Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
99,818
result(s) for
"X-ray computed tomography"
Sort by:
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
by
Clapp, Jonathan D
,
Sicks, JoRean D
,
Aberle, Denise R
in
Aged
,
Bias
,
Biological and medical sciences
2011
The National Lung Screening Trial investigators report that persons undergoing three annual screening examinations with low-dose computed tomography had a 20% reduction in lung-cancer mortality as compared with those screened with annual chest radiography.
Lung cancer is an aggressive and heterogeneous disease.
1
,
2
Advances in surgical, radiotherapeutic, and chemotherapeutic approaches have been made, but the long-term survival rate remains low.
3
After the Surgeon General's 1964 report on smoking and health, mortality from lung cancer among men peaked and then fell; among women, the peak occurred later and a slight decline has occurred more recently.
4
Even though the rate of heavy smoking continues to decline in the United States,
5
94 million current or former smokers remain at elevated risk for the disease,
6
and lung cancer remains the leading cause of death from cancer in this . . .
Journal Article
EANM procedure guidelines for brain PET imaging using 18FFDG, version 3
by
Law, Ian
,
Semah, Franck
,
Van Weehaeghe, Donatienne
in
Alzheimer's disease
,
Brain
,
Brain - diagnostic imaging
2022
The present procedural guidelines summarize the current views of the EANM Neuro-Imaging Committee (NIC). The purpose of these guidelines is to assist nuclear medicine practitioners in making recommendations, performing, interpreting, and reporting results of [
18
F]FDG-PET imaging of the brain. The aim is to help achieve a high-quality standard of [
18
F]FDG brain imaging and to further increase the diagnostic impact of this technique in neurological, neurosurgical, and psychiatric practice. The present document replaces a former version of the guidelines that have been published in 2009. These new guidelines include an update in the light of advances in PET technology such as the introduction of digital PET and hybrid PET/MR systems, advances in individual PET semiquantitative analysis, and current broadening clinical indications (e.g., for encephalitis and brain lymphoma). Further insight has also become available about hyperglycemia effects in patients who undergo brain [
18
F]FDG-PET. Accordingly, the patient preparation procedure has been updated. Finally, most typical brain patterns of metabolic changes are summarized for neurodegenerative diseases. The present guidelines are specifically intended to present information related to the European practice. The information provided should be taken in the context of local conditions and regulations.
Journal Article
Exposure to low dose computed tomography for lung cancer screening and risk of cancer: secondary analysis of trial data and risk-benefit analysis
by
De Marco, Paolo
,
Origgi, Daniela
,
Casiraghi, Monica
in
Adult
,
Early Detection of Cancer
,
Female
2017
Objective To estimate the cumulative radiation exposure and lifetime attributable risk of cancer incidence associated with lung cancer screening using annual low dose computed tomography (CT).Design Secondary analysis of data from a lung cancer screening trial and risk-benefit analysis.Setting 10 year, non-randomised, single centre, low dose CT, lung cancer screening trial (COSMOS study) which took place in Milan, Italy in 2004-15 (enrolment in 2004-05). Secondary analysis took place in 2015-16.Participants High risk asymptomatic smokers aged 50 and older, who were current or former smokers (≥20 pack years), and had no history of cancer in the previous five years.Main outcome measures Cumulative radiation exposure from low dose CT and positron emission tomography (PET) CT scans, calculated by dosimetry software; and lifetime attributable risk of cancer incidence, calculated from the Biological Effects of Ionizing Radiation VII (BEIR VII) report.Results Over 10 years, 5203 participants (3439 men, 1764 women) underwent 42 228 low dose CT and 635 PET CT scans. The median cumulative effective dose at the 10th year of screening was 9.3 mSv for men and 13.0 mSv for women. According to participants’ age and sex, the lifetime attributable risk of lung cancer and major cancers after 10 years of CT screening ranged from 5.5 to 1.4 per 10 000 people screened, and from 8.1 to 2.6 per 10 000 people screened, respectively. In women aged 50-54, the lifetime attributable risk of lung cancer and major cancers was about fourfold and threefold higher than for men aged 65 and older, respectively. The numbers of lung cancer and major cancer cases induced by 10 years of screening in our cohort were 1.5 and 2.4, respectively, which corresponded to an additional risk of induced major cancers of 0.05% (2.4/5203). 259 lung cancers were diagnosed in 10 years of screening; one radiation induced major cancer would be expected for every 108 (259/2.4) lung cancers detected through screening.Conclusion Radiation exposure and cancer risk from low dose CT screening for lung cancer, even if non-negligible, can be considered acceptable in light of the substantial mortality reduction associated with screening.
Journal Article
International variation in radiation dose for computed tomography examinations: prospective cohort study
2019
To determine patient, institution, and machine characteristics that contribute to variation in radiation doses used for computed tomography (CT).
Prospective cohort study.
Data were assembled and analyzed from the University of California San Francisco CT International Dose Registry.
Standardized data from over 2.0 million CT examinations of adults who underwent CT between November 2015 and August 2017 from 151 institutions, across seven countries (Switzerland, Netherlands, Germany, United Kingdom, United States, Israel, and Japan).
Mean effective doses and proportions of high dose examinations for abdomen, chest, combined chest and abdomen, and head CT were determined by patient characteristics (sex, age, and size), type of institution (trauma center, care provision 24 hours per day and seven days per week, academic, private), institutional practice volume, machine factors (manufacturer, model), country, and how scanners were used, before and after adjustment for patient characteristics, using hierarchical linear and logistic regression. High dose examinations were defined as CT scans with doses above the 75th percentile defined during a baseline period.
The mean effective dose and proportion of high dose examinations varied substantially across institutions. The doses varied modestly (10-30%) by type of institution and machine characteristics after adjusting for patient characteristics. By contrast, even after adjusting for patient characteristics, wide variations in radiation doses across countries persisted, with a fourfold range in mean effective dose for abdomen CT examinations (7.0-25.7 mSv) and a 17-fold range in proportion of high dose examinations (4-69%). Similar variation across countries was observed for chest (mean effective dose 1.7-6.4 mSv, proportion of high dose examinations 1-26%) and combined chest and abdomen CT (10.0-37.9 mSv, 2-78%). Doses for head CT varied less (1.4-1.9 mSv, 8-27%). In multivariable models, the dose variation across countries was primarily attributable to institutional decisions regarding technical parameters (that is, how the scanners were used).
CT protocols and radiation doses vary greatly across countries and are primarily attributable to local choices regarding technical parameters, rather than patient, institution, or machine characteristics. These findings suggest that the optimization of doses to a consistent standard should be possible.
Clinicaltrials.gov NCT03000751.
Journal Article
Diagnostic reference levels and median doses for common clinical indications of CT: findings from an international registry
by
Duong, Phuong-Anh T.
,
Jeukens, Cécile R. L. P. N.
,
Luong, Jason
in
Adult
,
Angiography
,
Appendicitis
2022
Ob jectives
The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry.
Methods
Standardized data on 3.7 million CTs in adults were collected between 2016 and 2019 from 161 institutions across seven countries (United States of America (US), Switzerland, Netherlands, Germany, UK, Israel, Japan). DRLs (75th percentile) and median doses for volumetric CT-dose index (CTDI
vol
) and dose-length product (DLP) were assessed for each EUCLID category (chronic sinusitis, stroke, cervical spine trauma, coronary calcium scoring, lung cancer, pulmonary embolism, coronary CT angiography, hepatocellular carcinoma (HCC), colic/abdominal pain, appendicitis), and US radiation doses were compared with European.
Results
The number of CT scans within EUCLID categories ranged from 8,933 (HCC) to over 1.2 million (stroke). There was greater variation in dose between categories than within categories (
p
< .001), and doses were significantly different between categories within anatomic areas. DRLs and median doses were assessed for all categories. DRLs were higher in the US for 9 of the 10 indications (except chronic sinusitis) than in Europe but with a significantly higher sample size in the US.
Conclusions
DRLs for CTDI
vol
and DLP for EUCLID clinical indications from diverse organizations were established and can contribute to dose optimization. These values were usually significantly higher in the US than in Europe.
Key Points
•
Registry data were used to create benchmarks for 10 common indications for CT identified by the European Society of Radiology.
•
Observed US radiation doses were higher than European for 9 of 10 indications (except chronic sinusitis).
•
The presented diagnostic reference levels and median doses highlight potentially unnecessary variation in radiation dose.
Journal Article
Implant Restorations
2019,2014,2020
The fourth edition of Implant Restorations: A Step-by-Step Guide provides a wealth of updated and expanded coverage on detailed procedures for restoring dental implants. Focusing on the most common treatment scenarios, it offers concise literature reviews for each chapter and easy-to-follow descriptions of the techniques, along with high-quality clinical photographs demonstrating each step. Comprehensive throughout, this practical guide begins with introductory information on incorporating implant restorative dentistry in clinical practice. It covers diagnosis and treatment planning and digital dentistry, and addresses advances in cone beam computerized tomography (CBCT), treatment planning software, computer generated surgical guides, rapid prototype printing and impression-less implant restorative treatments, intra-oral scanning, laser sintering, and printing/milling polymer materials. Record-keeping, patient compliance, hygiene regimes, and follow-up are also covered. * Provides an accessible step-by-step guide to commonly encountered treatment scenarios, describing procedures and techniques in an easy-to-follow, highly illustrated format * Offers new chapters on diagnosis and treatment planning and digital dentistry * Covers advances in cone beam computerized tomography (CBCT), computer generated surgical guides, intra-oral scanning, laser sintering, and more An excellent and accessible guide on a burgeoning subject in modern dental practice by one of its most experienced clinicians, Implant Restorations: A Step-by-Step Guide, Fourth Edition will appeal to prosthodontists, general dentists, implant surgeons, dental students, dental assistants, hygienists, and dental laboratory technicians.
2017 WSES guidelines on colon and rectal cancer emergencies: obstruction and perforation
2018
ᅟ
Obstruction and perforation due to colorectal cancer represent challenging matters in terms of diagnosis, life-saving strategies, obstruction resolution and oncologic challenge. The aims of the current paper are to update the previous WSES guidelines for the management of large bowel perforation and obstructive left colon carcinoma (OLCC) and to develop new guidelines on obstructive right colon carcinoma (ORCC).
Methods
The literature was extensively queried for focused publication until December 2017. Precise analysis and grading of the literature has been performed by a working group formed by a pool of experts: the statements and literature review were presented, discussed and voted at the Consensus Conference of the 4th Congress of the World Society of Emergency Surgery (WSES) held in Campinas in May 2017.
Results
CT scan is the best imaging technique to evaluate large bowel obstruction and perforation. For OLCC, self-expandable metallic stent (SEMS), when available, offers interesting advantages as compared to emergency surgery; however, the positioning of SEMS for surgically treatable causes carries some long-term oncologic disadvantages, which are still under analysis. In the context of emergency surgery, resection and primary anastomosis (RPA) is preferable to Hartmann’s procedure, whenever the characteristics of the patient and the surgeon are permissive. Right-sided loop colostomy is preferable in rectal cancer, when preoperative therapies are predicted.
With regards to the treatment of ORCC, right colectomy represents the procedure of choice; alternatives, such as internal bypass and loop ileostomy, are of limited value.
Clinical scenarios in the case of perforation might be dramatic, especially in case of free faecal peritonitis. The importance of an appropriate balance between life-saving surgical procedures and respect of oncologic caveats must be stressed. In selected cases, a damage control approach may be required.
Medical treatments including appropriate fluid resuscitation, early antibiotic treatment and management of co-existing medical conditions according to international guidelines must be delivered to all patients at presentation.
Conclusions
The current guidelines offer an extensive overview of available evidence and a qualitative consensus regarding management of large bowel obstruction and perforation due to colorectal cancer.
Journal Article
Lung cancer screening with volume computed tomography is cost-effective in Greece
2025
This study aimed to assess the cost-effectiveness of lung cancer screening (LCS) employing volume-based low-dose computed tomography (LDCT) in contrast to the absence of screening, targeting an asymptomatic high-risk population in Greece, leveraging the outcomes derived from the NELSON study, the largest European randomized control trial dedicated to LCS.
A validated model incorporating a decision tree and an integrated state-transition Markov model was used to simulate the identification, diagnosis, and treatments for a population at high risk of developing lung cancer, from a healthcare payer perspective. Screen-detected lung cancers, costs, life years (LYs), quality-adjusted life years (QALYs), and the incremental cost-effectiveness ratio (ICER) were predicted. Sensitivity and scenario analyses were conducted to assess the robustness and reliability of the model's outcomes under varying parameters and hypothetical situations.
Annual LCS with volume-based LDCT detected 17,104 more lung cancer patients at early-stage among 207,885 screening population, leading to 8,761 premature lung cancer deaths averted. In addition, in contrast to no screening, LCS yielded 86,207 LYs gained and 50,207 incremental QALYs at an additional cost of €278,971,940, resulting in an ICER of €3,236 per LY and €5,505 per QALY, over a lifetime horizon. These estimates were robust in sensitivity analyses.
LCS with volume-based LDCT, targeting an asymptomatic high-risk population, is highly cost-effective in Greece. Implementing LCS ensures efficient allocation of public healthcare resources while delivering substantial clinical benefits to lung cancer patients.
Journal Article
Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations
2013
Objectives
The purpose of this study was to assess the diagnostic image quality of ultra-low-dose chest computed tomography (ULD-CT) obtained with a radiation dose comparable to chest radiography and reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard dose diagnostic CT (SDD-CT) or low-dose diagnostic CT (LDD-CT) reconstructed with FBP alone.
Methods
Unenhanced chest CT images of 42 patients acquired with ULD-CT were compared with images obtained with SDD-CT or LDD-CT in the same examination. Noise measurements and image quality, based on conspicuity of chest lesions on all CT data sets were assessed on a five-point scale.
Results
The radiation dose of ULD-CT was 0.16 ± 0.006 mSv compared with 11.2 ± 2.7 mSv for SDD-CT (
P
< 0.0001) and 2.7 ± 0.9 mSv for LDD-CT. Image quality of ULD-CT increased significantly when using MBIR compared with FBP or ASIR (
P
< 0.001). ULD-CT reconstructed with MBIR enabled to detect as many non-calcified pulmonary nodules as seen on SDD-CT or LDD-CT. However, image quality of ULD-CT was clearly inferior for characterisation of ground glass opacities or emphysema.
Conclusion
Model-based iterative reconstruction allows detection of pulmonary nodules with ULD-CT with radiation exposure in the range of a posterior to anterior (PA) and lateral chest X-ray.
Key Points
•
Radiation dose is a key concern with the increased use of thoracic CT
•
Ultra-low-dose chest CT approximates the radiation dose of conventional chest radiography
•
Ultra-low-dose chest CT can be of diagnostic quality
•
Solid pulmonary nodules are clearly depicted on ultra-low-dose chest CT
Journal Article
Psychological outcomes of low-dose CT lung cancer screening in a multisite demonstration screening pilot: the Lung Screen Uptake Trial (LSUT)
2020
BackgroundPrevious studies of psychological burden in low-dose CT (LDCT) lung cancer screening trials may lack generalisability due to participation bias and control arms having elevated distress.MethodsCurrent and former smokers (n=787, aged 60–75) within a real-world screening demonstration pilot completed measures of lung cancer worry at three time points (T0: appointment, T1: next day, T2: 3 months) and anxiety and depression at two time points (T0 and T2). A ‘screening unaware’ community sample (n=383) with the same age and smoking characteristics completed these measures once (T0). Mean scores were compared by sample type and LDCT result.ResultsCompared with the community sample (T0), mean scores were higher in the screening sample, and statistically significantly increased in adjusted analyses, for lung cancer worry at T0 and T2 (mean (M): 9.32; 95% CI 8.96 to 9.69 vs M: 11.34; 11.09 to 11.59 and M: 11.88; 11.49 to 12.27), for anxiety at T0 and T2 (M: 3.32; 2.94 to 3.70 vs M: 4.73; 4.42 to 5.04 and M: 5.78; 5.33 to 6.23) and depression at T2 (M: 3.85; 3.44 to 4.27 vs M: 4.15; 3.76 to 4.55). Scores were highest for those with indeterminate (eg, T2 anxiety M: 6.93; 5.65 to 8.21) and incidental findings (primary care follow-up M: 5.34; 4.67 to 6.02) and those ineligible for screening (M: 6.51; 5.25 to 7.77). Being female, younger, not in paid employment, not married/cohabiting with a partner and lower education predicted poorer psychological outcomes at T0, but not T2 after adjusting for baseline scores. Mean scores remained within ‘normal’ clinical ranges.ConclusionPsychological distress was raised among high-risk individuals undergoing LDCT screening in a real-world setting, but overall differences were unlikely to be clinically meaningful. It will be critical to monitor the psychological impact of services longitudinally across diverse settings, including subgroups vulnerable to clinically elevated distress.Trial registrationThe Lung Screen Uptake Trial was registered prospectively with the International Standard Registered Clinical/soCial sTudy (ISRCTN) (Number: ISRCTN21774741) on 23 September 2015 and the National Institutes of Health ClinicalTrials.gov database (NCT02558101) on 22 September 2015.
Journal Article