Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
3
result(s) for
"second generation glucose biosensor"
Sort by:
A Mediated Enzymatic Electrochemical Sensor Using Paper-Based Laser-Induced Graphene
2022
Laser-induced graphene (LIG) has been applied in many different sensing devices, from mechanical sensors to biochemical sensors. In particular, LIG fabricated on paper (PaperLIG) shows great promise for preparing cheap, flexible, and disposable biosensors. Distinct from the fabrication of LIG on polyimide, a two-step process is used for the fabrication of PaperLIG. In this study, firstly, a highly conductive PaperLIG is fabricated. Further characterization of PaperLIG confirmed that it was suitable for developing biosensors. Subsequently, the PaperLIG was used to construct a biosensor by immobilizing glucose oxidase, aminoferrocene, and Nafion on the surface. The developed glucose biosensor could be operated at a low applied potential (−90 mV) for amperometric measurements. The as-prepared biosensor demonstrated a limit of detection of (50–75 µM) and a linear range from 100 µM to 3 mM. The influence of the concentration of the Nafion casting solution on the performance of the developed biosensor was also investigated. Potential interfering species in saliva did not have a noticeable effect on the detection of glucose. Based on the experimental results, the simple-to-prepare PaperLIG-based saliva glucose biosensor shows great promise for application in future diabetes management.
Journal Article
Charge mediation by ruthenium poly(pyridine) complexes in 'second-generation' glucose biosensors based on carboxymethylated β-cyclodextrin polymer membranes
by
Kutner, Wlodzimierz
,
Kosela, Edyta
,
Elzanowska, Hanna
in
acetaminophen
,
beta-cyclodextrin
,
beta-Cyclodextrins
2002
Four different poly(pyridine) complexes of ruthenium, viz. Ru(II)(trpy)(phen)(OH(2))](2+) (1), trans-[Ru(III)(2,2'bpy)(2)(OH(2))(OH)](2+) (2), [(2,2'bpy)(2)(OH)Ru(III)ORu(III)(OH)(2,2'bpy)(2)](4+) (3), and [Ru(II)(4,4'bpy)(NH(3))(5)](2+) (4) (2,2'bpy=2,2'-bipyridine, 4,4'bpy=4,4'-bipyridine, trpy=2,2',2\"-terpyridine, phen=1,10-phenanthroline), were tested as non-physiological charge mediators of 'second-generation' glucose biosensors. The membranes for these biosensors were prepared by casting anionic carboxymethylated beta-cyclodextrin polymer films (beta-CDPA) directly onto the Pt or glassy carbon (GC) disk electrodes. Simultaneously, glucose oxidase (GOD) was immobilized in the films by covalent bonding and the Ru complexes were incorporated both by inclusion in the beta-CD molecular cavities and by ion exchange at the fixed carboxymethyl cation-exchange sites. The leakage of the mediator from the polymer has been minimized by adopting a suitable pre-treatment procedure. The biosensors catalytic activities increased in the order 1<2<3<4, as established by linear sweep voltammetry. In case of complexes 2-4, the enzymatic glucose oxidation was mediated by the Ru complexes at their redox potentials. However, this oxidation was mediated by oxygen in case of complex 1 where H(2)O(2) was detected as the reaction product. The effectiveness of the mediators used in the presence of oxygen has been estimated using Pt and GC supports. The redox potential of the mediator does not depend on the support used, while the oxidation of H(2)O(2) proceeds on GC at much higher positive potentials than on Pt. The sensitivity and the linear concentration range of the biosensor studied varied significantly. For complex 4, which forms stable inclusion complex with beta-CD, the biosensor sensitivity was the highest and equal to 7.2 micro A mM(-1) cm(-2), detectability was as low as 1 mM, but the linear concentration range was limited only to 4 mM. In contrast, for complexes 2 and 3 the sensitivity was 0.4 and 3.2 micro A mM(-1) cm(-2), while the linear concentration range extended up to at least 24 and 14 mM glucose, respectively. Even though some common interfering substances, such as ascorbate, paracetamol or urea, are oxidized at potentials close to those of the Ru complex redox couples, their electro-oxidation currents at physiological concentrations are insignificant compared to those due to the biocatalytic oxidation of glucose. The biosensor response to glucose is reversible as demonstrated by the inhibition of GOD activity by Cu(II). That is, the Cu(II) concentration required to inhibit by half the response to glucose of the biosensor containing complex 2 was 1.0 mM. This inhibitory effect was fully reversed by addition of citrate, a ligand forming sufficiently stable complex with Cu(II).
Journal Article
Effect of Poly-l-Lysine Polycation on the Glucose Oxidase/Ferricyanide Composite-Based Second-Generation Blood Glucose Sensors
by
Lin, Ming-Jie
,
Wu, Ching-Chou
,
Chang, Ko-Shing
in
Blood Glucose - analysis
,
Electrochemical Techniques - methods
,
Electrodes
2019
Second-generation glucose biosensors are presently the mainstream commercial solution for blood glucose measurement of diabetic patients. Screen-printed carbon electrodes (SPCEs) are the most-used substrate for glucose testing strips. This study adopted hydrophilic and positively charged α-poly-l-lysine (αPLL) as the entrapment matrix for the immobilization of negatively charged glucose oxidase (GOx) and ferricyanide (FIC) on SPCEs to construct a disposable second-generation glucose biosensor. The αPLL modification is shown to facilitate the redox kinetics of FIC and ferrocyanide on the SPCEs. The SPCEs coated with 0.5 mM GOx, 99.5 mM FIC, and 5 mM αPLL had better sensitivity for glucose detection due to the appreciable effect of protonated αPLL on the promotion of electron transfer between GOx and FIC. Moreover, the SPCEs coated with 0.5 mM GOx, 99.5 mM FIC, and 5 mM αPLL were packaged as blood glucose testing strips for the measurement of glucose-containing human serum samples. The glucose testing strips had good linearity from 2.8 mM to 27.5 mM and a detection limit of 2.3 mM. Moreover, the 5 mM αPLL-based glucose testing strips had good long-term stability to maintain GOx activity in aging tests at 50 °C.
Journal Article