Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
973
result(s) for
"brain–computer interface (BCI)"
Sort by:
A hybrid PDMS-Parylene subdural multi-electrode array
by
Ziaie, Babak
,
Wei, Pinghung
,
Otto, Kevin J.
in
Animals
,
Biological and Medical Physics
,
Biomedical engineering
2013
In this paper, we report on a cost effective and simple method for fabricating a flexible multi-electrode array for subdural neural recording. The electrode was fabricated using a PDMS-Parylene bilayer to combine the major advantages of both materials. Mechanical and electrical characterizations were performed to confirm functionality of a 16-site electrode array under various flexed/bent conditions. The electrode array was helically wound around a 3 mm diameter cylindrical tube and laid over a 2 cm diameter sphere while maintaining its recording capability. Experimental results showed impedance values between 300 kΩ and 600 kΩ at 1 kHz for 90 μm diameter gold recording sites. Acoustically evoked neural activity was successfully recorded from rat auditory cortex, confirming
in vivo
functionality.
Journal Article
Stable Decoding from a Speech BCI Enables Control for an Individual with ALS without Recalibration for 3 Months
by
Weiss, Alexander R.
,
Angrick, Miguel
,
Milsap, Griffin W.
in
Accuracy
,
Amyotrophic lateral sclerosis
,
amyotrophic lateral sclerosis (ALS)
2023
Brain‐computer interfaces (BCIs) can be used to control assistive devices by patients with neurological disorders like amyotrophic lateral sclerosis (ALS) that limit speech and movement. For assistive control, it is desirable for BCI systems to be accurate and reliable, preferably with minimal setup time. In this study, a participant with severe dysarthria due to ALS operates computer applications with six intuitive speech commands via a chronic electrocorticographic (ECoG) implant over the ventral sensorimotor cortex. Speech commands are accurately detected and decoded (median accuracy: 90.59%) throughout a 3‐month study period without model retraining or recalibration. Use of the BCI does not require exogenous timing cues, enabling the participant to issue self‐paced commands at will. These results demonstrate that a chronically implanted ECoG‐based speech BCI can reliably control assistive devices over long time periods with only initial model training and calibration, supporting the feasibility of unassisted home use. A speech brain‐computer interface enables a clinical‐trial participant with amyotrophic lateral sclerosis to control a communication board and home devices without model retraining or baseline calibration. Six intuitive speech commands are accurately detected and decoded (median accuracy: 90.59%) from a chronic electrocorticographic (ECoG) implant over the ventral sensorimotor cortex throughout a 3‐month study period.
Journal Article
Brain–Computer Interface Spellers: A Review
by
Saboor, Abdul
,
Volosyak, Ivan
,
Rezeika, Aya
in
Brain
,
Brain–Computer Interface (BCI)
,
Computer applications
2018
A Brain–Computer Interface (BCI) provides a novel non-muscular communication method via brain signals. A BCI-speller can be considered as one of the first published BCI applications and has opened the gate for many advances in the field. Although many BCI-spellers have been developed during the last few decades, to our knowledge, no reviews have described the different spellers proposed and studied in this vital field. The presented speller systems are categorized according to major BCI paradigms: P300, steady-state visual evoked potential (SSVEP), and motor imagery (MI). Different BCI paradigms require specific electroencephalogram (EEG) signal features and lead to the development of appropriate Graphical User Interfaces (GUIs). The purpose of this review is to consolidate the most successful BCI-spellers published since 2010, while mentioning some other older systems which were built explicitly for spelling purposes. We aim to assist researchers and concerned individuals in the field by illustrating the highlights of different spellers and presenting them in one review. It is almost impossible to carry out an objective comparison between different spellers, as each has its variables, parameters, and conditions. However, the gathered information and the provided taxonomy about different BCI-spellers can be helpful, as it could identify suitable systems for first-hand users, as well as opportunities of development and learning from previous studies for BCI researchers.
Journal Article
Recognition of EEG Signals from Imagined Vowels Using Deep Learning Methods
by
Collazos, Ana Claros
,
Rodríguez, Jan Bacca
,
López, Omar
in
Accuracy
,
Algorithms
,
Artificial intelligence
2021
The use of imagined speech with electroencephalographic (EEG) signals is a promising field of brain-computer interfaces (BCI) that seeks communication between areas of the cerebral cortex related to language and devices or machines. However, the complexity of this brain process makes the analysis and classification of this type of signals a relevant topic of research. The goals of this study were: to develop a new algorithm based on Deep Learning (DL), referred to as CNNeeg1-1, to recognize EEG signals in imagined vowel tasks; to create an imagined speech database with 50 subjects specialized in imagined vowels from the Spanish language (/a/,/e/,/i/,/o/,/u/); and to contrast the performance of the CNNeeg1-1 algorithm with the DL Shallow CNN and EEGNet benchmark algorithms using an open access database (BD1) and the newly developed database (BD2). In this study, a mixed variance analysis of variance was conducted to assess the intra-subject and inter-subject training of the proposed algorithms. The results show that for intra-subject training analysis, the best performance among the Shallow CNN, EEGNet, and CNNeeg1-1 methods in classifying imagined vowels (/a/,/e/,/i/,/o/,/u/) was exhibited by CNNeeg1-1, with an accuracy of 65.62% for BD1 database and 85.66% for BD2 database.
Journal Article
Neurophysiological predictor of SMR-based BCI performance
2010
Brain–computer interfaces (BCIs) allow a user to control a computer application by brain activity as measured, e.g., by electroencephalography (EEG). After about 30years of BCI research, the success of control that is achieved by means of a BCI system still greatly varies between subjects. For about 20% of potential users the obtained accuracy does not reach the level criterion, meaning that BCI control is not accurate enough to control an application. The determination of factors that may serve to predict BCI performance, and the development of methods to quantify a predictor value from psychological and/or physiological data serve two purposes: a better understanding of the ‘BCI-illiteracy phenomenon’, and avoidance of a costly and eventually frustrating training procedure for participants who might not obtain BCI control. Furthermore, such predictors may lead to approaches to antagonize BCI illiteracy. Here, we propose a neurophysiological predictor of BCI performance which can be determined from a two minute recording of a ‘relax with eyes open’ condition using two Laplacian EEG channels. A correlation of r=0.53 between the proposed predictor and BCI feedback performance was obtained on a large data base with N=80 BCI-naive participants in their first session with the Berlin brain–computer interface (BBCI) system which operates on modulations of sensory motor rhythms (SMRs).
Journal Article
Real-time EEG feedback during simultaneous EEG–fMRI identifies the cortical signature of motor imagery
2015
Motor imagery (MI) combined with real-time electroencephalogram (EEG) feedback is a popular approach for steering brain–computer interfaces (BCI). MI BCI has been considered promising as add-on therapy to support motor recovery after stroke. Yet whether EEG neurofeedback indeed targets specific sensorimotor activation patterns cannot be unambiguously inferred from EEG alone. We combined MI EEG neurofeedback with concurrent and continuous functional magnetic resonance imaging (fMRI) to characterize the relationship between MI EEG neurofeedback and activation in cortical sensorimotor areas. EEG signals were corrected online from interfering MRI gradient and ballistocardiogram artifacts, enabling the delivery of real-time EEG feedback. Significantly enhanced task-specific brain activity during feedback compared to no feedback blocks was present in EEG and fMRI. Moreover, the contralateral MI related decrease in EEG sensorimotor rhythm amplitude correlated inversely with fMRI activation in the contralateral sensorimotor areas, whereas a lateralized fMRI pattern did not necessarily go along with a lateralized EEG pattern. Together, the findings indicate a complex relationship between MI EEG signals and sensorimotor cortical activity, whereby both are similarly modulated by EEG neurofeedback. This finding supports the potential of MI EEG neurofeedback for motor rehabilitation and helps to better understand individual differences in MI BCI performance.
•Real-time EEG feedback during continuous fMRI is possible for motor imagery.•EEG feedback enhances task-related activity in EEG and the feedback independent fMRI.•BCI illiterates can be divided into real and pseudo BCI illiterates.
Journal Article
Cortical effects of user training in a motor imagery based brain–computer interface measured by fNIRS and EEG
2014
The present study aims to gain insights into the effects of training with a motor imagery (MI)-based brain–computer interface (BCI) on activation patterns of the sensorimotor cortex. We used functional near-infrared spectroscopy (fNIRS) and electroencephalography (EEG) to investigate long-term training effects across 10 sessions using a 2-class (right hand and feet) MI-based BCI in fifteen subjects. In the course of the training a significant enhancement of activation pattern emerges, represented by an [oxy-Hb] increase in fNIRS and a stronger event-related desynchronization in the upper β-frequency band in the EEG. These effects were only visible in participants with relatively low BCI performance (mean accuracy≤70%). We found that training with an MI-based BCI affects cortical activation patterns especially in users with low BCI performance.
Our results may serve as a valuable contribution to the field of BCI research and provide information about the effects that training with an MI-based BCI has on cortical activation patterns. This might be useful for clinical applications of BCI which aim at promoting and guiding neuroplasticity.
•Effects of brain–computer interface (BCI) training were investigated.•Cortical activation patterns of motor imagery (MI) training were long-term monitored.•Functional near-infrared spectroscopy (fNIRS) and EEG were used.•MI based BCI training affects cortical activation patterns.•Effects were found especially in users with low BCI performance.
Journal Article
Mind over chatter: Plastic up-regulation of the fMRI salience network directly after EEG neurofeedback
2013
Neurofeedback (NFB) involves a brain–computer interface that allows users to learn to voluntarily control their cortical oscillations, reflected in the electroencephalogram (EEG). Although NFB is being pioneered as a noninvasive tool for treating brain disorders, there is insufficient evidence on the mechanism of its impact on brain function. Furthermore, the dominant rhythm of the human brain is the alpha oscillation (8–12Hz), yet its behavioral significance remains multifaceted and largely correlative. In this study with 34 healthy participants, we examined whether during the performance of an attentional task, the functional connectivity of distinct fMRI networks would be plastically altered after a 30-min session of voluntary reduction of alpha rhythm (n=17) versus a sham-feedback condition (n=17). We reveal that compared to sham-feedback, NFB induced an increase of connectivity within regions of the salience network involved in intrinsic alertness (dorsal anterior cingulate), which was detectable 30min after termination of training. The increase in salience network (default-mode network) connectivity was negatively (positively) correlated with changes in ‘on task’ mind-wandering as well as resting state alpha rhythm. Crucially, we observed a causal dependence between alpha rhythm synchronization during NFB and its subsequent change at resting state, not exhibited by the SHAM group. Our findings provide neurobehavioral evidence for the brain's exquisite functional plasticity, and for a temporally direct impact of NFB on a key cognitive control network, suggesting a promising basis for its use to treat cognitive disorders under physiological conditions.
► Alpha (8–12Hz) synchronisation was reduced via EEG neurofeedback. ► Increased fMRI salience network connectivity was found during an oddball task. ► Dorsal ACC connectivity changes inversely correlated with resting EEG alpha changes. ► dACC/resting alpha changes inversely correlated with mind-wandering changes. ► The effect on cortical plasticity was evident 30 minutes after neurofeedback.
Journal Article
Multi-Kernel Temporal and Spatial Convolution for EEG-Based Emotion Classification
2022
Deep learning using an end-to-end convolutional neural network (ConvNet) has been applied to several electroencephalography (EEG)-based brain–computer interface tasks to extract feature maps and classify the target output. However, the EEG analysis remains challenging since it requires consideration of various architectural design components that influence the representational ability of extracted features. This study proposes an EEG-based emotion classification model called the multi-kernel temporal and spatial convolution network (MultiT-S ConvNet). The multi-scale kernel is used in the model to learn various time resolutions, and separable convolutions are applied to find related spatial patterns. In addition, we enhanced both the temporal and spatial filters with a lightweight gating mechanism. To validate the performance and classification accuracy of MultiT-S ConvNet, we conduct subject-dependent and subject-independent experiments on EEG-based emotion datasets: DEAP and SEED. Compared with existing methods, MultiT-S ConvNet outperforms with higher accuracy results and a few trainable parameters. Moreover, the proposed multi-scale module in temporal filtering enables extracting a wide range of EEG representations, covering short- to long-wavelength components. This module could be further implemented in any model of EEG-based convolution networks, and its ability potentially improves the model’s learning capacity.
Journal Article
Direct Electrical Stimulation in Electrocorticographic Brain–Computer Interfaces: Enabling Technologies for Input to Cortex
by
Caldwell, David J.
,
Ojemann, Jeffrey G.
,
Rao, Rajesh P. N.
in
Brain research
,
brain–computer interface (BCI)
,
Computational neuroscience
2019
Electrocorticographic brain computer interfaces (ECoG-BCIs) offer tremendous opportunities for restoring function in individuals suffering from neurological damage and for advancing basic neuroscience knowledge. ECoG electrodes are already commonly used clinically for monitoring epilepsy and have greater spatial specificity in recording neuronal activity than techniques such as electroencephalography (EEG). Much work to date in the field has focused on using ECoG signals recorded from cortex as control outputs for driving end effectors. An equally important but less explored application of an ECoG-BCI is directing input into cortex using ECoG electrodes for direct electrical stimulation (DES). Combining DES with ECoG recording enables a truly bidirectional BCI, where information is both read from and written to the brain. We discuss the advantages and opportunities, as well as the barriers and challenges presented by using DES in an ECoG-BCI. In this article, we review ECoG electrodes, the physics and physiology of DES, and the use of electrical stimulation of the brain for the clinical treatment of disorders such as epilepsy and Parkinson's disease. We briefly discuss some of the translational, regulatory, financial, and ethical concerns regarding ECoG-BCIs. Next, we describe the use of ECoG-based DES for providing sensory feedback and for probing and modifying cortical connectivity. We explore future directions, which may draw on invasive animal studies with penetrating and surface electrodes as well as non-invasive stimulation methods such as transcranial magnetic stimulation (TMS). We conclude by describing enabling technologies, such as smaller ECoG electrodes for more precise targeting of cortical areas, signal processing strategies for simultaneous stimulation and recording, and computational modeling and algorithms for tailoring stimulation to each individual brain.
Journal Article