Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
3PC-030 Analytical method validation to carry out physicochemical stability studies of methadone oral solutions
by
Esteban Casado, S
, Lorenzo García, MP
, Tejedor Prado, P
, Rupérez Pascualena, FJ
, Lázaro Cebas, A
, Such Díaz, A
, Álvaro Alonso, EA
, Escobar Rodríguez, I
, Aguilar Ros, A
, Cañamares Orbis, I
in
Methadone
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
3PC-030 Analytical method validation to carry out physicochemical stability studies of methadone oral solutions
by
Esteban Casado, S
, Lorenzo García, MP
, Tejedor Prado, P
, Rupérez Pascualena, FJ
, Lázaro Cebas, A
, Such Díaz, A
, Álvaro Alonso, EA
, Escobar Rodríguez, I
, Aguilar Ros, A
, Cañamares Orbis, I
in
Methadone
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
3PC-030 Analytical method validation to carry out physicochemical stability studies of methadone oral solutions
by
Esteban Casado, S
, Lorenzo García, MP
, Tejedor Prado, P
, Rupérez Pascualena, FJ
, Lázaro Cebas, A
, Such Díaz, A
, Álvaro Alonso, EA
, Escobar Rodríguez, I
, Aguilar Ros, A
, Cañamares Orbis, I
in
Methadone
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
3PC-030 Analytical method validation to carry out physicochemical stability studies of methadone oral solutions
Journal Article
3PC-030 Analytical method validation to carry out physicochemical stability studies of methadone oral solutions
2020
Request Book From Autostore
and Choose the Collection Method
Overview
Background and importanceOn the basis of resolution 189/2018 published by our city health council, the hospital pharmacy service was entrusted with the centralisation of the procedure for the acquisition, compounding, distribution and dispensing of methadone to drug addicts in integral attention centres. In order to improve and increase the beyond use date (BUD) of methadone oral solutions, we carried out a physicochemical stability study.Aim and objectivesTo develop an analytical method and validation to carry out a physicochemical stability study of two oral solutions of methadone to increase their BUD. Method development should be made in an effective and reproducible manner.Material and methodsThe study was carried out on two formulations of methadone 10 mg/mL, which were prepared with and without parabens as preservatives. A high performance liquid chromatography (HPLC) Agilent 1100 was used, provided with a quaternary pump and an ultraviolet diode array detector to determine methadone. First we carried out the analytical method development to achieve the analytical performance characteristics. Then we performed validation of the analytical method obtaining linearity, instrumental intra-assay and inter-assay precision, and accuracy and recovery percentage.ResultsChromatographic conditions were: flow rate 1.6 mL/min, 55% acetonitrile and 45% phosphate buffer (adjusted to pH=10) as the mobile phase. Injection volume was 50 µL, the temperature in the column compartment was 40°C. The column used was the Xterra C18 because methadone pKa is 8.3. Retention time for methadone was 4.5 min and for parabens 1.5 min.The final methadone determination method was validated for a standard of 10 mg/mL and applied for the determination of methadone with two parabens. The most relevant results were: correlation coefficient r=0.9957 for methadone in the range tested (7.5–12.5 mg/mL); instrumental precision 0.33% for standards (n=10); intra-assay precision 0.53% (n=6) and inter-assay precision 1.95% (n=12). The relative standard deviation percentage for accuracy was 1.28%, and the percentage recovery was 101.5 ±1.5%.Conclusion and relevanceAnalytical method development and validation procedures are vital in the discovery and development of drugs and pharmaceuticals to ensure performance of the method. The proposed HPLC conditions to determine methadone were proved to be valid and reproducible for carrying out physicochemical stability studies of different methadone oral solutions.References and/or acknowledgementsNo conflict of interest.
Publisher
BMJ Publishing Group LTD
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.