Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
99
result(s) for
"physics.ins-det"
Sort by:
LiteBIRD: A Satellite for the Studies of B-Mode Polarization and Inflation from Cosmic Background Radiation Detection
by
Otani, C.
,
Matsuura, S.
,
Jeong, O.
in
Angular resolution
,
B-mode polarization
,
Background radiation
2019
LiteBIRD is a candidate satellite for a strategic large mission of JAXA. With its expected launch in the middle of the 2020s with a H3 rocket, LiteBIRD plans to map the polarization of the cosmic microwave background radiation over the full sky with unprecedented precision. The full success of LiteBIRD is to achieve
δ
r
<
0.001
, where
δ
r
is the total error on the tensor-to-scalar ratio
r
. The required angular coverage corresponds to
2
≤
ℓ
≤
200
, where
ℓ
is the multipole moment. This allows us to test well-motivated cosmic inflation models. Full-sky surveys for 3 years at a Lagrangian point L2 will be carried out for 15 frequency bands between 34 and 448 GHz with two telescopes to achieve the total sensitivity of 2.5
μ
K arcmin with a typical angular resolution of 0.5
∘
at 150 GHz. Each telescope is equipped with a half-wave plate system for polarization signal modulation and a focal plane filled with polarization-sensitive TES bolometers. A cryogenic system provides a 100 mK base temperature for the focal planes and 2 K and 5 K stages for optical components.
Journal Article
Improving topological cluster reconstruction using calorimeter cell timing in ATLAS
by
Di Ciaccio, Lucia
,
Garg, Diksha
,
Tate, Aric
in
[PHYS.HEXP] Physics [physics]/High Energy Physics - Experiment [hep-ex]
,
[PHYS.PHYS.PHYS-INS-DET] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]
,
Astrophysics
2024
Journal Article
Double Chooz θ13 measurement via total neutron capture detection
by
Ishitsuka, M
,
Bezerra, T J
,
Kuze, M
in
639/766/419/1131
,
Atomic
,
Classical and Continuum Physics
2020
Neutrinos were assumed to be massless particles until the discovery of the neutrino oscillation process. This phenomenon indicates that the neutrinos have non-zero masses and the mass eigenstates (
ν
1
,
ν
2
,
ν
3
) are mixtures of their flavour eigenstates (
ν
e
,
ν
μ
,
ν
τ
). The oscillations between different flavour eigenstates are described by three mixing angles (
θ
12
,
θ
23
,
θ
13
), two differences of the squared neutrino masses of the
ν
2
/
ν
1
and
ν
3
/
ν
1
pairs and a charge conjugation parity symmetry violating phase
δ
CP
. The Double Chooz experiment, located near the Chooz Electricité de France reactors, measures the oscillation parameter
θ
13
using reactor neutrinos. Here, the Double Chooz collaboration reports the measurement of the mixing angle
θ
13
with the new total neutron capture detection technique from the full data set, yielding sin
2
(2
θ
13
) = 0.105 ± 0.014. This measurement exploits the multidetector configuration, the isoflux baseline and data recorded when the reactors were switched off. In addition to the neutrino mixing angle measurement, Double Chooz provides a precise measurement of the reactor neutrino flux, given by the mean cross-section per fission 〈
σ
f
〉 = (5.71 ± 0.06) × 10
−43
cm
2
per fission, and reports an empirical model of the distortion in the reactor neutrino spectrum.
The Double Chooz collaboration reports the neutrino oscillation parameter
θ
13
from a measurement of the disappearance of reactor anti-electron neutrinos with the total neutron capture technique.
Journal Article
SNEWPY: A Data Pipeline from Supernova Simulations to Neutrino Signals
by
Lincetto, Massimiliano
,
Hill, Remington
,
Horiuchi, Shunsaku
in
Detectors
,
Explosions
,
Fluence
2022
Current neutrino detectors will observe hundreds to thousands of neutrinos from Galactic supernovae, and future detectors will increase this yield by an order of magnitude or more. With such a data set comes the potential for a huge increase in our understanding of the explosions of massive stars, nuclear physics under extreme conditions, and the properties of the neutrino. However, there is currently a large gap between supernova simulations and the corresponding signals in neutrino detectors, which will make any comparison between theory and observation very difficult. SNEWPY is an open-source software package that bridges this gap. The SNEWPY code can interface with supernova simulation data to generate from the model either a time series of neutrino spectral fluences at Earth, or the total time-integrated spectral fluence. Data from several hundred simulations of core-collapse, thermonuclear, and pair-instability supernovae is included in the package. This output may then be used by an event generator such as sntools or an event rate calculator such as the SuperNova Observatories with General Long Baseline Experiment Simulator (SNOwGLoBES). Additional routines in the SNEWPY package automate the processing of the generated data through the SNOwGLoBES software and collate its output into the observable channels of each detector. In this paper we describe the contents of the package, the physics behind SNEWPY, the organization of the code, and provide examples of how to make use of its capabilities.
Journal Article
Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD
by
Gjerlw, E.
,
Prouv, T.
,
Doumayrou, E.
in
Bolometer
,
Bolometers
,
Characterization and Evaluation of Materials
2022
Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. We discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64
-
0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN
x
/Nb microstrip at 100 mK and over the frequency range 200–350 GHz, which is comparable to values previously reported in the literature.
Journal Article
Fluorescence to measure light intensity
by
Coghill, Ian
,
Nedbal, Ladislav
,
Jeanneret, Raphaël
in
631/1647/245/2225
,
631/92/96
,
Actinometry
2023
Despite the need for quantitative measurements of light intensity across many scientific disciplines, existing technologies for measuring light dose at the sample of a fluorescence microscope cannot simultaneously retrieve light intensity along with spatial distribution over a wide range of wavelengths and intensities. To address this limitation, we developed two rapid and straightforward protocols that use organic dyes and fluorescent proteins as actinometers. The first protocol relies on molecular systems whose fluorescence intensity decays and/or rises in a monoexponential fashion when constant light is applied. The second protocol relies on a broad-absorbing photochemically inert fluorophore to back-calculate the light intensity from one wavelength to another. As a demonstration of their use, the protocols are applied to quantitatively characterize the spatial distribution of light of various fluorescence imaging systems, and to calibrate illumination of commercially available instruments and light sources.
Two methods for fluorescence-based actinometry using organic dyes and photoconvertible fluorescent proteins enable rapid and precise measurement of light intensity at the sample in fluorescence microscopes.
Journal Article
Double diffraction imaging of x-ray induced structural dynamics in single free nanoparticles
2024
Because of their high photon flux, x-ray free-electron lasers (FEL) allow to resolve the structure of individual nanoparticles via coherent diffractive imaging (CDI) within a single x-ray pulse. Since the inevitable rapid destruction of the sample limits the achievable resolution, a thorough understanding of the spatiotemporal evolution of matter on the nanoscale following the irradiation is crucial. We present a technique to track x-ray induced structural changes in time and space by recording two consecutive diffraction patterns of the same single, free-flying nanoparticle, acquired separately on two large-area detectors opposite to each other, thus examining both the initial and evolved particle structure. We demonstrate the method at the extreme ultraviolet (XUV) and soft x-ray Free-electron LASer in Hamburg (FLASH), investigating xenon clusters as model systems. By splitting a single XUV pulse, two diffraction patterns from the same particle can be obtained. For focus intensities of about 2 × 10 12 W cm −2 we observe still largely intact clusters even at the longest delays of up to 650 picoseconds of the second pulse, indicating that in the highly absorbing systems the damage remains confined to one side of the cluster. Instead, in case of five times higher flux, the diffraction patterns show clear signatures of disintegration, namely increased diameters and density fluctuations in the fragmenting clusters. Future improvements to the accessible range of dynamics and time resolution of the approach are discussed.
Journal Article
Origins space telescope: from first light to life
2021
The Origins Space Telescope (Origins) is one of four science and technology definition studies selected by the National Aeronautics and Space Administration (NASA) in preparation of the 2020 Astronomy and Astrophysics Decadal survey in the US. Origins will trace the history of our origins from the time dust and heavy elements permanently altered the cosmic landscape to present-day life. It is designed to answer three major science questions: How do galaxies form stars, make metals, and grow their central supermassive black holes from reionization? How do the conditions for habitability develop during the process of planet formation? Do planets orbiting M-dwarf stars support life? Origins operates at mid- to far-infrared wavelengths from ~ 2.8 μm to 588 μm, and is more than 1000 times more sensitive than prior far-IR missions due to its cold (~ 4.5 K) aperture and state-of-the-art instruments.
Journal Article
Concept Study of Optical Configurations for High-Frequency Telescope for LiteBIRD
by
Otani, C.
,
Matsuura, S.
,
Jeong, O.
in
Aperture
,
Characterization and Evaluation of Materials
,
Condensed Matter Physics
2018
The high-frequency telescope for LiteBIRD is designed with refractive and reflective optics. In order to improve sensitivity, this paper suggests the new optical configurations of the HFT which have approximately 7 times larger focal planes than that of the original design. The sensitivities of both the designs are compared, and the requirement of anti-reflection (AR) coating on the lens for the refractive option is derived. We also present the simulation result of a sub-wavelength AR structure on both surfaces of silicon, which shows a band-averaged reflection of 1.1–3.2% at 101–448 GHz.
Journal Article