 males) with anterior cruciate ligament (ACL) rupture were enrolled in this prospective study. Patients were randomized to two groups, 1) ACLR using a hamstring tendon autograft ( n  = 20) or 2) ACLR using artificial LARS ( n  = 20). Proprioception was assessed with knee joint position sense (JPS) passive-passive test at 45° and 75° flexions, with the contralateral healthy knee as a control baseline to calculate the JPS error. Knee JPS absolute error was used as the main outcome variable and defined as the absolute difference between the reproduction and target angles. Results JPS error in both groups at 3 months after ACLR was significantly higher than that at 12 months. However, no significant difference in JPS error was detected between the LARS and autograft groups at either 3 or 12 months after ACLR. Analyzing JPS data by grouping patients according to whether ACLR was performed more or less than 1 year following injury regardless of graft type showed a statistically significant difference between the groups at 3 months, but not at 12 months, after ACLR. Patients receiving the graft within 1 year of injury had a lower JPS error than those receiving the graft more than 1 year after injury at 3 months. No complications were associated with either ACLR method. Conclusion ACLR with a hamstring tendon autograft or LARS artificial graft is similarly safe and effective for recovering knee proprioception.
Effect of nanoparticles on gouty arthritis: a systematic review and meta-analysis
Objective The purpose of this study was to explore the effects of nanoparticles on gouty arthritis, and to provide evidence for the preclinical application of nanoparticles in gouty arthritis and ideas for nanomedicine improvement for nanoparticle researchers. Methods Five databases including the Cochrane Library, PubMed, Scopus, Web of Science, and Embase were searched for eligible studies until April 2022. The quality of the selected studies was assessed by SYRCLE’s risk of bias (RoB) tool, and the random-effects model was used to calculate the overall effect sizes of weighted mean differences (WMD). Results Ten studies met the inclusion criteria. Results showed that nanoparticles were effective in reducing uric acid levels (WMD: -4.91; 95% confidence interval (CI): − 5.41 to − 4.41; p  < 0.001), but were not better than allopurinol (WMD: -0.20; 95% CI: − 0.42 to 0.02; p  = 0.099). It was worth noting that the nanoparticles were safer than allopurinol. Subgroup analyses indicated that nanoparticle encapsulated substance, animal species, nanoparticle dosage, animal quantity, and animal gender were all sources of heterogeneity. Conclusion The nanoparticles are safe medications for gouty arthritis which can effectively reduce uric acid levels in rodents. Although the results are still uncertain, it is expected to have certain clinical application value. The nanoparticles may be the preclinical medications for gouty arthritis in the future.
A longitudinal rat model for assessing postoperative recovery and bone healing following tibial osteotomy and plate fixation
Background Rodent models are commonly employed to validate preclinical disease models through the evaluation of postoperative behavior and allodynia. Our study investigates the dynamic interplay between pain and functional recovery in the context of traumatic osteotomy and surgical repair. Specifically, we established a rat model of tibial osteotomy, followed by internal fixation using a 5-hole Y-plate with 4 screws, to explore the hypothesis that histological bone healing is closely associated with functional recovery. Objective Our primary objective was to assess the correlation between bone healing and functional outcomes in a rat model of tibial osteotomy and plate fixation. Methods Seventeen male Sprague–Dawley rats underwent a metaphyseal transverse osteotomy of the proximal tibia, simulating a fracture-like injury. The resultant bone defect was meticulously repaired by realigning and stabilizing the bone surfaces with the Y-plate. To comprehensively assess recovery and healing, we performed quantitative and qualitative evaluations at 2, 4, 6, and 8 weeks post-surgery. Evaluation methods included micro-CT imaging, X-ray analysis, and histological examination to monitor bone defect healing. Concurrently, we employed video recording and gait analysis to evaluate functional recovery, encompassing parameters such as temporal symmetry, hindlimb duty factor imbalance, phase dispersion, and toe spread. Results Our findings revealed complete healing of the bone defect at 8 weeks, as confirmed by micro-CT and histological assessments. Specifically, micro-CT data showed a decline in fracture volume over time, indicating progressive healing. Histological examination demonstrated the formation of new trabecular bone and the resolution of inflammation. Importantly, specific gait analysis parameters exhibited longitudinal changes consistent with bone healing. Hindlimb duty factor imbalance, hindlimb temporal symmetry, and phase dispersion correlated strongly with the healing process, emphasizing the direct link between bone healing and functional outcomes. Conclusions The establishment of this tibia osteotomy model underscores the association between bone healing and functional outcomes, emphasizing the feasibility of monitoring postoperative recovery using endpoint measurements. Our overarching objective is to employ this model for assessing the local efficacy of drug delivery devices in ameliorating post-surgical pain and enhancing functional recovery.
A simple method to improve the antibiotic elution profiles from polymethylmethacrylate bone cement spacers by using rapid absorbable sutures
Objective Antibiotic-loaded bone cement beads and spacers have been widely used for orthopaedic infection. Poor antibiotic elution is not capable of eradicating microbial pathogens and could lead to treatment failure. The elution profiles differ among different cement formulations. Although Simplex P cement has the least release amount, it is widely used due to its ready availability. Previous methods aiming to improve the elution profiles were not translated well to clinical practice. We sought to address this by using easily available materials to improve the elution profile of antibiotics from PMMA, which allows clinicians to implement the method intraoperatively. Methods Vancomycin was mixed with Simplex P cement. We used Vicryl Rapide sutures to fabricate sustained-release cement beads by repetitively passing the sutures through the beads and/or mixing suture segments into the cement formulation. Vancomycin elution was measured for 49 days. The mechanism of antibiotic release was observed with gross appearance and scanning electron microscopic images. The antimicrobial activities against MRSA were tested using an agar disk diffusion bioassay. Results Passing Vicryl Rapide sutures through cement beads significantly improved the elution profiles in the 7-week period. The increased ratios were 9.0% on the first day and 118.0% from the 2nd day to the 49th day. Addition of suture segments did not increase release amount. The Vicryl Rapide sutures completely degraded at the periphery and partially degraded at the center. The antibiotic particles were released around the suture, while antibiotic particles kept densely entrapped in the control group. The antimicrobial activities were stronger in passing suture groups. Conclusion Passing fast absorbable sutures through PMMA cement is a feasible method to fabricate sustained-release antibiotic bone cement. Intra-cement tunnels can be formed, and the effect can last for at least 7 weeks. It is suitable for a temporary spacer between two stages of a revision surgery.
Research progress and hot spot analysis related to oxidative stress and osteoarthritis: a bibliometric analysis
Background Osteoarthritis, a common degenerative osteochondral disease, has a close relationship between its mechanism of occurrence and oxidative stress. However, there are relatively few relevant studies in this field, and a more mature research system has not yet been formed. Methods By searching the Web of Science (WOS) database, we obtained 1 412 publications in the field of osteoarthritis and oxidative stress. The search results were then analyzed bibliometrically using Citespace and VOSviewer, including a study of publication trends in the field, analysis of core authors, analysis of countries and institutions with high contributions, analysis of core journals, and to identify research trends and hot spots in the field, we performed keyword clustering. Results We collected 1 412 publications on the field of osteoarthritis and oxidative stress from 1998–2022. By analyzing the publication trends in the field, we noted an exponential increase in the number of publications per year since 2014. We then identified the core authors in the field (Blanco, Francisco J., Loeser, Richard F., Vaamonde-garcia, et.al) as well as the countries (China, USA, Italy et.al) and institutions (Xi An Jiao Tong Univ, Wenzhou Med Univ, Zhejiang Univ et.al). The OSTEOARTHRITIS AND CARTILAGE and INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES contain a large number of research papers in this field, and through keyword co-occurrence analysis, we counted 3 227 keywords appearing in the field of osteoarthritis and oxidative stress. These keywords were clustered into 9 groups, representing 9 different research hotspots. Conclusions Research in the field of osteoarthritis and oxidative stress has been developing since 1998 and is now maturing, but there is an urgent need to strengthen international academic exchanges and discuss the future focus of research development in the field of osteoarthritis and oxidative stress.
The effect of ding’s screw and tension band wiring for treatment of olecranon fractures: a finite element study
Background Tension band wiring (TBW) is a common surgical intervention for olecranon fractures. However, high rate of complications such as loss of reduction, skin irritation, and migration of the K-wires were reported up to 80%. Ding’s screw tension band wiring (DSTBW) is a new TBW technique that has shown positive results in the treatment of other fracture types. The objective of this study was to evaluate the stability of DSTBW in the treatment of olecranon fractures by finite element analysis. Method We used Ding’s screw tension band fixation (DSTBW) and K-wire tension band fixation (TBW) to establish a finite element model to simulate and fix olecranon fractures. The stress distribution, opening angle, twisting angle, and pullout strength of K-wires or screws were analyzed and compared. Results The maximum von Mises stress was observed on the internal fixation for 90° elbow motion in both groups. The von Mises value of the screw in DSTBW was 241.2 MPa, and the von Mises value of k-wire in TBW was 405.0 MPa. Opening angle: TBW was 0.730° and DSTBW was 0.741° at 45° flexion; TBW was 0.679° and DSTBW was 0.693° at 90° flexion. Twisting angle: TBW was 0.146° and DSTBW was 0.180° at 45° flexion; TBW was 0.111° and DSTBW was 0.134° at 90° flexion. The pullout strength of DSTBW was significantly higher than that of TBW. Maximum pullout strength of Ding’s screw was 2179.1 N, maximum pullout strength of K-wire was 263.6 N. Conclusion DSTBW technology provides stable fixation for olecranon fractures, reducing the risk of internal fixation migration and failure.
Clinical application of instant 3D printed cast versus polymer orthosis in the treatment of colles fracture: a randomized controlled trial
Background The shortcomings of plaster in water resistance, air permeability, skin comfort, fixed stability and weight of wearing are still to be solved. 3D printed cast can overcome the above shortcomings. At present, there is a relative lack of data on the clinical application of 3D printed cast, probably due to its complexity, relatively long operating time, and high price. We aimed to compare and evaluate the short-term effectiveness, safety and advantages of 3D printed wrist cast versus polymer orthosis in the treatment of Colles fracture. Methods Forty patients with Colles fracture in our hospital from June to December 2022 were selected and divided into an observation group (20 patients, treated with instant 3D printed cast) and a control group (20 cases, treated with polymer orthosis). Both groups treated with manual reduction and external fixation. The visual analogue scale (VAS), immobilization effectiveness and satisfaction scores, Disability of the Arm, Shoulder and Hand (DASH) score, complications and imaging data were collected and compared before immobilization and at 2, 6 and 12 weeks after the fracture. Results VAS at 2 weeks after the fracture was significantly lower in the observation group than in the control group ( P  < 0.05). The immobilization effectiveness and satisfaction scores at 6 weeks after the fracture were significantly higher in the observation group than in the control group (all P  < 0.05). The DASH scores at 2 and 6 weeks after the fracture were significantly lower in the observation group than in the control group (all P  < 0.05). There wasn’t rupture of the printed cast or orthosis in both groups. There were 2 cases of skin irritation in the control group, and no skin irritation occurred in the observation group. The palmar tilt angle and ulnar inclination angle at 2 weeks and 12 weeks after the fracture were significantly higher in the observation group than in the control group (all P  < 0.05). Conclusions Both instant 3D printed cast and polymer orthosis are effective in the treatment of Colles fracture. But instant 3D printed cast is better than polymer orthosis in areas of good clinical and imaging performance, and high patient satisfaction and comfort.
Transcriptome profiling of a synergistic volumetric muscle loss repair strategy
Volumetric muscle loss overwhelms skeletal muscle’s ordinarily capable regenerative machinery, resulting in severe functional deficits that have defied clinical repair strategies. In this manuscript we pair the early in vivo functional response induced by differing volumetric muscle loss tissue engineering repair strategies that are broadly representative of those explored by the field (scaffold alone, cells alone, or scaffold + cells) to the transcriptomic response induced by each intervention. We demonstrate that an implant strategy comprising allogeneic decellularized skeletal muscle scaffolds seeded with autologous minced muscle cellular paste (scaffold + cells) mediates a pattern of increased expression for several genes known to play roles in axon guidance and peripheral neuroregeneration, as well as several other key genes related to inflammation, phagocytosis, and extracellular matrix regulation. The upregulation of several key genes in the presence of both implant components suggests a unique synergy between scaffolding and cells in the early period following intervention that is not seen when either scaffolds or cells are used in isolation; a finding that invites further exploration of the interactions that could have a positive impact on the treatment of volumetric muscle loss.
Measurement of the sustentaculum tali range and biomechanical screw analysis based on the space shape of the calcaneal trabeculae
Background The sustentaculum tali (ST) plays an important role in the surgical treatment of calcaneal fracture. However, there is a lack of relevant literature report on the true extent of the distance process. The introduction of the ‘space shape of the trabeculae within the calcaneus allowed the ST range to be defined with reference to the trabecula topographic trend. Here, we investigated the biomechanical properties of two common ST screws after implantation by applying the finite element method (FEM). Methods Dicom imaging data of the calcaneus ST was obtained by computed tomography (CT)scanning techniques and a spatial three-dimensional (3D) coordinate system was established to measure the extent of the ST. The continuation range was identified according to the trend of the trabecula bone and then superimposed to form a new ST range. Next, by structural design and FEM, we performed biomechanical tests on the two type of ST screws: the ‘pressure type (transverse group)’ test for vertical fracture lines and the ‘tension type (oblique group) of the center’ test. Results Based on space shape of the trabeculae within the calcaneus, the spatial extent of the ST was redefined. According to FEM calculations, the load bearing capacity of the transverse group was better than that of the oblique group by 15.15% when the screws were implanted in the peak area. Furthermore, the load bearing capacity of the oblique group was better than that of the transverse group by 14.13% and 5.59% when the screws were implanted in the lumbar and valley regions. Conclusions Based on the space shape of the trabeculae within the calcaneus, the range of the ST is expanded. The best mechanical properties of two different screws were implanted in the peak area. The load-bearing capacity gradually reduced when implanted in the lumbar and valley regions. However, the waist area and valley area can still meet the requirements for structural strength and stability, and also provide a good fixation effect. Level of evidence Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.