Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
6 result(s) for "optical fiber fluorescent pH sensor"
Sort by:
Dual-Lifetime Referencing (t-DLR) Optical Fiber Fluorescent pH Sensor for Microenvironments
The pH behavior in the μm to cm thick diffusion boundary layer (DBL) surrounding many aquatic species is dependent on light-controlled metabolic activities. This DBL microenvironment exhibits different pH behavior to bulk seawater, which can reduce the exposure of calcifying species to ocean acidification conditions. A low-cost time-domain dual-lifetime referencing (t-DLR) interrogation system and an optical fiber fluorescent pH sensor were developed for pH measurements in the DBL interface. The pH sensor utilized dual-layer sol-gel coatings of pH-sensitive iminocoumarin and pH-insensitive Ru(dpp)3-PAN. The sensor has a dynamic range of 7.41 (±0.20) to 9.42 ± 0.23 pH units (95% CI, T = 20 °C, S = 35), a response time (t90) of 29 to 100 s, and minimal salinity dependency. The pH sensor has a precision of approximately 0.02 pHT units, which meets the Global Ocean Acidification Observing Network (GOA-ON) “weather” measurement quality guideline. The suitability of the t-DLR optical fiber pH sensor was demonstrated through real-time measurements in the DBL of green seaweed Ulva sp. This research highlights the practicability of optical fiber pH sensors by demonstrating real-time pH measurements of metabolic-induced pH changes.
A Dual Sensor for pH and Hydrogen Peroxide Using Polymer-Coated Optical Fibre Tips
This paper demonstrates the first single optical fibre tip probe for concurrent detection of both hydrogen peroxide (H2O2) concentration and pH of a solution. The sensor is constructed by embedding two fluorophores: carboxyperoxyfluor-1 (CPF1) and seminaphtharhodafluor-2 (SNARF2) within a polymer matrix located on the tip of the optical fibre. The functionalised fibre probe reproducibly measures pH, and is able to accurately detect H2O2 over a biologically relevant concentration range. This sensor offers potential for non-invasive detection of pH and H2O2 in biological environments using a single optical fibre.
A Portable ‘Plug-and-Play’ Fibre Optic Sensor for In-Situ Measurements of pH Values for Microfluidic Applications
Microfluidics is used in many applications ranging from chemistry, medicine, biology and biomedical research, and the ability to measure pH values in-situ is an important parameter for creating and monitoring environments within a microfluidic chip for many such applications. We present a portable, optical fibre-based sensor for monitoring the pH based on the fluorescent intensity change of an acrylamidofluorescein dye, immobilized on the tip of a multimode optical fibre, and its performance is evaluated in-situ in a microfluidic channel. The sensor showed a sigmoid response over the pH range of 6.0–8.5, with a maximum sensitivity of 0.2/pH in the mid-range at pH 7.5. Following its evaluation, the sensor developed was used in a single microfluidic PDMS channel and its response was monitored for various flow rates within the channel. The results thus obtained showed that the sensor is sufficiently robust and well-suited to be used for measuring the pH value of the flowing liquid in the microchannel, allowing it to be used for a number of practical applications in ‘lab-on-a-chip’ applications where microfluidics are used. A key feature of the sensor is its simplicity and the ease of integrating the sensor with the microfluidic channel being probed.
Fluorescence sensor using a molecularly imprinted polymer as a recognition receptor for the detection of aluminium ions in aqueous media
This paper describes the investigation of a molecularly imprinted polymer (MIP) as a sensing receptor for Al³⁺ ion detection by using an optical approach. Al³⁺ ion was adopted as the template molecule and 8-hydroxyquinoline sulfonic acid ligand as the fluorescence tag. The polymer was synthesised using acrylamide as monomer, 2-hydroxyethyl methacrylate as co-monomer and ethylene glycol dimethracylate as cross-linker. The free radical polymerisation was performed in methanol and initiated by 2,2'-azobisisobutyronitrile at 70 °C. The imprinted polymer was fluorometrically characterised using a fibre optic attachment in a self-designed flow-cell. NaF was used to leach the Al³⁺ ion from the MIP. The optimum pH for the rebinding of Al³⁺ ion with the leached polymer was found to be pH 5 and the fluorescence response was found to be stable within the buffer strength range of 0.05-0.10 M. The fluorescence intensity during Al³⁺ ion rebinding was inversely dependent on temperature, and a low interference response (<3%) toward metal ions except for Cu²⁺ and Zn²⁺ ions was observed. The polymer rebinding repeatability study conducted over 9 cycles with Al³⁺ ion (0.8x10-⁴ M) was found to give an RSD value of 2.82% with a standard deviation of 0.53. The dynamic range of the system was found to be linear up to 1.0x10-⁴ M Al³⁺ ion with a limit of detection of 3.62 μM.
Fiber-optic pH detection in small volumes of biosamples
Determining the pH values of microscopic plant samples may help to explain complex processes in plants, so it is an area of interest to botanists. Fiber-optic probes with small dimensions can be used for this purpose. This paper deals with the fiber-optic detection of the pH values of droplets of plant xylem exudate based on ratiometric fluorescence intensity measurements with an internal reference. For this purpose, novel V-taper sensing probes with a minimum diameter of around 8 μm were prepared that enable the delivery of fluorescence signal from the detection site on the taper tip to the detector. The taper tips were coated with pH-sensitive transducer (8-hydroxypyrene-1,3,6-trisulfonic acid trisodium salt; HPTS) and a reference [dichlorotris-(1,10-phenanthroline) ruthenium (II) hydrate (Ru-phen dichloride)] immobilized in a xerogel layer of propyltriethoxysilane and (3-glycidoxy)propyl trimethoxysilane. The prepared probes were sensitive to pH values mainly in the range from 6.0 to 9.0. In the pH range 6-9, the results were limited by measurement errors of about 0.2 pH units, and in the pH range 5-6 by measurement errors of about 0.5 pH units. Using the developed V-taper sensing probes, the pH values of in vivo and in vitro samples of small volumes (∼6 μl) of exudate were measured. The results were validated by comparison with conventional electrochemical pH measurements.
Heterogeneous Wide Range pH-sensing Materials Allowing Ratiometric Fluorescence Detection Based on Structurally Rigid Analogs of 2,6-distyrylpyridine
The new sensing materials based on the microsized silica gel powder with non-covalently immobilized structurally rigid analogs of 2,6-distyrylpyrydine ((3E,5E)-3,5-dibenzylidene-8-phenyl-1,2,3,5,6,7-hexahydrodicyclopenta[b,e]pyridines) were developed and tested. Most of the investigated compositions demonstrate linear ratiometric fluorescence response on pH in the physiologically important interval (pH 6–9). The compound with the greatest number of protolytic centers within the studied series demonstrated the widest pH sensitivity range, however in this case the analytical signal was the lowest. The prospects for the practical application of the investigated materials in the fiber optics sensing devices were outlined.