Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
10 result(s) for "piezo-surgery"
Sort by:
A Modified Ridge Splitting Technique Using Autogenous Bone Blocks—A Case Series
Background: Alveolar atrophy following tooth loss is a common limitation of rehabilitation with dental implant born prostheses. Ridge splitting is a well-documented surgical method to restore the width of the alveolar ridge prior to implant placement. The aim of this case series is to present a novel approach to ridge expansion using only autogenous bone blocks. Methods: Patients with Kennedy Class I. and II. mandibles with insufficient bone width were included in this study. Ridge splitting was carried out with the use of a piezoelectric surgery device by preparing osteotomies and after mobilization of the buccal cortical by placing an autologous bone block harvested from the retromolar region as a spacer between the buccal and lingual cortical plates. Block-grafts were stabilized by osteosynthesis screws. Implant placement was carried out after a 3-month healing period. A total of 13 implants were placed in seven augmented sites of six patients. Results: Upon re-entry, all sites healed uneventfully. Mean ridge width gain was 2.86 mm, range: 2.0–5.0 mm. Conclusions: Clinical results of our study show that the modified ridge splitting technique is a safe and predictable method to restore width of the alveolar ridge prior to implant placement.
Complementarity of Photo-Biomodulation, Surgical Treatment, and Antibiotherapy for Medication-Related Osteonecrosis of the Jaws (MRONJ)
Background and Objectives: Antiresorptive or anti-angiogenic agents may induce medication-related osteonecrosis of the jaws (MRONJ), which represents a challenge for clinicians. The aim of this study is to design and apply a composed and stage-approach therapy combining antibiotherapy, surgical treatment, and photo-biomodulation (PBM) for the prevention or treatment of MRONJ lesions. Materials and Methods: The proposed treatment protocol was carried out in the Department of Oral & Maxillofacial Surgery of the “Victor Babes” University of Medicine and Farmacy of Timisoara, in 2018–2020. A total of 241 patients who were previously exposed to antiresorptive or anti-angiogenic therapy, as well as patients already diagnosed with MRONJ at different stages of the disease were treated. A preventive protocol was applied for patients in an “at risk” stage. Patients in more advanced stages received a complex treatment. Results: The healing proved to be complete, with spontaneous bone coverage in all the n = 84 cases placed in an “at risk” stage. For the n = 49 patients belonging to stage 0, pain reductions and decreases of mucosal inflammations were also obtained in all cases. For the n = 108 patients proposed for surgery (i.e., in stages 1, 2, or 3 of MRONJ), a total healing rate of 91.66% was obtained after the first surgery, while considering the downscaling to stage 1 as a treatment “success”, only one “failure” was reported. This brings the overall “success” rate to 96.68% for a complete healing, and to 99.59% when downscaling to stage 1 is included in the healing rate. Conclusions: Therefore, the clinical outcome of the present study indicates that patients with MRONJ in almost all stages of the disease can benefit from such a proposed association of methods, with superior clinical results compared to classical therapies.
Bone Micromorphology and Material Attrition After Sonic, Ultrasonic and Conventional Osteotomies
Osteotomy as the first step in surgery, provides access to the field and its application could influence the outcome. Nowadays, the conventional burr reduction is being challenged by newer sonic and ultrasonic methods. We investigated the bone structural integrity and metal attrition residues both in bone and the irrigation fluid. Bovine ribs were cut using three methods. Bone cuts were studied using Environmental Scanning Electron Microscopy (ESEM) for tissue discrepancies and Scanning Electron Microscopy/Energy Dispersion X-Ray Microanalysis (SEM/EDX) for organic and inorganic debris. Better preservation of bone architecture was seen in piezo and sono surgery while metal attrition was not conclusive (p>0.05). Unlike in bone analyses, both bur and ultrasonic osteotomies showed statistically significant higher median inorganic detection per analysis (p=0.021 and p=0.037, respectively). Sono and piezo surgery proved to be less invasive while attrition properties were the same.
Factors Influencing Outcome After Frontal Beak Reduction—Does the Surgical Tool Matter?
Introduction: Chronic rhinosinusitis (CRS) with frontal sinus outflow tract (FSOT) obstruction frequently requires frontal beak reduction during endoscopic sinus surgery (ESS). While technical approaches such as rotary drilling or piezoelectric osteotomy may differ in precision and tissue preservation, it is unclear whether surgical instrument choice or patient-specific clinical characteristics influence postoperative quality of life (QoL). Methods: In this prospective cohort study, 49 adult CRS patients undergoing ESS with frontal beak reduction were enrolled (28 males, mean age 50 ± 15 years). Osteotomy was performed using either a conventional drill (n = 25) or piezoelectric knife (n = 24). Baseline clinical data included presence of nasal polyps, asthma, and radiologic severity (Lund–Mackay and Zinreich CT scores). Outcomes included patient-reported symptoms with the 22-item Sino-Nasal Outcome Test (SNOT-22) and visual analogue scale (VAS), and endoscopic Lund–Kennedy scores, recorded preoperatively and at 1, 4, and 24 weeks postoperatively. Results: Both groups demonstrated significant postoperative improvement in SNOT-22 and VAS scores. No significant correlation was observed between SNOT-22 changes and Lund–Kennedy scores in either tool group. Presence of nasal polyps was associated with higher pre- and postoperative Zinreich and Lund–Mackay scores (p < 0.05). Asthma was linked to higher early postoperative symptom burden (nasal blockage, clear discharge; p < 0.05). Tool choice did not significantly influence QoL recovery or modify the effect of clinical characteristics on outcomes. Conclusions: Postoperative QoL improvement was driven primarily by baseline disease phenotype—particularly nasal polyposis and asthma—while the choice of osteotomy instrument did not significantly influence recovery trajectories. The Zinreich score provided additional phenotypic stratification in CRS with FSOT obstruction.
Postoperative Periorbital Edema and Ecchymosis After External Lateral Osteotomy “Comparing Conventional Osteotome and Piezo Scalpel in Rhinoplasty”
The piezo surgery was reported to cause minimal trauma to the soft tissue. The aim of this study was to compare the periorbital edema and ecchymosis after transcutaneous lateral osteotomy in rhinoplasty using 2-mm osteotome versus Piezo scalpel respectively. In a randomized clinical trial and split-mouth-design, we performed primary rhinoplasty in 15 patients (7 men, 8 women; age 18–35 years, mean age 26.6 ± 5.7 years). Transcutaneous lateral osteotomy was performed using a 2-mm osteotome on the one side and a piezo scalpel on the opposite side. We took digital photographs of the face on 1, 3, 7 and 14 postoperative days. Three examiners used a standard 5-point Kara-Gokalan scale to assess the early postoperative periorbital edema and ecchymosis on each side. We found more difficult to use the piezo scalpel via only one incision and found easier to use two stab incisions for inserting the piezo scalpel. The time spend for each osteotomy was similar ( P  > 0.05). The inter-observer agreement was high (> 0.676). The postoperative edema showed to be significantly different on day 1, 3 and 7 ( P -value < 0.05), ecchymosis was much less on piezo side but not significantly. It was more difficult to use piezo scalpel via only one incision. The piezo scalpel showed to reduce the postoperative edema significantly and improved the ecchymosis. Swelling and bleeding could have crossed the midline and blurred the comparison of two sides. However, this is the best design to achieve the highest similarity in study condition. Level of Evidence Level I, therapeutic study.
A comparison of piezo surgery osteotomies with conventional internal osteotomies as performed by trainee surgeons: a cadaveric study
Aesthetic rhinoplasty remains a challenging procedure with high expectations and narrow tolerance for errors. Considerable training is required to achieve controlled and reliable results. Use of the Piezotome is gaining popularity for performing the nasal osteotomies, a key step in rhinoplasty, where it is reported to improve precision and predictability and to keep tissue damage to a minimum. We compare the outcomes of conventional osteotomy techniques to piezosurgery in human cadavers as undertaken by surgical trainees. Seven human cadavers were used and a total of 14 osteotomies were performed. Conventional osteotomies and piezosurgery were carried out each on one side of the cadaver. A number of fragments and a blinded assessment of the accuracy of the osteotomy compared with the preprocedure skin markings were carried out by two experienced rhinoplasty surgeons. The Mann-Whitney test for statistical analysis was used. The mean number of fragments was 1.57 in the piezosurgery osteotomy and 2.14 using conventional osteotomies. Four of seven piezosurgery osteotomies achieved an accuracy within 1mm. The conventional osteotomies as performed by the trainees showed a significant mismatch of more than 3mm in three of seven of cases. Accuracy within 1mm was achieved in one of seven cases. Piezosurgery offers a safe, reliable and precise method of performing lateral nasal osteotomies. This human cadaver study shows a high accuracy of osteotomy and fewer comminuted fractures using this technique compared with conventional osteotomy techniques.
Primary Stability of Implants Inserted into Polyurethane Blocks: Micro-CT and Analysis In Vitro
The approach employed for the site preparation of the dental implant is a variable factor that affects the implant’s primary stability and its ability to integrate with the surrounding bone. The main objective of this in vitro study is to evaluate the influence of different techniques used to prepare the implant site on the primary stability of the implant in two different densities of artificial bone. Materials and Methods: A total of 150 implant sites were prepared in rigid polyurethane blocks to simulate two distinct bone densities of 15 pounds per cubic foot (PCF) and 30 PCF, with a 1-mm-thick simulated cortex. The implant sites were equally distributed among piezoelectric surgery (PES), traditional drills (TD), and black ruby magnetic mallet inserts (MM). Two methods have been employed to evaluate the implant’s primary stability, Osstell and micro-tomography. Results: In the present study, we observed significant variations in the implant stability quotient (ISQ) values. More precisely, our findings indicate that the ISQ values were generally higher for 30 PCF compared to 15 PCF. In terms of the preparation technique, PES exhibited the greatest ISQ values, followed by MM, and finally TD. These findings corresponded for both bone densities of 30 PCF (PES 75.6 ± 1.73, MM 69.8 ± 1.91, and TD 65.8 ± 1.91) and 15 PCF (PES 72.3 ± 1.63, MM 62.4 ± 1.77, and TD 60.6 ± 1.81). By utilizing Micro-CT scans, we were able to determine the ratio of the implant occupation to the preparation site. Furthermore, we could calculate the maximum distance between the implant and the wall of the preparation site. The findings demonstrated that PES had a higher ratio of implant to preparation site occupation, followed by TD, and then the MM, at a bone density of 30 PCF (PES 96 ± 1.95, TD 94 ± 1.88, and MM 90.3 ± 2.11). Nevertheless, there were no statistically significant differences in the occupation ratio among these three approaches in the bone density of 15 PCF (PES 89.6 ± 1.22, TD 90 ± 1.31, and MM 88.4 ± 1.17). Regarding the maximum gap between the implant and the site preparation, the smallest gaps were seen when TD were used, followed by MM, and finally by PES, either in a bone density 15 PCF (PES 318 ± 21, TD 238 ± 17, and MM 301 ± 20 μm) or in a bone density 30 PCF (PES 299 ± 20, TD 221 ± 16, and MM 281 ± 19 μm). A statistical analysis using ANOVA revealed these differences to be significant, with p-values of < 0.05. Conclusion: The outcomes of this study indicate that employing the PES technique and osteo-densification with MM during implant insertion may enhance the primary stability and increase the possibility of early implant loading.
Full-Mouth Rehabilitation of a Patient with Gummy Smile—Multidisciplinary Approach: Case Report
The impairment of aesthetic function leads to a decreased quality of life. An unaesthetic smile due to excessive gingival exposure demands, most of the time, a complex treatment in which the objective is the vertical reduction of the amount of exposed fixed gingiva by obtaining a complete exposure of the anatomical crown of the teeth and restoring the ideal dimensions of the biological width. This paper presents a case of a 48-year-old female patient who was unsatisfied with her aesthetics and had disturbed masticatory function due to the absence of some posterior teeth. The cone beam computed tomography was performed to evaluate the facial and dental morphology. The treatment plan included diode laser and piezo-surgery utilization for the frontal area of the upper arch and implants to restore the distal area of the lower and upper arch. Zirconia ceramic was used for the final restorations. This complex and multidisciplinary full-mouth rehabilitation lasted for two years, and the patient was pleased with the result. This case showed that a well-established treatment plan is necessary to obtain long-lasting results. The use of adequate procedures and equipment ensures a predictable result.
Role of plasma-rich fibrin in oral surgery
Platelet-rich fibrin (PRF) is a fibrin meshwork, in which platelet cytokines, growth factors, and cells are entrapped and discharged after a period and can serve as a resorbable film. PRF is the next generation of platelet concentrates equipped to improve arrangement without biochemical blood handling; PRF is an evolution of the fibrin adhesive, which is widely used in the oral surgery. The guidelines of this innovation depend on concentrating platelets and growth factors in a plasma medium, and initiating them in a fibrin gel, keeping in mind the end goal to enhance the healing of wounds. Maxillary bone loss requires numerous regenerative techniques: as a supplement to the procedures of tissue regeneration, a platelet concentrate called PRF was tested for the 1st time in France by Dr. Choukroun. This article enriches the benefits and role of plasma-rich fibrin in oral surgery. Platelet-concentrate fibrin is an evolution of the fibrin glue, which is widely used in the oral surgery.
Intraoral osteotomies using piezosurgery for distraction in an infant with Pierre–Robin sequence
Airway management in infants with Pierre Robin sequence (PRS) is often challenging. Advancement of the tongue base using mandibular distraction in neonates can avoid tracheotomy and is increasingly propagated. The osteotomies can be performed via intra- and extraoral approaches. Nowadays, for precise bone cutting, piezosurgical devices have been introduced in maxillofacial surgery, which we used for osteotomies via the intraoral approach in the 7-week-old patient presented in this study. Instead of a preoperative CT scan, a 3D data set was generated preoperatively in the operating theatre using a 3D C-arm system. After bilateral transcutaneous pin placement and osteotomies, a second 3D data set was acquired. Primary and secondary reconstructions clearly visualized the patient's bone despite the low level of ossification in newborns and the presence of a large amount of metal implants. In view of the low level of radiation exposure going along with the 3D C-arm imaging, a follow-up examination after removal of the distractors was performed. With this report of a 7-week-old female infant with the diagnosis of PRS, we want to extend the surgical and diagnostic armamentarium for the treatment of infants with PRS.