Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
143 result(s) for "carbon-11"
Sort by:
Reactive Palladium–Ligand Complexes for sup.11C-Carbonylation at Ambient Pressure: A Breakthrough in Carbon-11 Chemistry
The Pd–Xantphos-mediated [sup.11] C-carbonylation protocol (also known as the “Xantphos- method”), due to its simplistic and convenient nature, has facilitated researchers in meeting a longstanding need for preparing [sup.11] C-carbonyl-labeled radiopharmaceuticals at ambient pressure for positron emission tomography (PET) imaging and drug discovery. This development could be viewed as a breakthrough in carbon-11 chemistry, as evidenced by the rapid global adoption of the method by the pharmaceutical industry and academic laboratories worldwide. The method has been fully automated for the good manufacturing practice (GMP)-compliant production of novel radiopharmaceuticals for human use, and it has been adapted for “in-loop” reactions and microwave technology; an impressive number of [sup.11] C-labeled compounds (>100) have been synthesized. Given the simplicity and efficiency of the method, as well as the abundance of carbonyl groups in bioactive drug molecules, we expect that this methodology will be even more widely adopted in future PET radiopharmaceutical research and drug development.
PET Molecular Imaging in Drug Development: The Imaging and Chemistry Perspective
Positron emission tomography with selective radioligands advances the drug discovery and development process by revealing information about target engagement, proof of mechanism, pharmacokinetic and pharmacodynamic profiles. Positron emission tomography (PET) is an essential and highly significant tool to study therapeutic drug development, dose regimen, and the drug plasma concentrations of new drug candidates. Selective radioligands bring up target-specific information in several disease states including cancer, cardiovascular, and neurological conditions by quantifying various rates of biological processes with PET, which are associated with its physiological changes in living subjects, thus it reveals disease progression and also advances the clinical investigation. This study explores the major roles, applications, and advances of PET molecular imaging in drug discovery and development process with a wide range of radiochemistry as well as clinical outcomes of positron-emitting carbon-11 and fluorine-18 radiotracers.
Recent Developments in Carbon-11 Chemistry and Applications for First-In-Human PET Studies
Positron emission tomography (PET) is a molecular imaging technique that makes use of radiolabelled molecules for in vivo evaluation. Carbon-11 is a frequently used radionuclide for the labelling of small molecule PET tracers and can be incorporated into organic molecules without changing their physicochemical properties. While the short half-life of carbon-11 (11C; t½ = 20.4 min) offers other advantages for imaging including multiple PET scans in the same subject on the same day, its use is limited to facilities that have an on-site cyclotron, and the radiochemical transformations are consequently more restrictive. Many researchers have embraced this challenge by discovering novel carbon-11 radiolabelling methodologies to broaden the synthetic versatility of this radionuclide. This review presents new carbon-11 building blocks and radiochemical transformations as well as PET tracers that have advanced to first-in-human studies over the past five years.
Performance of PET imaging for the localization of epileptogenic zone in patients with epilepsy: a meta-analysis
Objectives The aim of this meta-analysis was to estimate the clinical use value of 11 C-FMZ and 18 F-FDG in PET for the localization of epileptogenic zone and to provide evidence for practitioners’ clinical decision-making. Methods We searched PubMed and Embase in a time frame from inception to May 31, 2020. Studies utilizing FMZ or FDG-PET or FDG-PET/MRI used in patients with epilepsy, with EEG or surgical outcomes as the gold standard and corresponding outcomes such as concordance rates of PET or PET/MRI scan compared with reference standard, absolute numbers of participants with true-positive (TP), false-positive (FP), true-negative (TN), and false-negative (FN) results in FDG or FMZ PET. Pooled concordance rates, overall sensitivity, and specificity of 11 C-FMZ-PET and 18 F-FDG-PET were calculated. Results In total, 44 studies met the inclusion criteria. The pooled concordance rates of FDG-PET, FMZ-PET, and FDG-PET/MRI coregistration compared with reference standard were 0.67 (95% CI: 0.60–0.73), 0.75 (95% CI: 0.57–0.93), and 0.93 (95% CI: 0.89–0.97), respectively. The concordance rate of 18 F-FDG-PET in patients with temporal lobe epilepsy (TLE) was 0.79 (0.63; 0.92). The overall sensitivity and specificity of 18 F-FDG-PET were 0.66 (95% CI: 0.58–0.73) and 0.71 (95% CI: 0.63–0.78), respectively. 11 C-FMZ-PET displayed an overall sensitivity of 0.62 (95% CI: 0.49–0.73) and specificity of 0.73 (95% CI: 0.59–0.84). Conclusions Both 11 C-FMZ PET and 18 F-FDG PET are the choice of modalities for the localization of epileptogenic zone, especially when coregistered with MRI. Key Points • 11 C-FMZ-PET may be more helpful than 18 F-FDG-PET in the localization of epilepsy foci. • Coregistration of FDG-PET and MRI is recommended in the localization of epileptogenic zone.
Radiosynthesis and In Vitro Evaluation of 11Ctozadenant as Adenosine A2A Receptor Radioligand
Tozadenant (4-hydroxy-N-(4-methoxy-7-morpholinobenzo[d]thiazol-2-yl)-4-methylpiperidine-1-carboxamide) is a highly selective adenosine A2A receptor (A2AR) antagonist and a promising lead structure for the development of A2AR-selective positron emission tomography (PET) probes. Although several 18F-labelled tozadenant derivatives showed favorable in vitro properties, recent in vivo PET studies observed poor brain penetration and lower specific binding than anticipated from the in vitro data. While these findings might be attributable to the structural modification associated with 18F-labelling, they could also reflect inherent properties of the parent compound. However, PET studies with radioisotopologues of tozadenant to evaluate its cerebral pharmacokinetics and brain distribution are still lacking. In the present work, we applied N-Boc-O-desmethyltozadenant as a suitable precursor for the preparation of [O-methyl-11C]tozadenant ([11C]tozadenant) by O-methylation with [11C]methyl iodide followed by acidic deprotection. This approach afforded [11C]tozadenant in radiochemical yields of 18 ± 2%, with molar activities of 50–60 GBq/µmol (1300–1600 mCi/µmol) and radiochemical purities of 95 ± 3%. In addition, in vitro autoradiography in pig and rat brain slices demonstrated the expected striatal accumulation pattern and confirmed the A2AR specificity of the radioligand, making it a promising tool for in vivo PET studies on the cerebral pharmacokinetics and brain distribution of tozadenant.
Carbon-11 Production: Communication, Operations, Maintenance, Troubleshooting, and Analysis for Maintaining High-Grade Bombardment and Provisions of 11 CCarbon Dioxide and Its Conversion to 11 CMethyl Iodide
Incorporation of carbon-11 radiotracers for positron emission tomography (PET) imaging requires close coordination between cyclotron operation, radiochemistry production, quality control, and clinical administration. A persistent challenge exists is the minimization of the carbon-12 isotopologue mass of the radiotracer, which reduces molar activity and can compromise PET image quality. This challenge can be particularly acute at facilities where cyclotron operation and carbon-11 radiochemistry are realized by separate organizations with distinct operational priorities. Here, we describe how the Radiochemistry Group at New York University Grossman School of Medicine and Siemens Healthineers have developed an integrated operational framework for consistent, high-quality carbon-11 production within an academic-industry partnership. Cyclotron target maintenance and conditioning protocols, remote chemistry module maintenance schedules, a validated radio-HPLC method (UV LOD = 0.9 µg/mL, UV LOQ = 3.0 µg/mL) for trending methyl iodide isotopologue mass, and structured inter-team communication protocols are presented in this manuscript. Quality analysis demonstrates molar activities consistently exceeding the recommended minimum of 40 GBq/µmol for reversibly binding radiotracers used in human PET studies. This work is intended as a practical resource for radiochemists, cyclotron engineers, and facility managers working to establish or improve institutional carbon-11 programs.
In vivo quantitative imaging of photoassimilate transport dynamics and allocation in large plants using a commercial positron emission tomography (PET) scanner
Background Although important aspects of whole-plant carbon allocation in crop plants (e.g., to grain) occur late in development when the plants are large, techniques to study carbon transport and allocation processes have not been adapted for large plants. Positron emission tomography (PET), developed for dynamic imaging in medicine, has been applied in plant studies to measure the transport and allocation patterns of carbohydrates, nutrients, and phytohormones labeled with positron-emitting radioisotopes. However, the cost of PET and its limitation to smaller plants has restricted its use in plant biology. Here we describe the adaptation and optimization of a commercial clinical PET scanner to measure transport dynamics and allocation patterns of 11 C-photoassimilates in large crops. Results Based on measurements of a phantom, we optimized instrument settings, including use of 3-D mode and attenuation correction to maximize the accuracy of measurements. To demonstrate the utility of PET, we measured 11 C-photoassimilate transport and allocation in Sorghum bicolor , an important staple crop, at vegetative and reproductive stages (40 and 70 days after planting; DAP). The 11 C-photoassimilate transport speed did not change over the two developmental stages. However, within a stem, transport speeds were reduced across nodes, likely due to higher 11 C-photoassimilate unloading in the nodes. Photosynthesis in leaves and the amount of 11 C that was exported to the rest of the plant decreased as plants matured. In young plants, exported 11 C was allocated mostly (88 %) to the roots and stem, but in flowering plants (70 DAP) the majority of the exported 11 C (64 %) was allocated to the apex. Conclusions Our results show that commercial PET scanners can be used reliably to measure whole-plant C-allocation in large plants nondestructively including, importantly, allocation to roots in soil. This capability revealed extreme changes in carbon allocation in sorghum plants, as they advanced to maturity. Further, our results suggest that nodes may be important control points for photoassimilate distribution in crops of the family Poaceae. Quantifying real-time carbon allocation and photoassimilate transport dynamics, as demonstrated here, will be important for functional genomic studies to unravel the mechanisms controlling phloem transport in large crop plants, which will provide crucial insights for improving yields.
Treatments with Liquid Smoke and Certain Chemical Constituents Prevalent in Smoke Reduce Phloem Vascular Sectoriality in the Sunflower with Improvement to Growth
Many higher plants possess a physiological organization that is based upon the carbon economy of their parts. While photosynthates are partitioned according to the relative strength of the plant’s sink tissues, in many species there is also a very close relationship between partitioning, phyllotaxy and vascular connectivity giving rise to sectorial patterns of allocation. Here, we examined the influence of smoke and certain chemical constituents prevalent in smoke including, catechol, resorcinol and hydroquinone on phloem vascular sectoriality in common sunflower (Helianthis annuus L.), as a model plant for sectoriality. By administering radioactive carbon-11 to a single source leaf as 11CO2, 11C-photosynthate allocation patterns were examined using autoradiography. A 1:200 aqueous dilution of liquid smoke treated soil caused 2.6-fold and 2.5-fold reductions in phloem sectoriality in sink leaves and roots, respectively. Treatment with catechol (1,2-d ihydroxybenzene) or resorcinol (1,3-dihydroxybenzene), polyphenolic constituents that are prevalent in smoke, caused similar reductions in phloem sectoriality in the same targeted sink tissues. However, treatment with hydroquinone (1,4-dihydroxybenzene) had no effect. Finally, the longer-term effects of smoke exposure on plant growth and performance were examined using outdoor potted plants grown over the 2022 season. Plants exposed to liquid smoke treatments of the soil on a weekly basis had larger thicker leaves possessing 35% greater lignin content than untreated control plants. They also had thicker stems although the lignin content was the same as controls. Additionally, plants exposed to treatment produced twice the number of flowers with no difference in their disk floret diameters as untreated controls. Altogether, loss of phloem sectoriality from exposure to liquid smoke in the sunflower model benefited plant performance.
Gas Phase Transformations in Carbon-11 Chemistry
The short-lived positron-emitter carbon-11 (t1/2 = 20.4 min; β+, 99.8%) is prominent for labeling tracers for use in biomedical research with positron emission tomography (PET). Carbon-11 is produced for this purpose with a cyclotron, nowadays almost exclusively by the 14N(p,α)11C nuclear reaction, either on nitrogen containing a low concentration of oxygen (0.1–0.5%) or hydrogen (~5%) to produce [11C]carbon dioxide or [11C]methane, respectively. These primary radioactive products can be produced in high yields and with high molar activities. However, only [11C]carbon dioxide has some utility for directly labeling PET tracers. Primary products are required to be converted rapidly and efficiently into secondary labeling synthons to provide versatile radiochemistry for labeling diverse tracer chemotypes at molecular positions of choice. This review surveys known gas phase transformations of carbon-11 and summarizes the important roles that many of these transformations now play for producing a broad range of labeling synthons in carbon-11 chemistry.
Radiocarbon Flux Measurements Provide Insight into Why a Pyroligneous Acid Product Stimulates Plant Growth
Agriculture in the 21st century faces many formidable challenges with the growing global population. Increasing demands on the planet’s natural resources already tax existing agricultural practices. Today, many farmers are using biochemical treatments to improve their yields. Commercialized organic biostimulants exist in the form of pyroligneous acid generated by burning agricultural waste products. Recently, we examined the mechanisms through which a commercial pyroligneous acid product, Coriphol™, manufactured by Corigin Solutions, Inc., stimulates plant growth. During the 2023 growing season, outdoor studies were conducted in soybean to examine the effects of different Coriphol™ treatment concentrations on plant growth. Plant height, number of leaves, and leaf size were positively impacted in a dose-dependent manner with 2 gallon/acre soil treatments being optimal. At harvest, this level of treatment boosted crop yield by 40%. To gain an understanding of why Coriphol™ improves plant fitness, follow-up laboratory-based studies were conducted using radiocarbon flux analysis. Here, radioactive 11CO2 was administered to live plants and comparisons were made between untreated soybean plants and plants treated at an equivalent Coriphol™ dose of 2 gallons/acre. Leaf metabolites were analyzed using radio-high-performance liquid chromatography for [11C]-chlorophyll (Chl) a and b components, as well as [11C]-β-carotene (β-Car) where fractional yields were used to calculate metabolic rates of synthesis. Altogether, Coriphol™ treatment boosted rates of Chl a, Chl b, and β-Car biosynthesis 3-fold, 2.6-fold, and 4.7-fold, respectively, and also increased their metabolic turnover 2.2-fold, 2.1-fold, and 3.9-fold, respectively. Also, the Chl a/b ratio increased from 3.1 to 3.4 with treatment. Altogether, these effects contributed to a 13.8% increase in leaf carbon capture.