Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
51 Impact of the Introduction of a Standardised ICD Programming Protocol: Real-world Data from a Single Centre
by
Li, Anthony
, Petzer, Ed
, Murgatroyd, Francis
, Dhillon, Para
, Scott, Paul
, Sunderland, Nicholas
, Kaura, Amit
, Kamdar, Ravi
2016
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
51 Impact of the Introduction of a Standardised ICD Programming Protocol: Real-world Data from a Single Centre
by
Li, Anthony
, Petzer, Ed
, Murgatroyd, Francis
, Dhillon, Para
, Scott, Paul
, Sunderland, Nicholas
, Kaura, Amit
, Kamdar, Ravi
2016
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
51 Impact of the Introduction of a Standardised ICD Programming Protocol: Real-world Data from a Single Centre
Journal Article
51 Impact of the Introduction of a Standardised ICD Programming Protocol: Real-world Data from a Single Centre
2016
Request Book From Autostore
and Choose the Collection Method
Overview
AimsRandomised trials have shown that empiric ICD programming, using long detection times and high detection zones, reduces device therapy in ICD recipients. However, there is less data on its effectiveness in a “real-world” setting, especially secondary prevention patients. Our aim was to evaluate the introduction of a standardised programming protocol in a “real-world” setting of unselected ICD recipients.MethodsWe analysed 270 consecutive ICD recipients implanted in a single centre – 135 implanted prior to protocol implementation (Physician-Led group) and 135 after (Standardised group). The protocol included long arrhythmia detection times (30/40 or equivalent) and high rate detection zones (primary prevention lower treatment zone 200 bpm). Programming in the Physician-Led group was at the discretion of the implanter. The primary endpoint was time-to-any therapy (ATP or shocks). Secondary endpoints were time-to-inappropriate therapy and time-to-appropriate therapy. The safety endpoints were syncopal episodes, hospital admissions, and death.ResultsAt 12 months follow-up, 47 patients had received any ICD therapy (Physician-Led group, n = 31 vs. Standardised group, n = 16). There was a 47% risk reduction in any device therapy (p = 0.04) and an 86% risk reduction in inappropriate therapy (p = 0.009) in the Standardised compared to the Physician-led group. Results were consistent across primary and secondary prevention patients. There were no significant differences in the rates of syncope, hospitalization and death.ConclusionsIn unselected patients in a “real-world” setting introduction of a standardised programming protocol, using long detection times and high detection zones, significantly reduces the burden of ICD therapy without an increase in adverse outcomes.Abstract 51 Figure 1Kaplan-Meier curves for survival from any-therapy. Physician-Led (dotted) vs. Standardised (black)Abstract 51 Figure 2Kaplan-Meier curves for survival from inappropriate therapy. Physician-led (dotted) vs. Standardised (black)
Publisher
BMJ Publishing Group LTD
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.