Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
70 result(s) for "fetal ECG"
Sort by:
Automated Extraction of Fetal ECG Signal Features Using Twinned Filter and Integrated Methodologies
Nowadays, detecting fetal electrocardiogram (FECG) signals from a mother’s abdominal region is considered a most challenging task because of the high maternal overlapping and fetal signals at this location. Different existing FECG signal extraction techniques have been emphasized for extracting fetal ECG signal features. However, the noises present in the fetal signals still affect the overall performance; also, there is a high chance of missing waveforms and degraded signal-to-noise ratio (SNR) performance. This work proposes a novel extraction and detection technique to overcome these issues. At the initial stage, the FECG signals are collected from two datasets the abdominal and direct fetal ECG database and the Noninvasive fetal ECG database. The signals in the raw dataset with high noises are pre-processed using the twinned Savitzky-Golay filtering (Twin_SGF) model that can effectively enhance the SNR performance. After pre-processing, the FECG signals are fed into the feature extraction technique named Q-Integrated rapid-tune wavelet transform with independent component analysis (Q-IWavCA) to extract essential features from FECG signals. In addition, key characteristic information can be analyzed using the Extreme wavelet genre method (X_WavG) technique. This technique can detect P, T, QRS and ST segments effectively. The performance of a proposed method is analyzed via the MATLAB platform. The effectiveness of the proposed approach is proved by comparing it with different existing approaches in terms of sensitivity (99.3 and 99.5%), positive predictive value (PPV) (99.6 and 99.4%), F-measure (99.2 and 99.54%) are obtained for ADFECG dataset and NIFECG dataset correspondingly.
Non-Adaptive Methods of Fetal ECG Signal Processing
Abdominal fetal ElectroCardioGrams (fECGs) carry a wealth of information about the fetus including fetal Heart Rate (fHR) and signal morphology during different stages of pregnancy. Here we report our results on the implementation and evaluation of two non-adaptive signal processing methods suitable for fECG signal extraction, namely: the Independent Component Analysis (ICA) and the Principal Component Analysis (PCA) Methods. We used the fetal heart rate extracted from fECG signals (in Beats Per Minute - BPM) and Signal-to-Noise Ratio (SNR) as effective performance evaluation metrics for our applied methods. Our findings demonstrated that given adequate SNR, these methods produced excellent results in accurate determination of fHR. Furthermore, we found out that compared to the PCA Method, the ICA Method produces a lower variance in the detection of the fHR.
Enhancement of low-quality fetal electrocardiogram based on time-sequenced adaptive filtering
Extraction of a clean fetal electrocardiogram (ECG) from non-invasive abdominal recordings is one of the biggest challenges in fetal monitoring. An ECG allows for the interpretation of the electrical heart activity beyond the heart rate and heart rate variability. However, the low signal quality of the fetal ECG hinders the morphological analysis of its waveform in clinical practice. The time-sequenced adaptive filter has been proposed for performing optimal time-varying filtering of non-stationary signals having a recurring statistical character. In our study, the time-sequenced adaptive filter is applied to enhance the quality of multichannel fetal ECG after the maternal ECG is removed. To improve the performance of the filter in cases of low signal-to-noise ratio (SNR), we enhance the ECG reference signals by averaging consecutive ECG complexes. The performance of the proposed augmented time-sequenced adaptive filter is evaluated in both synthetic and real data from PhysioNet. This evaluation shows that the suggested algorithm clearly outperforms other ECG enhancement methods, in terms of uncovering the ECG waveform, even in cases with very low SNR. With the presented method, quality of the fetal ECG morphology can be enhanced to the extent that the ECG might be fit for use in clinical diagnostics.
Non-invasive Single Channel integration model for fetal ECG extraction and sustainable fetal healthcare using wavelet framework
A retrospective aspect of prenatal complexities during pregnancy and advancements in technology shows the need for unscathed fetal ECG extraction from a single mother abdominal ECG (abdECG). The proposed work introduces a Non-invasive Single Channel Integration Technique (NSCIT) depicting a cumulative trapezoidal mathematical model with an LMS adaptive algorithm for mother and fetal ECG extraction with improved Signal-to-Noise Ratio (SNR). Besides separation, fetal ECG (fECG) features are extracted, simulated, analyzed, and compared with standards to generate fetus cardiac growth during later Gestation Period (GP) of 21st to 40th week of pregnancy. The variants of the wavelet transform, such as Dual-Tree Complex Wavelet Transform (DTCWT) for pre-processing and Maximal Overlap Discrete Wavelet Transform (MODWT) for post-processing, are exploited using a multi-resolution analysis. The NSCIT algorithm with LMS adaptive technique has shown 100% accuracy for detecting mother ECG and specific fetal ECG extraction channels. The improved accuracy using abdominal lead 4 is 96.36%, and overall abdominal mixed lead accuracy is 93.32% compared with recent existing literature. The maximum error in comparing Power Spectral Density (PSD) of actual and extracted fECG and mECG is significantly less. The calculated correlation coefficient between actual and extracted fetal QRS width, fetal R-peak intervals (R-R), and fetal heart rate (fHR) for Db1 are 0.70, 0.99, and 0.67, respectively. The research outcomes show that fECG SNR increases with GP, and it is maximum for the GP of 40th week. This fECG morphological analysis before childbirth will efficaciously contribute to sustainable fetal healthcare. Highlights • Cumulative trapezoidal with the least mean square (LMS) adaptive filter as the separation technique of mother and fetal ECG. • Dual-tree complex wavelet transform (DTCWT) as a pre-processing technique. • The influence of the Gestation Period (GP) on improved SNR of fetal ECG. • Extracting and analyzing fetal morphological parameters using the maximal overlap discrete wavelet transform (MODWT). • Research has verified in the Physiobank public databases, namely, Abdominal and Direct fetal ECG database(adfecgdb) and non-invasive Fetal ECG Database (nifecgdb).
Fetal Electrocardiogram Extraction from the Mother’s Abdominal Signal Using the Ensemble Kalman Filter
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i.e., in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed extended Kalman filter (EKF) based algorithm.
Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms
This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size μ and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring. The optimization algorithm is driven by considering the ECG electrode positions on the maternal body surface in improving the performance of these adaptive filters. The main criterion for optimal parameter selection was the Signal-to-Noise Ratio (SNR). We conducted experiments using signals supplied by the latest version of our LabVIEW-Based Multi-Channel Non-Invasive Abdominal Maternal-Fetal Electrocardiogram Signal Generator, which provides the flexibility and capability of modeling the principal distribution of maternal/fetal ECGs in the human body. Our novel algorithm enabled us to find the optimal settings of the adaptive filters based on maternal surface ECG electrode placements. The experimental results further confirmed the theoretical assumption that the optimal settings of these adaptive filters are dependent on the ECG electrode positions on the maternal body, and therefore, we were able to achieve far better results than without the use of optimization. These improvements in turn could lead to a more accurate detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing. Ultimately, diagnostic-grade fetal ECG signals would ensure the reliable detection of fetal hypoxia.
Fetal Electrocardiogram Signal Extraction Based on Fast Independent Component Analysis and Singular Value Decomposition
Fetal electrocardiograms (FECGs) provide important clinical information for early diagnosis and intervention. However, FECG signals are extremely weak and are greatly influenced by noises. FECG signal extraction and detection are still challenging. In this work, we combined the fast independent component analysis (FastICA) algorithm with singular value decomposition (SVD) to extract FECG signals. The improved wavelet mode maximum method was applied to detect QRS waves and ST segments of FECG signals. We used the abdominal and direct fetal ECG database (ADFECGDB) and the Cardiology Challenge Database (PhysioNet2013) to verify the proposed algorithm. The signal-to-noise ratio of the best channel signal reached 45.028 dB and the issue of missing waveforms was addressed. The sensitivity, positive predictive value and F1 score of fetal QRS wave detection were 96.90%, 98.23%, and 95.24%, respectively. The proposed algorithm may be used as a new method for FECG signal extraction and detection.
A Comparison of Single Channel Fetal ECG Extraction Methods
The abdominal electrocardiogram (ECG) provides a non-invasive method for monitoring the fetal cardiac activity in pregnant women. However, the temporal and frequency overlap between the fetal ECG (FECG), the maternal ECG (MECG) and noise results in a challenging source separation problem. This work seeks to compare temporal extraction methods for extracting the fetal signal and estimating fetal heart rate. A novel method for MECG cancelation using an echo state neural network (ESN) based filtering approach was compared with the least mean square (LMS), the recursive least square (RLS) adaptive filter and template subtraction (TS) techniques. Analysis was performed using real signals from two databases composing a total of 4 h 22 min of data from nine pregnant women with 37,452 reference fetal beats. The effects of preprocessing the signals was empirically evaluated. The results demonstrate that the ESN based algorithm performs best on the test data with an F1 measure of 90.2% as compared to the LMS (87.9%), RLS (88.2%) and the TS (89.3%) techniques. Results suggest that a higher baseline wander high pass cut-off frequency than traditionally used for FECG analysis significantly increases performance for all evaluated methods. Open source code for the benchmark methods are made available to allow comparison and reproducibility on the public domain data.
Clifford Wavelet Entropy for Fetal ECG Extraction
Analysis of the fetal heart rate during pregnancy is essential for monitoring the proper development of the fetus. Current fetal heart monitoring techniques lack the accuracy in fetal heart rate monitoring and features acquisition, resulting in diagnostic medical issues. The challenge lies in the extraction of the fetal ECG from the mother ECG during pregnancy. This approach has the advantage of being a reliable and non-invasive technique. In the present paper, a wavelet/multiwavelet method is proposed to perfectly extract the fetal ECG parameters from the abdominal mother ECG. In a first step, due to the wavelet/mutiwavelet processing, a denoising procedure is applied to separate the noised parts from the denoised ones. The denoised signal is assumed to be a mixture of both the MECG and the FECG. One of the well-known measures of accuracy in information processing is the concept of entropy. In the present work, a wavelet/multiwavelet Shannon-type entropy is constructed and applied to evaluate the order/disorder of the extracted FECG signal. The experimental results apply to a recent class of Clifford wavelets constructed in Arfaoui, et al. J. Math. Imaging Vis. 2020, 62, 73–97, and Arfaoui, et al. Acta Appl. Math. 2020, 170, 1–35. Additionally, classical Haar–Faber–Schauder wavelets are applied for the purpose of comparison. Two main well-known databases have been applied, the DAISY database and the CinC Challenge 2013 database. The achieved accuracy over the test databases resulted in Se = 100%, PPV = 100% for FECG extraction and peak detection.
Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG
Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR.