Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
1,104 result(s) for "light scattering distribution"
Sort by:
Preliminary Study for Smoke Color Classification of Combustibles Using the Distribution of Light Scattering by Smoke Particles
Photoelectric smoke detectors are used for early detection of building fires, and sensitivity adjustment is generally performed using white smoke generated by the burning of filter paper. Therefore, when black smoke of the same concentration is introduced, the detector is often not activated. To address this problem, differences in the distribution of light scattered by smoke of various colors were analyzed. A light-scattering chamber with a light-receiving unit for various scattering angles was constructed to measure the scattered light generated inside the chamber of the smoke detector. The light scattering distribution was measured for smoke generated from three combustibles—filter paper (white smoke), kerosene (black smoke), and polyurethane (gray-black smoke)—and three analysis criteria were applied. By identifying a section where the measured values were concentrated for a specific analysis criterion and scattering angle, it was confirmed that some combustibles can be distinguished. Specifically, criterion III, a probabilistic section, was presented to determine which combustible smoke particles were close by applying the proposed section in a complex manner. A preliminary study was conducted to evaluate a methodology for the color classification of smoke particles flowing into a smoke detector chamber; this can be utilized as a foundation for determining optical properties.
Evaluating the PurpleAir monitor as an aerosol light scattering instrument
The Plantower PMS5003 sensors (PMS) used in the PurpleAir monitor PA-II-SD configuration (PA-PMS) are equivalent to cell-reciprocal nephelometers using a 657 nm perpendicularly polarized light source that integrates light scattering from 18 to 166∘. Yearlong field data at the National Oceanic and Atmospheric Administration's (NOAA) Mauna Loa Observatory (MLO) and Boulder Table Mountain (BOS) sites show that the 1 h average of the PA-PMS first size channel, labeled “> 0.3 µm” (“CH1”), is highly correlated with submicrometer aerosol scattering coefficients at the 550 and 700 nm wavelengths measured by the TSI 3563 integrating nephelometer, from 0.4 to 500 Mm−1. This corresponds to an hourly average submicrometer aerosol mass concentration of approximately 0.2 to 200 µg m−3. A physical–optical model of the PMS is developed to estimate light intensity on the photodiode, accounting for angular truncation of the volume scattering function as a function of particle size. The model predicts that the PMS response to particles > 0.3 µm decreases relative to an ideal nephelometer by about 75 % for particle diameters ≥ 1.0 µm. This is a result of using a laser that is polarized, the angular truncation of the scattered light, and particle losses (e.g., due to aspiration) before reaching the laser. It is shown that CH1 is linearly proportional to the model-predicted intensity of the light scattered by particles in the PMS laser to its photodiode over 4 orders of magnitude. This is consistent with CH1 being a measure of the scattering coefficient and not the particle number concentration or particulate matter concentration. The model predictions are consistent with data from published laboratory studies which evaluated the PMS against a variety of aerosols. Predictions are then compared with yearlong fine aerosol size distribution and scattering coefficient field data at the BOS site. Field data at BOS confirm the model prediction that the ratio of CH1 to the scattering coefficient would be highest for aerosols with median scattering diameters < 0.3 µm. The PMS detects aerosols smaller than 0.3 µm diameter in proportion to their contribution to the scattering coefficient. The results of this study indicate that the PMS is not an optical particle counter and that its six size fractions are not a meaningful representation of particle size distribution. The relationship between the PMS 1 h average CH1 and bsp1, the scattering coefficient in Mm−1 due to particles below 1 µm aerodynamic diameter, at wavelength 550 nm, is found to be bsp1 = 0.015 ± 2.07 × 10−5 × CH1, for relative humidity below 40 %. The coefficient of determination r2 is 0.97. This suggests that the low-cost and widely used PA monitors can be used to measure and predict the submicron aerosol light scattering coefficient in the mid-visible nearly as well as integrating nephelometers. The effectiveness of the PA-PMS to serve as a PM2.5 mass concentration monitor is due to both the sensor behaving like an imperfect integrating nephelometer and the mass scattering efficiency of ambient PM2.5 aerosols being roughly constant.
Measurement of absorption and reduced scattering coefficients in Asian human epidermis, dermis, and subcutaneous fat tissues in the 400- to 1100-nm wavelength range for optical penetration depth and energy deposition analysis
Significance: In laser therapy and diagnosis of skin diseases, the irradiated light distribution, which is determined by the absorption coefficient μa and reduced scattering coefficient μs′ of the epidermis, dermis, and subcutaneous fat, affects the treatment outcome and diagnosis accuracy. Although values for μa and μs′ have been reported, detailed analysis for Asian skin tissues is still lacking. Aim: We present μa and μs′ measurements of Asian skin tissues in the 400- to 1100-nm wavelength range for evaluating optical penetration depth and energy deposition. Approach: The measurements with Asian human skin samples are performed employing a double integrating sphere spectrometric system and an inverse Monte Carlo technique. Using the measured parameters, the optical penetration depth and energy deposition are quantitatively analyzed. Results: The μa of the epidermis layer varies among different ethnic groups, while the μa of the other layers and the μs′ of all of the layers exhibit almost no differences. The analysis reveals that the optical penetration depth and the energy deposition affect the photodynamic therapy treatment depth and the heat production in skin tissue, respectively. Conclusions: The experimentally measured values of μa and μs′ for Asian skin tissues are presented, and the light behavior in Asian skin tissues is analyzed using a layered tissue model.
Dynamic light scattering distributions by any means
Dynamic light scattering (DLS) is an essential technique for nanoparticle size analysis and has been employed extensively for decades, but despite its long history and popularity, the choice of weighting and mean of the size distribution often appears to be picked ad hoc to bring the results into agreement with other methods and expectations by any means necessary. Here, we critically discuss the application of DLS for nanoparticle characterization and provide much-needed clarification for ambiguities in the mean-value practice of commercial DLS software and documentary standards. We address the misleading way DLS size distributions are often presented, that is, as a logarithmically scaled histogram of measured relative quantities. Central values obtained incautiously from this representation often lead to significant interpretation errors. Through the measurement of monomodal nanoparticle samples having an extensive range of sizes (5 to 250 nm) and polydispersity, we similarly demonstrate that the default outputs of a frequently used DLS inversion method are ill chosen, as they are regularizer-dependent and significantly deviate from the cumulant z-average size. The resulting discrepancies are typically larger than 15% depending on the polydispersity index of the samples. We explicitly identify and validate the harmonic mean as the central value of the intensity-weighted DLS size distribution that expresses the inversion results consistently with the cumulant results. We also investigate the extent to which the DLS polydispersity descriptors are representative of the distributional quality and find them to be unreliable and misleading, both for monodisperse reference materials and broad-distribution biomedical nanoparticles. These results overall are intended to bring essential improvements and to stimulate reexamination of the metrological capabilities and role of DLS in nanoparticle characterization.
Measurement of light-by-light scattering and search for axion-like particles with 2.2 nb−1 of Pb+Pb data with the ATLAS detector
A bstract This paper describes a measurement of light-by-light scattering based on Pb+Pb collision data recorded by the ATLAS experiment during Run 2 of the LHC. The study uses 2 . 2 nb − 1 of integrated luminosity collected in 2015 and 2018 at s NN = 5 . 02 TeV. Light-by-light scattering candidates are selected in events with two photons produced exclusively, each with transverse energy E T γ > 2 . 5 GeV, pseudorapidity |η γ | < 2 . 37, diphoton invariant mass m γγ > 5 GeV, and with small diphoton transverse momentum and diphoton acoplanarity. The integrated and differential fiducial cross sections are measured and compared with theoretical predictions. The diphoton invariant mass distribution is used to set limits on the production of axion-like particles. This result provides the most stringent limits to date on axion-like particle production for masses in the range 6–100 GeV. Cross sections above 2 to 70 nb are excluded at the 95% CL in that mass interval.
Observations of relative humidity effects on aerosol light scattering in the Yangtze River Delta of China
Scattering of solar radiation by aerosol particles is highly dependent on relative humidity (RH) as hygroscopic particles take up water with increasing RH. To achieve a better understanding of the effect of aerosol hygroscopic growth on light scattering properties and radiative forcing, the aerosol scattering coefficients at RH in the range of 40 to ~ 90 % were measured using a humidified nephelometer system in the Yangtze River Delta of China in March 2013. In addition, the aerosol size distribution and chemical composition were measured. During the observation period, the mean and standard deviation (SD) of enhancement factors at RH = 85 % for the scattering coefficient (f(85 %)), backscattering coefficient (fb(85 %)), and hemispheric backscatter fraction (fβ(85 %)) were 1.58 ± 0.12, 1.25 ± 0.07, and 0.79 ± 0.04, respectively, i.e., aerosol scattering coefficient and backscattering coefficient increased by 58 and 25 % as the RH increased from 40 to 85 %. Concurrently, the aerosol hemispheric backscatter fraction decreased by 21 %. The relative amount of organic matter (OM) or inorganics in PM1 was found to be a main factor determining the magnitude of f(RH). The highest values of f(RH) corresponded to the aerosols with a small fraction of OM, and vice versa. The relative amount of NO3− in fine particles was strongly correlated with f(85 %), which suggests that NO3− played a vital role in aerosol hygroscopic growth during this study. The mass fraction of nitrate also had a close relationship to the curvature of the humidograms; higher mass fractions of nitrate were associated with humidograms that had the least curvature. Aerosol hygroscopic growth caused a 47 % increase in the calculated aerosol direct radiative forcing at 85 % RH, compared to the forcing at 40 % RH.
Dynamic Light Scattering: A Powerful Tool for In Situ Nanoparticle Sizing
Due to surface effects and quantum size effects, nanomaterials have properties that are vastly different from those of bulk materials due to surface effects. The particle size distribution plays an important role in chemical and physical properties. The measurement and control of this parameter are crucial for nanomaterial synthesis. Dynamic light scattering (DLS) is a fast and non-invasive tool used to measure particle size, size distribution and stability in solutions or suspensions during nanomaterial preparation. In this review, we focus on the in situ sizing of nanomaterial preparation in the form of colloids, especially for metal oxide nanoparticles (MONs). The measuring principle, including an overview of sizing techniques, advantages and limitations and theories of DLS were first discussed. The instrument design was then investigated. Ex-situ and in situ configuration of DLS, sample preparations, measurement conditions and reaction cell design for in situ configuration were studied. The MONs preparation monitored by DLS was presented, taking into consideration both ex situ and in situ configuration.
Angularly resolved, finely sampled elastic scattering measurements of single cells: requirements for robust organelle size extractions
Angularly resolved elastic light scattering is an established technique for probing the average size of organelles in biological tissue and cellular ensembles. Focusing of the incident light to illuminate no more than one cell at a time restricts the minimum forward-scattering angle θmin that can be detected. Series of simulated single-cell angular-scattering patterns have been generated to explore how size estimates vary as a function of θmin. At a setting of θmin  =  20  deg, the size estimates hop unstably between multiple minima in the solution space as simulated noise (mimicking experimentally observed levels) is varied. As θmin is reduced from 20 deg to 10 deg, the instability vanishes, and the variance of estimates near the correct answer also decreases. The simulations thus suggest that robust Mie theory fits to single-cell scattering at 785 nm excitation require measurements down to at least 15 deg. Notably, no such instability was observed at θmin  =  20  deg for narrow bead distributions. Accurate sizing of traditional calibration beads is, therefore, insufficient proof that an angular-scattering system is capable of robust analysis of single cells. Experimental support for the simulation results is also presented using measurements on cells fixed with formaldehyde.
Physical and optical properties of aged biomass burning aerosol from wildfires in Siberia and the Western USA at the Mt. Bachelor Observatory
The summer of 2015 was an extreme forest fire year in the Pacific Northwest. Our sample site at the Mt. Bachelor Observatory (MBO, 2.7 km a.s.l.) in central Oregon observed biomass burning (BB) events more than 50 % of the time during August. In this paper we characterize the aerosol physical and optical properties of 19 aged BB events during August 2015. Six of the 19 events were influenced by Siberian fires originating near Lake Baikal that were transported to MBO over 4–10 days. The remainder of the events resulted from wildfires in Northern California and Southwestern Oregon with transport times to MBO ranging from 3 to 35 h. Fine particulate matter (PM1), carbon monoxide (CO), aerosol light scattering coefficients (σscat), aerosol light absorption coefficients (σabs), and aerosol number size distributions were measured throughout the campaign. We found that the Siberian events had a significantly higher Δσabs∕ΔCO enhancement ratio, higher mass absorption efficiency (MAE; Δσabs∕ΔPM1), lower single scattering albedo (ω), and lower absorption Ångström exponent (AAE) when compared with the regional events. We suggest that the observed Siberian events represent that portion of the plume that has hotter flaming fire conditions and thus enabled strong pyroconvective lofting and long-range transport to MBO. The Siberian events observed at MBO therefore represent a selected portion of the original plume that would then have preferentially higher black carbon emissions and thus an enhancement in absorption. The lower AAE values in the Siberian events compared to regional events indicate a lack of brown carbon (BrC) production by the Siberian fires or a loss of BrC during transport. We found that mass scattering efficiencies (MSE) for the BB events ranged from 2.50 to 4.76 m2 g−1. We measured aerosol size distributions with a scanning mobility particle sizer (SMPS). Number size distributions ranged from unimodal to bimodal and had geometric mean diameters (Dpm) ranging from 138 to 229 nm and geometric standard deviations (σg) ranging from 1.53 to 1.89. We found MSEs for BB events to be positively correlated with the geometric mean of the aerosol size distributions (R2 = 0.73), which agrees with Mie theory. We did not find any dependence on event size distribution to transport time or fire source location.
Three-dimensional angular scattering simulations inform analysis of scattering from single cells
Organelle sizes, which are indicative of cellular status, have implications for drug development and immunology research. At the single cell level, such information could be used to study the heterogeneity of cell response to drugs or pathogens. Angularly resolved elastic light scattering is known to be sensitive to changes in organelle size distribution. We developed a Mie theory-based simulation of angular scattering from single cells to quantify the effects of noise on scattering and size estimates. We simulated randomly sampled organelle sizes (drawn from a log normal distribution), interference between different organelles' scattering, and detector noise. We quantified each noise source's effect upon the estimated mean and standard deviation of organelle size distributions. The results demonstrate that signal-to-noise ratio in the angular scattering increased with the number of scatterers, cell area, and exposure time and decreased with the size distribution width. The error in estimating the mean of the size distributions remained below 5% for nearly all experimental parameters tested, but the widest size distribution tested (standard deviation of 600 nm) reached 20%. The simulator revealed that sparse sampling of a broad size distribution can dominate the mismatch between actual and predicted size parameters. Alternative estimation strategies could reduce the discrepancy.