Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
63,585 result(s) for "bone implant"
Sort by:
Alloying design of biodegradable zinc as promising bone implants for load-bearing applications
Magnesium-based biodegradable metals (BMs) as bone implants have better mechanical properties than biodegradable polymers, yet their strength is roughly less than 350 MPa. In this work, binary Zn alloys with alloying elements Mg, Ca, Sr, Li, Mn, Fe, Cu, and Ag respectively, are screened systemically by in vitro and in vivo studies. Li exhibits the most effective strengthening role in Zn, followed by Mg. Alloying leads to accelerated degradation, but adequate mechanical integrity can be expected for Zn alloys when considering bone fracture healing. Adding elements Mg, Ca, Sr and Li into Zn can improve the cytocompatibility, osteogenesis, and osseointegration. Further optimization of the ternary Zn-Li alloy system results in Zn-0.8Li-0.4Mg alloy with the ultimate tensile strength 646.69 ± 12.79 MPa and Zn-0.8Li-0.8Mn alloy with elongation 103.27 ± 20%. In summary, biocompatible Zn-based BMs with strength close to pure Ti are promising candidates in orthopedics for load-bearing applications. Biodegradable implants are of great interest in orthopaedic applications but have been limited by low mechanical strength. Here, the authors examine systematically in detail the strengthening of biodegradable zinc by alloying with beneficial elements using mechanical, biodegradability and biocompatibility testing.
ESEM-EDX Mineralization and Morphological Analysis of Human Retrieved Maxillary Sinus Bone Graft Biopsies before Loading
This study aimed to analyze the morphology of bone graft granules, the presence of granule demineralization, and bone morphology in retrieved human maxillary sinus bone graft biopsies. Healthy patients underwent sinus bone augmentation using lateral access. Two different dimensions of the antrostomy were performed, a 4 mm or 8 mm height. After 6 months, all sites received one implant using a flap technique, crestal positioning, and submerged healing. Implant biopsies were retrieved after 3 months and were histologically processed. The ESEM analysis was performed on the entire portion of the peri-implant bone (up to 750 µm from the implant thread). Three different regions of interest (ROIs) were selected: the coronal, middle, and apical portions of the implant. In these areas, EDX was performed, and calcium (Ca), phosphate (P), nitrogen (N), and their atomic ratios (Ca/P, Ca/N, and P/N) were calculated. Different bone tissue electron-dense areas were detected through grayscale intensity quantification of ESEM images with different organic (N) or inorganic (Ca,P) compositions. A total of 16 biopsies from 16 healthy patients were analyzed. Bone graft granules were mostly detected in the apical ROI. New bone tissue bridges were detected in the apical and middle ROI. These structures, with lower Ca/N and P/N ratios, were connected and enveloped the bone graft granules. Cortical ROI revealed the most mineralized bone tissue. Conclusions: After 9 months, bone graft resorption was only partially completed and new bone tissue appeared less mineralized in the middle and apical ROI than in the coronal ROI.
Laser-Modified Surface Enhances Osseointegration and Biomechanical Anchorage of Commercially Pure Titanium Implants for Bone-Anchored Hearing Systems
Osseointegrated implants inserted in the temporal bone are a vital component of bone-anchored hearing systems (BAHS). Despite low implant failure levels, early loading protocols and simplified procedures necessitate the application of implants which promote bone formation, bone bonding and biomechanical stability. Here, screw-shaped, commercially pure titanium implants were selectively laser ablated within the thread valley using an Nd:YAG laser to produce a microtopography with a superimposed nanotexture and a thickened surface oxide layer. State-of-the-art machined implants served as controls. After eight weeks' implantation in rabbit tibiae, resonance frequency analysis (RFA) values increased from insertion to retrieval for both implant types, while removal torque (RTQ) measurements showed 153% higher biomechanical anchorage of the laser-modified implants. Comparably high bone area (BA) and bone-implant contact (BIC) were recorded for both implant types but with distinctly different failure patterns following biomechanical testing. Fracture lines appeared within the bone ~30-50 μm from the laser-modified surface, while separation occurred at the bone-implant interface for the machined surface. Strong correlations were found between RTQ and BIC and between RFA at retrieval and BA. In the endosteal threads, where all the bone had formed de novo, the extracellular matrix composition, the mineralised bone area and osteocyte densities were comparable for the two types of implant. Using resin cast etching, osteocyte canaliculi were observed directly approaching the laser-modified implant surface. Transmission electron microscopy showed canaliculi in close proximity to the laser-modified surface, in addition to a highly ordered arrangement of collagen fibrils aligned parallel to the implant surface contour. It is concluded that the physico-chemical surface properties of laser-modified surfaces (thicker oxide, micro- and nanoscale texture) promote bone bonding which may be of benefit in situations where large demands are imposed on biomechanically stable interfaces, such as in early loading and in compromised conditions.
Engineering immunomodulatory and osteoinductive implant surfaces via mussel adhesion-mediated ion coordination and molecular clicking
Immune response and new tissue formation are important aspects of tissue repair. However, only a single aspect is generally considered in previous biomedical interventions, and the synergistic effect is unclear. Here, a dual-effect coating with immobilized immunomodulatory metal ions (e.g., Zn 2+ ) and osteoinductive growth factors (e.g., BMP-2 peptide) is designed via mussel adhesion-mediated ion coordination and molecular clicking strategy. Compared to the bare TiO 2 group, Zn 2+ can increase M2 macrophage recruitment by up to 92.5% in vivo and upregulate the expression of M2 cytokine IL-10 by 84.5%; while the dual-effect of Zn 2+ and BMP-2 peptide can increase M2 macrophages recruitment by up to 124.7% in vivo and upregulate the expression of M2 cytokine IL-10 by 171%. These benefits eventually significantly enhance bone-implant mechanical fixation (203.3 N) and new bone ingrowth (82.1%) compared to the bare TiO 2 (98.6 N and 45.1%, respectively). Taken together, the dual-effect coating can be utilized to synergistically modulate the osteoimmune microenvironment at the bone-implant interface, enhancing bone regeneration for successful implantation. Immune response and new tissue formation are important aspects of tissue repair but often only one aspect is considered in biomedical interventions. Here, the authors report on the use of a mussel-like surface coating to immobilize immune modulating metal ions and growth factors and demonstrated improved in vivo outcomes.
Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants
Musculoskeletal disorders are becoming an ever-growing societal burden and, as a result, millions of bone replacements surgeries are performed per year worldwide. Despite total joint replacements being recognized among the most successful surgeries of the last century, implant failure rates exceeding 10% are still reported. These numbers highlight the necessity of technologies to provide an accurate monitoring of the bone–implant interface state. This study provides a detailed review of the most relevant methodologies and technologies already proposed to monitor the loosening states of endoprosthetic implants, as well as their performance and experimental validation. A total of forty-two papers describing both intracorporeal and extracorporeal technologies for cemented or cementless fixation were thoroughly analyzed. Thirty-eight technologies were identified, which are categorized into five methodologies: vibrometric, acoustic, bioelectric impedance, magnetic induction, and strain. Research efforts were mainly focused on vibrometric and acoustic technologies. Differently, approaches based on bioelectric impedance, magnetic induction and strain have been less explored. Although most technologies are noninvasive and are able to monitor different loosening stages of endoprosthetic implants, they are not able to provide effective monitoring during daily living of patients.
The effect of coating characteristics on implant-bone interface mechanics
Successful osseointegration of press-fit implants depends on the initial stability, often measured by the micromotions between the implant and bone. A good primary stability can be achieved by optimizing the compressive and frictional forces acting at the bone-implant interface. The frictional properties of the implant-bone interface, which depend on the roughness and porosity of the implant surface coating, can affect the primary stability. Several reversible (elastic) and non-reversible (permanent) deformation processes take place during frictional loading of the implant-bone interface. In case of a rough coating, the asperities of the implant surface are compressed into the bone leading to mechanical interlocking. To optimize fixation of orthopaedic implants it is crucial to understand these complex interactions between coating and bone. The objective of the current study was to gain more insight into the reversible and non-reversible processes acting at the implant-bone interface. Tribological experiments were performed with two types of porous coatings against human cadaveric bone. The results indicated that the coefficient of friction depended on the coating roughness (0.86, 0.95, and 0.45 for an Ra roughness of 41.2, 53.0, and a polished surface, respectively). Larger elastic and permanent displacements were found for the rougher coating, resulting in a lower interface stiffness. The experiments furthermore revealed that relative displacements of up to 35 µm can occur without sliding at the interface. These findings have implications for micromotion thresholds that currently are assumed for osseointegration, and suggest that bone ingrowth actually occurs in the absence of relative sliding at the implant-bone interface.
In vivo validation of damping capacity assessment as a diagnostic tool for peri-implant bone loss
This in vivo animal study aimed to evaluate the diagnostic reliability of a damping capacity assessment by correlating dental implant stability with peri-implant bone loss in a beagle dog model. Thirty-two bone-level implants were immediately placed in four beagle dogs without bone grafting. Implants were divided into platform switching and platform matching groups. Each implant was loaded with a superstructure after a 4-week healing period, followed by 8 weeks of functional loading. Damping capacity assessment and resonance frequency analysis were performed every 4 weeks. Peri-implant bone loss, supporting bone volume, and bone-to-implant contact were assessed using micro-CT and histological analysis. Two implants in the platform switching group failed during the study. Among the remaining 30 implants, final implant stability indices by damping capacity assessment ranged from 44 to 80. Peri-implant bone loss varied from 0.25 mm to 6.96 mm. A strong negative correlation was found between final stability indices and bone loss ( r = − 0.745; p  ≤ 0.0001). Supporting bone volume and bone-to-implant contact ratio showed significant positive correlations with implant stability. Damping capacity assessment demonstrated diagnostic relevance by reflecting peri-implant bone loss and the degree of osseointegration. However, its ability to detect early bone resorption is uncertain.
Electrical stimulation to promote osseointegration of bone anchoring implants: a topical review
Electrical stimulation has shown to be a promising approach for promoting osseointegration in bone anchoring implants, where osseointegration defines the biological bonding between the implant surface and bone tissue. Bone-anchored implants are used in the rehabilitation of hearing and limb loss, and extensively in edentulous patients. Inadequate osseointegration is one of the major factors of implant failure that could be prevented by accelerating or enhancing the osseointegration process by artificial means. In this article, we reviewed the efforts to enhance the biofunctionality at the bone-implant interface with electrical stimulation using the implant as an electrode. We reviewed articles describing different electrode configurations, power sources, and waveform-dependent stimulation parameters tested in various in vitro and in vivo models. In total 55 English-language and peer-reviewed publications were identified until April 2020 using PubMed, Google Scholar, and the Chalmers University of Technology Library discovery system using the keywords: osseointegration, electrical stimulation, direct current and titanium implant. Thirteen of those publications were within the scope of this review. We reviewed and compared studies from the last 45 years and found nonuniform protocols with disparities in cell type and animal model, implant location, experimental timeline, implant material, evaluation assays, and type of electrical stimulation. The reporting of stimulation parameters was also found to be inconsistent and incomplete throughout the literature. Studies using in vitro models showed that osteoblasts were sensitive to the magnitude of the electric field and duration of exposure, and such variables similarly affected bone quantity around implants in in vivo investigations. Most studies showed benefits of electrical stimulation in the underlying processes leading to osseointegration, and therefore we found the idea of promoting osseointegration by using electric fields to be supported by the available evidence. However, such an effect has not been demonstrated conclusively nor optimally in humans. We found that optimal stimulation parameters have not been thoroughly investigated and this remains an important step towards the clinical translation of this concept. In addition, there is a need for reporting standards to enable meta-analysis for evidence-based treatments.
Densification of cancellous bone with autologous particles can enhance the primary stability of uncemented implants by increasing the interface friction coefficient
Sufficient primary stability is one of the most important prerequisites for successful osseointegration of cementless implants. Bone grafts, densification and compaction methods have proven clinically successful, but the related effects and causes have not been systematically investigated. Postoperatively, the frictional properties of the bone-implant interface determine the amount of tolerable shear stress. Frictional properties of different implant surfaces have been widely studied. Less attention has been paid to the influence of host bone modifications. The purpose of this study was to investigate the influence of densification of cancellous bone with bone particles on the interface friction coefficient. Cancellous bone samples from femoral heads were densified with bone particles obtained during sample preparation. The densification was quantified using micro-Ct. Friction coefficients of the densified and paired native samples were determined. Densification increased the BV/TV in the first two millimeters of the bone samples by 10.5 ± 2.7% to 30.5 ± 2.7% (p < 0.001). The static friction coefficient was increased by 10.5 ± 6.1% to 0.43 ± 0.03. The static friction coefficient increased with higher BV/TV of the bone interface, which is represented by the top 2 mm of the bone. The increase in contact area, intertrabecular anchorage and particle bracing could be responsible for the increase in friction. Optimization of particle shape and size based on the patient’s individual bone microstructure could further increase frictional resistance. Bone densification has the potential to improve the primary stability of uncemented implants.
Biomechanical behavior of two different surface treatments on dental implants with healing chambers in osteoporotic rabbits: an experimental study
The aging global population is experiencing a growing prevalence of metabolic bone diseases, particularly osteoporosis, which compromises bone quality and poses challenges for dental implant osseointegration. Despite the systemic bone fragility associated with osteoporosis, the use of implants is not contraindicated, although it may be accompanied by increased risks. Recent advances in implant macrogeometry and surface treatment aim to enhance osseointegration in compromised bone conditions. This study aimed to biomechanically and histologically evaluate the performance of dental implants featuring healing chambers and two different surface treatments in an animal model with induced osteoporosis. Twenty female New Zealand white rabbits were used, with osteoporosis induced via ovariectomy and glucocorticoid administration. A total of 80 titanium implants (two surface types: Group A – titanium oxide-blasted; Group B – titanium oxide-blasted plus HCl-conditioned) were installed in both rabbit tibiae ( n  = 2 implant per tibia). Stability was measured by resonance frequency analysis (RFA) and maximum removal torque. Histological assessments included bone-to-implant contact (BIC%) and bone area fraction occupancy (BAFO%) at 14- and 28-days post-implantation. RFA revealed increased implant stability over time in both groups, with Group B showing significantly higher ISQ values in 28 days ( p  < 0.0001). Removal torque values also improved over time, with Group B showing significantly greater values at 28 days (30.1 ± 4.18 Ncm) compared to Group A (25.6 ± 3.95 Ncm). Histomorphometric analysis showed that BAFO% was significantly greater in Group B at 28 days, but no significant differences in BIC% were observed between groups at either time point. Within the limitations of this animal model, implants with acid-etched surfaces showed improved biomechanical stability and bone occupancy at later healing stages, but only at 28 days. These results suggest that surface modifications may play a role in enhancing osseointegration over time in compromised bone environments. However, the findings are limited to this preclinical model and do not allow direct clinical extrapolation.