Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
527
result(s) for
"instrumentation: high angular resolution"
Sort by:
Investigations of an Accelerometer-based Disturbance Feedforward Control for Vibration Suppression in Adaptive Optics of Large Telescopes
by
Glück, Martin
,
Sawodny, Oliver
,
Pott, Jörg-Uwe
in
instrumentation: adaptive optics
,
instrumentation: high angular resolution
,
Optics
2017
Adaptive Optics (AO) systems in large telescopes do not only correct atmospheric phase disturbances, but they also telescope structure vibrations induced by wind or telescope motions. Often the additional wavefront error due to mirror vibrations can dominate the disturbance power and contribute significantly to the total tip-tilt Zernike mode error budget. Presently, these vibrations are compensated for by common feedback control laws. However, when observing faint natural guide stars (NGS) at reduced control bandwidth, high-frequency vibrations (>5 Hz) cannot be fully compensated for by feedback control. In this paper, we present an additional accelerometer-based disturbance feedforward control (DFF), which is independent of the NGS wavefront sensor exposure time to enlarge the \"effective servo bandwidth\". The DFF is studied in a realistic AO end-to-end simulation and compared with commonly used suppression concepts. For the observation in the faint (>13 mag) NGS regime, we obtain a Strehl ratio by a factor of two to four larger in comparison with a classical feedback control. The simulation realism is verified with real measurement data from the Large Binocular Telescope (LBT); the application for on-sky testing at the LBT and an implementation at the E-ELT in the MICADO instrument is discussed.
Journal Article
Ten Years of Speckle Interferometry at SOAR
by
Tokovinin, Andrei
in
(stars:) binaries: visual
,
instrumentation: high angular resolution
,
techniques: high angular resolution
2018
Since 2007, close binary and multiple stars are observed by speckle interferometry at the 4.1 m Southern Astrophysical Research (SOAR) telescope. The HRCam instrument, observing strategy and planning, data processing and calibration methods, developed and improved during ten years, are presented here in a concise way. Thousands of binary stars were measured with diffraction-limited resolution (29 mas at 540 nm wavelength) and a high accuracy reaching 1 mas; 200 new pairs or subsystems were discovered. To date, HRCam has performed over 11,000 observations with a high efficiency (up to 300 stars per night). An overview of the main results delivered by this instrument is given.
Journal Article
The NN-explore Exoplanet Stellar Speckle Imager: Instrument Description and Preliminary Results
by
Everett, Mark E.
,
Scott, Nicholas J.
,
Howell, Steve B.
in
binaries (including multiple): close
,
Diffraction
,
Extrasolar planets
2018
A new speckle and wide-field imaging instrument for the WIYN telescope called NN-EXPLORE Exoplanet Stellar Speckle Imager (NESSI) is described. NESSI offers simultaneous two-color diffraction-limited imaging and wide-field traditional imaging for validation and characterization of transit and precision RV exoplanet studies. Many exoplanet targets will come from the NASA K2 and Transiting Exoplanet Survey Satellite (TESS) missions. NESSI is capable of resolving close binaries at sub-arcsecond separations down to the diffraction limit and >6 mag contrast difference in the visible band on targets as faint as 14th mag. Preliminary results from the instrument commissioning at WIYN and demonstrations of the instrument's capabilities are presented.
Journal Article
The ALMA Phasing System: A Beamforming Capability for Ultra-high-resolution Science at (Sub)Millimeter Wavelengths
by
Barkats, D. A.
,
Anderson, J. M.
,
Rottmann, H.
in
Astrophysics
,
Galactic Astrophysics
,
Instrumentation: high angular resolution
2018
The Atacama Millimeter/submillimeter Array (ALMA) Phasing Project (APP) has developed and deployed the hardware and software necessary to coherently sum the signals of individual ALMA antennas and record the aggregate sum in Very Long Baseline Interferometry (VLBI) Data Exchange Format. These beamforming capabilities allow the ALMA array to collectively function as the equivalent of a single large aperture and participate in global VLBI arrays. The inclusion of phased ALMA in current VLBI networks operating at (sub)millimeter wavelengths provides an order of magnitude improvement in sensitivity, as well as enhancements in u-v coverage and north-south angular resolution. The availability of a phased ALMA enables a wide range of new ultra-high angular resolution science applications, including the resolution of supermassive black holes on event horizon scales and studies of the launch and collimation of astrophysical jets. It also provides a high-sensitivity aperture that may be used for investigations such as pulsar searches at high frequencies. This paper provides an overview of the ALMA Phasing System design, implementation, and performance characteristics.
Journal Article
Minimizing the Polarization Leakage of Geometric-phase Coronagraphs with Multiple Grating Pattern Combinations
2020
The design of liquid-crystal diffractive phase plate coronagraphs for ground-based and space-based high-contrast imaging systems is limited by the trade-off between spectral bandwidth and polarization leakage. We demonstrate that by combining phase patterns with a polarization grating (PG) pattern directly followed by one or several separate PGs, we can suppress the polarization leakage terms by additional orders of magnitude by diffracting them out of the beam. Using two PGs composed of a single-layer liquid crystal structure in the lab, we demonstrate a leakage suppression of more than an order of magnitude over a bandwidth of 133 nm centered around 532 nm. At this center wavelength we measure a leakage suppression of three orders of magnitude. Furthermore, simulations indicate that a combination of two multi-layered liquid-crystal PGs can suppress leakage to <10−5 for 1–2.5 μm and <10−10 for 650–800 nm. We introduce multi-grating solutions with three or more gratings that can be designed to have no separation of the two circular polarization states, and offer even deeper suppression of polarization leakage. We present simulations of a triple-grating solution that has <10−10 leakage on the first Airy ring from 450 to 800 nm. We apply the double-grating concept to the Vector-vortex coronagraph of charge 4, and demonstrate in the lab that polarization leakage no longer limits the on-axis suppression for ground-based contrast levels. Lastly, we report on the successful installation and first-light results of a double-grating vector Apodizing Phase Plate pupil-plane coronagraph installed at the Large Binocular Telescope. We discuss the implications of these new coronagraph architectures for high-contrast imaging systems on the ground and in space.
Journal Article
Enhancing Stellar Spectroscopy with Extreme Adaptive Optics and Photonics
by
Jovanovic, N.
,
Schwab, C.
,
Martinache, F.
in
Astrophysics
,
Instrumentation and Methods for Astrophysic
,
instrumentation: adaptive optics
2016
Extreme adaptive optics (AO) systems are now in operation across the globe. These systems, capable of high order wavefront correction, deliver Strehl ratios of ∼ 90 % in the near-infrared. Originally intended for the direct imaging of exoplanets, these systems are often equipped with advanced coronagraphs that suppress the on-axis-star, interferometers to calibrate wavefront errors, and low order wavefront sensors to stabilize any tip/tilt residuals to a degree never seen before. Such systems are well positioned to facilitate the detailed spectroscopic characterization of faint substellar companions at small angular separations from the host star. Additionally, the increased light concentration of the point-spread function and the unprecedented stability create opportunities in other fields of astronomy as well, including spectroscopy. With such Strehl ratios, efficient injection into single-mode fibers (SMFs) or photonic lanterns becomes possible. With diffraction-limited components feeding the instrument, calibrating a spectrograph's line profile becomes considerably easier, as modal noise or imperfect scrambling of the fiber output are no longer an issue. It also opens up the possibility of exploiting photonic technologies for their advanced functionalities, inherent replicability, and small, lightweight footprint to design and build future instrumentation. In this work, we outline how extreme AO systems will enable advanced photonic and diffraction-limited technologies to be exploited in spectrograph design and the impact it will have on spectroscopy. We illustrate that the precision of an instrument based on these technologies, with light injected from an efficient SMF feed would be entirely limited by the spectral content and stellar noise alone on cool stars and would be capable of achieving a radial velocity precision of several m/s; the level required for detecting an exo-Earth in the habitable zone of a nearby M-dwarf.
Journal Article
The Impact of Interpixel Capacitance in CMOS Detectors on PSF Shapes and Implications for WFIRST
by
Kannawadi, Arun
,
Rhodes, Jason D.
,
Shapiro, Charles A.
in
instrumentation: detectors
,
instrumentation: high angular resolution
2016
Unlike optical CCDs, near-infrared detectors, which are based on CMOS hybrid readout technology, typically suffer from electrical crosstalk between the pixels. The interpixel capacitance (IPC) responsible for the crosstalk affects the point-spread function (PSF) of the telescope, increasing the size and modifying the shape of all objects in the images while correlating the Poisson noise. Upcoming weak lensing surveys that use these detectors, such as WFIRST, place stringent requirements on the PSF size and shape (and the level at which these are known), which in turn must be translated into requirements on IPC. To facilitate this process, we present a first study of the effect of IPC on WFIRST PSF sizes and shapes. Realistic PSFs are forward-simulated from physical principles for each WFIRST bandpass. We explore how the PSF size and shape depends on the range of IPC coupling with pixels that are connected along an edge or corner; for the expected level of IPC in WFIRST, IPC increases the PSF sizes by ∼5%. We present a linear fitting formula that describes the uncertainty in the PSF size or shape due to uncertainty in the IPC, which could arise for example due to unknown time evolution of IPC as the detectors age or due to spatial variation of IPC across the detector. We also study of the effect of a small anisotropy in the IPC, which further modifies the PSF shapes. Our results are a first, critical step in determining the hardware and characterization requirements for the detectors used in the WFIRST survey.
Journal Article
Development of Linear Astigmatism Free-Three Mirror System (LAF-TMS)
by
Ahn, Hojae
,
Pak, Soojong
,
Lee, Sunwoo
in
Aluminum
,
Astigmatism
,
instrumentation: high angular resolution
2020
We present the development of Linear Astigmatism Free-Three Mirror System (LAF-TMS). This is a prototype of an off-axis telescope that enables very wide field of view (FoV) infrared satellites that can observe Paschen- emission, zodiacal light, integrated starlight, and other infrared sources. It has the entrance pupil diameter of 150 mm, the focal length of 500 mm, and the FoV of 5 5 × 4 1. LAF-TMS is an obscuration-free off-axis system with minimal out-of-field baffling and no optical support structure diffraction. This optical design is analytically optimized to remove linear astigmatism and to reduce high-order aberrations. Sensitivity analysis and Monte-Carlo simulation reveal that tilt errors are the most sensitive alignment parameters that allow ∼1′. Optomechanical structure accurately mounts aluminum mirrors, and withstands satellite-level vibration environments. LAF-TMS shows optical performance with 37 m FWHM of the point source image satisfying Nyquist sampling requirements for typical 18 m pixel Infrared array detectors. The surface figure errors of mirrors and scattered light from the tertiary mirror with 4.9 nm surface microroughness may affect the measured point-spread function. Optical tests successfully demonstrate constant optical performance over wide FoV, indicating that LAF-TMS suppresses linear astigmatism and high-order aberrations.
Journal Article
Vision: A Six-telescope Fiber-fed Visible Light Beam Combiner for the Navy Precision Optical Interferometer
by
Stassun, Keivan G.
,
Benson, James A.
,
Garcia, Eugenio V.
in
Astronomical Instrumentation, Telescopes, Observatories, and Site Characterization
,
instrumentation: high angular resolution
,
instrumentation: interferometers
2016
Visible-light long baseline interferometry holds the promise of advancing a number of important applications in fundamental astronomy, including the direct measurement of the angular diameters and oblateness of stars, and the direct measurement of the orbits of binary and multiple star systems. To advance, the field of visible-light interferometry requires development of instruments capable of combining light from 15 baselines (6 telescopes) simultaneously. The Visible Imaging System for Interferometric Observations at NPOI (VISION) is a new visible light beam combiner for the Navy Precision Optical Interferometer (NPOI) that uses single-mode fibers to coherently combine light from up to six telescopes simultaneously with an image-plane combination scheme. It features a photometric camera for calibrations and spatial filtering from single-mode fibers with two Andor Ixon electron multiplying CCDs. This paper presents the VISION system, results of laboratory tests, and results of commissioning on-sky observations. A new set of corrections have been determined for the power spectrum and bispectrum by taking into account non-Gaussian statistics and read noise present in electron-multipying CCDs to enable measurement of visibilities and closure phases in the VISION post-processing pipeline. The post-processing pipeline has been verified via new on-sky observations of the O-type supergiant binary ζ Orionis A, obtaining a flux ratio of 2.18 0.13 with a position angle of 223 9 1 0 and separation 40.6 1.8 mas over 570-750 nm, in good agreement with expectations from the previously published orbit.
Journal Article
Measurements of Speckle Lifetimes in Near-infrared Extreme Adaptive Optics Images for Optimizing Focal Plane Wavefront Control
by
Hall, Donald N. B.
,
Martinache, Frantz
,
Lozi, Julien
in
Astronomical Software, Data Analysis, and Techniques
,
Astrophysics
,
Atmospheric effects
2018
Although extreme adaptive optics (ExAO) systems can greatly reduce the effects of atmospheric turbulence and deliver diffraction-limited images, our ability to observe faint objects such as extrasolar planets or debris disks at small angular separations is greatly limited by the presence of a speckle halo caused by imperfect wavefront corrections. These speckles change with a variety of timescales, from milliseconds to many hours, and various techniques have been developed to mitigate them during observations and during data reduction. Detection limits improve with increased speckle reduction, so an understanding of how speckles evolve (particularly at near-infrared wavelengths, which is where most adaptive optics science instruments operate) is of distinct interest. We used a SAPHIRA detector behind Subaru Telescope's SCExAO instrument to collect H-band images of the ExAO-corrected point-spread function (PSF) at a frame rate of 1.68 kHz. We analyzed these images using two techniques to measure the timescales over which the speckles evolved. In the first technique, we analyzed the images in a manner applicable to predicting performance of real-time speckle-nulling loops. We repeated this analysis using data from several nights to account for varying weather and AO conditions. In our second analysis, which follows the techniques employed by Milli et al. (2016) but using data with three orders of magnitude better temporal resolution, we identified a new regime of speckle behavior that occurs at timescales of milliseconds. It is not purely an instrument effect and likely is an atmospheric timescale filtered by the ExAO response. We also observed an exponential decay in the Pearson's correlation coefficients (which we employed to quantify the change in speckles) on timescales of seconds and a linear decay on timescales of minutes, which is in agreement with the behavior observed by Milli et al. For both of our analyses, we also collected similar data sets using SCExAO's internal light source to separate atmospheric effects from instrumental effects.
Journal Article