Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
100 result(s) for "microgrid (MG)"
Sort by:
An Online Archimedes Optimization Algorithm Identifier-Controlled Adaptive Modified Virtual Inertia Control for Microgrids
Single widespread employment of renewable energy sources (RESs) contributes to the shortage in the inertia of the microgrid (MG). After this, frequency stability may regress as a result of power imbalance or minor load fluctuations. This paper proposes an explicit adaptive modified virtual inertia control (VIC) based on an online Archimedes optimization algorithm (AOA) identifier for MG containing thermal, wind, and solar photovoltaic power plants. The Rung Kutta approach is used to construct the proposed online identifier, which acts as a model of the MG. AOA predicts the coefficients of the online identifier based on the input and output of MG to mimic the frequency deviation of the MG online. AOA estimates online the inertia and damping coefficients of the VIC system with an energy storage device based on online AOA identifier coefficients. The frequency deviation of the MG based on the proposed explicit adaptive modified VIC is compared with the conventional VIC based on fixed parameters and the VIC system based on optimal parameters using AOA offline under mutation in loads, weather-dependent input, and MG parameters using MATLAB/Simulink software. Furthermore, the proposed explicit adaptive modified VIC based on an online AOA identifier is evaluated with the adaptive VIC system based on fuzzy logic control, which adjusts only the inertial gain online. The simulation results demonstrate the capabilities of the proposed explicit adaptive modified VIC to improve the frequency stability and enhance low-inertia islanded MGs with RESs.
Distributed Renewable Generation and Storage System Sizing Based on Smart Dispatch of Microgrids
This paper considers the contribution of independent owners (IOs) operating within microgrids (MGs) toward green power generation in deregulated energy markets. An optimization scheme is introduced for sizing distributed renewable generation (DRG) and a distributed energy storage system (DESS) based on a novel energy management system (EMS) that accounts for demand response (DR), DESS dispatch and performance degradation, dynamic pricing environments, power distribution loss and irregular renewable generation. The proposed EMS utilizes an iterative Newton-Raphson linear programming algorithm that schedules resources in order to minimize the objective function, to deal with the complicated nonlinear nature of the problem and to enable efficient long-term assessments. The EMS is used to evaluate candidate solutions that are generated by a genetic algorithm (GA) to determine the optimal combination of DRG and DESS. A case study for IEEE 34-bus distribution MG in Okinawa, Japan, is used for testing the algorithm and analyzing the potential for IO/MG investments and their strategies.
A case study of optimal design and techno-economic analysis of an islanded AC microgrid
Microgrids (MGs) are essential in the distribution system by utilizing widely dispersed generation sources. Due to their economical and environmentally friendly attributes, Islanded AC MGs are commonly used to supply electricity to isolated locations independent of the primary grid. This study focuses on optimizing the configuration of an islanded AC MG to meet the electrical requirements of an international school in the New Administrative Capital, New Cairo, Egypt. Hybrid Optimization of Multiple Energy Resources (HOMER) software is employed to obtain the optimal size of the sources in the MG by minimizing the Levelized Cost of Energy (LCOE) and Total Net Present Cost (TNPC). According to the HOMER simulation results, a 200 kW PV system, a 180-kW wind turbine, a 50 kW FC, a 50 kW electrolyzer, a 50 kg hydrogen tank, a 180 kW DG, and a 686-kWh lead-acid battery form the optimal configuration of the islanded AC MG. The results reveal the contribution of each energy component to meeting the electricity demand, yielding an LCOE of $0.153/kWh and a TNPC of $1,775,300.00. The dynamic performance of the islanded microgrid is examined, introducing a Model Reference Adaptive Control based PI controller (MRAC-PI) to enhance transient response across all operational conditions. A comparative analysis is performed against traditional PI-PSO and PI-WOA controllers under load variations and changing weather conditions. The results indicate that the proposed control strategy effectively maintains system frequency and voltage amid various disturbances, improves dynamic performance, and achieves a balanced power generation and load demand. Additionally, the proposed controller demonstrates superior dynamic response, featuring reduced overshoot, undershoot, ITAE, and settling time compared to the others.
Performance Enhancement of an Islanded Microgrid with the Support of Electrical Vehicle and STATCOM Systems
Modern electrical power systems now require the spread of microgrids (MG), where they would be operating in either islanded mode or grid-connected mode. An inherent mismatch between loads and sources is introduced by changeable high renewable share in an islanded MG system with stochastic load demands. The system frequency is directly impacted by this mismatch, which can be alleviated by incorporating cutting-edge energy storage technologies and FACTS tools. The investigated islanded MG system components are wind farm, solar PV, Electric vehicles (EVs), loads, DSTATCOM, and diesel power generator. An aggregated EVs model is connected to the MG during uncertain periods of the generation of renewable energy (PV and wind) to support the performance of MGs. The ability to support ancillary services from the EVs is checked. DSTATCOM is used to provide voltage stability for the MG during congestion situations. The MG is studied in three scenarios: the first scenario MG without EVs and DSTATCOM, the second scenario MG without DSTATCOM, and the third scenario MG with all components. These scenarios are addressed to show the role of EVs and DSTATCOM, and the results in the third scenario are the best. The system voltage and frequency profile is the best in the last scenario and is entirely satisfactory and under the range of the IEEE standard. The obtained results show that both EVs and DSTATCOM are important units for improving the stability of modern power grids. The Matlab/Simulink program is considered for checking and validating the dynamic performance of the proposed configuration.
Enhanced Microgrid Control through Genetic Predictive Control: Integrating Genetic Algorithms with Model Predictive Control for Improved Non-Linearity and Non-Convexity Handling
Microgrid (MG) control is crucial for efficient, reliable, and sustainable energy management in distributed energy systems. Genetic Algorithm-based energy management systems (GA-EMS) can optimally control MGs by solving complex, non-linear, and non-convex problems but may struggle with real-time application due to their computational demands. Model Predictive Control (MPC)-based EMS, which predicts future behaviour to ensure optimal performance, usually depends on linear models. This paper introduces a novel Genetic Predictive Control (GPC) method that combines a GA and MPC to enhance resource allocation, balance multiple objectives, and adapt dynamically to changing conditions. Integrating GAs with MPC improves the handling of non-linearities and non-convexity, resulting in more accurate and effective control. Comparative analysis reveals that GPC significantly reduces excess power production, improves resource allocation, and balances cost, emissions, and power efficiency. For example, in the Mutation–Random Selection scenario, GPC reduced excess power to 76.0 W compared to 87.0 W with GA; in the Crossover-Elitism scenario, GPC achieved a lower daily cost of USD 113.94 versus the GA’s USD 127.80 and reduced carbon emissions to 52.83 kg CO2e compared to the GA’s 69.71 kg CO2e. While MPC optimises a weighted sum of objectives, setting appropriate weights can be difficult and may lead to non-convex problems. GAs offer multi-objective optimisation, providing Pareto-optimal solutions. GPC maintains optimal performance by forecasting future load demands and adjusting control actions dynamically. Although GPC can sometimes result in higher costs, such as USD 113.94 compared to USD 131.90 in the Crossover–Random Selection scenario, it achieves a better balance among various metrics, proving cost-effective in the long term. By reducing excess power and emissions, GPC promotes economic savings and sustainability. These findings highlight GPC’s potential as a versatile, efficient, and environmentally beneficial tool for power generation systems.
Optimal Allocation of Renewable Distributed Generators and Electric Vehicles in a Distribution System Using the Political Optimization Algorithm
This paper proposes an effective approach to solve renewable distributed generators (RDGs) and electric vehicle charging station (EVCS) allocation problems in the distribution system (DS) to reduce power loss (PLoss) and enhance voltage profile. The RDGs considered for this work are solar, wind and fuel cell. The uncertainties related to RDGs are modelled using probability distribution functions (PDF). These sources’ best locations and sizes are identified by the voltage stability index (VSI) and political optimization algorithm (POA). Furthermore, EV charging strategies such as the conventional charging method (CCM) and optimized charging method (OCM) are considered to study the method’s efficacy. The developed approach is studied on Indian 28 bus DS. Different cases are considered, such as a single DG, multiple DGs and a combination of DGs and EVs. This placement of multiple DGs along with EVs, considering proper scheduling patterns, minimizes PLoss and considerably improves the voltage profile. Finally, the proposed method is compared with other algorithms, and simulated results show that the POA method produces better results in all aspects.
Short-Term Load Forecasting of Microgrid via Hybrid Support Vector Regression and Long Short-Term Memory Algorithms
Short-Term Load Forecasting (STLF) is the most appropriate type of forecasting for both electricity consumers and generators. In this paper, STLF in a Microgrid (MG) is performed via the hybrid applications of machine learning. The proposed model is a modified Support Vector Regression (SVR) and Long Short-Term Memory (LSTM) called SVR-LSTM. In order to forecast the load, the proposed method is applied to the data related to a rural MG in Africa. Factors influencing the MG load, such as various household types and commercial entities, are selected as input variables and load profiles as target variables. Identifying the behavioral patterns of input variables as well as modeling their behavior in short-term periods of time are the major capabilities of the hybrid SVR-LSTM model. To present the efficiency of the suggested method, the conventional SVR and LSTM models are also applied to the used data. The results of the load forecasts by each network are evaluated using various statistical performance metrics. The obtained results show that the SVR-LSTM model with the highest correlation coefficient, i.e., 0.9901, is able to provide better results than SVR and LSTM, which have the values of 0.9770 and 0.9809, respectively. Finally, the results are compared with the results of other studies in this field, which continued to emphasize the superiority of the SVR-LSTM model.
Control and EMS of a Grid-Connected Microgrid with Economical Analysis
Recently, significant development has occurred in the field of microgrid and renewable energy systems (RESs). Integrating microgrids and renewable energy sources facilitates a sustainable energy future. This paper proposes a control algorithm and an optimal energy management system (EMS) for a grid-connected microgrid to minimize its operating cost. The microgrid includes photovoltaic (PV), wind turbine (WT), and energy storage systems (ESS). The interior search algorithm (ISA) optimization technique determines the optimal hour-by-hour scheduling for the microgrid system, while it meets the required load demand based on 24-h ahead forecast data. The control system consists of three stages: EMS, supervisory control and local control. EMS is responsible for providing the control system with the optimum day-ahead scheduling power flow between the microgrid (MG) sources, batteries, loads and the main grid based on an economic analysis. The supervisory control stage is responsible for compensating the mismatch between the scheduled power and the real microgrid power. In addition, this paper presents the local control design to regulate the local power, current and DC voltage of the microgrid. For verification, the proposed model was applied on a real case study in Oshawa (Ontario, Canada) with various load conditions.
Wind‐assisted microgrid grid code compliance employing a hybrid Particle swarm optimization‐Artificial hummingbird algorithm optimizer‐tuned STATCOM
The importance of resolving stability concerns in weak AC grid‐connected doubly fed induction generator (DFIG) wind energy systems during low‐voltage ride‐through (LVRT) events cannot be ignored, given the increasing popularity of wind power‐based microgrids. Furthermore, the emergence of generation loss and postfault oscillation within a microgrid (MG) due to grid faults has also become a significant concern. The static synchronous compensator (STATCOM) under consideration in this study is tuned using particle swarm optimization (PSO), the artificial hummingbird algorithm (AHA), and a hybrid approach incorporating both PSO and AHA. Faults of both a symmetrical and an asymmetrical nature have occurred on the power grid side. The proposed hybrid PSO‐AHA‐tuned STATCOM strategy aims to improve LVRT, minimize power generation loss during faults, and reduce oscillations after a fault by controlling the flow of reactive power between point of common coupling (PCC) and MG. The MATLAB simulation environment was used to simulate the 16 MW MG test system. The performance of the PSO‐AHA‐tuned STATCOM was assessed by comparing results with those from conventional STATCOM, PSO, and AHA optimizer‐tuned STATCOM in four fault situations. A comparison of the results shows that the proposed strategy performed better than other approaches mentioned in this paper and achieved the desired objectives.
A Nearly Zero-Energy Microgrid Testbed Laboratory: Centralized Control Strategy Based on SCADA System
Currently, despite the use of renewable energy sources (RESs), distribution networks are facing problems, such as complexity and low productivity. Emerging microgrids (MGs) with RESs based on supervisory control and data acquisition (SCADA) are an effective solution to control, manage, and finally deal with these challenges. The development and success of MGs is highly dependent on the use of power electronic interfaces. The use of these interfaces is directly related to the progress of SCADA systems and communication infrastructures. The use of SCADA systems for the control and operation of MGs and active distribution networks promotes productivity and efficiency. This paper presents a real MG case study called the LAMBDA MG testbed laboratory, which has been implemented in the electrical department of the Sapienza University of Rome with a centralized energy management system (CEMS). The real-time results of the SCADA system show that a CEMS can create proper energy balance in a LAMBDA MG testbed and, consequently, minimize the exchange power of the LAMBDA MG and main grid.