Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
2
result(s) for
"temperature-based validation method"
Sort by:
Analysis of Land Surface Performance Differences and Uncertainty in Multiple Versions of MODIS LST Products
2024
Moderate Resolution Imaging Spectroradiometer (MODIS) Land Surface Temperature (LST) products are essential data sources for global and regional climate change research. Currently, several versions of the MODIS LST product have been released, yet the performance differences and uncertainties they introduce in land surface studies remain insufficiently addressed. To bridge this gap, this study focuses on four distinct versions of the LST product: MxD11A1 Collection 5 (C5), Collection 6 (C6), Collection 6.1 (C6.1), and MxD21A1 Collection 6.1 (MxD21). The spatial resolution of all product generations is 1 km, and the temporal resolution is 0.5 days. This study provides a comprehensive analysis of the errors arising from different generations of these products in various land surface process studies. The error assessment includes cross-comparisons between product versions and evaluations of the absolute errors generated. Absolute errors in evaluation data were collected from 13 surface sites within the Heihe Watershed Allied Telemetry Experimental Research (HiWATER) project during the period 2013–2018. Cross-validation results show that the largest difference between C5 and C6.1 occurs over bare land, with an RMSE of approximately 1.45 K, while there is no significant change between C6 and C6.1. MOD21 shows considerable variation compared to C6.1 at night across different land cover types, with RMSE over cropland exceeding 2 K. The temperature difference between MOD21 and C6.1 is more pronounced at night (2.01 K) than during the day (0.30 K). Validation results based on temperature indicate that C5 has greater uncertainty compared to C6, especially over bare land, where errors are 2.06 K and 1.06 K, respectively. Furthermore, MxD21 demonstrates significant day–night performance discrepancies, with an average bias of 0.10 K at night, while daytime errors over bare land can reach 2 K, potentially influenced by atmospheric conditions. Based on the research in this paper, it is possible to clarify the performance of different versions of MODIS products, reflecting the appropriateness of their past applications; on the other hand, it is recommended to prioritize the use of the MxD11A1 C6 and C6.1 products for monitoring and applications in bare soil areas to ensure higher accuracy. Furthermore, for day and night monitoring, it may be beneficial to alternate between the MxD11A1 and MxD21A1 products to fully leverage their respective advantages and enhance overall monitoring effectiveness.
Journal Article
Automatic CT-based finite element model generation for temperature-based death time estimation: feasibility study and sensitivity analysis
by
Zachow, Stefan
,
Schenkl, Sebastian
,
Hubig, Michael
in
Computation
,
Computer aided design
,
Computer Simulation
2017
Temperature-based death time estimation is based either on simple phenomenological models of corpse cooling or on detailed physical heat transfer models. The latter are much more complex but allow a higher accuracy of death time estimation, as in principle, all relevant cooling mechanisms can be taken into account.
Here, a complete workflow for finite element-based cooling simulation is presented. The following steps are demonstrated on a CT phantom:
Computer tomography (CT) scan
Segmentation of the CT images for thermodynamically relevant features of individual geometries and compilation in a geometric computer-aided design (CAD) model
Conversion of the segmentation result into a finite element (FE) simulation model
Computation of the model cooling curve (MOD)
Calculation of the cooling time (CTE)
For the first time in FE-based cooling time estimation, the steps from the CT image over segmentation to FE model generation are performed semi-automatically. The cooling time calculation results are compared to cooling measurements performed on the phantoms under controlled conditions. In this context, the method is validated using a CT phantom. Some of the phantoms’ thermodynamic material parameters had to be determined via independent experiments.
Moreover, the impact of geometry and material parameter uncertainties on the estimated cooling time is investigated by a sensitivity analysis.
Journal Article